Nuclear Power Division 5014 Sponsoring Company Project No.
Company Record Number HI-2210161 2
Revision No.
07 Feb 2022 Issue Date Record Type Report Copyright Proprietary Classification Nuclear Quality Class Record
Title:
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Prepared by:
Reviewed by:
Approved by:
Export Control Status Not applicable.
Proprietary Classification This record does not contain confidential or Proprietary Information. The Company reserves all copyrights.
Signature histories are provided here for reference only. Company electronic signature records are traceable via the provided Verification QR Code and are available for review within the secure records management system. A valid Verification QR Code and the presence of this covering page indicates this record has been approved and accepted.
S.Anton, 07 Feb 2022 V.Makodym, 07 Feb 2022 K.Manzione, 07 Feb 2022 No Export Control Applicability to Holtec Letter 5014942 1 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Holtec International Report HI-2210161 i
Project 5014 TABLE OF CONTENTS 1.0 Introduction............................................................................................................................................ 1 2.0 Overview of the Approach...................................................................................................................... 3 2.1 FSAR vs. Qualification Report........................................................................................................... 4 2.2 Information in the Dry Storage Cask System FSAR/TS.................................................................... 4 2.3 Qualification Reports.......................................................................................................................... 5 2.4 Design Basis Assemblies.................................................................................................................... 5 2.5 Loading Patterns................................................................................................................................. 6 2.6 Acceptance Criteria............................................................................................................................ 6 2.7 Other Content Restrictions................................................................................................................. 8 2.8 Area of Applicability.......................................................................................................................... 8 2.8.1 Soluble Boron (PWR)......................................................................................................... 9 2.8.2 Exposure to NFH (PWR).................................................................................................... 9 2.8.3 Exposure to Control Components (BWR)........................................................................ 10 2.8.4 Water Density PWR.......................................................................................................... 10 2.8.5 Water Density BWR......................................................................................................... 10 2.8.6 Fuel Density...................................................................................................................... 11 2.8.7 Specific Power.................................................................................................................. 11 2.8.8 Fuel (Uranium) Mass........................................................................................................ 11 2.8.9 Fuel Condition.................................................................................................................. 11 3.0 Source Term Evaluations for Qualification of Fuel.............................................................................. 16 3.1 General............................................................................................................................................. 16 3.2 Gamma Source................................................................................................................................. 16 3.2.1 Gamma Source from Fuel................................................................................................. 17 3.2.2 Gamma Source from Activation of Non-Fuel Materials.................................................. 17 to Holtec Letter 5014942 2 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Holtec International Report HI-2210161 ii Project 5014 3.3 Fuel Neutron Source......................................................................................................................... 19 3.4 Non-Fuel Hardware........................................................................................................................ 19 3.4.1 BPRAs and TPDs.............................................................................................................. 19 3.4.2 CRAs and APSRs............................................................................................................. 20 3.4.3 Discrete Neutron Source................................................................................................... 21 3.5 ORIGAMI Calculations................................................................................................................. 22 3.6 Fuel Assemblies with Axial Blankets............................................................................................ 23 4.0 Analysis Process................................................................................................................................... 30 5.0 Conclusion.......................................................................................................................................... 32 6.0 References.......................................................................................................................................... 33 Appendix A Examples for Fuel Qualifications....................................................................................... 1 A.1 Overview.......................................................................................................................................... 1 A.2 Example 1, Generic Fuel Qualification............................................................................................ 1 A.3 Example 2, Site-Specific Fuel Qualification, Typical Plant Operation........................................... 2 A.4 Example 3, Site-Specific Fuel Qualification, Decommissioning Operation.................................... 2 Appendix B Requirements for FSAR/TS Content.................................................................................. 1 Appendix C Example of FSAR Section.................................................................................................. 1 Appendix D Example of Fuel Qualification Report................................................................................ 1 Appendix E Alternative Example of Fuel Qualification Report............................................................. 1 Appendix F Template for Alternative Example of Fuel Qualification Report....................................... 1 to Holtec Letter 5014942 3 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Holtec International Report HI-2210161 iii Project 5014
SUMMARY
OF REVISION Revision 0: Original Issue.
Revision 1: Document updated in response to NRC comments. All changes tracked with revision bars.
Revision 2: Document updated in response to NRC RAIs. All revision bars from Revision 1 were removed All new changes tracked with revision bars, except for Appendix E and F that were newly added to the document.
to Holtec Letter 5014942 4 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 1
Project 5014 Holtec International
1.0 INTRODUCTION
For Dry Storage Systems, 10 CFR 72.236(a) requires a definition of the contents that is qualified to be loaded. The definition of the contents mainly consists of assembly type and condition, and limits on decay heat, and burnup, enrichment, and cooling time (BECT). It also includes specification of non-fuel hardware (NFH), including type, permissible location, and burnup and cooling time. Meeting the requirement of 10 CFR 72.236(a) also supports compliance with 10 CFR 72.236(d), to show that the design is capable of meeting normal and accident dose limits (10 CFR 72.104 and 10 CFR 72.106). The decay heat of the assemblies, and the corresponding limits, are overarching requirement, and while they are not the subject of this TR, they are an important aspect and part of the motivation for this TR. Hence, they are included in the following discussion.
To ensure that applicable temperature limits are met, limits on the decay heat values of the assemblies must be implemented. In the early days of Dry Storage, such limits were identical for each location in the basket of a spent fuel storage cask (uniform loading). However, to optimize the cask loading from both a thermal and dose perspective, more and more sophisticated decay heat limit distributions (thermal loading patterns) within the baskets were developed over time. The culmination of this are thermal loading patterns where limits are defined almost on a cell-by-cell basis. This may be needed to efficiently empty the inventory of an entire spent fuel pool, with its large range of assembly decay heat values, into dry storage systems.
Given the importance of the thermal efficiency, the burnup, enrichment, and cooling time limits must be selected so that they do not result in an additional restriction, unless necessary from a radiological perspective. Expressed differently, the burnup, enrichment and cooling time limits for a given basket cell should correspond to an assembly decay heat equal to or slightly greater than the decay heat limit for that cell.
While this sounds simple as a principal guide, it creates significant complications in its implementation.
This is due to the fact that there is no easy and direct relation between the decay heat and the burnup, enrichment and cooling time of an assembly. Each decay heat value corresponds to an unlimited number of combinations of these parameters, and the combinations related to a single decay heat load value can be very diverse from a radiological perspective. For example, a combination of higher burnup and long cooling time can have the same decay heat as an assembly with short cooling time but much lower burnup, but these two conditions would be very different from a radiological perspective. This conundrum makes an efficient specification of burnup, enrichment, and cooling time limits in the Safety Analysis Report (FSAR), the corresponding Certificate of Compliance (CoC) or Technical Specification (TS) of a system extremely difficult. Two options to approach this, together with their advantages and disadvantages, are as follows:
- 1) Provide a small set of BECTs that would bound all decay heat load values for all assemblies.
a) That approach would be easy from an implementation perspective.
b) However, since dose rates presented in the FSAR are to be calculated using the limiting contents, it would result in excessive dose rates presented there. It would therefore NOT give a correct indication of the dose rates that would be expected for a loaded system. This results in an incorrect to Holtec Letter 5014942 5 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 2
Project 5014 Holtec International characterization of the radiological performance of the system and does not provide the radiation protection departments at the licensees site with any meaningful information.
- 2) Provide extensive lists, in the form of tables of BECTs, or coefficients of equations to calculate BECTs, closely aligned with or informed by the thermal patterns.
a) This results in a significant burden on all parties involved. The FSAR and TS needs to be updated with a significant amount of information, creating effort on the side of the applicant to develop and generate the information and maintain it for the life of the document, and for the NRC to review and approve this information. On the licensees side, it creates a large effort to implement the limits into the site-specific procedures, and to maintain them over time. The information may then also need to be updated with any change to the decay heat patterns.
b) Dose rates would still be overestimated, and most likely by a significant amount. This is because it would be necessary to use the worst BECT for each location in a basket to calculate dose rates, and such condition would still be far away from any realistic BECT distribution. Hence dose rates in the FSAR would still not be representative.
c) Nevertheless, given the comparatively loose connection between BECTs and decay heat values, there could still be assemblies that, based on their operation history, are below the decay heat limit but do not pass the corresponding BECT limits.
d) Overall, this approach requires substantially more effort than the first option but provides comparatively little if any advantages.
This Topical Report (TR) provides an alternative approach to satisfy the regulatory requirement in 10 CFR 72.236(a), and hence also 10 CFR 72.236(d), where the specific contents can be defined in separate qualification reports that are prepared and maintained outside of the FSAR and CoC. For that, limiting dose rates are specified in the FSAR/CoC/TS instead of specifying BECTs, and separate qualification reports then establish the BECTs that assure these dose rate limits are met. Advantages of this approach, for the parties involved, are as follows:
- 1) BECT limits still have to be generated, but they are no longer presented in the FSAR/TS. This reduces the effort on the certificate holders side significantly.
- 2) NRC does not need to approve the complex BECT derivations, only the dose rate limits, which are more directly linked to radiation safety. While the qualification reports are not submitted to NRC for review and approval, they will be available for inspection.
- 3) Licensees may be able to utilize a simplified set of BECT limits more specifically tailored to the fuel they need to load.
Finally, from a safety perspective, the limits in the FSAR or TS, being dose rates, are more closely linked to safety than the BECTs used until now. to Holtec Letter 5014942 6 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 3
Project 5014 Holtec International This document outlines all requirements that need to be satisfied to apply this approach. Deviations from the requirements outlined here are not acceptable, unless specifically mentioned and discussed here. For this, the following terminology is used throughout this report:
shall denotes a requirement that must be satisfied.
should also denotes a requirement, but alternatives are permitted. Only the alternatives discussed are permitted, and the discussions may include criteria that must be satisfied for the alternative to be acceptable.
Throughout this document, two dry storage dockets, HI-STORM 100 [1] and HI-STORM FW [2], are frequently referenced. This was done for simplification, and since these are two of the predominant storage dockets. However, this is not meant to imply that this TR is limited to being applied to these dockets only, it can be applied to any storage docket, as long as the license amendment that would be submitted to include it in a docket addresses all requirement, such as those presented in Appendix B.
2.0 OVERVIEW OF THE APPROACH This topical report defines the overall framework of defining and qualifying content for a dry storage system. The framework consists of several components as follows:
The technical methodology to perform source term calculations for spent fuel and non-fuel hardware.
This methodology is defined in this report, and it is essentially the same as that currently defined in the FSARs for various storage systems. Since it is common to various FSARs, it is defined here to avoid duplication of the approval process.
The technical methodology to perform radiation transport calculations, i.e., to calculate dose rates for a given system and a given content. This is defined in the FSARs for the storage systems. Since it includes modeling details for the respective systems described in the FSAR, and hence is different for each system in that respect, this is not repeated here in order to avoid duplication of the many technical details. This part of the framework will be reviewed and approved as part of the process that includes the reference to this TR in each FSAR/TS. For each system, this technical methodology is also expected to be identical to the methodology that is already presented in each FSAR. Note that the specification of this methodology in the FSAR may limit aspects of the method that can be changed under 72.48. To assure consistency, Appendix B outlines the principal requirements that this technical methodology needs to fulfil in order to be acceptable as part of the process to define content. Appendix C contains an example of the subsection that may be added to an existing FSAR to meet the requirements in Appendix B.
The acceptance criteria, which are dose rate limits at defined locations on the storage system. Since the locations and the limits are specific to each system, they are also defined in the respective FSAR, together with the methodology to calculate dose rates, not in this TR. Nevertheless, this TR contains guidance on the development of those criteria. The criteria would also become part of the TS, so they can only be changed through a license amendment application. Examples are also included in Appendix C. to Holtec Letter 5014942 7 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 4
Project 5014 Holtec International Qualification reports that finally define acceptable content, based on the methodologies and acceptance criteria discussed above. Appendix D contains an example of such a qualification report with a format and content that should be followed for every actual qualification report, with any deviation justified.
Additional examples of qualified content are included in Appendix A.
See Table 2.1 for a brief summary of these different aspects.
The following subsections contain additional clarifications on selected aspects of the approach.
2.1 FSAR vs. Qualification Report A given FSAR/TS may already contain previously established BECT limits to satisfy 10CFR72.236(a) for some given conditions. When updating an FSAR / TS to allow the use of this TR, these could either be retained, or relocated to a qualification report. Relocating them would make for a more consistent approach.
However, if these are already heavily referenced in the licensees documents, it may be easier to retain them in the FSAR/TS.
2.2 Information in the Dry Storage Cask System FSAR/TS To make the method generically applicable to different storage systems, the modeling and design details of the system and the details of the radiation transport analyses to calculate dose rates are not included and discussed in this report. They remain in the corresponding FSAR for each system.
The FSAR contains the descriptions of the systems for which the contents are to be qualified. This includes drawings, relevant design details, and descriptions of calculational models. Important in this respect is the level of detail that needs to be modeled for the calculations to be able to be used for the qualification. Also important is the specification of parameters that are considered inputs, such as material thicknesses of material types and densities, that can be changed (under the purview of 10CFR72.48) when performing the qualification. Part of this modeling description are also the dose point considered important for any given system.
The FSAR (or TS) then specifies the dose rate limits for the selected dose points. This provides the principal limits that the method uses to qualify approved contents. Note that a licensee using the system may elect to use lower dose rate limits to define contents for a specific site. But dose rate limits higher than those specified in the FSAR/TS are not acceptable.
The area of applicability of this TR is discussed in Section 2.8, with details provided in Table 2.2. The FSAR (or TS) may specify additional restrictions, i.e. may limit the applicability to a narrower range of certain parameters than those listed in Table 2.2.
Appendix B contains the principal requirements and guidelines for the information that needs to be defined in the FSAR, with an example in Appendix C. As stated before, the FSAR sections involved in defining to Holtec Letter 5014942 8 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 5
Project 5014 Holtec International these are reviewed and approved in the context of adding the permission to use this TR for defining acceptable content.
2.3 Qualification Reports The evaluations and analyses needed to demonstrate any given set of contents meet the acceptance criteria are documented in qualification reports. These reports define the contents to be qualified, define the system that the contents are to be qualified for, and document the evaluations. They reference this Topical Report for the methodology and the FSAR for details located there.
Qualification reports may be generic in nature, qualifying a range of contents for a larger number of sites where a cask system will be deployed, or may be site-specific, just addressing the specific contents for casks at a single site. The qualification reports do not require NRC review and approval.
Appendix A contains three examples of the analyses that would be performed using the methodology. These are to be used as guidance for the implementation/qualification reports that define the allowable contents.
Appendix D contains a principal example of such a report for a selected storage system and content.
2.4 Design Basis Assemblies It would be certainly possible to model any fuel assemblies accurately in both the source term and the radiation transport analyses. However, such an approach would he highly impractical, not only because it would require an exorbitant number of analyses, but also because previous analyses have shown that the impact of the assembly type, when used consistently in source term and radiation transport analyses, is not that significant. This is due to competing effects of the assembly mass in source term and radiation transport analyses, where a larger mass increases the source term, but also the radiation self-shielding. Hence it is more practical to establish design basis assemblies that are to be used in both source term and radiation transport calculations, to be used for all analyses regardless of the actual assembly type.
