Cheryl A. Gayheart Regulatory Affairs Director 3535 Colonnade Parkway Birmingham, AL 35243 205 992 5316 cagayhea@southernco.com February 1, 2022 NL-22-0062 Docket Nos. 50-321 50-366 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request: Revise Technical Specifications to Adopt TSTF-227, Revision to EOC-RPT Pump Actions and TSTF-297, Enhancements to Required Actions for Feedwater and Main Turbine High Water Level Trip Instrumentation, EOC-RPT Instrumentation, and ATWS-RPT Instrumentation On December 13, 2021, pursuant to 10 CFR 50.90, Southern Nuclear Operating Company (SNC) requested a license amendment to Edwin I. Hatch Nuclear Plant (HNP) Unit 1 Renewed Facility Operating License DPR-57 and Unit 2 Renewed Facility Operating License NPF-5 (ADAMS Accession Number ML21347A385). The proposed amendment requested adoption of TSTF-227, Revision 0, involving clarification to the End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Technical Specifications (TS), and TSTF-297, Revision 1, involving enhancements to Feedwater and Main Turbine High Water Level Trip, EOC-RPT, and Anticipated Transient Without Scram (ATWS)-RPT TS.
Subsequent to the submittal, SNC identified the need for editorial corrections not affecting technical content as described in Enclosure 1 of this letter.
SNC requests the same approval and implementation schedule as requested in its original application. The conclusions of the No Significant Hazards Consideration Determination and Environmental Consideration contained in the original application have been reviewed and are unaffected by this supplement.
This letter contains no regulatory commitments.
If you should have any questions regarding this submittal, please contact Ryan Joyce at 205.992.6468.
U.S. Nuclear Regulatory Commission NL-22-0062 Page 2 I declare under penalty of perjury that the foregoing is true and correct. Executed on the 1st day of February 2022.
Respectfully submitted, Cheryl A. Gayheart Regulatory Affairs Director Southern Nuclear Operating Company CAG/tle
Enclosure:
Editorial Corrections - Description, Corrections, and Assessment Attachments: 1. Revised Proposed Technical Specifications Changes (Mark-Up)
- 2. Revised Technical Specifications Pages cc:
Regional Administrator, Region II NRR Project Manager - Hatch Senior Resident Inspector - Hatch Director, Environmental Protection Division - State of Georgia RType: CHA02.004
Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request: Revise Technical Specifications to Adopt TSTF-227, Revision to EOC-RPT Pump Actions and TSTF-297, Enhancements to Required Actions for Feedwater and Main Turbine High Water Level Trip Instrumentation, EOC-RPT Instrumentation, and ATWS-RPT Instrumentation Enclosure Editorial Corrections - Description, Corrections, and Assessment
Enclosure to NL-22-0062 Editorial Corrections - Description, Corrections, and Assessment E-1
=
Background===
On December 13, 2021, pursuant to 10 CFR 50.90, Southern Nuclear Operating Company (SNC) requested a license amendment to Edwin I. Hatch Nuclear Plant (HNP) Unit 1 Renewed Facility Operating License DPR-57 and Unit 2 Renewed Facility Operating License NPF-5 (ADAMS Accession Number ML21347A385). The proposed amendment requested adoption of TSTF-227, Revision 0, involving clarification to the End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Technical Specifications (TS), and TSTF-297, Revision 1, involving enhancements to Feedwater and Main Turbine High Water Level Trip, EOC-RPT, and Anticipated Transient Without Scram (ATWS)-RPT TS.
Subsequent to the submittal, SNC identified the need to editorially correct certain non-technical aspects of the request. The table below identifies provides a description of each issue as well as corrections to the original request and an assessment of each correction. Each correction has been assessed to be of an editorial nature and none impact the technical or regulatory basis for the Technical Specifications changes requested in the original submittal, dated December 13, 2021.
to this Enclosure provides the marked-up pages for HNP Units 1 and 2. provides revised (clean) TS pages. These pages have incorporated changes that address the editorial corrections described in the table below. Note that all HNP TS pages that were included in the original submittal are included in Attachments 1 and 2; this includes the pages corrected in this supplement as well as the pages that are unchanged by this supplement. All pages are included for clarity and convenience as this provides all marked-up and clean pages in a single submittal. Therefore, Attachments 1 and 2 of this Enclosure replace, in their entirety, Attachments 1 and 2, respectively, of the December 13, 2021, submittal.
