ML22020A406

From kanterella
Jump to navigation Jump to search
Public Meeting Notice for Field Flash Selector Switch Preventative Maintenance Regulatory Conference
ML22020A406
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/21/2022
From: Richard Skokowski
Engineering Branch 3
To:
References
EA-21-105
Download: ML22020A406 (4)


Text

NOTICE OF PUBLIC MEETING Licensee(s):

Energy Harbor Nuclear Corp. 55 Facility(ies):

Davis-Besse Nuclear Power Station Docket No(s):

05000346 Licesee No(s):

NPF-3 EA No(s):

EA-21-105 Date and Time:

Tuesday, February 1, 2022 9:00 AM CST Location:

U.S Nuclear Regulatory Commission Main Conference Room 2443 Warrenville Road, Suite 210 Lisle, Illinois 60532-4362 (Due to COVID-19 conditions public participation will be via teleconference only)

Purpose:

The purpose of this Regulatory Conference is to discuss the risk significance of a potential greater than green finding and associated apparent violation involving an apparent failure of the licensee to establish and implement written procedures covering the preventive maintenance schedules for the inspection of equipment. Specifically, a preventive maintenance schedule for inspection of the field flash selector switch contacts for the safety-related Emergency Diesel Generators.

NRC Attendees:

J. Giessner, Regional Administrator M. Shuaibi, Deputy Regional Administrator M. Franovich, Director of the Division of Risk Assessment D. Curtis, Deputy Director of the Division of Reactor Safety J. Lara, Director of the Division of Reactor Projects R. Felts, Deputy Director of the Division of Reactor Oversight S. Lewman, Acting Enforcement Officer R. Chazell, Regional Counsel J. Peralta, Office of Enforcement Branch Chief B. Dickson, Division of Reactor Projects Branch Chief January 21, 2022

2 R. Skokowski, Division of Reactor Safety Branch Chief W. Morton, Electrical Engineering Branch, Branch Chief A. Master, Reactor Assessment Branch, Branch Chief M. Hayes, Advanced Reactors Engineering Branch 1, Branch Chief J. Hanna, Senior Risk Analyst L. Kozak, Senior Risk Analyst K. Lambert, Senior Enforcement Specialist D. Jones, Senior Enforcement Specialist K. Miller, Senior Electrical Engineer R. Rodriguez, Reliability and Risk Analyst K. Barclay, Reactor Inspector K. Fay, Reactor Inspector Others, as designated Licensee Attendees:

Terry Brown, Site Vice President Greg Michael, Engineering Director Cleve Wilson, Strategic Engineering Manager Brian Zsenyuk, Strategic Engineering Supervisor Alan Filipiak, Assistant Operations Manager, active SRO License Dan Harnett, Operations Manager Rob Oesterle, Regulatory Compliance Manager Aaron Quaderer, Probabilistic Risk Analysis Engineer John Cunningham, MPR Associates Public Participation:

This conference is open to public observation and questions following the formal portion of the meeting via teleconference only due to COVID-19 pandemic restrictions.

Phone Number: +1 301-576-2978, Passcode: 357032014#

3 Meeting

Contact:

Richard Skokowski, Branch Chief DRS, Engineering Branch 3 630-829-9833 Richard.Skokowski@nrc.gov Approved by: ____________________________

Richard Skokowski, Branch Chief Engineering Branch 3 Division of Reactor Safety Signed by: ____________________________

David Curtis, Deputy Director Division of Reactor Safety Signed by Skokowski, Richard on 01/21/22 Signed by Curtis, David on 01/21/22

4 DISTRIBUTION:

Jack Giessner Mohammed Shuaibi David Curtis Michelle Hayes Mark Lombard Tania Martinez-Navedo Juan Peralta David Furst Shelbie Lewman Kenneth Lambert Russell Felts Brian Hughes Stacy Prasad OEWeb.Resource RidsOeMailCenter Resource ADAMS Accession Number: ML22020A406 Publicly Available Non-Publicly Available Sensitive Non-Sensitive OFFICE RIII RIII RIII NAME RSkokowski:mb SLewman DCurtis DATE 01/21/2022 01/21/2022 01/21/2022 OFFICIAL RECORD COPY