The design basis fuel assemblies taken from [1] and [2] and specified in Tables 3.1 and 3.2 may be used in the analyses. For historic reasons, the two FSARs ([1] and [2]) used different design basis fuel assemblies, and both are acceptable to be selected. However, source term calculations and radiation transport calculations that are combined to calculate dose rates for comparison with the dose rate limits shall both use the same design basis fuel. This is necessary so the self-shielding of the fuel assembly matches the source strength, and both depend on the mass of the fuel, which is slightly different between the assemblies in the tables. For both [1] and [2], the design basis assemblies are the assemblies with the higher or highest fuel mass and are used to bound all other assemblies qualified in the respective FSAR. This approach is supported by [9], where studies are presented on the importance of various fuel parameters for dose evaluations. The studies conclude that assemblies with higher fuel mass reasonably bound those with a lower mass. This is the result of the competing effects of source strength and self-shielding being a function of the fuel mass already discussed before, hence not unexpected. Using just one or two design basis assemblies for the entire range of assemblies to be qualified is highly advantageous since it simplifies the qualification effort quite substantially. Having two design basis assemblies for either BWR and PWR is advantageous in the current situation for qualification of assemblies for the storage systems in [1] and [2], to Holtec Letter 5014942 9 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 6
Project 5014 Holtec International since these FSARs already used the different design basis fuel in the development of the radiation transport models, hence these models can be used directly without any modifications.
The design basis assemblies in Table 3.1 and 3.2 can be used without any further justification. A different design basis fuel can also be used, when defined in the FSAR that qualifies the radiation transport analyses for a given system. This aspect has then to be specifically reviewed and approved as part of the license amendment for the corresponding CoC to include the reference to this TR.
2.5 Loading Patterns Inputs to the approach are candidate loading patterns for given casks and baskets, i.e., the fuel assembly types, and limits of burnup, enrichment and cooling times, for each cell in a candidate cask, including specifications of any NFH to be qualified for the cell. These could be generic in nature, i.e. to define patterns useable at various sites for the cask or basket, or could come out of the evaluation of pool inventories for a specific site. However, the development of those patterns is not part of this report and therefore not discussed here. In principle, a pattern could be completely unique, in the sense that every cell in a basket has different limits. For the fuel, the limits could be specified in the form of one or more limiting sets of burnup, enrichment, and cooling times for each basket cell, or in the form of equations that allow the calculations of the limits. For burnups, these will be upper limits, while for enrichments and cooling times these will be lower limits. For NFH, it would include the type, maximum burnup and minimum cooling time. While only a single NFH can be present in any fuel assembly, more than one NFH type may be qualified for a given location in the cask to provide flexibility for loading a larger range of casks. Limits or sets of limits may be applicable to individual cells, groups of cells with the same content limitations (in the following called regions), or the entire cask or basket. Appendix A of this TR provides some hypothetical sets of such limits for a given basket in Tables A.1 and A.3, with regions within the basket specified in Figures A.1 and A.2.
2.6 Acceptance Criteria The principal acceptance criteria used to qualify fuel assemblies are dose rates around the casks.
- 1) Storage systems often consist of the storage cask and a transfer cask. Since these typically have different shielding performance, separate dose rate limits shall be defined for each of these.
- 2) The number and location of dose points will be selected in the FSAR to reasonably represent the contribution of all assemblies in a cask or canister. For example, for a vertical above-ground system, this would include dose locations on the side of the cask (where dose rates are more dominated by the contribution from assemblies on the periphery of the basket), and on the top of the cask lid (where dose rates are more dominated by the contributions in the center of the basket).
Number, location and specific dose rate limits are to be defined in the license amendment request that incorporates this TR into the respective FSAR and TS. These are necessarily specific to the design qualified in the respective FSAR. They are therefore reviewed and approved as part of that license amendment, not as part of this TR. However, for the locations to be consistent with the purpose of defining cask content, the following aspects must be considered when selecting those: to Holtec Letter 5014942 10 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 7
Project 5014 Holtec International Dose locations must be selected to be on or close to the surface of the casks, so the dose rates will be representative of the impact of individual assemblies, not just the average assembly.
Dose points must include areas of the surface/feature where highest dose rates are expected.
o For example, for a vertical above-ground system, this would include dose locations on the side of the cask (where dose rates are more dominated by the contribution from assemblies on the periphery of the basket), and on the top of the cask lid (where dose rates are more dominated by the contributions in the center of the basket).
If any NFH is expected to contribute significantly to the dose rates in certain areas, dose locations in those areas should be included o For example, for a vertical above-ground overpack containing control rod assemblies (CRAs),
side surface points should include points where the activated portions of these components are located, at an axial height where the highest contribution to the side surface dose rates is expected Dose point locations should include those locations that are expected to contribute significantly to off-site dose and to occupational exposures. Different orientations of transfer cask and overpack during different stages of operations ((un)loading, transfer, storage) and for accident conditions need to be considered in that respect.
Dose points need to be sufficient in number to represent the defined content of the cask.
o For uniform loading or symmetric loading conditions (e.g., quadrant, octant), the symmetry may allow a smaller number of dose locations that would be needed compared than for a completely heterogeneous loading.
In the qualification report, a set of dose calculations need to be documented to demonstrate that the content to be qualified meets the dose rates at all defined locations. The extent of this set depends on the specification of the content to be approved as follows The fuel content shall be defined in tables such as those shown for the examples in Appendix A, i.e.
combinations of maximum burnup, minimum enrichments and minimum cooling times for specified basket locations. If the relationships are also specified as an equation, then at least 10 equidistant burnups that cover the range of content to be qualified need to be considered and listed in such a table with the corresponding enrichment and cooling time.
For uniform loading of a cask, all BECTs shall be evaluated.
For regionalized loadings of casks, it is nether practical nor necessary to calculate all possible combinations of BECTs. For example, for the 5 regions in Table A.3, each with 14 BECTs, all combinations would require a total of 145=537,824 dose calculations. Instead, two subsets of dose calculations shall be performed:
o One subset with calculations for each burnup in the BECT table, where each region has fuel with the same burnup, with the corresponding enrichment and cooling time. If no cooling time is specified for a burnup, the next lowest or next highest burnup with a cooling time shall be used, as applicable.
As an example, for the BECTs in Table A.3, this would result in a total of 14 calculations, since 14 burnup values are listed to Holtec Letter 5014942 11 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 8
Project 5014 Holtec International o A second subset of the same size as the first subset, where the BECT in each region is randomly selected from the all the BECT options for that region For the example in Table A.3, this would be again a set of 14 calculations, with a randomly selected burnup in each of the 5 regions, and the corresponding enrichments and cooling times. An example of such a subset is shown in Table A.3.1.
For the example in Table A.1, this approach would have to be repeated 3 times, for each of the cases, i.e. with a total of 3*14=42 calculations. An example of this subset is shown in Table A.1.1 All sets and subsets analyzed shall be listed in the qualification report. But only the maximum dose rates over all analyzed conditions shall be reported.
For NFH, requirements also need to be specified, in the form of maximum burnup values as a function of cooling time. Except for NSAs, NFH only generate gamma dose rates, i.e. the competition between gammas and neutrons that characterize fuel assemblies does not exist. Consequently, bounding gamma source terms shall be developed covering all burnup and cooling time combinations, and considered in all dose evaluations for fuel discussed above. Note that different bounding conditions may be applicable to different dose locations.
2.7 Other Content Restrictions This Topical Report establishes the principal Methodology to technically evaluate and qualify candidate loading patterns that satisfy given dose rate limits. Other restrictions or requirements may exist, for example decay heat limits, as specified in the FSAR or separate documents. None of these other restrictions are considered by the methodology described in this TR, and the conclusion that an assembly with certain burnup, enrichment and cooling time combination meets the dose rate requirements does not imply that it meets any other requirements such as heat load and temperature limits, and vice versa.
2.8 Area of Applicability This topical report is applicable to all US PWR and BWR fuel assemblies that meet the requirements of the area of applicability summarized in Table 2.2. The table also specifies the basis for each parameter. In most cases, the parameter or range of parameters in the table are fixed, i.e. the TR can only be used if the parameters in the analyses match the parameter or parameter range in the table. However, for selected parameters, as clarified in the notes to the table, parameters outside the specified range can be acceptable under certain conditions. These conditions are then specified in the corresponding section referenced in the table.
For its use for a specific storage system, this report needs to be referenced in the respective CoC/TS of the system. The FSAR/TS that the TR is referenced in may specify additional restriction, i.e. only allow a subset of fuel characterized in Table 2.2. to Holtec Letter 5014942 12 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 9
Project 5014 Holtec International Some of the requirements in Table 2.2 have a simple basis, while others require additional considerations and discussions. The simple bases are listed below, followed by separate subsections for the parameters that need additional considerations.
Only UO2-based fuel can be qualified through the method defined here. That does not introduce any significant restriction since MOX fuel is currently not utilized in US plants. However, if they ever would be used, they would be excluded from being qualified through this TR.
Only zirconium cladded fuel can be qualified through the method defined here. This does also not pose any significant restrictions, since the vast majority of fuel has zirconium-based cladding.
Burnup and enrichment ranges are defined by the limits in the predefined libraries in the source term code (see Section 3).
Fuel types cover all types used in US BWR and PWR plants The cooling time limit for spent fuel is taken from 10CFR72.
The condition of the fuel, e.g. undamaged, damaged, fuel debris, reconditioned, reconstituted fuel, affects predominantly the spatial distribution of the fuel in the dry storage system for the radiation transport calculations, but not the source term calculations which are still depending on burnup, enrichment and cooling time and any core conditions. Since this TR only specifies the methodology for the source term generation, and the radiation transport calculations are addressed in the corresponding FSAR/TS, there are no restrictions on the fuel conditions that need to be considered in this TR.
Other fuel operation parameters are considered to be of low importance as discussed in [9]. Nevertheless, acceptable parameters or parameter ranges are defined in the Table, to clarify the limits of the use of this TR. In practicality, these parameters and parameter ranges are not expected to limit the use of this TR for standard US fuel assemblies.
The following subsections discuss the basis for other parameters. If necessary, these discussions also provide the basis for the value or values listed in Section 3 that should be used in the analyses.
This range is based on information from [10]. It is noted that the cycle-average soluble boron level for PWR is typically well below the maximum. However, under certain circumstances, assemblies may only be irradiated for part of a cycle, and hence be exposed to a higher soluble boron level.
Since the impact of the soluble boron on dose rates is minor, the TRITON libraries from [8] shall be used with their respective soluble boron specification.
2.8.2 Exposure to NFH (PWR)
During in-core operation, fuel assemblies may have NFH inserted into the guide tubes. This may locally and/or temporarily reduce the amount of water in the assembly, and/or provide additional absorption of thermal neutrons, both of which would harden the spectrum, and hence potentially affect the source terms determined for the assembly. This is different from the effect of NFH during the storage operation, which to Holtec Letter 5014942 13 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 10 Project 5014 Holtec International is concerned about the dose contribution from the NFH themselves. The different types of NFH are discussed separately below.
TPDs (also called ORAs, but both characterized as TPDs in this report). These are only present near the top of the assembly, typically not reaching into the active region. The effect of these on the source term of the assembly is therefore considered negligible.
Burnable poison rods. Their effect was evaluated in [9], and also found to be very low. Additionally, these would only be present in a fraction of the assemblies, and only for a limited time, typically 1 irradiation cycle, for an assembly. Overall, their impact on the source terms can therefore be neglected.
Control Rod Assemblies. These would have a stronger neutron absorption than the burnable poison rods discussed above. However, the majority of those are for shutdown operation, and never be inserted into the active region during full-power operation, and those used for power control would only be marginally inserted into the active region, so as to not negatively affect the plant efficiency and stability
[10]. The allowed insertion is also tightly controlled by the plant operating procedures. Hence these can also be considered not significant enough to be modeled for the source term operation.
Axial Power Shaping Rods. Their neutron absorption material has less of an absorption capability than that of the control rods assemblies, but they are present in the active region. However, they are only present in a small number of assemblies in the core, and only for a limited time, hence they are considered similar in the effect to the burnable poison rods.
Overall, there is considered reasonable to neglect the effect of the NFH for the in-core-operation, and hence fuel assemblies irradiated with any type of NFH are permitted for storage.
2.8.3 Exposure to Control Components (BWR)
Similar to the discussion on control assemblies for PWR assemblies in the previous subsection, BWR control components are used for shutdown and power control, with insertion limited with respect to duration and insertion depth [10]. Their effect is therefore also considered not significant, and no restrictions are placed for those.
2.8.4 Water Density PWR The in-core water density for PWR plants is a direct function of the pressure and average moderator temperature in the core, both of which only show minor variations between typical PWR plants; hence the density also only varies slightly. The range specified encompasses typical moderator temperatures. Due to the small variation, the source term analyses shall utilize the TRITON libraries, with the density used in each library, without any further adjustments.
2.8.5 Water Density BWR The water density for BWR assemblies varies much more than that of PWR fuel, both over the irradiation history of an assembly, and also spatially, over the height of the assembly. Information in [10] and [11]
show that it can vary from about 0.1 to about 0.75 g/cm3, and TRITON libraries cover from 0.1 to 0.9 g/cm3.
However, utilizing densities changing with time or location is not the intent, so using a reasonable average to Holtec Letter 5014942 14 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 11 Project 5014 Holtec International is sufficient. Since a lower value is a more conservative assumption, the lower value of 0.3 listed in [9]
shall be used for the source term analyses here.
2.8.6 Fuel Density Typically, fuel densities are kept close to the theoretical maximum of 10.96 g/cm3, for efficiency purposes.
However, in practicality, densities are somewhat lower, due to dishing and chamfering of the fuel pellets, and the limitations in the manufacturing process, no more than about 96% of that value. Older assemblies may have had even lower density, potentially below 10 g/cm3. The density affects the fuel to water ratio, and in this case, a higher value would be more conservative since it would result in a harder spectrum. Due to the small range of the density, the effect on source terms would not be significant. For the applicability, a generous range is therefore defined, and for the calculations, a fixed value of about 95% of the theoretical maximum should be used regardless of the fuel type, unless site or fuel specific values are available, then these may be used. However, these site or fuel specific values must be within the range listed in Table 2.2.
2.8.7 Specific Power In [9], it is concluded that higher specific power values are more conservative, and for PWR fuel, values in the range of 20 to 40 MW/mtU are listed as realistic and typical values. In [1] and [2], values of about 40 MW/mtU are used for PWR assemblies, and 30 MW/mtU for BWR fuel. These are realistic and typical for most assemblies, specifically if they are fully burned, but individual assemblies in a core may have slightly higher values, specifically for assemblies irradiated for just a limited number of cycles before the plant shutdown. For such assemblies, separate source term calculations shall be performed using a bounding specific power density. This must then be documented in the qualification report.
2.8.8 Fuel (Uranium) Mass The fuel (Uranium) mass has a very small effect on dose rates, due to a compensatory effect between source term and radiation transport calculations. A higher mass results in higher source terms, which would tend to increase dose rates, but then also in higher self-shielding withing the cask, which would tend to reduce dose rates. The range specified in Table 2.2 is therefore the range from [1] and [2], slightly extended to account for variations in actual values. The important aspect is that for consistency between source term and radiation transport calculations, the mass in the radiation transport calculations cannot be more than that in the source term calculation for a specific fuel assembly. For that reason, the design basis fuel assemblies as presented in Section 3 should be used for all assemblies, including assemblies with lower uranium weight, to avoid multitudes of radiation transport analyses. However, it is acceptable to use site-specific uranium weights instead. In that case, this shall be documented in the qualification report, and it must be ensured that both the source term and radiation transport analyses are based on the same mass value. See also next section.