Description Correction to Original Request Assessment The acronym EOC-RPT is spelled out as End of Cycle Reactor Pump Trip in two locations (first paragraph of the cover letter and page E7 of the Enclosure of the original request). It should appear as End of Cycle Recirculation Pump Trip in both locations.
Please consider End of Cycle Reactor Pump Trip to read End of Cycle Recirculation Pump Trip in the two locations identified.
It is noted the acronym is correctly spelled out in the majority of instances in the original amendment request.
This is a typographical correction.
Enclosure to NL-22-0062 Editorial Corrections - Description, Corrections, and Assessment E-2 Description Correction to Original Request Assessment In the Enclosure of the original request, Section 4.1, Applicable Regulatory Requirements, 10 CFR 50.36(c)(2)(ii)(D), Criterion 4 is misquoted.
Please consider Section 4.1, 10 CFR 50.36, Technical specifications, Item (D), of the original request to read:
(D) Criterion 4. A structure, system, or component which operating experience or probabilistic risk assessment has shown to be significant to public health and safety.
As stated in the original request, TS 3.3.4.2, Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT) Instrumentation, satisfies Criterion 4 of 10 CFR 50.36(c)(2)(ii).
Although incorrect regulation text was cited, the appropriate regulatory criterion was addressed in support of the regulatory analysis of the proposed changes to the TS.
Therefore, this editorial correction does not impact the technical or regulatory basis for the proposed changes to the HNP TS.
In the Enclosure of the original request, Section 4.1, Applicable Regulatory Requirements, a paragraph addressing the requirements of 10 CFR 50.62, Requirements for reduction of risk from anticipated transients without scram (ATWS) events for light-water-cooled nuclear power plants, erroneously cited 10 CFR 50.36(c)(5). The paragraph should cite 10 CFR 50.62(c)(5).
In Section 4.1, 10 CFR 50.62, Requirements for reduction of risk from anticipated transients without scram (ATWS) events for light-water-cooled nuclear power plants, please consider 10 CFR 50.36(c)(5) to read 10 CFR 50.62(c)(5) in both locations.
Although the incorrect regulation number was cited, the appropriate regulatory requirement was addressed in support of the regulatory analysis of the proposed changes to the TS. Therefore, this editorial correction does not impact the technical or regulatory basis for the proposed changes to the HNP TS.
Enclosure to NL-22-0062 Editorial Corrections - Description, Corrections, and Assessment E-3 Description Correction to Original Request Assessment In the Attachments of the original request, the markups and clean-typed pages for HNP Unit 1, TS 3.3.4.2, Note for Required Action D.1 did not match the TSTF-297 proposed wording. The TSTF-297 proposed wording, as well as the wording proposed in Section 2.3 of the Enclosure of the original request, read Only applicable if inoperable channel is the result of an inoperable RPT breaker. In the Attachments of the original request, the second instance of the word inoperable was inadvertently omitted from the Required Action D.1 Note. to this submittal provides the affected TS pages revised to correctly show the HNP TS 3.3.4.2, Required Action D.1 Note, i.e., the previously omitted word inoperable is included in the Note. For convenience, Attachments 1 and 2 contain all the TS pages included in the original request.
The HNP Unit 1, TS 3.3.4.2, Required Action D.1 Note is corrected to be consistent with the TSTF-297 proposed wording.
This is a typographical correction.
In the Attachments of the original request, the markups and clean-typed pages for HNP Unit 1 and Unit 2, TS 3.3.2.2 Note for Required Action C.1 did not match the wording proposed in Section 2.3 of the Enclosure of the original request. Specifically, the markups and clean-typed pages for TS 3.3.2.2 omitted the word an in the Note for Required Action C.1. to this submittal provides the affected TS pages revised to correctly show the HNP Unit 1 and Unit 2, TS 3.3.2.2 Note for Required Action C.1, i.e., the previously omitted word an is included in the Note. For convenience, Attachments 1 and 2 contain all the TS pages included in the original request.
