NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9387 0

71-9387 USA/9387/B(U)-96 1

OF 3

2.

PREAMBLE

a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION

a.

ISSUED TO (Name and Address)

b.

TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Industrial Nuclear Company, Inc.

14320 Wicks Blvd.

San Leandro, CA 94577 Industrial Nuclear Company application dated November 1, 2021.

4.

CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

5. (a)

Packaging (1)

Model No.: OP-RMSC (2)

Description The Outer Package-Raw Material Shipping Container, (Model No. OP-RMSC) is designed to transport special form radioactive materials in the Raw Material Shipping Container (RMSC). The RMSC is fabricated from a stainless steel pipe with a stainless steel plate welded at one end. Primary shielding is provided by a tungsten alloy located inside the stainless steel pipe. The RMSC lid is a stainless steel plate.

The upper portion of the RMSC cavity is formed by stainless steel pipe into which tungsten alloy shielding is placed to provide shielding above the lower portion of the RMSC cavity wherein the special form contents, in a special form capsule holder, are located. The lid is secured to the RMSC using six 3/8-16 UNC-2A hex bolts. The OP-RMSC inner cavity, in which the RMSC is transported, is formed from a stainless steel pipe to which a stainless steel plate is welded at one end. The stainless steel inner lid is secured to a stainless steel plate, which is welded to the outer diameter of the stainless steel pipe and the inner diameter of the stainless steel pipe that forms the OP-RMSC exterior, using eight 1/2-13 UNC-2A hex bolts. The stainless steel pipe that forms the OP-RMSC exterior has a stainless steel plate welded to one end.

The cavity formed by the OP-RMSCs inner and outer stainless steel pipes and their stainless steel end plates is filled with polyurethane foam. The OP-RMSC lid is a stainless steel plate that is attached to a stainless steel plate welded to the inner diameter of the pipe that forms the OP-RMSC exterior, using eight 1/2-13 UNC-2A hex bolts. The maximum gross weight of the package is 650 pounds.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9387 0

71-9387 USA/9387/B(U)-96 2

OF 3

(3)

Drawings The package is constructed and assembled in accordance with the following Industrial Nuclear Company (now INC) Drawing Nos.:

OP-RMSC-SAR-TA, sheets 1-4, Rev. 1 RMSC-SAR-TA, sheets 1-3, Rev. 2 RMSC-SPFH-SAR, sheet 1, Rev. 0

5. (b)

Contents (1)

Type and form of material Iridium-192 as sealed sources that meet the requirements of special form radioactive material.

Selenium-75 as sealed sources that meet the requirements of special form radioactive material.

(2)

Maximum quantity of material per package Iridium-192:

16,000 Ci (592 TBq) (content); per capsule: 4,000 Ci (148 TBq) (content)

Selenium-75:

16,000 Ci (592 TBq) (content); per capsule 4,000 Ci (148 TBq) (content)

(3)

Maximum decay heat:

100 Watts

6.

The name plate on the overpack must be fabricated of materials capable of resisting a 1475°F fire environment for one-half hour and maintain its legibility.

7.

In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)

The package shall be prepared for shipment in accordance with the Operating Procedures in Chapter 7 of the application and (b)

The packaging must meet the Acceptance Tests and Maintenance Program in Chapter 8 of the application.

8 The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9387 0

71-9387 USA/9387/B(U)-96 3

OF 3

9.

Expiration date: January 18, 2027.

REFERENCES Industrial Nuclear Company application dated November 1, 2021.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Yoira Diaz Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Date: January 18, 2022 Yoira K. Diaz-Sanabria Digitally signed by Yoira K. Diaz-Sanabria Date: 2022.01.18 17:56:09 -05'00'