Text
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION Enclosure(s) transmitted herewith contain(s) SUNSI. When separated from enclosure(s), this transmittal document is decontrolled.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION November 5, 2021 Mr. Mike Annacone Vice President, Columbia Fuel Operations and Manager, Columbia Plant Westinghouse Electric Company 5801 Bluff Road Hopkins, SC 29061
SUBJECT:
COLUMBIA FUEL FABRICATION FACILITY - MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT 07001151/2021401
Dear Mr. Annacone:
On October 21, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Columbia Fuel Fabrication Facility and discussed the results of this inspection with Ms. A.
Pope and other members of your staff. The results of this inspection are documented in the enclosed report.
No violations of more than minor significance were identified during this inspection.
This letter will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
The enclosed report contains Security-Related Information, so the enclosed report will not be made publicly available in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390(d)(1). If you choose to provide a response that contains Security-Related Information, please mark your entire response Security-Related Information-Withhold from public disclosure under 10 CFR 2.390 in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). The NRC is waiving the affidavit requirements for your response in accordance with 10 CFR 2.390(b)(1)(ii).
Sincerely,
/RA/
Eric C. Michel, Chief Projects Branch 2 Division of Fuel Facility Inspection
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION M. Annacone 2
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION Docket No. 07001151 License No. SNM-1107
Enclosure:
As stated cc w/o encl: Distribution via LISTSERV
ML21313A009 (Cover letter)
Cover Letter Only:
x SUNSI Review x Non-Sensitive Sensitive x Publicly Available Non-Publicly Available OFFICE RII/DFFI RII/DRS RII/DFFI RII/DFFI NAME M. Romano K. Kirchbaum T. Vukovinsky E. Michel DATE 10/28/2021 10/29/2021 10/29/2021 10/29/2021