The addition of the word an does not change the intent of the Note but is a grammatical improvement.
This is a typographical correction.
Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request: Revise Technical Specifications to Adopt TSTF-227, Revision to EOC-RPT Pump Actions and TSTF-297, Enhancements to Required Actions for Feedwater and Main Turbine High Water Level Trip Instrumentation, EOC-RPT Instrumentation, and ATWS-RPT Instrumentation Revised Proposed Changes (Mark-Up)
Feedwater and Main Turbine Trip High Water Level Instrumentation 3.3.2.2 HATCH UNIT 1 3.3-21 Amendment No. 266 3.3 INSTRUMENTATION 3.3.2.2 Feedwater and Main Turbine Trip High Water Level Instrumentation LCO 3.3.2.2 Three channels of feedwater and main turbine trip instrumentation shall be OPERABLE.
APPLICABILITY:
7+(50$/32:(5% RTP.
ACTIONS
NOTE------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One feedwater and main turbine high water level trip channel inoperable.
A.1 Place channel in trip.
7 days B.
Two or more feedwater and main turbine high water level trip channels inoperable.
B.1 Restore feedwater and main turbine high water level trip capability.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> C.
Required Action and associated Completion Time not met.
C.1
NOTE-----------
Only applicable if inoperable channel is the result of an inoperable feedwater pump valve or main turbine stop valve.
Remove affected feedwater pump(s) and main turbine valve(s) from service.
OR C.2 Reduce THERMAL POWER to < 24% RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 1 3.3-28 Amendment No. 266 3.3 INSTRUMENTATION 3.3.4.1 End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation LCO 3.3.4.1
- a.
Two channels per trip system for each EOC-RPT instrumentation Function listed below shall be OPERABLE:
- 1.
Turbine Stop Valve (TSV) - Closure; and
- 2.
Turbine Control Valve (TCV) Fast Closure, Trip Oil Pressure - Low.
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for inoperable EOC-RPT as specified in the COLR are made applicable.
APPLICABILITY:
THERMAL 32:(5573
ACTIONS
NOTE------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more required channels inoperable.
A.1 Restore channel to OPERABLE status.
OR A.2
NOTE------------
Not applicable if inoperable channel is the result of an inoperable breaker.
Place channel in trip.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 72 hours (continued)
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 1 3.3-29 Amendment No. 266 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME B.
One or more Functions with EOC-RPT trip capability not maintained.
AND MCPR limit for inoperable EOC-RPT not made applicable.
B.1 Restore EOC-RPT trip capability.
OR B.2 Apply the MCPR limit for inoperable EOC-RPT as specified in the COLR.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 hours C.
Required Action and associated Completion Time not met.
C.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the associated affected recirculation pump from service.
OR C.2 Reduce THERMAL POWER to < 27.6%
RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours SURVEILLANCE REQUIREMENTS
NOTE------------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains EOC-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.1.1 Perform CHANNEL FUNCTIONAL TEST.
In accordance with the Surveillance Frequency Control Program (continued)
ATWS-RPT Instrumentation 3.3.4.2 HATCH UNIT 1 3.3-32 Amendment No. 266 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C.
Both Functions with ATWS-RPT trip capability not maintained.
C.1 Restore ATWS-RPT trip capability for one Function.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> D.
Required Action and associated Completion Time not met.
D.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the associated affected recirculation pump from service.
OR D.2 Be in MODE 2.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 6 hours SURVEILLANCE REQUIREMENTS
NOTE------------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains ATWS-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.2.1 Perform CHANNEL CHECK.
In accordance with the Surveillance Frequency Control Program (continued)
Feedwater and Main Turbine Trip High Water Level Instrumentation 3.3.2.2 HATCH UNIT 2 3.3-21 Amendment No. 210 3.3 INSTRUMENTATION 3.3.2.2 Feedwater and Main Turbine Trip High Water Level Instrumentation LCO 3.3.2.2 Three channels of feedwater and main turbine trip instrumentation shall be OPERABLE.
APPLICABILITY:
7+(50$/32:(5 24% RTP.
ACTIONS
NOTE------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One feedwater and main turbine high water level trip channel inoperable.
A.1 Place channel in trip.
7 days B.
