Text
SCOTT A THOMPSON Executive Director O
k l
A H
O M
A 0£14li11£NT )f fNY'IC'IM!lll.ll :lllAilTf OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY CERTIFIED MAIL: RETURN RECEIPT REQUESTED May 19, 2020 Mr. Jeff Lux, Senior Project Manager Environmental Properties Management LLC 615 N. Hudson; Suite 200 Oklahoma City, OK 73102 Re:
2020 Groundwater Flow Model Review Cimarron Environmental Response Tmst
Dear Mr. Lux:
Thank you for the subject Groundwater Flow Model Review. DEQ is satisfied with the report.
KEVIN STITT Governor To recap, the model update was to simulate the effect of extraction wells screened only opposite groundwater containing Uranium at levels higher than the dtinking water standard (MCL).
For the Western Alluvial Area (W AA) the 2020 model split the alluvium, which the 2016 model counted as one layer, into two layers of equal thickness. To simulate the fining-upward sequence observed in the alluvium, the 2020 model allocated 7 5% of the transmissivity to the lower half of the alluvium and 25% in the upper half.
For Burial Area I (BA l) the 2016 model split the alluvium into 8 !aye rs. The 2020 model evenly allocated 75% of the total transmissivity to the bottom four of those layers, and 25% to the upper four.
Please contact me at ( 405) 702-5132 if you have questions or wish to schedule further discussion.
Sincerely,
b-
f,,/
J Paul Davis Environmental Programs Specialist Land Protection Division c.
Bill Halliburto n, EPM Ken Kalman, NRC John Tappert, NRC 707 NORTH ROBINSON, PO. BOX 1677, OKLAHOMACl1Y, OKLAHOMA 73101-1677 p1e.ase recyc1e
Mr. JeffLux May 20, 2020 Page 2 Robert Yalen, U.S. Depatiment of Justice Hollis Luzecky, EPA Jennifer Lewis, Office of the Attorney General of Oklahoma Hillary Young, DEQ LPD Carol Paden, DEQ WQD Pam Dizikes, Office of the General Counsel