Global Nuclear Fuel RAJ-II Safety Analysis Report Amendment Pre-application Meeting February 15, 2022 GNi=

Global Nuclear Fuel

Agenda

  • Purpose - Expand Existing RAJ-II Safety Basis (public)
  • Overview of the RAJ-II Package (public)
  • Description of the requested additional payload and SAR amendment (public)
  • Overview of SAR Changes (non-public)
  • Timeline (non-public)

GNii=

Global Nuclear Fuel 2

Purpose Introduce and provide NRC with technical information regarding an amendment for Revision 11 of the Safety Analysis Report (SAR) to expand payload content parameters of the RAJ-II container, Certificate of Compliance (CoC) 9309.

GNi=

Global Nuclear Fuel 3

Overview of the RAJ-II Package

  • NRC approved for Type B fissile material package

~

  • 2 compartments in the inner container (IC), SS sheets encasing thermal insulator
  • SS outer container (OC)
  • Vibro-isolating device and shock absorbers (wood & honeycomb) between IC and OC
  • Approved for shipment for unirradiated BWR assemblies and loose rods (UC and generic BWR/PWR)

GN-r Global Nuclear Fuel

  • Packaging materials:

polyethylene, plastics

  • Can ship channeled or unchanneled for 8x8, 9x9, 1Ox10 fuel designs 4

Summary of RAJ-II SAR Amendment No package or hardware modifications.

Increase allowed Uranium-235 (U-235) enrichment up to 8 wt.% for GNF 1Ox10 fuel bundle and loose light water rod contents.

Increase Criticality Safety Index (CSI) for increased U-235 enrichment content (>5 wt.%).

New content will be introduced as an amendment to the RAJ-II SAR.

Minor administrative SAR updates will also be provided.

A proposed RAJ-I I Coe mark-up will be provided as part of the amendment submittal.

GNii=

Global Nuclear Fuel 5

6 END OF PUBLIC DISCUSSION GNi=

Global Nuclear Fuel

LEU+ Contents Low Enriched Uranium Plus (LEU+)

Increase in allowed maximum U-235 content

  • Current RAJ-II CoC 9309 Rev.12 allows:
  • 5.00 x 10-2 g/gU
  • 8.00 x 10-2 g/gU GNi=

Global Nuclear Fuel 7

Changes by Chapter Chapters 1, 2, 3, 7, 8

  • Updates to incorporate new LEU+ contents Chapter 4
  • Updated leak rate calculation and evaluation based on LEU+ contents Chapter 5
  • Updated shielding calculation and evaluation based on LEU+ contents GNii=

Global Nuclear Fuel 8

Chapter 6 General Changes

  • CSI = 1.6 for an 8x8 package array with 5 - 8 wt.%

U-235 range Fuel Assembly Loading Criteria (SAR Table 6-1)

  • Increase in minimum number of gad rods in the 5 - 8 wt.% U-235 range
  • Determination of lattice enrichment for a CSI 1.6 with no gadolinia GNii=

Global Nuclear Fuel 9

Submittal Schedule

  • GNF-A plans to submit RAJ-II SAR, Revision 11, amendment request in the 3rd quarter 2022.
  • NRC approval is requested within one year after submittal.

GNii=

Global Nuclear Fuel 10