2.8.9 Fuel Condition The condition of the fuel, e.g., undamaged, damaged, fuel debris, reconditioned, reconstituted fuel, affects predominantly the spatial distribution of the fuel in the dry storage system for the radiation transport calculations, but not the source term calculations which are still depending on burnup, enrichment and to Holtec Letter 5014942 15 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 12 Project 5014 Holtec International cooling time and any core conditions. Since this TR only specifies the methodology for the source term generation, and the radiation transport calculations are addressed in the corresponding FSAR/TS, there are no restrictions on the fuel conditions that need to be considered in this TR.
For some of the fuel conditions, the uranium weights may be lower than that of an undamaged assembly.
When considering this in both the source term and radiation transport analyses, this may have some impact on external dose rates. However, due to the compensatory effect discussed in the previous section, the effect would be limited. Hence it is acceptable to model all assemblies as undamaged in both the source term and radiation transport analysis.
to Holtec Letter 5014942 16 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 13 Project 5014 Holtec International Table 2.1
SUMMARY
OF THE ASPECTS OF THE FRAMEWORK AND METHODOLOGY Information Document Location Owner Change Control Acceptance Criteria Dose Rates Technical Specifications NRC Only via Amendment Source Term Calculation Methodology This Topical Report CoC Holder Only via Application Radiation Transport (Dose Rate)
Calculation Methodology FSAR CoC Holder Strict 10CFR72.48 Method of Evaluation Controls Acceptable Content Qualification Report CoC Holder /
Licensee Available to NRC for information, but not for approval to Holtec Letter 5014942 17 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 14 Project 5014 Holtec International Table 2.2 AREA OF APPLICABILITY (Note 1)
Parameter Applicability Basis Fuel Spent PWR and BWR fuel
[1], [2]
Fuel Burnup Up to 72 GWd/mtU for PWR fuel Up to 72 GWd/mtU for BWR fuel TRITON Libraries [8]
Fuel Type UO2 Limitation set in this TR Fuel Assembly Hardware Standard fuel assembly hardware (upper and lower end fittings, guide tubes or water rods, grid straps, etc, made from steel, zirconium alloy, or Inconel).
Assemblies may also contain irradiated or unirradiated steel or zirconium alloy rods in fuel rod locations.
See Section 3, specifically Section 3.2.2 for replacement rods Non-Fuel-Hardware for PWR assemblies Burnable Poison Rod Assemblies (BPRAs),
Thimble Plug Devices (TPDs, also called ORAs),
Control Rod Assemblies (CRAs), Axial Power Shaping Rods (APSRs), Wet Annular Burnable Absorbers (WABAs), Rod Cluster Control Assemblies (RCCAs), Control Element Assemblies (CEAs), Neutron Source Assemblies (NSAs),
water displacement guide tube plugs, orifice rod assemblies, instrument tube tie rods (ITTRs),
vibration suppressor inserts, and components of these devices such as individual rods.
Activated material in the NFH may be zirconium alloys, steel, Inconel, AgInCd or Hafnium.
[1], [2], and Section 3 of this report Enrichment 0.5 wt% to 5.0 wt% 235U
[1], [2] and range of TRITON Libraries [8].
For enrichment variations see Section 3.6 of this report to Holtec Letter 5014942 18 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 15 Project 5014 Holtec International Cooling Time Greater or equal to 1 year 10 CFR 72 In-Core Cycle Average Soluble Boron 0 to 2000 ppm
[10]
See Section 2.8.1 of this report In-Core exposure to control components All NFH listed above, without any restriction See Section 2.8.2 and Section 2.8.3 of this report Water Density BWR 0.1 to 0.9; PWR 0.7 to 0.75 See Section 2.8.4 and Section 2.8.5 of this report Fuel Density 9.0 to 10.96 See Section 2.8.6 of this report Specific Power up to 40 MW/mtU for PWR, up to 30 MW/mtU for BWR, without further justification. See Note 2.
See Section 2.8.7 of this report Fuel arrays BWR: 7x7 to 11x11, PWR: 14x14 to 17x17
[1], [2]
Fuel Mass (Uranium)
BWR: up to 205 kg; PWR up to 575 kg. See Note
- 2.
See Section 2.8.8 of this report Fuel condition Undamaged, damaged, fuel debris, reconstituted, reconfigured See Section 2.8.9 of this report Fuel Cladding Zirconium based only Limitation set in this TR Note 1: The FSAR that this TR is referenced in may specify more restrictive values for some parameters Note 2: Fuel with values outside this range can be qualified but require separate source term analyses. See Section 2.8.7 and Section 2.8.8 for details.
to Holtec Letter 5014942 19 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 16 Project 5014 Holtec International 3.0 SOURCE TERM EVALUATIONS FOR QUALIFICATION OF FUEL 3.1 General This section specifies the requirements for performing the source term analyses for the dose rate calculations to qualify fuel in accordance with this Topical Report. This methodology is principally the same as those defined in the FSARs for the various storage systems. Since it is common to various FSARs, it is defined here to avoid duplication of the approval process.
The code to calculate neutron and gamma source terms shall be the ORIGAMI module of the SCALE system, Version 6.2.1 [7] or higher, utilizing the TRITON data libraries supplied with the respective code version. The calculations shall be utilizing the data libraries with the maximum number of energy groups available for the respective code version. For SCALE 6.2.1, this is the 252-group library based on ENDF/B-VII.1 nuclear data. ORIGAMI and TRITON data libraries from SCALE 6.2.1 can be used without further justification. When using a newer version of the SCALE code, it shall be demonstrated, for a small set of BECTs that span the variations of the burnups and cooling times to be qualified, that the results (dose rates) are within 5% of those from SCALE Version 6.2.1. The value of 5% is a typical value for uncertainties of the radiation transport analyses, so any source terms from a different code version that keep the dose rate results within that 5% variation would indicate that the source terms are essentially the same as those from SCALE Version 6.2.1. These dose calculations to qualify a newer version shall be performed for the storage and transfer cask for which the fuel is to be qualified. The small set of BECTs shall be the same as that selected as representative in the corresponding FSAR (see Appendix A), i.e. one combination with shortest cooling time and corresponding lower burnup, and one combination with highest burnup and corresponding longer cooling times, both consistent with the dose rate limits specified, and using enrichments consistent with the burnups.
For SCALE 6.2.1, the TRITON libraries [8] supplied with the code as specified in Table 3.1 and 3.2 shall be used.
When performing the ORIGAMI calculations, a single full power cycle shall be used to achieve the desired burnup, since this has been shown to result in conservative source terms relative to actual multicycle power operation.
Source term calculations shall be performed for the design basis assemblies listed in either Table 3.1 or Table 3.2, which have been shown in [1] to reasonably bound all assembly types in the corresponding FSARs.
3.2 Gamma Source The gamma source term is comprised of three distinct sources. The first is a gamma source term from the active fuel region due to decay of fission products. The second source term is from 60Co activity of any structural material in the fuel element, in the active region and above and below the active fuel region. to Holtec Letter 5014942 20 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 17 Project 5014 Holtec International These sources are determined through the source term calculations outlined here. The third source is from n-gamma reactions. This third source shall be considered directly in the radiation transport calculations.
3.2.1 Gamma Source from Fuel Previous analyses (see Reference [1]) indicated that it is appropriate and necessary to include all photons with energies in the range of 0.45 to 3.0 MeV. Photons with energies below 0.45 MeV are too weak to penetrate the typical shielding constructions, while the effect of gammas with energies above 3.0 MeV was found to be insignificant since the source of gammas in this range (i.e., above 3.0 MeV) is extremely low.
To appropriately consider spectral effects, i.e., differences of source terms as a function of the gamma energy, a sufficiently fine energy group structure shall be used in the analyses. There are two options for selecting this energy structure:
Use the energy structure from Table 3.5, taken from Reference [1]. The same energy structure must be used in the radiation transport analyses.
Alternatively, the energy structure can be defined in the FSAR that documents the qualification of the radiation transport analyses. This source structure must then also be used in the source term calculations, and the structure must again be identical between source term and radiation transport analyses The radiation transport analyses should apply the gamma source terms from the active region as a histogram, i.e. with equal probability of particle energies within each energy group.
3.2.2 Gamma Source from Activation of Non-Fuel Materials An important source of activity in the fuel assembly arises from the activation of 59Co to 60Co in various non-fuel materials and components. These include the structural material above and below the fuel, guide tubes, water rods, channel boxes, and grid spacers, hold-down springs, etc. Additionally, assemblies may include irradiated metal rods that have been inserted to replace fuel rods with damaged cladding, or that have been part of the initial fuel assembly design. If any of these components are made from steel or Inconel, the activity can be substantial, and must be considered in the source term evaluation. If they are made from zircaloy, they can be neglected since it does not have a significant 59Co impurity level. Reference [3]
indicates that the impurity level in steel is 800 ppm or 0.8 gm/kg. This impurity level is considered conservative for fuel which has been manufactured since the mid-to-late 1980s after the implementation of an industry wide cobalt reduction program. Based on this, Inconel and stainless steel in the non-fuel regions shall both be modeled with 1.0 gm/kg impurity level for fuel manufactured in or after 1990. However, The zircaloy in these regions, and in the active region of the fuel, can be neglected since it does not have a significant 59Co impurity level. it is recognized that materials used in earlier assemblies may have had higher impurity levels, with up to 2.2 gm/kg for steel and 4.7 gm/kg or more for Inconel. While such assemblies would now have undergone significant decay and corresponding reduction of the 60Co source terms, these values should be used for assemblies manufactured before 1990 to assure the analyses are reasonably conservative. Lower values may be used if documented records for those values are available. to Holtec Letter 5014942 21 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 18 Project 5014 Holtec International These records will then need to be referenced in the qualification report, and the qualification would be limited to the assemblies that these records apply to.
Some of the fuel assembly designs utilized Inconel in-core grid spacers while others use zircaloy in-core grid spacers. In the mid-1980s, the fuel assembly designs using Inconel in-core grid spacers were redesigned to use zircaloy in-core grid spacers, which contain an insignificant amount of 59Co. Source term calculations can be performed with or without considerations of Inconel grid spacers. Considering the presence of Inconel spacers bounds any type of spacers. If Inconel spacers are not considered, this shall be clearly stated in the qualification report, and the qualification can then only be used for fuel that does not contain them.
The non-fuel data listed in Table 3.1 were taken from References [3], [4], and [5].
In addition to the 59Co activation, activated materials in CRAs may create an additional gamma source.
CRAs are fabricated of various materials. The cladding is typically stainless steel, although Inconel has been used. The absorber can be a single material or a combination of materials. AgInCd is possibly the most common absorber although B4C and hafnium has also been used. AgInCd produces a noticeable source term in the 0.3-1.0 MeV range due to the activation of Ag. The source term from the other absorbers is negligible, therefore the AgInCd CRAs are the bounding CRAs that shall be used.
There are principally two ways to evaluate the source terms for these activations, which are selected and used in combination with the way they are applied in the radiation transport analyses to calculate the dose rates:
For the non-fuel materials that are always present in active region of the fuel, the materials will be considered directly in the ORIGAMI calculations, using the nonfuel and optional fracnf keywords (see Section 3.5). Through this, the activity of these materials is directly included in the gamma source term of the fuel assembly, and can then be directly considered in or combined with the results of the radiation transport analysis.
For other non-fuel hardware that is present in every assembly but not in the active regions (e.g., top and bottom end fittings), or that may not be present in every assembly (e.g., NFH, steel rods, Inconel spacers), it is not practical to perform separate ORIGAMI calculations for each piece of hardware since that would complicate the application of the corresponding source terms in the radiation transport analysis. Instead, the source term for a fixed amount (e.g., 1 g of 59Co, 1kg of AgInCd) is calculated, and then the source from each piece of hardware can be determined from the corresponding source term, the amount of the material in that piece (Tables 3.1, 3.2, 3.4, 3.7 or 3.8, as applicable), and the applicable flux factor (Table 3.3, Table 3.7 or Table 3.8, as applicable), and assigned to the appropriate location in the dose evaluation.
Typically, the mass of NFH devices is not considered in the radiation transport analyses as additional shielding. This is a conservative approach since it neglects material that would provide some additional shielding. If any credit for these masses is taken, then this must be justified in the FSAR describing the radiation transport analyses, and reviewed and approved as part of the corresponding CoC approval.
to Holtec Letter 5014942 22 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 19 Project 5014 Holtec International 3.3 Fuel Neutron Source The neutron source strength increases as enrichment decreases, for a constant burnup and decay time. This is due to the increase in Pu contents in the fuel, which increases the inventory of other transuranium nuclides such as Cm. Because of this effect and in order to obtain conservative source terms, lower bound initial fuel enrichments shall be used in the analyses.
As for gamma sources, neutron source terms shall be generated by energy group in a suitable group structure. The same approach is applicable here that was discussed in Section 3.2.1 for gamma source terms, with the energy group structure for Neutrons from Reference [1] presented in Table 3.6.
The radiation transport analyses should apply the neutron source terms from the active region as a histogram, i.e., with equal probability of particle energies within each energy group.
3.4 Non-Fuel Hardware Burnable poison rod assemblies (BPRAs), thimble plug devices (TPDs), control rod assemblies (CRAs),
axial power shaping rods (APSRs) and neutron source assemblies (NSAs) are permitted for storage as an integral part of a PWR fuel assembly. If they are used, their source terms shall be evaluated based on the specifications below, and considered in the radiation transport analyses.
The burnup assigned to a NFH is the burnup that a fuel assembly accumulates while the NFH is inserted.
If the NFH was present in several assemblies, as would have been typically the case for TPDs, CRAs, APSRs, and NSAs, the burnup assigned to the NFH is the addition of those burnups. It would be impractical to prepare separate source term calculations for each such NFH, with the applicable sequence of burnup exposures. Instead, a single calculation may be used with an upper bound burnup and corresponding cooling time, or a set of calculations with different burnups and corresponding cooling time limits. In all cases, the flux from the assembly shall be reset every 45 GWd/mtU in the calculation. There is no principal limit to the accumulated burnups of NFHs, hence no limits are specified in Table 2.2. However, the qualification report shall specify the burnup and cooling time combination(s) that are evaluated, and only NFH that meet these burnup and cooling time combination(s) are qualified for loading.
The specifications in the tables at the end of this section are considered reasonable and mostly conservative for determining source terms for typical fuel assemblies and NFH, specifically with respect to the amounts and axial configurations of irradiated material. If there are any indications that the amounts of components to be qualified are significantly higher from those, the differences need to be evaluated, source terms need to be adjusted accordingly, and this is to be documented in the qualification report. This adjustment would be made in the consideration of the NFHs as described in Section 3.2.2.
3.4.1 BPRAs and TPDs Burnable poison rod assemblies (BPRA) (including wet annular burnable absorbers) and thimble plug devices (TPD) (including orifice rod assemblies, guide tube plugs, and water displacement guide tube to Holtec Letter 5014942 23 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 20 Project 5014 Holtec International plugs) are an integral, yet removable, part of a large portion of PWR fuel. The TPDs are not used in all assemblies in a reactor core but are reused from cycle to cycle. Therefore, these devices can achieve very high burnups. In contrast, BPRAs are burned with a fuel assembly in core and are not reused. In fact, many BPRAs are removed after one or two cycles before the fuel assembly is discharged. Therefore, the achieved burnup for BPRAs is not significantly different from that of a fuel assembly. Vibration suppressor inserts are considered to be in the same category as BPRAs for the purposes of this source term analyses since these devices have the same configuration (long non-absorbing thimbles which extend into the active fuel region) as a BPRA without the burnable poison.
