Ctr 2008/10, Revision 8, Safety Analysis Report for Packaging Safkeg-LS Design No. 3979A
ML21326A261
Person / Time
Site: 07109337
Issue date: 11/22/2021
From:
Croft Associates Limited
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML21326A259 List:
References
CTR 2008/10, Rev 8
Download: ML21326A261 (12)


Text

Safety Analysis Report for Packaging Safkeg-LS Design No. 3979A Package Docket No. 07109337 Application for Approval by the NRC Applicant: Croft Associates Limited

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-1 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 CONTENTS Chapter 0 SARP STATUS AND CONTENTS........................................................................... 0-1 0.1 SARP REVISION STATUS.................................................................................................. 0-2 0.2 PAGE AND SUPPORTING DOCUMENT REVISION STATUS...................................... 0-3 Chapter 0 SARP STATUS AND CONTENTS This Safety Analysis Report for Packaging (SARP) has been prepared by Croft Associates Ltd for the new approval of the SAFKEG-LS Design No. 3979A transport package as a Type B(U) design.

This section (Section 0) defines the document status and lists the contents of the SARP (SARP sections and appended documents included in the SARP).

This SARP is a controlled document under the Croft Associates Ltd Quality Assurance Program approved by the NRC under Approval Number 71-0939.

Revisions are on a page control basis, with revisions indicated by a vertical change bar in the right hand margin.

Reference documents, which are listed in the Appendices to each section, are those available in the general literature and are not provided in the SARP.

Supporting documents are those developed specifically for the SARP and are provided in the section that is most closely associated with the document. These supporting documents are listed in this section, together with their revision status.

Document control for the supporting documents, which have been produced by different organizations at different times with different styles, is established by reference designations and issue status and/or date: there is no significance in the various policies of adding the names of author, checker or approver or whether they are manually or electronically signed.

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-2 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 0.1 SARP REVISION STATUS Title SAFKEG-LS 3979A Docket No. 07109337 Number CTR 2008/10 Issue Revision 8 File Reference

[CTR2008-10-R8-Sc0-v3-Status and Contents.docx]

Compiled Checked A L Ferguson M B Johnson Approved Date 19 November 2021 A L Ferguson Croft Associates Ltd F4 Culham Science Centre Abingdon Oxon OX14 3DB UK Tel 44 (0)1865 407740

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-3 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 0.2 PAGE AND SUPPORTING DOCUMENT REVISION STATUS Page/Document Reference Issue Status Title/Comments Section 0 - Page and Supporting Document Revision Status Page 0-1 to 11 Rev 8 Section 1 - GENERAL INFORMATION Page 1-1 Rev 6 Page 1-2 Rev 4 Page 1-3 Rev 4 Page 1-4 Rev 4 Page 1-5 Rev 4 Page 1-6 Rev 4 Page 1-7 Rev 4 Page 1-8 Rev 4 Page 1-9 Rev 4 Page 1-10 Rev 4 Page 1-11 Rev 4 Page 1-12 Rev 4 Page 1-13 Rev 4 Page 1-14 Rev 4 Page 1-15 Rev 4 Page 1-16 Rev 4 Page 1-17 Rev 4 Page 1-18 Rev 4 Page 1-19 Rev 4 Page 1-20 Rev 4 Page 1-21 Rev 4 Page 1-22 Rev 4

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-4 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Page 1-23 Rev 4 Page 1-24 Rev 4 Page 1-25 Rev 4 Page 1-26 Rev 4 Page 1-27 Rev 5 Page 1-28 Rev 4 Page 1-29 Rev 4 Page 1-30 Rev 4 Page 1-31 Rev 4 Page 1-32 Rev 4 Page 1-33 Rev 4 Page 1-34 Rev 4 Page 1-35 Rev 4 Page 1-36 Rev 4 Page 1-37 Rev 4 Page 1-38 Rev 4 Page 1-39 Rev 4 Documents in Section 1.3 Appendix Documents in Section 1.3.2 Calculation Model Drawings 0C-6049 Issue A Safkeg-LS Construction 1C-6097 Issue A Containment Vessel LS Lid Construction 1C-6099 Issue A Containment Vessel LS Body Construction Documents in Section 1.3.3 Licensing Drawings