Two or more feedwater and main turbine high water level trip channels inoperable.
B.1 Restore feedwater and main turbine high water level trip capability.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> C.
Required Action and associated Completion Time not met.
C.1
NOTE-----------
Only applicable if inoperable channel is the result of an inoperable feedwater pump valve or main turbine stop valve.
Remove affected feedwater pump(s) and main turbine valve(s) from service.
OR C.2 Reduce THERMAL POWER to < 24% RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 2 3.3-28 Amendment No. 210 3.3 INSTRUMENTATION 3.3.4.1 End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation LCO 3.3.4.1
- a.
Two channels per trip system for each EOC-RPT instrumentation Function listed below shall be OPERABLE:
- 1.
Turbine Stop Valve (TSV) - Closure; and
- 2.
Turbine Control Valve (TCV) Fast Closure, Trip Oil Pressure - Low.
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for inoperable EOC-RPT as specified in the COLR are made applicable.
APPLICABILITY:
7+(50$/32:(5 27.6% RTP.
ACTIONS
NOTE----------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more required channels inoperable.
A.1 Restore channel to OPERABLE status.
OR A.2
NOTE-----------
Not applicable if inoperable channel is the result of an inoperable breaker.
Place channel in trip.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 72 hours (continued)
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 2 3.3-29 Amendment No. 210 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME B.
One or more Functions with EOC-RPT trip capability not maintained.
AND MCPR limit for inoperable EOC-RPT not made applicable.
B.1 Restore EOC-RPT trip capability.
OR B.2 Apply the MCPR limit for inoperable EOC-RPT as specified in the COLR.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 hours C.
Required Action and associated Completion Time not met.
C.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the associated affected recirculation pump from service.
OR C.2 Reduce THERMAL POWER to < 27.6%
RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours SURVEILLANCE REQUIREMENTS
NOTE----------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains EOC-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.1.1 Perform CHANNEL FUNCTIONAL TEST.
In accordance with the Surveillance Frequency Control Program (continued)
ATWS-RPT Instrumentation 3.3.4.2 HATCH UNIT 2 3.3-32 Amendment No. 210 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C.
Both Functions with ATWS-RPT trip capability not maintained.
C.1 Restore ATWS-RPT trip capability for one Function.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> D.
Required Action and associated Completion Time not met.
D.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the associated affected recirculation pump from service.
OR D.2 Be in MODE 2.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 6 hours SURVEILLANCE REQUIREMENTS
NOTE----------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains ATWS-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.2.1 Perform CHANNEL CHECK.
In accordance with the Surveillance Frequency Control Program (continued)
Edwin I. Hatch Nuclear Plant - Units 1 and 2 Supplement to License Amendment Request: Revise Technical Specifications to Adopt TSTF-227, Revision to EOC-RPT Pump Actions and TSTF-297, Enhancements to Required Actions for Feedwater and Main Turbine High Water Level Trip Instrumentation, EOC-RPT Instrumentation, and ATWS-RPT Instrumentation Revised Technical Specifications Pages
Feedwater and Main Turbine Trip High Water Level Instrumentation 3.3.2.2 HATCH UNIT 1 3.3-21 Amendment No.
3.3 INSTRUMENTATION 3.3.2.2 Feedwater and Main Turbine Trip High Water Level Instrumentation LCO 3.3.2.2 Three channels of feedwater and main turbine trip instrumentation shall be OPERABLE.
APPLICABILITY:
7+(50$/32:(5% RTP.
ACTIONS
NOTE------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One feedwater and main turbine high water level trip channel inoperable.
A.1 Place channel in trip.
7 days B.
Two or more feedwater and main turbine high water level trip channels inoperable.
B.1 Restore feedwater and main turbine high water level trip capability.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> C.
Required Action and associated Completion Time not met.
C.1
NOTE-----------
Only applicable if inoperable channel is the result of an inoperable feedwater pump valve or main turbine stop valve.
Remove affected feedwater pump(s) and main turbine valve(s) from service.
OR C.2 Reduce THERMAL POWER to < 24% RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 1 3.3-28 Amendment No.
3.3 INSTRUMENTATION 3.3.4.1 End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation LCO 3.3.4.1
- a.
