B. Beasley UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 MEMORANDUM TO:

William Kennedy, Acting Chief Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Lucieann Vechioli, Project Manager Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE JANUARY 10, 2022, PUBLIC MEETING BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION STAFF AND X ENERGY LLC REGARDING THE XE-100 MAINTENANCE STAFFING OPTIMIZATION WHITE PAPER On January 10, 2022, the U.S. Nuclear Regulatory Commission (NRC) staff held a virtual observation public meeting with representatives from X Energy LLC (X-energy). The purpose of the meeting was for X-energy to provide an overview of their Xe-100 Maintenance Staffing Optimization white paper that was submitted to the NRC on December 28, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21362A751). The meeting notice can be located at ADAMS Accession No. ML21350A168 and the presentation slides under ADAMS Accession No. ML22011A147. The enclosure to this document provides the list of meeting attendees.

The meeting began with an overview of the Xe-100 design and its licensing approach. The discussion was followed by X-energy staff presentation about the approach developed to determine and optimize the maintenance staffing plan for the Xe-100 site. The white paper summarizes the philosophy and strategy developed for the maintenance of the Xe-100 reactor.

The methodology was developed by X-energy and the Electric Power Research Institute (EPRI).

The time and personnel requirements were assessed through the use of the EPRI Preventive Maintenance Basis Database, EPRI Member experience, and EPRI Subject Matter Experts. X-energy pointed out that the information provided in the white paper is preliminary and subject to change as the design progresses. X-energy will revise and submit other reports as more information becomes available.

CONTACT: Lucieann Vechioli, NRR/DANU (301) 415-6035 February 16, 2022 Signed by Vechioli, Lucieann on 02/16/22

W. Kennedy 1/299/2X-energy provided the status of the ARPA-E Gemina Project regarding using a Digital Twin tools system to reduce fixed operation and maintenance costs. X-energy also discussed their maintenance strategy which was determined using the criticality ranking created from the Xe-100 equipment reliability process, that identifies the importance, value, and impact of all the structures, systems and components of the Xe-100 reactor design.

During the discussion, X-energy staff explained the different roles of the onsite and offsite personnel that will be performing maintenance at the Xe-100 plants. The discussion included examples and rationale of the maintenance staffing analysis process.

The meeting included an open discussion where the NRC staff asked questions about the content in the report. One of the questions raised was about the type of controls that will be in place to monitor tasks and confirm that they are done correctly. X-energy and EPRI explained that they are currently working on definining this process and will provide the information to the NRC once it is available.

At the end of the meeting, the NRC staff informed X-energy that it will develop informal observations on the white paper. The schedule for developing the feedback will be provided to X-energy within a month of the meeting.

Enclosure:

List of Attendees

ML22021B664 NRC-001 OFFICE NRR/DANU/UARL/PM NRR/DANU/UARL/LA NRR/DANU/UARL/BC (A) NRR/DANU/UARL/PM NAME LVechioli CSmith (SLent for)

WKennedy LVechioli DATE 1/26/2022 2/14/2022 2/16/2022 2/16/2022

Enclosure Public Meeting between the U.S. Nuclear Regulatory Commission staff and X Energy LLC January 10, 2022 List of Attendees Name Organization Brian Green U.S. Nuclear Regulatory Commission (NRC)

William Kennedy NRC Justin Vazquez NRC Kenneth Erwin NRC Lucieann Vechioli NRC Brian Tindell NRC Maurin Scheetz NRC Julie Ezell NRC Niav Hughes NRC John Hughey NRC Kerri Kavanaugh NRC Aaron Armstrong NRC Ian Davis NRC Travis Chapman X Energy LLC (X-energy)

Ingrid Nordby X-energy Tony Qualantone X-energy Tom Braudt X-energy Jon Facemire X-energy Raymond Wang X-energy Charlotte Geiger X-energy Steve Vaughn X-energy Andrew Bridges X-energy Tony Qualantone X-energy Greg Crannicl X-energy Paul Hippely X-energy James Park X-energy Alex Brazalovich X-energy Andrew Rodgers X-energy Clevin Canales X-energy Vicki Morgan X-energy Shawn Hanvy X-energy Dan Williamson X-energy (Contractor)

Eddie Grant X-energy (Contractor)

David Rackiewicz X-energy (Contractor)

Pareez Golub Sargent & Lundy Maury Pressburger Sargent & Lundy David Daigle Tennessee Valley Authority

2 Ian Gifford Terrapower Curt Nehrkorn ARPA-E Contractor Booz/Allen And Hamilton William Cohen Member of the publiC