TPDs are made of stainless steel and may contain a small amount of Inconel. These devices extend down into the plenum region of the fuel assembly but typically do not extend into the active fuel region. Since these devices are made of stainless steel, there is a significant amount of 60Co produced during irradiation.
This is the only significant radiation source from the activation of steel and Inconel.
BPRAs are made of stainless steel in the region above the active fuel zone and may contain a small amount of Inconel in this region. Within the active fuel zone, the BPRAs may contain 2-24 rodlets which are burnable absorbers clad in either zircaloy or stainless steel.
Since the systems are designed to store many varieties of PWR fuel, a representative TPD and BPRA was determined for the purposes of the analysis. This was accomplished by analyzing BPRAs and TPDs (Westinghouse and B&W 14x14 through 17x17) found in references [5] and [6] to determine the TPD and BPRA which produced the highest 60Co source term for a specific burnup and cooling time. The TPD was determined to be the Westinghouse 17x17 guide tube plug and the BPRA was determined by combining the higher masses of the Westinghouse 17x17 and 15x15 BPRAs into a single hypothetical BPRA. The masses of these devices are listed in Table 3.4. These should be used in the source term calculations, and in this case no further justification is needed. If masses different from those in Table 3.4 are used, the different masses need to be established and reviewed in the context of the FSAR that supports the CoC amendment to include the use of this TR.
Note further that since inserts are managed and handled separately from the fuel, the burnup and cooling time of an insert in an assembly may be different from that of the assembly.
3.4.2 CRAs and APSRs Control rod assemblies (CRAs) (including control element assemblies and rod cluster control assemblies) and axial power shaping rod assemblies (APSRs) are also an integral, yet removable, portion of a PWR fuel assembly. These devices are utilized for many years (upwards of 20 years) prior to discharge into the spent fuel pool. The manner in which the CRAs are utilized vary from plant to plant. Some utilities maintain the CRAs fully withdrawn during normal operation while others may operate with a bank of rods partially inserted (approximately 10%) during normal operation. Even when fully withdrawn, the ends of the CRAs are present in the upper portion of the fuel assembly since they are never fully removed from the fuel assembly during operation. The result of the different operating styles is a variation in the source term for the CRAs. In all cases, however, only the lower portion of the CRAs will be significantly activated.
Therefore, when the CRAs are stored with the PWR fuel assembly, the activated portion of the CRAs will to Holtec Letter 5014942 24 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 21 Project 5014 Holtec International be in the lower portion of the cask. CRAs are fabricated of various materials. The cladding is typically stainless steel, although Inconel has been used. The absorber can be a single material or a combination of materials. AgInCd is possibly the most common absorber although B4C and hafnium has also been used.
AgInCd produces a noticeable source term in the 0.3-1.0 MeV range due to the activation of Ag. The source term from the other absorbers is negligible, therefore the AgInCd CRAs are the bounding CRAs that shall be used.
APSRs are used to flatten the power distribution during normal operation and as a result these devices achieve a considerably higher activation than CRAs. There are two types of B&W stainless steel clad APSRs: gray and black. According to reference [5], the black APSRs have 36 inches of AgInCd as the absorber while the gray ones use 63 inches of Inconel as the absorber. Because of the 60Co source from the activation of Inconel, the gray APSRs produce a higher source term than the black APSRs and therefore are the bounding APSR and shall be used.
The materials and corresponding masses listed in Table 3.7 and Table 3.8 shall be used in the source term calculations. These are based on a review of publicly available fuel information and are considered reasonable and sufficiently conservative.
The assumed insertion of CRAs of 10% during the entire irradiation is considered extremely conservative, since only a fraction of CRAs is permitted to be inserted into the active region at any given time during power operation, and since the insertion depth is limited and tightly controlled for both efficiency and stability reasons. However, if there are indications that individual CRAs have been inserted, on average, more than 10% into the active region, then this shall be considered in both the source term calculations for this, and the corresponding radiation transport analyses. This adjustment would result in a modification of the values in Table 3.7, as follows:
The first row represents the depths (second and third column) and masses (fifth and sixth column) of the 10% insertion. These values have to be multiplied by the ratio of the next insertion to the 10%
assumption.
Then start and finish values for the 2 following rows have to be adjusted in accordance with the new insertion length.
3.4.3 Discrete Neutron Source Neutron source assemblies (NSAs) are used in reactors for startup. There are different types of neutron sources (e.g., californium, americium-beryllium, plutonium-beryllium, polonium-beryllium, antimony-beryllium). These neutron sources are typically inserted into the guide tubes of a fuel assembly and are usually removable.
The neutron source term of these neutron source is usually negligible compared to those from fuel assemblies, specifically for the secondary sources. However, for some primary sources that may not be the case. Hence one of the following three options shall be used to consider the neutron source strength from NSAs: to Holtec Letter 5014942 25 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 22 Project 5014 Holtec International If an evaluation is performed that shows that the neutron source term from an NSA is negligible, there is no limit on the number or location of NSAs in the basket. The contribution can be considered negligible if an NSA present in all assemblies provides less than 1% of the total neutron source term of a cask.
o This may be the preferred approach for antimony-beryllium source. In these, the neutron production is driven by the antimony decay, which as a half-life of only 60 days, hence the generation can be shown to be negligible after just a few years of cooling time.
If the neutron source term of the NSA is not negligible but is quantified, it can be considered in the analyses to show compliance with the dose rate limits. In that case, the number and location of the NSAs qualified becomes part of the qualified content.
If no evaluation is performed, only one NSA is permitted in a basket, and shall be located near the center of that basket, consistent with the approach in Reference [1].
Additionally, the stainless steel and Inconel portions of the NSAs become activated during in-core operations, potentially producing a significant amount of 60Co. Their design resembles a combination of a BPRA and a TPD. They typically contain a limited number of full-length rods (similar to a BPRA), with thimble plugs for the remainder of the guide tube positions that do not contain a full-length rod. For the source term calculations, they shall be considered a combination of the masses for the TPD (Table 3.4),
combined with the in-core mass for a BPRA (also Table 3.4), but where this mass is scaled down proportional to the number of full-length rods in the NSA.
3.5 ORIGAMI Calculations There are numerous modeling and parameter options for performing ORIGAMI calculations. For the purpose of the source term calculations in accordance with this TR, it is sufficient to use the modeling option for a fully lumped assembly. The principal structure of an input file for such a calculation is shown in Table 5.4.1 of [7], although parameters may be different. The keywords and parameters that must be present are discussed below, unless specified as optional. For any ORIGAMI parameters not specified below, the code appropriately uses the default values stated in [7].
Keyword Parameter Comment libs TRITON Library see Table 3.1 fuelcomp fuel composition use uox() with enrich= and dens= specification options / mtu fuel weight uranium weight only options / fracnf total non-fuel mass as fraction of fuel mass optional, may simplify non-fuel specification to Holtec Letter 5014942 26 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 23 Project 5014 Holtec International pz and meshz axial configuration for a lumped assembly, pz=1 or omitted, meshz=any arbitrary number of omitted nonfuel combined composition of all nonfuel material in the active region must include fuel cladding, guide tubes, water rods, grid straps, steel rods (if applicable), channel (BWR), all using their representative material composition, and cobalt content hist / cycle cycle information only one cycle with a power>0 nlib should be set so the burnup steps are no more than about 5 GWd/mtU ggrp and ngrp energy group boundaries see Section 3.2 and 3.3 modz moderator density BWR only, see Section 2.8.5 print various optional to generate additional output tables.
3.6 Fuel Assemblies with Axial Blankets Some assemblies contain axial blankets, i.e., small sections at the top and bottom of the assemblies that have reduced enriched or natural uranium. How such assemblies are considered in the dose analyses, including the selection of the relevant burnup and enrichment parameters of the assembly, depends on the modeling approach taken in the radiation transport analyses. Since the modeling of the radiation transport analyses are part of the FSAR, not this TR, the modeling approach for blanketed assemblies and the definition of the relevant burnup and enrichment characteristics will be part of the review and approval of the CoC that incorporates the reference of this TR.
to Holtec Letter 5014942 27 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 24 Project 5014 Holtec International Table
3.1 DESCRIPTION
OF DESIGN BASIS ZIRCALOY CLAD FUEL PWR BWR Assembly type/class WE 1717 GE 1010 Active fuel length (in.)
144 144 No. of fuel rods 264 92 Rod pitch (in.)
0.496 0.51 Cladding material Zircaloy-4 Zircaloy-2 Rod diameter (in.)
0.374 0.404 Cladding thickness (in.)
0.0225 0.026 Pellet diameter (in.)
0.3232 0.345 Pellet material UO2 UO2 Specific power (MW/MTU) 43.48 30 Weight of UO2 (kg) 532.150 213.531 Weight of U (kg) 469.144 188.249 No. of Water Rods/ Guide Tubes 25 2
Water Rod/ Guide Tube O.D. (in.)
0.474 0.98 Water Rod/ Guide Tube Thickness (in.)
0.016 0.03 Lower End Fitting (kg) 5.9 (steel) 4.8 (steel)
Gas Plenum Springs (kg) 1.150 (steel) 1.1 (steel)
Gas Plenum Spacer (kg) 0.793 (Inconel) 0.841 (steel)
N/A Expansion Springs (kg)
N/A 0.4 (steel)
Upper End Fitting (kg) 6.89 (steel) 0.96 (Inconel) 2.0 (steel)
Handle (kg)
N/A 0.5 (steel)
Incore Grid Spacers (kg) 4.9 (Inconel) 0.33 (Inconel springs)
TRITON Library for SCALE 6.2.1
[7], [8]
w17x17 ge10x10-8 to Holtec Letter 5014942 28 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 25 Project 5014 Holtec International Table
3.2 DESCRIPTION
OF ALTERNATIVE DESIGN BASIS ZIRCALOY CLAD FUEL PWR BWR Assembly type/class B&W 1515 GE 77 Active fuel length (in.)
144 144 No. of fuel rods 208 49 Rod pitch (in.)
0.568 0.738 Cladding material Zircaloy-4 Zircaloy-2 Rod diameter (in.)
0.428 0.570 Cladding thickness (in.)
0.0230 0.0355 Pellet diameter (in.)
0.3742 0.488 Pellet material UO2 UO2 Specific power (MW/MTU) 40 30 Weight of UO2 (kg) 562.029 225.177 Weight of U (kg) 495.485 198.516 No. of Water Rods 17 0
Water Rod O.D. (in.)
0.53 N/A Water Rod Thickness (in.)
0.016 N/A No. of Water Rods 17 0
Water Rod O.D. (in.)
0.53 N/A Water Rod Thickness (in.)
0.016 N/A Lower End Fitting (kg) 8.16 (steel), 1.3 (Inconel) 4.8 (steel)
Gas Plenum Springs (kg) 0.48428 (Inconel). 0.23748 (steel) 1.1 (steel)
Gas Plenum Spacer (kg) 0.82824 N/A Expansion Springs (kg)
N/A 0.4 (steel)
Upper End Fitting (kg) 9.28 (steel) 2.0 (steel)
Handle (kg)
N/A 0.5 (steel)
Incore Grid Spacers (kg) 4.9 (Inconel) 0.33 (Inconel springs)
TRITON Library for SCALE 6.2.1 [7], [8]
bw15x15 ge7x7-0 to Holtec Letter 5014942 29 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 26 Project 5014 Holtec International Table 3.3 SCALING FACTORS USED IN CALCULATING THE 60Co SOURCE Region PWR BWR Handle N/A 0.05 Upper End Fitting 0.1 0.1 Gas Plenum Spacer 0.1 N/A Expansion Springs N/A 0.1 Gas Plenum Springs 0.2 0.2 Incore Grid Spacer 1.0 1.0 Lower End Fitting 0.2 0.15 to Holtec Letter 5014942 30 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 27 Project 5014 Holtec International Table
3.4 DESCRIPTION
OF DESIGN BASIS BURNABLE POISON ROD ASSEMBLY AND THIMBLE PLUG DEVICE Region BPRA TPD Upper End Fitting (kg of steel) 2.62 2.3 Upper End Fitting (kg of Inconel) 0.42 0.42 Gas Plenum Spacer (kg of steel) 0.77488 1.71008 Gas Plenum Springs (kg of steel) 0.67512 1.48992 In-core (kg of steel) 13.2 N/A to Holtec Letter 5014942 31 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 28 Project 5014 Holtec International Table 3.5 Energy Structure for Developing Fuel Gamma Source Terms Lower Energy Upper Energy (MeV)
(MeV) 0.45 0.7 0.7 1.0 1.0 1.5 1.5 2.0 2.0 2.5 2.5 3.0 Table 3.6 Energy Structure for Developing Neutron Source Terms Lower Energy (MeV)
Upper Energy (MeV) 1.0e-01 4.0e-01 4.0e-01 9.0e-01 9.0e-01 1.4 1.4 1.85 1.85 3.0 3.0 6.43 6.43 20.0 to Holtec Letter 5014942 32 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 29 Project 5014 Holtec International Table
3.7 DESCRIPTION
OF DESIGN BASIS CONTROL ROD ASSEMBLY CONFIGURATIONS FOR SOURCE TERM CALCULATIONS Axial Dimensions Relative to Bottom of Active Fuel1 Flux Weighting Factor Mass of cladding (kg Inconel)
Mass of absorber (kg AgInCd)
Start (in)
Finish (in)
Length (in) 0.0 15.0 15.0 1.0 1.32 7.27 15.0 18.8 3.8 0.2 0.34 1.85 18.8 28.25 9.45 0.1 0.83 4.57 Table
3.8 DESCRIPTION
OF DESIGN BASIS AXIAL POWER SHAPING ROD CONFIGURATION S FOR SOURCE TERM CALCULATIONS Axial Dimensions Relative to Bottom of Active Fuel1 Flux Weighting Factor Mass of cladding (kg Steel)
Mass of absorber (kg Inconel)
Start (in)
Finish (in)
Length (in) 0.0 63.0 63.0 1.0 5.29 24.89 63.0 66.8 3.8 0.2 0.32 1.51 66.8 76.25 9.45 0.1 0.79 3.73 1 This information shall be considered in the Radiation Transport Calculations, to correctly locate the source relative to the active region of the fuel assemblies to Holtec Letter 5014942 33 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 30 Project 5014 Holtec International 4.0 ANALYSIS PROCESS Below is an outline of the principal steps of the overall analysis process. For each step, it identifies what methodology is used and where that methodology is defined, and references locations in this topical report that provide additional information for the respective step. Note that not all methodologies are described in this report.
Step 1: Generation and Collection of input parameters and input data Define what is to be qualified o Cask systems o Fuel and anticipated BECTs o NFH and anticipated burnups and cooling times Compile all parameters that are required for the analyses and that are required to verify the applicability of the TR.
Identify and document any site-specific depletion parameters and other analytical aspects that may be different from the topical report, and where the TR allows such variations.
o If any parameters are outside of the applicability of the TR, then the method in the TR can not be used to qualify corresponding fuel assemblies.