Two channels per trip system for each EOC-RPT instrumentation Function listed below shall be OPERABLE:
- 1.
Turbine Stop Valve (TSV) - Closure; and
- 2.
Turbine Control Valve (TCV) Fast Closure, Trip Oil Pressure - Low.
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for inoperable EOC-RPT as specified in the COLR are made applicable.
APPLICABILITY:
7+(50$/32:(5573
ACTIONS
NOTE------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more required channels inoperable.
A.1 Restore channel to OPERABLE status.
OR A.2
NOTE------------
Not applicable if inoperable channel is the result of an inoperable breaker.
Place channel in trip.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 72 hours (continued)
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 1 3.3-29 Amendment No.
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME B.
One or more Functions with EOC-RPT trip capability not maintained.
AND MCPR limit for inoperable EOC-RPT not made applicable.
B.1 Restore EOC-RPT trip capability.
OR B.2 Apply the MCPR limit for inoperable EOC-RPT as specified in the COLR.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 hours C.
Required Action and associated Completion Time not met.
C.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the affected recirculation pump from service.
OR C.2 Reduce THERMAL POWER to < 27.6%
RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours SURVEILLANCE REQUIREMENTS
NOTE------------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains EOC-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.1.1 Perform CHANNEL FUNCTIONAL TEST.
In accordance with the Surveillance Frequency Control Program (continued)
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 1 3.3-30 Amendment No.
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.3.4.1.2 Verify TSV - Closure and TCV Fast Closure, Trip Oil Pressure - Low Functions are not bypassed ZKHQ7+(50$/32:(5LV573
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.3 Perform CHANNEL CALIBRATION. The Allowable Values shall be:
TSV - &ORVXUHFORVHGDQG TCV Fast Closure, Trip Oil Pressure - /RZSVLJ
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.4 Perform LOGIC SYSTEM FUNCTIONAL TEST including breaker actuation.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.5
NOTE------------------------------
Breaker interruption time may be assumed from the most recent performance of SR 3.3.4.1.6.
Verify the EOC-RPT SYSTEM RESPONSE TIME is within limits.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.6 Determine RPT breaker interruption time.
In accordance with the Surveillance Frequency Control Program
ATWS-RPT Instrumentation 3.3.4.2 HATCH UNIT 1 3.3-32 Amendment No.
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C.
Both Functions with ATWS-RPT trip capability not maintained.
C.1 Restore ATWS-RPT trip capability for one Function.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> D.
Required Action and associated Completion Time not met.
D.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the affected recirculation pump from service.
OR D.2 Be in MODE 2.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 6 hours SURVEILLANCE REQUIREMENTS
NOTE------------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains ATWS-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.2.1 Perform CHANNEL CHECK.
In accordance with the Surveillance Frequency Control Program (continued)
ATWS-RPT Instrumentation 3.3.4.2 HATCH UNIT 1 3.3-33 Amendment No.
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.3.4.2.2 Perform CHANNEL FUNCTIONAL TEST.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.2.3 Perform CHANNEL CALIBRATION. The Allowable Values shall be:
- a.
ATWS-537/HYHO-73 inches; and
- b.
Reactor Steam Dome Pressure -
+LJKSVLJ
In accordance with the Surveillance Frequency Control Program SR 3.3.4.2.4 Perform LOGIC SYSTEM FUNCTIONAL TEST including breaker actuation.
In accordance with the Surveillance Frequency Control Program
Feedwater and Main Turbine Trip High Water Level Instrumentation 3.3.2.2 HATCH UNIT 2 3.3-21 Amendment No.
3.3 INSTRUMENTATION 3.3.2.2 Feedwater and Main Turbine Trip High Water Level Instrumentation LCO 3.3.2.2 Three channels of feedwater and main turbine trip instrumentation shall be OPERABLE.
APPLICABILITY:
7+(50$/32:(5 24% RTP.
ACTIONS
NOTE------------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One feedwater and main turbine high water level trip channel inoperable.
A.1 Place channel in trip.
7 days B.
Two or more feedwater and main turbine high water level trip channels inoperable.
B.1 Restore feedwater and main turbine high water level trip capability.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> C.
Required Action and associated Completion Time not met.
