ML21314A580
| ML21314A580 | |
| Person / Time | |
|---|---|
| Site: | 07007004 |
| Issue date: | 11/19/2021 |
| From: | Jacob Zimmerman NRC/NMSS/DFM/FFLB |
| To: | Karen Fitch American Centrifuge Operating |
| Yawar Faraz NMSS/DFM/FFL | |
| Shared Package | |
| ML21314A577 | List: |
| References | |
| EPID L-2021-SPR-0010 | |
| Download: ML21314A580 (3) | |
Text
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION K. Wieh OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 19, 2021 Ms. Kelly L. Fitch, Regulatory Manager American Centrifuge Operating, LLC P.O. Box 628 Mail Stop 7560 3930 U.S. 23 South Piketon, OH 45661
SUBJECT:
CENTRUS ENERGY CORP. AMERICAN CENTRIFUGE OPERATING, LLC -
AUTHORITY TO TEST CLASSIFIED NETWORKS FOR THE HIGH ASSAY LOW ENRICHED URANIUM CASCADE AT THE AMERICAN CENTRIFUGE PLANT IN PIKETON, OHIO (EPID L-2021-SPR-0010)
Dear Ms. Fitch:
We have reviewed your letter dated October 27, 2021 (Agencywide Document Access and Management System [ADAMS] Accession No. ML21306A253), requesting authority to test the Distributed Control System and the Process Telephone System for the High Assay Low Enriched Uranium (HALEU) cascade at the American Centrifuge Plant in Piketon, Ohio.
An authority to test has been granted by the U.S. Nuclear Regulatory Commission (NRC)
Authorizing Official and is provided in the enclosure.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter will be available for public inspection in the NRC Public Document Room or from the Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
This document transmits an enclosure containing sensitive, unclassified information.
When separated from the enclosure, this document is decontrolled.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION K. Fitch 2
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION If you have any questions, please contact me or Mr. Yawar Faraz by telephone at 301-415-7220, or by email to Yawar.Faraz@NRC.gov.
Sincerely, Jacob I. Zimmerman, Chief Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 07007004 License No. SNM-2011
Enclosure:
Interim Authority to Operate (non-public) cc:
centrus_acp@listmgr.nrc.gov L. Cutlip, Sr. Vice President, Centrus Energy Corp.
M. Snider, Enrichment Operations Plant Manager, Centrus Energy Corp.
S. Harlow, Department of Energy J. Hutson, NRC Contractor Jacob I.
Zimmerman Digitally signed by Jacob I.
Zimmerman Date: 2021.11.19 09:53:25
-05'00'
ML21314A577 (Pkg), ML21314A580 (Ltr), ML21314A581 (Encl)
OFFICE NMSS/DFM/FFL NMSS/DFM/FFLB NSIR/DSO/ISB OCIO/GEMSD NMSS/DFM/
FFLB NAME YFaraz ELee (LRonewicz for)
DParsons GNalabandian JZimmerman DATE 11/17/2021 11/12/2021 11/18/2021 11/17/2021 11/18/2021