Orano NCS GmbH, Margarete-von-Wrangell-StraBe 7, D-63457 Hanau U.S. Department of Transportation PHMSA attn. Rick Boyle 1200 New Jersey Ave, SE Washington, D.C. 20590 USA 0
orano Orano NCS GmbH Unsere Zeichen/ Nachricht vom 0007-SVK-2021-004 Our ref./ message dd.
lhre Zeichen/ Nachricht vom Your ref./ message dd.
Telefon Telefax E-Mail Datum
+49 61 81 501 241
+49 61 81 501 71 3 maik.hennebach@orano-ncs.com 25.11.2021 BU-D - extension of validation (cert. USA/0412/AF-96, Rev. 17) to full content of German certificate
Dear Mr. Boyle,
the revalidation of the BU-D package (with cert. USA/0412/AF-96, Rev. 17) is currently limited to a U-235 enrichment of 5.0 weight percent or less, whereas the German certificate of approval D/4305/AF-96 allows uranium oxide contents with U-235 enrichments up to 10.0 weight percent.
We hereby request the lifting of this enrichment limitation, i.e. a validation of all contents in the German certificate.
Since this change only impacts the criticality safety analysis of the package, we have attached a calculation report (0007-BBR-2021-001) that demonstrates safe subcriticality for contents with up to 10.0 weight percent enrichment (and the fissile mass limit of 650 g for these higher enrichments) even under pessimistic assumptions. The report also contains a full validation of the criticality calculation code for contents with this higher enrichment.
Since this change of the validation is needed for a project that our client Westinghouse has planned for May 2022, we would be very grateful if you could provide the validation in April 2022.
We are, of course, available for you in case you require more information or clarification on this topic.
Sincerely,
=t~~
Senior Manager Orano NCS GmbH
Attachment:
Calculation report 0007-BBR-2021-001, Rev. 0 Drano NCS GmbH, Margarete-von-Wrangell-Stra6e 7, 63457 Hanau, Deutschland Telefon: +49 (0) 61 81 501--0, Telefax: +49 (0) 61 815736 92, E-Mail:info.ncs@orano-ncs.com, www.orano-ncs.com Sitz der Gesellschaft: Hanau, RG Hanau HR B 4428, USt-ld.-Nr. DEl 13574961, Gerichtsstand: Hanau. Geschaftsfuhrer: Olaf Oldiges Bankverbindung: Societe Generale Frankfurt (BLZ 512 108 00), Konlo: 1095013031, SWIFT: SOGEDEFF, IBAN: OE 45 512108001095 0130 31 Auftrage werden auf Grundlage unserer Allgemeinen Geschaflsbedingungen iibernommen. Diese stehen Ihnen auf Wunsch zur Verfiigung.
SV-0815/02-GF 1/1