Loading pattern(s), i.e. the identification of proposed or anticipated fuel characterization for the basket location or locations o Determination of the loading pattern(s) is a separate process not addressed here. It will reflect the fuel and NFH to be loaded, and potentially other aspects, such as thermal requirements or specific dose requirements other than those present in the context of this TR. The pattern could be developed using a manual process, or some specialized software.
All relevant information on the fuel assemblies to be qualified, including NFH if applicable o See Section 2.8 and Table 2.2, in combination with any more specific requirements from the corresponding FSAR/TS for the information that may be required.
Documentation: All this information needs to be either referenced appropriately in the qualification report, or directly documented in there.
Step 2: Source Term Calculations to Holtec Letter 5014942 34 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 31 Project 5014 Holtec International Note that there may be cases where only new loading pattern(s) are to be qualified for fuel where source term calculations were already performed. In that case, this step is skipped, and the previous calculations are referenced.
Select the design basis assembly from either Table 3.1 or Table 3.2.
For any NFH, develop the modeling in accordance with Sections 3.2, 3.4 or 3.5, as applicable Perform the ORIGAMI calculations with the TRITON libraries, for the fuel to be qualified.
o See Section 3.1 and Section 3.5 for a discussion on ORIGAMI calculations Extract neutron, gamma and 60Co source terms from the ORIGAMI outputs.
o Energy structures for gamma and neutron sources shall meet the requirements listed in Section 3.2 and Section 3.3.
o 60Co for fuel and non-fuel hardware is calculated Documentation: If source term calculations are only performed for a small set, e.g. for a specific site, the calculations may be documented as part of the qualification report. If calculations are performed supporting different loading pattern(s) possibly in different qualification reports, it is more appropriate to document the source term calculations and the results of those in a separate report that can then be referenced accordingly.
Step 3: Radiation Transport and Dose calculations It is a common practice to perform radiation transport calculations normalized to a fixed number of starting particles, and then just combine those with the source terms to establish dose rates. This significantly reduces the calculation effort. If only new content (i.e. new fuel and/or new loading patterns) are to be qualified for an already qualified system, no radiation transport calculations may be needed, but new dose rate values need to be calculated with the existing radiation transport analyses and the newly generated source terms. This will typically be the case if the system to be qualified is the same as that evaluated in the corresponding FSAR, and no modifications are required to the systems. In that case, no new radiation transport calculations are needed, and the existing calculations need to be referenced appropriately.
Select transfer and storage systems that the content is to be qualified for o Take the applicable radiation transport model that is consistent with the CoC revision that the fuel is to be qualified for. This may be from FSAR, including any applicable changes performed under 10 CFR 72.48 for that system. This may also be taken from an earlier qualification report for same systems, considering it is applicable to the CoC. to Holtec Letter 5014942 35 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 32 Project 5014 Holtec International o If need be, make changes to model. The extent of permissible changes is specific to the storage system, and would be defined and described in the corresponding FSAR/TS that references this TR. An example of how such permitted changes would be described in the FSAR is shown in Appendix C, Section C.3. A 72.48 evaluation need to be performed for these changes, to ensure they do not require NRC approval o Any other changes that are made to the radiation transport model, as permitted by this TR, need to be documented in the qualification report.
If changes to the model were made, confirm that the dose rate locations conform to the FSAR/TS requirements.
If new models had been generated, perform radiation transport analyses.
Select the set of burnup, enrichment and cooling times that need to be analyzed (follow guidance in Section 2.6)
Determine dose rate limits and corresponding dose locations from applicable FSAR/TS Combine the source terms for the selected BECTs with the results of the radiation transport calculation to result in dose rates at the locations. Typically, there will be a range of BECTs, so the maximum dose rate over all of those BECTs needs to be established.
To show that the content defined in Step 1 is qualified through the process in this topical report, dose rates shall be below the corresponding FSAR/TS limits.
Documentation: All new and unique calculations are to be documented in the qualification report.
Pre-existing calculations for source terms and/or radiation transport calculations should not be repeated, but referenced appropriately.
5.0 CONCLUSION
This Topical Report provides the framework and part of the methodology for qualifying fuel loading patterns, and when referenced in a Certificate of Compliance will provide the ability to more efficiently load spent fuel into dry storage. to Holtec Letter 5014942 36 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 33 Project 5014 Holtec International
6.0 REFERENCES
[1]
HI-STORM 100 FSAR, Holtec Report No. HI-2002444, Latest Non-Proprietary Revision [USNRC Docket 72-1014].
[2]
HI-STORM FW FSAR, Holtec Report No. HI-2114830, Latest Non-Proprietary Revision [USNRC Docket 72-1032].
[3]
A.G. Croff, M.A. Bjerke, G.W. Morrison, L.M. Petrie, Revised Uranium-Plutonium Cycle PWR and BWR Models for the ORIGEN Computer Code, ORNL/TM-6051, Oak Ridge National Laboratory, September 1978.
[4]
J.W. Roddy et al., Physical and Decay Characteristics of Commercial LWR Spent Fuel, ORNL/TM-9591/V1&R1, Oak Ridge National Laboratory, January 1996.
[5]
Characteristics of Spent Fuel, High Level Waste, and Other Radioactive Wastes Which May Require Long-Term Isolation, DOE/RW-0184, U.S. Department of Energy, December 1987.
[6]
Characteristics Database System LWR Assemblies Database, DOE/RW-0184-R1, U.S.
Department of Energy, July 1992.
[7]
B.T. Rearden and M.A. Jessee, Eds., SCALE Code System, ORNL/TM-2005/39, Version 6.2.1, Oak Ridge National Laboratory, Oak Ridge, Tennessee (2016).
[8]
B. Ade and B. Betzler, ORIGEN Reactor Libraries, Oak Ridge National Laboratories, April 8, 2016
[9]
Recommendations on Fuel Parameters for Standard Technical Specifications for Spent Fuel Storage Casks, NUREG/CR-6716, ORNL/TM-2000/385, Oak Ridge National Laboratory, Oak Ridge, Tennessee, March 2001.
[10]
Fuel Assembly Reference Information for SNF Radiation Source Term Calculations, ORNL/SPR-2021/2093, Oak Ridge National Laboratory, Oak Ridge, Tennessee, September 2021.
[11]
Axial Moderator Density Distributions, Control Blade Usage, and Axial Burnup Distributions for Extended BWR Burnup Credit, NUREG/CR-7224, ORNL/TM-2015/544, Oak Ridge National Laboratory, August 2016.
to Holtec Letter 5014942 37 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-1 Project 5014 Holtec International APPENDIX A EXAMPLES FOR FUEL QUALIFICATIONS A.1 Overview To illustrate the application of the methodology articulated in this TR, three example fuel qualifications are presented in this Appendix. The first example is for a general set of fuel qualifications, including several systems and various fuel types, and a rather generic distribution of fuel in a basket. The second example shows an evaluation for a site-specific fuel contents, for a single system, a single assembly type, and a simple single BECT. The third example is also an evaluation for site-specific content but for a very specific distribution of fuel in the basket. The main focus of these examples is to show how content may be specified for the different generic or site-specific approaches. For a more extensive outline of the corresponding activities and analyses in each case, see Section 4 of the main part of this report. Further see the two examples of a qualification report in Appendix D and Appendix E, based on Example 3 shown below.
A.2 Example 1, Generic Fuel Qualification The principal steps are as follows:
Step 1: Define inputs Canister: 32 Assembly Canister A, with regions defined in Figure A.1 Storage Cask: Storage Casks A, B, C Transfer Casks: Transfer Casks A, B, C Burnup, Enrichment and Cooling times (BECTs), see Table A.1. In this example, three different sets are defined.
For NFH limitations, see Table A.1a Fuel Types: W17x17, BW15x15 Dose Rate Limits and corresponding locations for all systems listed above, as defined in the corresponding FSAR/TS.
Step 2: Perform Source term analyses for all fuel types, and BECTs, consistent with the methodology in Section 3.0 of this TR. Select the BW 15x15 assembly as design basis assembly since it bounds the W17x17 in terms of fuel weight Step 3: Perform dose rate analyses, consistent with the methodology in this Topical Report, and utilizing the shielding models and corresponding parameters from the FSAR. to Holtec Letter 5014942 38 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-2 Project 5014 Holtec International Specify dose rate limits and corresponding locations for all systems listed above, as defined in the corresponding FSAR/TS.
Ensure that the qualification covers all systems, fuel assemblies and BECTs.
Ensure that all calculated dose rates meet the dose rate limits.
An example result table is shown in Table A.2 A.3 Example 2, Site-Specific Fuel Qualification, Typical Plant Operation The principal steps are as follows:
Step 1: Define inputs Canister: 32 Assembly Canister A, Uniform Loading Storage Cask: Storage Casks A Transfer Casks: Transfer Casks A, with site specific (possibly reduced) shielding thicknesses.
Burnup, Enrichment and Cooling times (BECTs):
Maximum Burnup 55 GWd/mtU Minimum Enrichment 4.0%
Minimum Cooling time 5 years Fuel Types: W17x17 No NFH are qualified Step 2: Perform Source term analyses for all fuel types, and BECTs, consistent with the methodology in Section 3.0 of this TR.
Step 3: Perform dose rate analyses, consistent with the methodology in this Topical Report, and utilizing the shielding models and corresponding parameters from the FSAR.
Specify dose rate limits and corresponding locations for all systems listed above, as defined in the corresponding FSAR/TS.
Ensure that all calculated dose rates meet the dose rate limits.
A.4 Example 3, Site-Specific Fuel Qualification, Decommissioning Operation The principal steps are as follows: to Holtec Letter 5014942 39 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-3 Project 5014 Holtec International Step 1: Define inputs Canister: 32 Assembly Canister A, with regions defined in Figure A.2 Storage Cask: Storage Casks A Transfer Casks: Transfer Casks A Burnup, Enrichment, and Cooling times (BECTs), see Table A.3 For NFH limitations, see Table A.3a Fuel Types: W17x17 Step 2: Perform Source term analyses for all fuel types, and BECTs, consistent with the methodology in Section 3.0 of this TR.
Step 3: Perform dose rate analyses, consistent with the methodology in this Topical Report, and utilizing the shielding models and corresponding parameters from the FSAR.
Specify dose rate limits and corresponding locations for all systems listed above, as defined in the corresponding FSAR/TS.
Ensure that the qualification covers all systems, fuel assemblies and BECTs.
Ensure that all calculated dose rates meet the dose rate limits.
An example result table is shown in Table A.4 to Holtec Letter 5014942 40 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-4 Project 5014 Holtec International Table A.1 BECTs for Example 1 Case 1
2 3
Region (See Figure A.1) 1 2
1 2
1 2
Maximum Burnup Minimum Enrichment Minimum Cooling Time (Years) 5000 1.1 1
1.5 1
1 1.25 1
10000 1.1 1.25 2.5 1.75 1.75 2
1.5 15000 1.6 1.75 3
2.25 2.25 2.5 1.75 20000 1.6 2
3.75 2.75 2.75 3.25 2.25 25000 2.4 2.5 4
3.25 3.25 3.5 2.75 30000 2.4 2.75 5
3.75 3.75 4
3 35000 2.9 3
7 4
4 4.5 3.5 40000 3.2 3.5 9
4.5 4.5 5
3.75 45000 3.6 3.75 11 5
5 6
4 50000 3.6 4
16 6
6 8
4 55000 3.9 4
21 8
8 11 5
60000 3.9 5
27 11 11 16 6
65000 4.5 6
31 13 13 20 7
70000 4.5 7
36 18 18 24 9
to Holtec Letter 5014942 41 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-5 Project 5014 Holtec International Table A.1a Burnup and Cooling Time Requirements for NFH Minimum Cooling Time (Years)
Maximum Burnup, MWd/mtU BPRAs TPDs, NSAs, CRAs, APSRs 3
30,000 180,000 10 50,000 630,000 to Holtec Letter 5014942 42 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-6 Project 5014 Holtec International Table A.1.1 Evaluated Burnup Sets for Example 1 Case 1
2 3
Region (See Figure A.1) 1 2
1 2
1 2
Calculation No.
Burnup (for corresponding enrichment and cooling times see Table A.1) 1 15000 25000 10000 10000 60000 25000 2
55000 10000 65000 30000 70000 35000 3
50000 30000 35000 60000 65000 15000 4
35000 20000 20000 5000 20000 55000 5
20000 60000 25000 40000 25000 50000 6
70000 15000 5000 15000 40000 5000 7
60000 50000 30000 45000 50000 20000 8
5000 45000 15000 55000 15000 40000 9
40000 55000 50000 70000 10000 30000 10 30000 65000 55000 25000 35000 45000 11 10000 35000 70000 20000 5000 10000 12 25000 40000 60000 35000 55000 60000 13 65000 5000 40000 50000 45000 70000 14 45000 70000 45000 65000 30000 65000 to Holtec Letter 5014942 43 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-7 Project 5014 Holtec International Table A.2 Dose Comparison for Example 1 Dose Location (see Reference [1],
Figure 5.1.13)
Maximum Calculated Dose Rate, mrem/hr Dose Rate Limit for fuel qualification, mrem/hr Storage Cask B (bounds A and C) 1 100 200 2
200 300 3
200 300 4
30 100 Transfer Cask C (bounds A and B) 1 500 800 2
600 900 3
500 600 4
50 100 Note that these are arbitrary values for illustrative purposes, not the results of any specific calculation.
to Holtec Letter 5014942 44 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-8 Project 5014 Holtec International Table A.3 BECTs for Example 3 Region (See Figure A.2) 1 2
3 4
5 Maximum Burnup Minimum Enrichment Minimum Cooling Time (Years) 5000 1.1 2.25 1.5 1.25 1
1 10000 1.1 3.5 2.5 2
1.5 1
15000 1.6 4
3 2.5 2
1 20000 1.6 6
3.75 3
2.5 1
25000 2.4 9
4 3.5 2.75 1.25 30000 2.4 17 5
4 3.25 1.5 35000 2.9 22 7
4.5 3.5 1.75 40000 3.2 30 9
5 3.75 1.75 45000 3.6 43 11 6
4 2
50000 3.6 51 16 8
5 2.25 55000 3.9 57 21 10 6
2.25 60000 3.9 n/a 27 14 7
2.5 65000 4.5 n/a 31 17 9
2.75 70000 4.5 n/a 36 22 11 3
to Holtec Letter 5014942 45 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-9 Project 5014 Holtec International Table A.3a Burnup and Cooling Time Requirements for NFH Minimum Cooling Time (Years)
Maximum Burnup, MWd/mtU BPRAs TPDs, NSAs, CRAs, APSRs 3
30,000 180,000 10 50,000 630,000 to Holtec Letter 5014942 46 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-10 Project 5014 Holtec International Table A.3.1 Evaluated Burnup Sets for Example 3 Region (See Figure A.2) 1 2
3 4
5 Calculation No.
Burnup (for corresponding enrichment and cooling times see Table A.3) 1 15000 25000 10000 10000 60000 2
55000 10000 65000 30000 70000 3
50000 30000 35000 60000 65000 4
35000 20000 20000 5000 20000 5
20000 60000 25000 40000 25000 6
55000 15000 5000 15000 40000 7
55000 50000 30000 45000 50000 8
5000 45000 15000 55000 15000 9
40000 55000 50000 70000 10000 10 30000 65000 55000 25000 35000 11 10000 35000 70000 20000 5000 12 25000 40000 60000 35000 55000 13 55000 5000 40000 50000 45000 14 45000 70000 45000 65000 30000 to Holtec Letter 5014942 47 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-11 Project 5014 Holtec International Table A.4 Dose Comparison for Example 3 Dose Location (see Reference [1],
Figure 5.1.13)
Maximum Calculated Dose Rate, mrem/hr Dose Rate Limit for fuel qualification, mrem/hr Storage Cask 1
100 200 2
200 300 3
200 300 4
30 100 Transfer Cask 1
500 800 2
600 900 3
500 600 4
50 100 Note that these are arbitrary values for illustrative purposes, not the results of any specific calculation.
to Holtec Letter 5014942 48 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-12 Project 5014 Holtec International NFH is permitted in the following regions:
BPRAs, TPDs Region 1 and 2 CRAs Region 1 NSAs 1 NSA per cask, in Region 1 Figure A.1 32 Assembly Basket Layout with the Region Number identified in each Cell for Example 1 2
2 2
2 2
2 1
1 2
2 2
1 1
1 1
2 2
1 1
1 1
2 2
2 1
1 2
2 2
2 2
2 to Holtec Letter 5014942 49 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 A-13 Project 5014 Holtec International NFH is permitted in the following regions:
BPRAs, TPDs All regions CRAs Regions 1 and 2 NSAs 1 NSA per cask, in Region 1 Figure A.2 32 Assembly Basket Layout with the Region Number identified in each Cell for Example 3 5
3 3
5 5
4 2
2 4
5 3
2 1
1 2
3 3
2 1
1 2
3 5
4 2
2 4
5 5
3 3
5 to Holtec Letter 5014942 50 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 B-1 Project 5014 Holtec International APPENDIX B REQUIREMENTS FOR FSAR/TS CONTENT The designs and calculational models for the radiation transport evaluations are documented in the corresponding FSARs, together with any applicable acceptance criteria and specification of the area of applications. Requirements for the information that needs to be provided in the FSAR are summarized below.