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-5 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments 1C-6040 Issue H Cover sheet for Safkeg-LS design no. 3979A (licensing drawing) 0C-6041 Issue C Safkeg-LS design no. 3979A (licensing drawing) 0C-6042 Issue F Keg design no. 3979 (licensing drawing) 0C-6043 Issue C Cork set for Safkeg-LS (licensing drawing) 1C-6044 Issue F Containment vessel design no. 3980 (licensing drawing) 1C-6045 Issue E Containment vessel lid (licensing drawing) 1C-6046 Issue E Containment vessel body (licensing drawing) 2C-6171 Issue C LS-12x65-Tu insert design no. 3984 (licensing drawing) 2C-6172 Issue C LS-31x73-Tu insert design no. 3983 (licensing drawing) 2C-6175 Issue D LS-50x103-SS insert design no. 3986 (licensing drawing)

Documents in Section 1.3.4 Supporting Documents PCS 036 Issue D Package Contents Specification for Safkeg-LS -

Package Design No 3979A Section 2 - STRUCTURAL EVALUATION Page 2-1 Rev 4 Page 2-2 Rev 4 Page 2-3 Rev 7 Page 2-3a Rev 7 Page 2-4 Rev 4 Page 2-5 Rev 4

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-6 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Page 2-6 Rev 4 Page 2-7 Rev 4 Page 2-8 Rev 4 Page 2-9 Rev 4 Page 2-10 Rev 4 Page 2-11 Rev 4 Page 2-12 Rev 4 Page 2-13 Rev 4 Page 2-14 Rev 4 Page 2-15 Rev 4 Page 2-16 Rev 4 Page 2-17 Rev 4 Page 2-18 Rev 4 Page 2-19 Rev 7 Page 2-20 Rev 4 Page 2-21 Rev 4 Page 2-22 Rev 4 Page 2-23 Rev 4 Page 2-24 Rev 5 Page 2-25 Rev 4 Page 2-26 Rev 4 Page 2-27 Rev 4 Page 2-28 Rev 4 Page 2-29 Rev 4 Page 2-30 Rev 4 Page 2-31 Rev 4 Page 2-32 Rev 4 Page 2-33 Rev 4

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-7 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Page 2-34 Rev 4 Page 2-35 Rev 4 Page 2-36 Rev 4 Page 2-37 Rev 4 Page 2-38 Rev 4 Page 2-39 Rev 7 Page 2-40 Rev 4 Page 2-41 Rev 4 Page 2-42 Rev 4 Page 2-43 Rev 4 Page 2-44 Rev 4 Page 2-45 Rev 4 Page 2-46 Rev 4 Page 2-47 Rev 4 Page 2-48 Rev 4 Page 2-49 Rev 4 Page 2-50 Rev 4 Page 2-51 Rev 4 Page 2-52 Rev 4 Page 2-53 Rev 7 Page 2-54 Rev 4 Page 2-55 Rev 4 Page 2-56 Rev 4 Page 2-57 Rev 4 Page 2-58 Rev 4 Page 2-59 Rev 4 Page 2-60 Rev 4 Page 2-61 Rev 4

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-8 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Page 2-62 Rev 4 Page 2-63 Rev 7 Page 2-63a Rev 7 Page 2-64 Rev 4 Page 2-65 Rev 7 Page 2-66 Rev 7 Documents in Section 2.12.2, Appendix CTR 2009/21 Issue D Prototype Safkeg-LS 3979A/0002 NCT and HAC Regulatory Test Report CTR 2009/27 Issue A Prototype SAFKEG LS 3979A/0002 NCT and HAC Regulatory Test Report SERCO/TAS/002762/01 Issue 1 Compression Testing of Cork Vectra, 925-3272/R1 Rev 6 Stress Analysis of Safkeg LS 3979A Containment Vessel CS 2009/08 Issue A SAFKEG LS 3979A - Maximum Pressure in CV CS 2010/11 Issue B Calculation of the Density of the 3977A Package Vectra, 925-3274/R1 Rev 1 Safkeg LS 3979A - Additional HAC Case Vectra, 925-3272/M2 15/03/10 Safkeg LS 3979A - Mesh Sensitivity Analysis Section 3 - THERMAL EVALUATION Page 3-1 to 3-29 Rev 8 Rev 8 Changes:

Entire section raised to Rev 8, pages renumbered.