C.1
NOTE-----------
Only applicable if inoperable channel is the result of an inoperable feedwater pump valve or main turbine stop valve.
Remove affected feedwater pump(s) and main turbine valve(s) from service.
OR C.2 Reduce THERMAL POWER to < 24% RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 2 3.3-28 Amendment No.
3.3 INSTRUMENTATION 3.3.4.1 End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation LCO 3.3.4.1
- a.
Two channels per trip system for each EOC-RPT instrumentation Function listed below shall be OPERABLE:
- 1.
Turbine Stop Valve (TSV) - Closure; and
- 2.
Turbine Control Valve (TCV) Fast Closure, Trip Oil Pressure - Low.
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for inoperable EOC-RPT as specified in the COLR are made applicable.
APPLICABILITY:
7+(50$/32:(5 27.6% RTP.
ACTIONS
NOTE----------------------------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more required channels inoperable.
A.1 Restore channel to OPERABLE status.
OR A.2
NOTE-----------
Not applicable if inoperable channel is the result of an inoperable breaker.
Place channel in trip.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 72 hours (continued)
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 2 3.3-29 Amendment No.
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME B.
One or more Functions with EOC-RPT trip capability not maintained.
AND MCPR limit for inoperable EOC-RPT not made applicable.
B.1 Restore EOC-RPT trip capability.
OR B.2 Apply the MCPR limit for inoperable EOC-RPT as specified in the COLR.
2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> 2 hours C.
Required Action and associated Completion Time not met.
C.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the affected recirculation pump from service.
OR C.2 Reduce THERMAL POWER to < 27.6%
RTP.
4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> 4 hours SURVEILLANCE REQUIREMENTS
NOTE----------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains EOC-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.1.1 Perform CHANNEL FUNCTIONAL TEST.
In accordance with the Surveillance Frequency Control Program (continued)
EOC-RPT Instrumentation 3.3.4.1 HATCH UNIT 2 3.3-30 Amendment No.
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.3.4.1.2 Verify TSV - Closure and TCV Fast Closure, Trip Oil Pressure - Low Functions are not bypassed ZKHQ7+(50$/32:(5LV 27.6% RTP.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.3 Perform CHANNEL CALIBRATION. The Allowable Values shall be:
TSV - &ORVXUH 10% closed; and TCV Fast Closure, Trip Oil Pressure - /RZ 600 psig.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.4 Perform LOGIC SYSTEM FUNCTIONAL TEST including breaker actuation.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.5
NOTE-------------------------------
Breaker interruption time may be assumed from the most recent performance of SR 3.3.4.1.6.
Verify the EOC-RPT SYSTEM RESPONSE TIME is within limits.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.1.6 Determine RPT breaker interruption time.
In accordance with the Surveillance Frequency Control Program
ATWS-RPT Instrumentation 3.3.4.2 HATCH UNIT 2 3.3-32 Amendment No.
ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C.
Both Functions with ATWS-RPT trip capability not maintained.
C.1 Restore ATWS-RPT trip capability for one Function.
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> D.
Required Action and associated Completion Time not met.
D.1
NOTE------------
Only applicable if inoperable channel is the result of an inoperable RPT breaker.
Remove the affected recirculation pump from service.
OR D.2 Be in MODE 2.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 6 hours SURVEILLANCE REQUIREMENTS
NOTE----------------------------------------------------------
When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains ATWS-RPT trip capability.
SURVEILLANCE FREQUENCY SR 3.3.4.2.1 Perform CHANNEL CHECK.
In accordance with the Surveillance Frequency Control Program (continued)
ATWS-RPT Instrumentation 3.3.4.2 HATCH UNIT 2 3.3-33 Amendment No.
SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.3.4.2.2 Perform CHANNEL FUNCTIONAL TEST.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.2.3 Perform CHANNEL CALIBRATION. The Allowable Values shall be:
- a.
ATWS-537/HYHO -73 inches; and
- b.
Reactor Steam Dome Pressure -
+LJK 1175 psig.
In accordance with the Surveillance Frequency Control Program SR 3.3.4.2.4 Perform LOGIC SYSTEM FUNCTIONAL TEST including breaker actuation.
In accordance with the Surveillance Frequency Control Program