B.1 Calculational Models
- 1) The calculational models shall represent the designs with sufficient and reasonable level of detail.
Modern Monte Carlo codes for radiation transport evaluations, such as MCNP, are capable to represent a geometry without any significant simplifications that may affect the quality of the results.
a) Overall dimensions, and extension and properties of major shielding materials can be modeled realistically or in a bounding fashion. In this context, bounding fashion would be modeling with a lower bound thickness or density.
b) However, for local details, specifically inside of the system, modeling of intricate details is not necessary, as long as the overall shielding effect is reasonably represented.
- 2) Streaming paths need special attention, and a higher level of detail may be needed there to assure the streaming is considered.
- 3) Design Basis Fuel assemblies are acceptable to be modeled with several axial sections of different materials, one of them being the active region, with a homogenized material mixture in each section representing the materials in that section.
- 4) The statistical uncertainties of dose rates to be compared to the acceptance criteria should be reasonable.
As general guideline, overall uncertainty should be no more than 5%, with individual contributions (i.e., gamma, 60Co, neutrons, n-gamma) no more than 10% each, consistent with Reference [1].
- 5) The masses that are considered in the model for self-shielding of fuel shall be consistent with (i.e., the same or lower than) the masses utilized in the source term calculations.
- 6) The calculations shall consider the axial burnup distribution of the fuel assemblies.
- 7) Fuel conditions other than undamaged fuel may need additional considerations with respect to their spatial distribution of the material and the applied source term.
- 8) The text needs to identify the aspects of the design that can be changed under 10CFR72.48 B.2 Acceptance Criteria
- 1) Acceptance criteria are dose rates in selected locations around the transfer or storage casks.
a) Number and location of the dose points should be selected to be representative of the contents of the cask. For example, for a vertical above-ground system, dose rate locations on side of the cask and on the top of the lid may be needed. The locations on the side will be more representative for to Holtec Letter 5014942 51 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 B-2 Project 5014 Holtec International the fuel in the periphery cell locations of the basket, while the dose rate on the top lid will be more representative of the contribution from the assemblies in the center of the basket.
b) Dose rates on the surface of the casks at local discontinuities such as inlets and outlets are less suitable. If the areas of these dose rates are small, they would not represent a significant contribution to any occupational or site boundary dose, hence the level of the dose rate at the location is of little relevance. Controlling such locations through individual limits could therefore unnecessarily restrict the contents, without any related safety benefits.
c) Removed.
For further guidance, see Section 2.6 of the main part of this report.
B.3 Area of Applicability
- 1) For fuel, the area of applicability shall be specified in the form of the list of assemblies and assembly types that can be loaded, and maximum burnup, minimum cooling time, and any enrichment limits if applicable.
- 2) For the casks, the area of applicability may include limits of changes permitted to the systems, such as changes in dimensions, materials, or material densities.
B.4 Representative Contents
- 1) To demonstrate the overall performance details of the systems, doses and dose rates are presented in the FSAR, including dose rates in the vicinity of the cask at locations other than those specified as acceptance criteria, occupational dose rates during loading and unloading of the casks, and dose rates for selected cask arrays at selected distances from the array to demonstrate the system meets the requirements of 72.236(d), 72.104, and for calculations to demonstrate compliance accident dose rates under 72.106.
- 2) For these analyses, one or more representative contents shall be selected, such that the dose rates used as acceptance criteria are met at the respective locations. For any given location, the total dose rates are either dominated by gamma source terms (fuel gamma and 60Co contribution), or by neutron source terms (neutron and n-gamma). Hence one of two source distributions would result in a representative and conservative dose rates:
a) Low cooling time, and corresponding (low) burnup so the dose acceptance is reached. This will maximize dose in locations where gamma contribution dominates; or b) High burnup, and corresponding (longer) cooling time so the dose acceptance is reached. This will maximize dose in locations where neutron contribution dominates.
- 3) For each dose rate analysis with representative content, both conditions (items a) and b) stated in previous bullet) shall be analyzed, and for each dose location the higher value shall be reported or utilized.
- 4) For accident conditions, both source distributions shall be evaluated to ensure that the maximum accident does rate is identified. For example, for a transfer cask with water on the outside for neutron to Holtec Letter 5014942 52 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 B-3 Project 5014 Holtec International shielding, the accident could be the loss of this water. Under this accident condition, the source distribution that maximizes the neutron doses may be more bounding, even if the contribution that maximizes gamma dose is more bounding under normal conditions for the same cask. to Holtec Letter 5014942 53 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 C-1 Project 5014 Holtec International APPENDIX C EXAMPLE OF FSAR SECTION This appendix contains an example for a Section added to an FSAR to utilize the method and framework outlined in this TR. Further to this addition, the TR shall be referenced in the corresponding CoC/TS. The example is based on the FSAR for the HI-STORM FW, where the shielding safety analyses are in Chapter 5 and Chapter 11. However, for consistency with the nomenclature of this appendix, section and subsection numbers start with C.
C.1 Radiological Qualification of Content This subsection discusses the two ways the content of the cask, i.e., the fuel assemblies, can be qualified.
The qualification discussed here includes burnup, enrichment and cooling time (BECTs) of the fuel assemblies, and certain other parameters. Decay heat requirements are not part of this subsection, they are discussed in Chapter 4, and are independent of the discussions presented here. Specifically, the qualification process specified here does not imply that fuel meets any decay heat requirements, and vice versa.
Fuel needs to be clearly qualified so regulatory requirements in 72.236(a) and (d) can be met. That means that for a given fuel assembly proposed to be loaded into a certain basket cell, a clear decision can be made if loading that fuel into that cell is permitted (qualified) or not. Since content is often defined as a pattern for an entire basket loaded with fuel, the qualification may depend on the pattern, i.e., on the specification of other assemblies in the basket, not just on the parameters of the assembly proposed for that cell.
Two alternative approaches are specified in this FSAR to perform this qualification:
- 1. BECTs are directly specified in the approved content section of the technical specifications. They can be specified as tables or as equations, linking providing a relationship between the BECTs, and these can vary between loading patterns. These are based on and supported by the analyses presented in this chapter, including dose rates presented in Section 5.1 around the casks, and for the possible locations at the controlled area boundary.
- 2. A method defined in a topical report is used to define and qualify the content for a given cask. The results of the process (i.e. the tables or equations) are documented in a separate qualification report.
But the process relies on technical details documented in this FSAR.
The remainder of this subsection addresses all technical details that are needed and important for the second approach stated above. It addresses the modeling, acceptance criteria, and area of applicability. Some of the details and limits are included in the technical specification, either by repeating values in there, or by including parts of this subsection by reference into the technical specification.
C.2 Acceptance Criteria The acceptance criteria are dose rates, and dose rate limits are defined in this subsection and specified in the TS. Limits are specified for both the HI-TRAC transfer cask and the HI-STORM overpack. Dose rates around the HI-TRAC are typically higher, and hence more important from an ALARA perspective during cask loading operations, while dose rates around the HI-STORM are more important for storage operations to Holtec Letter 5014942 54 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 C-2 Project 5014 Holtec International and site (e.g. owner controlled area) boundary. For certain design combinations, dose rates from the HI-TRAC may be more limiting, whereas for others dose rates form the HI-STORM may be more limiting.
For that reason, dose rate limits for both systems are defined, and need to be independently confirmed for any given content.
For each system, dose rate limits are defined separately for the side and the top of the cask since top and side have a different relevance from an operational perspective.
Dose rates can exhibit significant variations across a given surface, due to design details of the cask and the characteristics of the content such as axial source distribution and loading pattern. Consequently, a sufficient number of dose locations have to be defined to capture the highest dose rate.
Additionally, a minimum area is specified for the maximum dose rate. This maximum dose rate is determined as an average over an area of no more than about TBD ft2. Larger areas would possibly mask the local effect of fuel content, such as the effect of fuel distribution throughout the basket, whereas smaller areas would possibly shift the importance to local effects of the cask design rather effects of the content.
Note that this selection is based on the need to determine a clear and unambiguous acceptance criteria for the content. If there are local discontinuities in the cask design that result in higher local does rates for smaller areas, these need to be considered by the RP personnel and taken into account for loading and other operations.
C.2.1 HI-TRAC The different areas of the HI-TRAC are the side and the top of the cask.
The limits for these areas are selected as follows:
Side o Maximum TBD rem/hr Top o Maximum TBD rem/hr The dose rate limits were selected to be comparable to, but slightly lower than those dose rates calculated before and documented in Subsection 5.1.
C.2.2 HI-STORM The different areas of the HI-STORM are the side and the top of the cask.
The limits for these areas are selected as follows:
Side o Maximum TBD mrem/hr Top o Maximum TBD mrem/hr to Holtec Letter 5014942 55 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 C-3 Project 5014 Holtec International As for the HI-TRAC, dose rates are selected based on, but slight lower then shown in Subsection 5.1.
Note that for the HI-STORM, this is only part of the necessary dose considerations, and additional dose limits exist based on the need to show compliance with 72.104. These are often more restrictive than the general limits from the qualified content defined here, but are specified for the entire ISFSI and compliance is demonstrated on a site-specific basis.
C.3 Calculational Models The calculations to show compliance with the above dose rate limits shall be those described in Section 5.3 of this chapter, but the following changes or adjustments are permitted:
Thicknesses of the main materials relevant for shielding, i.e. steel, concrete, lead and water, can be changed, i.e., increased or reduced.
Concrete density can be increased or reduced.
Overall height of the casks can be changed, i.e., increased or reduced.
Modifications to inlet or outlet air paths.
The following changes are not permitted:
Introduction of shielding materials not currently used.
Reduction of the level of detail in modeling specific design details, such as homogenization of materials beyond what is currently applied.
Note that any change or adjustment has to be validated against 10 CFR 72.48 and all other safety requirements, not just shielding.
For any changes that are made under 10 CFR 72.48, it must also be verified that dose locations are still meet with the requirements stated in Section 2.6 of the topical report [C.1], or those location need to be revised accordingly Overall, the models described in Section 5.3, and required to be used for the shielding calculations to qualify fuel, meet the guidance in Appendix B of the topical report [C.1]. Specifically, They model the geometry with sufficient detail, i.e., without any significant simplifications of the geometry.
They use MCNP, a state-of-the-art Monte-Carlo program Inputs and outputs for the airflow path in the HI-STORM, which are main concerns from a streaming perspective, are modeled accurately.
Fuel assemblies are modeled with separate axial sections, one of them for the active region, each using a homogenized material.
Uncertainties of the results are generally of the order of 5% or less.
Fuel masses for self-shielding are less or equal to those used in the source term analyses.
The axial burnup profile is considered in the source term definition. to Holtec Letter 5014942 56 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 C-4 Project 5014 Holtec International Area of Applicability Qualification is limited to the fuel assemblies that are explicitly listed in the TS, and the following burnup, enrichment and cooling time limits:
Maximum assembly average burnup o PWR assemblies - 68.2 GWd/mtU o BWR assemblies - 65 GWd/mtU Minimum cooling time o TBD years Minimum enrichment o TBD From a cask perspective, the qualification is limited to the HI-TRAC and HI-STORM in this FSAR, with modification permitted as discussed before in this subsection.
C.4 Other doses and dose rates In this subsection, doses and dose rates for other dose location and other conditions (i.e., not for dose rate limits stated in the previous subsection) are evaluated and presented, that are consistent with the dose limits stated above. For this, representative content is developed for the casks, and used in the dose analyses. It is necessary to develop this representative content here, since the content that would be qualified based on the dose rate limited is not known yet. To cover the different conditions, this representative content is developed separately for the HI-TRAC and HI-STORM, and also separately for more gamma and more neutron dominated content. The development of the content follows the steps outlined below:
Gamma or Neutron o To represent more gamma dominated content, the cooling time is set to the minimum (TBD years in all cases), and then the burnups are adjusted until the dose rate limits are approximately met.
o To represent more neutron dominated content, the burnup is set to the maximum, and then the cooling times are adjusted until the dose rate limits are approximately met.
approximately met is understood that the limits are in general slightly exceeded. This way, the derived other doses and dose rates would be expected to be upper bound values that would not be exceeded when the fuel is loaded to the qualified limit.
Side and top of casks o The side dose rates are more determined by the assemblies on the periphery of the basket, whereas the top dose rates are generally more determined by the assemblies in the center of the basket. Hence the assemblies on the periphery of the basket may be selected with different burnup/cooling time values than those in the center of the basket, to match the respective limits.
Surface maximum to Holtec Letter 5014942 57 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 C-5 Project 5014 Holtec International o Even within the cells on the periphery and the cells in the center of the basket, variations in burnups and cooling times may be selected to match the maximum dose rate.
Cask version o For normal conditions, nominal cask design are used for the evaluations presented here, specifically the HI-TRAC with TBD inches of lead, and the HI-STORM FW with a concrete density of TBD pcf in the wall.
o These choices are not critical for the evaluations presented here, since it is to be expected that for the same surface dose rates, the other dose rates presented here would also be similar, regardless of the specific characteristics of the cask used in the evaluations.
For the accident condition of the loss of water from the HI-TRAC outer water shield, a model with minimum lead thickness is evaluated.
o This represents a bounding condition for the accident dose rate at 100 m distance. No further site-specific accident evaluations are therefore necessary.