Section 3.2.2, page 3-11: 1st paragraph changed to reduce NCT test temperature from 150oC to 130oC Note (second paragraph, added.

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-9 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Section 3.5.2, page 3-30: CTR 2021/22 and CTR 2021/24 added.

Documents in Section 3.5.2, Appendix SERCO/TAS/5388/001 Issue 2 Thermal Analysis of the Safkeg LS Design SERCO CJF10302 31 Mar 10 Response to comments on thermal performance of SAFKEG LS raised by NRC assessor CS 2010/16 Issue A SAFKEG LS 3979A - Maximum Temperature of CV Inserts CTR 2021/22 Issue A 3979A O-ring NCT Test Temperature Reduction -

SARP Impact Document added in Rev 8 to justify NCT seal test temperature reduction.

CTR2021/24 Issue A LS 3979A (3980) O-ring Seal Thermal Tests Document added in Rev 8 to provide test evidence for NCT seal test temperature reduction.

Section 4 - CONTAINMENT Page 4-1 Rev 4 Page 4-2 Rev 4 Page 4-3 Rev 4 Page 4-4 Rev 4 Page 4-5 Rev 4 Page 4-6 Rev 4 Page 4-7 Rev 4 Page 4-8 Rev 4 Documents in Section 4.5.2, Appendix CS 2009/06 Issue A SAFKEG-LS # 3979A - CV seal leak size for leaktight condition CS 2009/07 Issue B SAFKEG-LS 3979A - Gas contents limit for leaktight condition

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-10 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Section 5 - SHIELDING EVALUATION Page 5-1 Rev 5 Page 5-2 Rev 4 Page 5-3 Rev 4 Page 5-4 Rev 6 Page 5-4a Rev 6 Page 5-5 Rev 4 Page 5-6 Rev 4 Page 5-7 Rev 4 Page 5-8 Rev 6 Page 5-9 Rev 4 Page 5-10 Rev 4 Page 5-11 Rev 4 Page 5-12 Rev 5 Page 5-12a Rev 5 Page 5-13 Rev 4 Page 5-14 Rev 6 Documents in Section 5.5.2, Appendix CTR2009/22 Issue B SAFKEG LS 3979A: Package Activity Limits Based on Shielding CTR 2015/10 Issue A Uncertainties Associated with the Proposed Shielding Calculation Method for the SAFKEG-LS 3979A Package SERCO/TAS/003191/001 Issue 1 Monte Carlo Modelling of Safkeg LS Container Section 6 - CRITICALITY EVALUATION Page 6-1 Rev 4 Page 6-2 Rev 4

SAFKEG-LS 3979A Docket No. 07109337 CTR 2008/10, Revision 8 Page 0-11 CTR2008-10-R8-Sc0-v3-Status and Contents.docx November 2021 Page/Document Reference Issue Status Title/Comments Documents in Section 6.9, Appendix None Section 7 - OPERATING PROCEDURES Page 7-1 Rev 4 Page 7-2 Rev 4 Page 7-3 Rev 4 Page 7-4 Rev 4 Page 7-5 Rev 4 Page 7-6 Rev 4 Page 7-7 Rev 4 Documents in Section 7.5, Appendix None Section 8-ACCEPTANCE TESTS AND MAINTENANCE PROGRAM Page 8-1 to 8-12 Rev 8 Rev 8 Changes:

Entire section raised to Rev 8, pages renumbered.

Section 8.1.5.2, page 8-3, 1st, 2nd and 6th paragraphs.

NCT O-ring seal test remperature reduced from 150oC to 130oC (130 to 135oC range).

Documents in Section 8.3, Appendix None

-