Vogtle Unit 2 Pre-Submittal for Westinghouse Increased Enrichment Accident Tolerant Fuel Lead Test Assemblies January 27, 2022

2 Introductions and Purpose

  • Introductions
  • Purpose of the Meeting Early engagement meeting with NRC to discuss plans for implementation of Westinghouse lead test assemblies (LTAs) at Vogtle Unit 2.

3 Agenda

  • Description of LTA Program
  • Overview of Primary Analytical Impacts
  • Review of Spent Fuel Pool and New Fuel Storage Criticality Requirements
  • Overview of License Amendment Request
  • Timeline and Future Plans
  • Questions and Adjourn

4 Vogtle Units 1 and 2 Overview

  • 193 Fuel Assemblies
  • 17x17 array
  • 264 rods/assembly
  • 0.360 rod outside diameter
  • 12 active fuel height
  • 3625.6 megawatts thermal

5 Description of LTA Program

  • Initial Goals of program (within scope of proposed license amendment request (LAR)):
  • Irradiate higher enriched fuel in a commercial reactor to generate data in support of future licensing applications
  • Future Goal of program (outside scope of proposed LAR):
  • Support licensing applications for higher burnup fuels
  • Four rods each with enrichment up to 6 w/o U-235
  • AXIOM high performance fuel rod cladding
  • EnCore chromium coated cladding (one or more rods may be uncoated)
  • ADOPT' doped fuel material for non-IFBA (Integral Fuel Burnable Absorbers) rods
  • Standard (undoped) fuel material for IFBA rods ADOPT, AXIOM, and EnCore are trademarks or registered trademarks of Westinghouse Electric Company LLC, its affiliates and/or its subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved.

Unauthorized use is strictly prohibited.

Overview of Primary Analytical Impacts

7 Overview of Licensed Methods

  • ATF materials will be modeled by making conservative adjustments to codes and methods where necessary
  • Modeling will be consistent with descriptions in NRC-approved topical reports (where available) or based on the most recent level of characterization for materials not yet approved (from Westinghouse development or NRC interactions on ongoing topical report reviews)
  • Some NRC-approved methods outside Vogtle current licensing basis used solely to assess performance of the LTAs
  • PAD5 fuel performance models and design criteria
  • PARAGON2 transport code
  • Justification for current LOCA evaluation model (BASH) will be provided relative to the NRC restrictions on its use; assessments will be performed to show LTAs and co-resident fuel meet 50.46 acceptance criteria
  • NRC-approved VIPRE-W thermo/hydraulic methods used for LTAs

8 Key Analytical Impacts of the LTAs

  • LTAs will lead the core (have highest power) during portions of steady-state operation and during some transient conditions
  • A separate LAR will be required to achieve high fuel rod burnup limits (e.g. 68 or 75 GWD/MTU).

Review of Spent Fuel Pool and New Fuel Storage Criticality Requirements

10 Background on Current Spent Fuel Pool and New Fuel Storage Licensing Basis

  • 10 CFR 70.24 with NRC-approved exemptions for Spent Fuel Pool (SFP)
  • No enrichment limit
  • 10 CFR 50.68 not part of licensing basis; no exemption required
  • TS maximum U-235 enrichment of 5.0 w/o U-235 in the SFP and 5.05 w/o U-235 in the New Fuel Storage Racks (NFSRs)
  • Multiple SFP Storage Configurations
  • SFP Analysis of Record:
  • Does contain Soluble Boron Credit
  • Does contain Burnup Credit
  • Contains fresh IFBA Credit for a storage configuration

11 LTAs - Criticality Focus

  • The following LTA characteristics are beyond current analysis of record (AoR) scope, and will be addressed in LAR:
  • Increased enrichment
  • ADOPT' pellets
  • Intent to provide acceptable storage requirements using the AoR storage configurations (or a subset thereof) via Comparative Reactivity Analysis
  • Use modern codes - Scale 6.2+ with associated cross section libraries
  • Separate storage evaluations for fresh fuel analysis (SFP & NFSRs) and burned fuel analysis

Overview of License Amendment Request

13 Applicability of Regulatory Framework

  • ATF fuel materials are being NRC reviewed within current framework
  • EnCore chromium coated cladding to be submitted
  • NRC ATF Project Plan, Version 1.2 (ML21243A298), Section 6, While higher burnup and increased enrichment may affect how licensees demonstrate compliance with regulatory requirements, the principal design and performance requirements of the GDC remain applicable

14 Proposed License Amendment Request

  • Add description of the LTAs, key features, materials
  • LTA specific storage requirements
  • Potential Changes
  • Revise TS 3.7.18 - Fuel Assembly Storage in the Fuel Storage Pool
  • Possible addition of penalty factor on the burnup requirement specific to the LTAs
  • The LTAs will comply with all other TS requirements

15 Exemptions Pursuant to 10 CFR 50.12

  • Since the LTAs will lead the core, a request for exemption from 10 CFR 50.46 and Appendix K will be submitted
  • Request exemption from the fuel cladding material and to apply Baker-Just equation to AXIOM cladding
  • All other aspects of the regulations will continue to be observed and compliance to applicable GDC will be demonstrated
  • For SFP storage of the LTAs, the Vogtle licensing basis continues to be 10 CFR 70.24 with NRC-approved exemptions
  • Inadvertent or accidental criticality will be precluded through compliance with the proposed TS, the geometric spacing of fuel assemblies in the new fuel storage facility and spent fuel storage pool, and administrative controls imposed on fuel handling procedure
  • Exemptions to 10 CFR 70.24 continue to remain valid
  • No exemption from 10 CFR 50.68(b)(7) will be needed

16 Assessment of Radiological Consequences

  • Southern Nuclear is in the process of submitting a LAR to implement Alternate Source Term (AST) into the radiological consequences licensing basis
  • Planned submittal date 3Q22
  • LTA radiological consequence assessment will be performed based on AST models
  • Impact to radiological consequences expected to be negligible

LTA Transport

18 LTA Transport

  • LTA will be transported in the Traveller-B Package
  • US NRC license USA/9380/B(U)F-96
  • Amendment submitted to NRC August 2021 with planned NRC approval by March 2022
  • Traveller-B amendment LTA contents
  • 6% U-235 enriched fuel assembly
  • ADOPT' fuel, Cr-coated cladding
  • Additional content and safety analysis report (SAR) revisions
  • No special arrangement, exemptions, or one-time transport approval required, as all regulatory requirements are met
  • 71.55(g) is not applicable
  • Westinghouse is the NRC applicant and the consignor (i.e., shipper of record) of material for DOT shipper requirements

Timeline and Future Plans

20 Projected Timeline Activity Projected Completion Engineering and Analysis June 2022 Additional NRC Touchpoints As needed Submittal of LTA LAR & Exemption Early 3Q2022 Submittal of AST LAR 3Q2022 NRC Approval of LTA LAR & Exemption August 2023 Delivery of LTAs to Site September 2023 Startup Unit 2 Cycle 24 November 2023 Reload and Start of Unit 2 Cycle 25 Spring 2025

Questions?