The representative content identified based on the above is as follows:
HI-TRAC o Gamma dominated Outer assemblies TBD GWd/mtU, TBD years Inner assemblies TBD GWd/mtU, TBD years o Neutron dominated Outer assemblies TBD GWd/mtU, TBD years Inner assemblies TBD GWd/mtU, TBD years HI-STORM o Gamma dominated Outer assemblies TBD GWd/mtU, TBD years Inner assemblies TBD GWd/mtU, TBD years o Neutron dominated Outer assemblies TBD GWd/mtU, TBD years Inner assemblies TBD GWd/mtU, TBD years This content is then used to evaluate doses and dose rates at the following locations / under the following conditions Normal conditions o HI-TRAC and HI-STORM, surface and 1 m distance, at the same locations that were evaluated in Section 5.1. This is not to demonstrate compliance with any regulatory requirement, but to give an indication of the maximum dose rates in those locations.
o Occupational dose rates, equivalent to those presented in Chapter 11.
o HI-STORM, annual dose for various cask arrays at selected distances, to show compliance with 72.236(d) to Holtec Letter 5014942 58 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 C-6 Project 5014 Holtec International Accident condition o HI-TRAC with loss of water from the water jacket, at 100 m from the cask. This is to generally show compliance with 72.106.
For each dose location, results from the more gamma dominated and the more neutron dominated representative content are calculated, and the maximum values are presented in the tables at the end of this subsection.
C.5 Summary The information in this subsection is to be used, in combination with the information presented in the TR
[C.1] to qualify content (fuel assemblies) for the casks in the FSAR. The qualification is documented in one or more qualification reports, as also outlined in the TR [C.1].
For details on which information in this subsection can or cannot be modified under 72.48 see Section C.3.
C.6 References
[C.1]
HI-2210161 Table C.1 Normal, HI-TRAC (equivalent to FSAR Table 5.1.1)
Table C.2 Normal, HI-STORM (equivalent to FSAR Table 5.1.5)
Table C.3 occupational (equivalent to FSAR Table 11.3.2, but summary only)
Table C.4 HI-STORM arrays (equivalent to Table 5.1.3)
Table C.5 HI-TRAC, Accident (equivalent to Table 5.1.4) to Holtec Letter 5014942 59 of 89
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Report HI-2210161 D-1 Project 5014 Holtec International APPENDIX D EXAMPLE OF FUEL QUALIFICATION REPORT The following example report outlines the structure and required content of the qualification report that should be followed. Any deviation from this structure and/or content requires justification that the report satisfies the original intent of documenting the qualification process.
Since this is an example for a separate report, it has its separate Table of Content, and page and section numbers. Information that would be site specific or depend on the specific implementation of this topical report in the corresponding FSAR and CoC are listed as TBD.
to Holtec Letter 5014942 60 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: i Table of Contents
- 1.
Purpose................................................................................................................................... 1
- 2.
General Methodology........................................................................................................... 1
- 3.
Acceptance Criteria.............................................................................................................. 2
- 4.
Assumptions........................................................................................................................... 2
- 5.
Input Data.............................................................................................................................. 3
- 6.
Computer Codes.................................................................................................................... 3
- 7.
Analysis and Results............................................................................................................. 3
- 8.
Computer Files...................................................................................................................... 4
- 9.
Summary................................................................................................................................ 5
- 10. References.............................................................................................................................. 5 Appendix A:
HI-TRAC 100 and HI-STORM 100 Models and Tallies (total of 5 pages) A-1 to Holtec Letter 5014942 61 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 1
- 1. Purpose The purpose of this report is to document the qualification of fuel for loading into the HI-STORM 100 [5]. Qualification is performed based on the process defined in the Shielding MOE Topical Report [6], together with the Section 5.TBD in [5] and the requirements outlined in Section TBD of the HI-STORM 100 CoC [1].
The qualification is performed for fuel defined in this report, and for loading into the MPC-32 and for the HI-TRAC 100 and the HI-STORM 100, with the specific fuel characteristics defined in this report. Only fuel that meets all explicit requirements outlined in this report can be loaded under this qualification in this basket and in these casks.
The purpose of this qualification is compliance with 10 CFR 72.236(a), and hence with 10 CFR 72.236 (d) as discussed in [5].
Note that compliance with 10 CFR 72.104 and 10 CFR 72.106 is not part of the scope of this document. This is demonstrated in other reports.
For the qualification, dose rates calculations with burnup, enrichment and cooling times bounding all fuel to be qualified are performed for these conditions, for the locations and conditions specified in Section 5.TBD in [5], and it is shown that the dose rates are below the applicable limits defined in Section TBD of the HI-STORM 100 CoC [1]
- 2. General Methodology The HI-STORM 100 model is taken from reference [5], with the following site-specific parameter:
TBD The HI-TRAC 100 model is taken from reference [5], with the following site-specific parameter:
TBD Qualification is only for loading fuel into casks that meet these conditions.
The calculations are performed for the 17x17 design basis fuel specified in Table 3.1 of [6].
The radiation analysis performed in this report can be separated into two distinct parts. The first is the generation of the radiation source terms to represent the spent nuclear fuel at the appropriate burnup and cooling time. The second part is the radiation transport simulation to calculate the dose rates near and far from a cask.
to Holtec Letter 5014942 62 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 2 The neutron and gamma source terms, and the decay heat values, are calculated with the TRITON / ORIGAMI module of the SCALE 6.2.1 code package [7]. This is an improved method compared to the SAS2H [2] / ORIGEN-S [3] from SCALE 5.1, using predefined libraries for a large number of standard fuel assemblies, based on updated data sets, using a 252-energy group structure. Use of this code is consistent with the requirement in [6].
The TRITON / ORIGAMI input and output files are presented in reference [10]. Calculated gamma, neutron and hardware source terms are also presented in reference [10].
The radiation transport simulation is performed with MCNP5 [4] from Los Alamos National Laboratory. This is a state of the art Monte Carlo code that offers coupled neutron-gamma transport using continuous energy cross sections in a full three-dimensional geometry. The HI-STORM 100 and HI-TRAC 100 are modeled in full three-dimensional geometries in MCNP5.
- 3. Acceptance Criteria The HI-STORM 100 Certificate of Compliance (CoC) [1] describes dose rate requirements for fuel qualification in Section 5.TBD of Appendix A. Subsection 5.TBD states:
Based on the analysis performed pursuant to Section 5.TBD, the licensee shall demonstrate that for the fuel to be loaded, dose rate for the HI-TRAC TRANSFER CASK and the HI-STORM OVERPACK shall be below the following value:
- a. The top of the TRANSFER CASK TBD maximum
- b. The side of the TRANSFER CASK TBD maximum
- c. The top of the OVERPACK TBD maximum
- d. The side of the OVERPACK TBD maximum
- 4. Assumptions The following assumptions are used:
- 1. The HI-TRAC 100 transfer cask is calculated with the water jacket full of water, a dry annulus between the MPC and HI-TRAC and an MPC empty of water.
- 2. The HI-TRAC transfer cask is assumed to be surrounded by air on all sides.
- 3. The enrichment of the fresh fuel assembly modeled in MCNP for this report is 3.4 wt.%
235U. This is a conservative assumption since the actual spent fuel in a storage cask has fewer amounts of fissile isotopes as compared to using a 235U enrichment of 3.4 wt.%.
Using a higher 235U concentration in the active fuel region in MCNP will result in higher secondary neutron production from subcritical multiplication and fast fission in the fuel and also higher gamma doses from n, gamma reactions within the shielding materials.
Both of these quantities are calculated in MCNP and are not part of the source term calculations. Also, fission products in the burned fuel, which decrease the neutron multiplication factor, are conservatively neglected. This assumed enrichment of 3.4 wt.%
235U in the MCNP models is consistent with MCNP models used in References [8].
to Holtec Letter 5014942 63 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 3 Other assumptions are stated in the text as necessary. Since this report uses MCNP models from the HI-STORM 100 analyses, additional assumptions and discussion can be found in references
[5] and [8].
- 5. Input Data The source terms are from reference [10]. The MCNP input data, material compositions, cask geometry are from references [5] and [8].
The loading pattern for this qualification analysis is shown in Table 1, with the respective regions shown in Figure 1.
- 6. Computer Codes Computer codes to perform source term calculations are TRITON and ORIGAMI from the SCALE 6.2.1 package [7].
Dose rate calculations are performed with MCNP5 [4].
- 7. Analysis and Results This analysis principally uses the same cask models as used in reference [5] for site boundary calculations.
This section of the report describes the calculations that are performed to determine the dose rates on the surface of the HI-TRAC 100 and HI-STORM 100. The basic development of the MCNP models is provided in references [5] and [8]. This information is appropriately referenced as needed.
The source terms methodology is described in reference [6]. Source terms calculated using this methodology are documented in reference [10].
Two subsets of burnup, enrichment and cooling time combinations, each with 14 cases, were evaluated. The sets are shown in Table 1 and Table 1a. Additionally, a bounding condition for NFH is determined based on Table 1b, and the contribution is added to the source from the appropriate region for the NFH as shown in Figure 1.
All results presented in this calculation package were calculated using the ANSI/ANS-6.1.1-1977 flux to dose conversion factors [9].
Appendix A describes the HI-TRAC 100 and HI-STORM 100 Tallies. This appendix summarizes the tally surfaces and cells, and segments for the dose calculations performed for the HI-TRAC 100 and the HI-STORM 100.
to Holtec Letter 5014942 64 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 4
- 8. Computer Files All computer runs listed here are made on Computer Systems at Holtecs office. All files are stored on the Holtec computer server.
The following is a list of the MCNP runs that are used.
HI-STORM 100 Filenames MCNP Run Source TBD TBD TBD TBD TBD TBD HI-TRAC 100 Filenames (water jacket full of water, a dry annulus between the MPC and HI-TRAC, and an MPC empty of water)
MCNP Run Source TBD TBD TBD TBD TBD TBD to Holtec Letter 5014942 65 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 5
- 9. Summary The qualification of content (fuel assembly burnup, enrichment and cooling times) is presented in this report.
Tables 2 and 3 present the surface dose rates for the HI-TRAC 100 and the HI-STORM 100 for the content to be qualified that is listed in Table 1. All dose rates are below the respective limits, hence the fuel as specified in Table 1 is qualified through this report.
- 10. References
[1]
HI-STORM 100 Certificate of Compliance 1014, Amendment 8R1.
[2]
I.C. Gauld, O.W. Hermann, SAS2: A Coupled One-Dimensional Depletion and Shielding Analysis Module, ORNL/TM-2005/39, Version 5.1, Vol. I, Book 3, Sect. S2, Oak Ridge National Laboratory, November 2006.
[3]
I.C. Gauld, O.W. Hermann, R.M. Westfall, ORIGEN-S: SCALE System Module to Calculate Fuel Depletion, Actinide Transmutation, Fission Product Buildup and Decay, and Associated Radiation Source Terms, ORNL/TM-2005/39, Version 5.1, Vol. II, Book1, Sect. F7, Oak Ridge National Laboratory, November 2006.
[4]
LA-UR-03-1987, MCNP A General Monte Carlo N-Particle Transport Code, Version 5, April 24, 2003 (Revised 2/1/08).
[5]
Final Safety Analysis Report for the HI-STORM 100 Cask System, HI-2002444 Revision 18, Holtec International (US NRC Docket No. 72-1014).
[6]
Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems, HI-2210161, Holtec International
[7]
B. T. Rearden and M.A. Jessee, Eds., SCALE Code System, ORNL/TM-2005/39, Version 6.2.1, Oak Ridge National Laboratory, Oak Ridge, Tennessee (2018). Available from Radiation Safety Information Computational Center as CCC-834.
[8]
HI-STORM 100 System Additional Shielding Calculations, HI-2012702 Revision 15, Holtec International.
[9]
American National Standard Neutron and Gamma-Ray Flux-to-Dose Rate Factors, ANSI/ANS-6.1.1-1977.
[10] Source Terms and Loading Patterns Using Scale 6.2, HI-2167524 Revision 5, Holtec International. to Holtec Letter 5014942 66 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 6 Table 1 Qualified Burnup, Enrichment and Cooling Time Combinations Region (See Figure 1) 1 2
3 4
5 Maximum Burnup Minimum Enrichment Minimum Cooling Time (Years) 5000 1.1 2.25 1.5 1.25 1
1 10000 1.1 3.5 2.5 2
1.5 1
15000 1.6 4
3 2.5 2
1 20000 1.6 6
3.75 3
2.5 1
25000 2.4 9
4 3.5 2.75 1.25 30000 2.4 17 5
4 3.25 1.5 35000 2.9 22 7
4.5 3.5 1.75 40000 3.2 30 9
5 3.75 1.75 45000 3.6 43 11 6
4 2
50000 3.6 51 16 8
5 2.25 55000 3.9 57 21 10 6
2.25 60000 3.9 n/a 27 14 7
2.5 65000 4.5 n/a 31 17 9
2.75 70000 4.5 n/a 36 22 11 3
to Holtec Letter 5014942 67 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 7 Table 1a Evaluated Burnup Sets Region (See Figure 1) 1 2
3 4
5 Calculation No.
Burnup (for corresponding enrichment and cooling times see Table 1) 1 15000 25000 10000 10000 60000 2
55000 10000 65000 30000 70000 3
50000 30000 35000 60000 65000 4
35000 20000 20000 5000 20000 5
20000 60000 25000 40000 25000 6
55000 15000 5000 15000 40000 7
55000 50000 30000 45000 50000 8
5000 45000 15000 55000 15000 9
40000 55000 50000 70000 10000 10 30000 65000 55000 25000 35000 11 10000 35000 70000 20000 5000 12 25000 40000 60000 35000 55000 13 55000 5000 40000 50000 45000 14 45000 70000 45000 65000 30000 to Holtec Letter 5014942 68 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 8 Table 1b Burnup and Cooling Time Requirements for NFH Minimum Cooling Time (Years)
Maximum Burnup, MWd/mtU BPRAs TPDs, NSAs, CRAs, APSRs 3
30,000 180,000 10 50,000 630,000 to Holtec Letter 5014942 69 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 9 Table 2 Surface Dose Rates for the HI-TRAC 100 for Fuel Qualification Location Calculated Dose Rate (mrem/hr)
Dose Rate Limit (mrem/hr)
Dose Rate Limit Met Side, Maximum TBD TBD YES Top, Maximum TBD TBD YES Table 3 Surface Dose Rates for the HI-STORM 100 for Fuel Qualification Location Calculated Dose Rate (mrem/hr)
Dose Rate Limit (mrem/hr)
Dose Rate Limit Met Side, Maximum TBD TBD YES Top, Maximum TBD TBD YES to Holtec Letter 5014942 70 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: 10 5
3 3
5 5
4 2
2 4
5 3
2 1
1 2
3 3
2 1
1 2
3 5
4 2
2 4
5 5
3 3
5 NFH is permitted in the following regions:
BPRAs, TPDs All regions CRAs Regions 1 and 2 NSAs 1 NSA per cask, in Region 1 Figure 1: 32 Assembly Basket Layout with the Region Number identified in each Cell to Holtec Letter 5014942 71 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: A-1 Appendix A: HI-TRAC 100 and HI-STORM 100 Models and Tallies (total of 5 pages)
This appendix summarizes the tally surfaces and cells, and segments for the dose calculations performed for the HI-TRAC 100 and the HI-STORM 100.
HI-TRAC 100 Discussion:
The MCNP surfaces and cells that are used for tallying in the HI-TRAC 100 models are provided below.
Surface/Cell Description 4100-4108 Cells - Segmented axially along outer side surface.
6000 Cell - Top of HI-TRAC 100 Lid, segmented in concentric rings.
The surfaces are segmented in axial, circumferential and radial direction so individual tallied areas are about the size of TBD ft2.
Figures A1 through A2 provide figures which will help in understanding the modeling.
HI-STORM 100 Discussion:
The MCNP surfaces and cells that are used for tallying in the HI-STORM 100 models are provided below.
Surface/Cell Description 4100-4108 Cell - Outer edge of overpack 6000 Surface - Top of HI-STORM lid The surfaces are segmented in axial, circumferential and radial direction so individual tallied areas are about the size of TBD ft2.
Figures A3 through A4 provide pictures of the MCNP model of the HI-STORM 100 overpack that will aid in understanding the modeling.
to Holtec Letter 5014942 72 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: A-2 TBD Figure A1: MCNP model for HI-TRAC 100. to Holtec Letter 5014942 73 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: A-3 TBD Figure A2: A cross sectional view of the HI-TRAC 100 model.
to Holtec Letter 5014942 74 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: A-4 TBD Figure A3: A cross sectional view of the side of the HI-STORM 100 overpack model.
to Holtec Letter 5014942 75 of 89
Appendix D to Report HI-2210161 Project EXAMPLE Report: HI-EXAMPLE Revision 0 Page: A-5 TBD Figure A4: A view of the model used for the HI-STORM 100 overpack.
to Holtec Letter 5014942 76 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 1 of 9 Revision 0 This appendix presents an alternative way of documenting the qualification to that in Appendix D. This form consists of a summary table providing all the relevant information, with appendices for information that would not fit into the table. But unlike the example in Appendix D, the calculational details are not included and other calculation reports are referenced instead. A blank template with additional guidance is included as Appendix F to the report.
Parameter Requirements outlined in Topical Report Qualified Value(s) or Parameter(s)
Justification or Reference Storage Cask Cask Systems Specification of the casks systems that the fuel is qualified for Storage CASK A Transfer Cask A 32 assembly basket
[1], [2]
Shielding Design Changes and Site Specific Parameters Shielding design can be changed via 72.48, some designs have variable thickness transfer casks, however changes and/or site-specific parameters must be included in the shielding analyses used as a part of the FSAR method for dose rate calculations The following design parameters for the cask system were modified for the qualification documented here:
- Storage Cask: TBD
- Transfer Cask: TBD
[5]
Allowable content definitions Fuel assemblies and characteristics that can be loaded Allowable fuel assemblies are in Table 2.2 of the topical; FSAR will have more specific allowable fuel assembly characteristics; different masses of assemblies may be analyzed as long as the same mass is used in the source term and dose rate analyses All PWR fuel assemblies specified in [1] and [2].
[1], [2]
Fuel Hardware Section 3.2 of the topical states that if source term does not consider Inconel spacers then qualification must be restricted to fuel without them Fuel assemblies do not contain Inconel grid spacers, hence these were not considered.
This qualification report can therefore not be used for fuel
[3] to Holtec Letter 5014942 77 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 2 of 9 Revision 0 that contains Inconel grid spacers.
Fuel Conditions Damaged or reconstituted fuel is allowed however the method for modeling this fuel is not part of the topical Fuel to be loaded may include damaged or reconstituted fuel.
Locations for such fuel are governed by different requirements in the corresponding CoC
[1]
Inserts/non-fuel hardware (NFH) that can be loaded (PWR)
Allowable NFH are in Table 2.2 of the topical; FSAR will have more specific allowable fuel assembly characteristics; masses are in Table 3.4 of topical; however different masses can be used, if different masses are used this must be stated and loaded NFH are restricted to these masses BPRAs, TPDs and CRAs are qualified through this report.
There is no indication that any of the NFH exceed the masses in [3]. The locations and maximum number for each NFH are specified in Appendix B to this report. Burnup and cooling time limits are specified in Appendix A to this report
[3]
Neutron source assembly (NSA; PWR only)
Three options are explained within Section 3.4.3 of the topical.
(1) no limit to NSAs if source is determined to be negligible, (2) quantify and consider NSA source in calculation and number and location of NSAs is part of the content, (3) perform no evaluation and NSA are limited to 1 at the center of the basket Only a single NSA is permitted in each basket. hence no additional analyses are required.
[3]
Burnup/enrichment/cooling times and loading patterns Can vary based on qualified content, maximum burnup allowed is 68.2 GWd/mtU for PWR fuel and 65.0 GWd/mtU for BWR fuel; enrichment range is 0.5 wt% to 5.0 wt% 235U; cooling Fuel loading patterns are shown in Appendix B to this report. Burnup, enrichment and cooling time are shown in Appendix A to this report.
[4] to Holtec Letter 5014942 78 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 3 of 9 Revision 0 time is greater than or equal to 1 year Analysis Method Design Basis Assembly Topical gives the option of using assembly from Table 3.1 or 3.2 of the topical, this needs to be consistent with what is used in the FSAR The WE 17x17 from Table 3.1 of the TR [3] is used.
No justification needed SCALE Code Version Topical allows for newer version of the SCALE code system than 6.2.1. If newer versions of the code are used, topical requires a comparison per section 3.1 must be performed Source term calculations are performed with SCALE Version 6.2.1
[4]
Gamma/neutron group structures Gamma and neutron group structure is documented in Tables 3.5 and 3.6 and is allowed to change slightly per Section 3.2 and 3.3 of the topical Group Structures from Section 3.2 and 3.3 of the TR are used in the source term analyses and the radiation transport calculations No justification needed Results Acceptance criteria Dose rates must meet acceptance criteria as established in transport method defined in FSAR Acceptance criteria were taken from FSAR/TS [1],[2].
Calculations are documented in [4]. The comparison is presented in Appendix C, and shows that all criteria are met.
[4], Appendix C Justify acceptance criteria is valid if there are design changes FSAR will include criteria/method for demonstrating that acceptance criteria dose rate points are still valid if there are design changes from FSAR version where these were originally approved The FSAR specified that the acceptance criteria are applicable for a range of design variations. The design variations used here are within those ranges.
No justification needed to Holtec Letter 5014942 79 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 4 of 9 Revision 0 References
[1] Storage CoC
[2] Storage FSAR
[3] Topical report HI-2210161
[4] Calculation Report
[5] 72.48 evaluations to Holtec Letter 5014942 80 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 5 of 9 Revision 0 Appendix A: Fuel Qualification Tables (Fuel and NFH)
Fuel:
Region (See Appendix B) 1 2
3 4
5 Maximum Burnup Minimum Enrichment Minimum Cooling Time (Years) 5000 1.1 2.25 1.5 1.25 1
1 10000 1.1 3.5 2.5 2
1.5 1
15000 1.6 4
3 2.5 2
1 20000 1.6 6
3.75 3
2.5 1
25000 2.4 9
4 3.5 2.75 1.25 30000 2.4 17 5
4 3.25 1.5 35000 2.9 22 7
4.5 3.5 1.75 40000 3.2 30 9
5 3.75 1.75 45000 3.6 43 11 6
4 2
50000 3.6 51 16 8
5 2.25 55000 3.9 57 21 10 6
2.25 60000 3.9 n/a 27 14 7
2.5 65000 4.5 n/a 31 17 9
2.75 70000 4.5 n/a 36 22 11 3
to Holtec Letter 5014942 81 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 6 of 9 Revision 0 NFH:
Minimum Cooling Time (Years)
Maximum Burnup, MWd/mtU BPRAs TPDs, NSAs, CRAs, APSRs 3
30,000 180,000 10 50,000 630,000 to Holtec Letter 5014942 82 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 7 of 9 Revision 0 Appendix B: Loading Pattern NFH is permitted in the following regions:
BPRAs, TPDs All regions CRAs Regions 1 and 2 NSAs 1 NSA per cask, in Region 1 5
3 3
5 5
4 2
2 4
5 3
2 1
1 2
3 3
2 1
1 2
3 5
4 2
2 4
5 5
3 3
5 to Holtec Letter 5014942 83 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 8 of 9 Revision 0 Appendix C: Acceptance Criteria and Results of Dose Analyses Table C.1. Dose Comparison Dose Location (see Reference [2])
Maximum Calculated Dose Rate, mrem/hr Dose Rate Limit for fuel qualification, mrem/hr
([1],[2])
Storage Cask 1
100 200 2
200 300 3
200 300 4
30 100 Transfer Cask 1
500 800 2
600 900 3
500 600 4
50 100 Note that these are arbitrary values for illustrative purposes, not the results of any specific calculation.
Dose rate calculations are based on the approach outlined in Section 2.6 of [3], using the 14 patterns specified in Appendix A, and the following 14 patterns with random burnup values for each region:
to Holtec Letter 5014942 84 of 89
Appendix E to Report HI-2210161 Project EXAMPLE Report: EXAMPLE Page 9 of 9 Revision 0 Table C.2 Evaluated Burnup Sets Region (See Figure in Appendix B) 1 2
3 4
5 Calculation No.
Burnup (for corresponding enrichment and cooling times see Appendix A) 1 15000 25000 10000 10000 60000 2
55000 10000 65000 30000 70000 3
50000 30000 35000 60000 65000 4
35000 20000 20000 5000 20000 5
20000 60000 25000 40000 25000 6
55000 15000 5000 15000 40000 7
55000 50000 30000 45000 50000 8
5000 45000 15000 55000 15000 9
40000 55000 50000 70000 10000 10 30000 65000 55000 25000 35000 11 10000 35000 70000 20000 5000 12 25000 40000 60000 35000 55000 13 55000 5000 40000 50000 45000 14 45000 70000 45000 65000 30000 to Holtec Letter 5014942 85 of 89
Appendix F to Report HI-2210161 Appendix F to Report HI-2210161 Page 1 of 4 Proposed content of the qualification report Parameter Topical Requirement -
information in this column does not change and is to be carried over into the qualification report for reference use Qualified Value(s) -
Information in this column is input by the user; they must state values that are applicable to this qualification report; if a table (such as BECT) include pointer to this information Justification - Information in this column is input by the user; they must add a reference to where appropriate justification (as required by topical) such as calculation file, etc.
Storage Cask Cask Systems Specification of the casks systems that the fuel is qualified for Specify cask and basket type(s) to be qualified Reference FSAR an CoC.
They must include the reference to the topical report Shielding Design Changes and Site Specific Parameters Shielding design can be changed via 72.48, some designs have variable thickness transfer casks, however changes and/or site-specific parameters must be included in the shielding analyses used as a part of the FSAR method for dose rate calculations include reference FSAR, differences in design and/or site-specific parameters that deviate from the design basis FSAR that have been incorporated into this qualification Provide references to applicable 72.48 reports or updated FSARs as appropriate Allowable content definitions Fuel assemblies and characteristics that can be loaded Allowable fuel assemblies are in Table 2.2 of the topical; FSAR will have more specific allowable fuel assembly characteristics; different masses of assemblies may be analyzed as long as the same mass is used in the source term and dose rate analyses Include reference to TS/FSAR and Table 2.2 of the topical that include allowable assemblies; if there are restrictions associated with an assembly used as an analysis parameter (i.e. if a different/lower assembly mass Include a reference to the calculation report documenting different mass used for source term and dose rate calculations to Holtec Letter 5014942 86 of 89
Appendix F to Report HI-2210161 Appendix F to Report HI-2210161 Page 2 of 4 is used) that needs to be stated here Fuel Hardware Section 3.2 of the topical states that if source term does not consider Inconel spacers then qualification must be restricted to fuel without them State if fuel with Inconel spacers is allowed and if they were considered in the source term evaluation Include a reference to the calculation report documenting how Inconel spacers was considered within source term Fuel Conditions Damaged or reconstituted fuel is allowed however the method for modeling this fuel is not part of the topical State if and how much damaged and reconstituted fuel is allowed and include a loading pattern(s)/locations that include this information (could be an appendix to this table)
Include reference to Include reference to calculation file for source term and dose rate Inserts/non-fuel hardware (NFH) that can be loaded (PWR)
Allowable NFH are in Table 2.2 of the topical; FSAR will have more specific allowable fuel assembly characteristics; masses are in Table 3.4 of topical; however different masses can be used, if different masses are used this must be stated and loaded NFH are restricted to these masses If PWR, include inserts/NFH that are allowed to be loaded; reference topical or FSAR as appropriate, and/or include allowable masses of inserts if different If NFH mass is different from topical assumptions, include a reference to the calculation report documenting different NFH mass used for source term calculations Neutron source assembly (NSA; PWR only)
Three options are explained within Section 3.4.3 of the topical.
(1) no limit to NSAs if source is determined to be negligible, (2) quantify and consider NSA source in calculation and number and location of NSAs is part of the content, (3) perform no evaluation and NSA are limited to 1 at the center of the basket State which option is selected and if option (2) include the allowable number and location of NSAs If (1) is selected, provide reference to justification that source is negligible, if (2) is selected provide reference to analyses showing source term and compliance with dose rate limits Burnup/enrichment/cooling times and loading patterns Can vary based on qualified content, maximum burnup allowed is 68.2 GWd/mtU for Include allowable FQT or burnup/enrichment/cooling Include reference to calculation file for source term and dose rate to Holtec Letter 5014942 87 of 89
Appendix F to Report HI-2210161 Appendix F to Report HI-2210161 Page 3 of 4 PWR fuel and 65.0 GWd/mtU for BWR fuel; enrichment range is 0.5 wt% to 5.0 wt% 235U; cooling time is greater than or equal to 1 year times (can be appendix to this table)
Analysis Method Design Basis Assembly Topical gives the option of using assembly from Table 3.1 or 3.2 of the topical, this needs to be consistent with what is used in the FSAR State here which design basis assembly was chosen for source term and transport calculations No justification needed SCALE Code Version Topical allows for newer version of the SCALE code system than 6.2.1. If newer versions of the code are used, topical requires a comparison per section 3.1 must be performed State here which version of SCALE is used to perform source term calculations If SCALE version is a newer than 6.2.1, provide reference to documentation of comparison per Section 3.1 Gamma/neutron group structures Gamma and neutron group structure is documented in Tables 3.5 and 3.6 and is allowed to change slightly per Section 3.2 and 3.3 of the topical State if the group structures from the topical have been used or state what the group structures are and if they are different; similar to BECT, can be after this table in an appendix to this report Include reference to calculation file that includes justification of different group structure Results Acceptance criteria Dose rates must meet acceptance criteria as established in transport method defined in FSAR Include comparison to acceptance criteria (similar to FQT, wont fit in this box so may include as appendix, Appendix XYZ to this table, etc.)
Reference calculation file with dose calculations Justify acceptance criteria is valid if there are design changes FSAR will include criteria/method for demonstrating that acceptance criteria dose rate points are still valid if there are design changes If there are design changes, include results of criteria/method used to demonstrate acceptance Reference calculation file with dose calculations to Holtec Letter 5014942 88 of 89
Appendix F to Report HI-2210161 Appendix F to Report HI-2210161 Page 4 of 4 from FSAR version where these were originally approved criteria dose points are still acceptable Example Appendices Appendix A: FQT
[include FQTs with burnup/enrichment/cooling time]
Appendix B: Loading Pattern
[Include loading pattern, locations of damaged fuel, inserts, etc.]
Appendix C: Group structures
[Include gamma and neutron group structures if different from topical]
Appendix D: Acceptance Criteria
[Include results of dose rate calculations demonstrating that acceptance criteria has been met]
to Holtec Letter 5014942 89 of 89