Advanced Reactor Program - Summary of Integrated Schedule and Regulatory Activities*
Strategy 1 Knowledge, Skills, and Capability Legend Strategy 2 Computer Codes and Review Tools Concurrence (Division/Interoffice) EDO Concurrence Period Strategy 3 Guidance Federal Register Publication Commission Review Period**
Strategy 4 Consensus Codes and Standards Public Comment Period ACRS SC/FC (Scheduled or Planned)
Strategy 5 Policy and Key Technical Issues Draft Issuance of Deliverable External Stakeholder Interactions Strategy 6 Communication Final Issuance of Deliverable Public Meeting (Scheduled or Planned) Version Present Day 11/4/21 2021 2022 Commission Strategy Guidance Rulemaking Complete NEIMA Regulatory Activity Jan Feb Mar Apr May Jun Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Aug Sep Oct Nov Dec Papers Jul Jul Development of non-Light Water Reactor (LWR) Training for Advanced x
Reactors (Adv. Rxs) (NEIMA Section 103(a)(5))
FAST Reactor Technology x x 1
High Temperature Gas-cooled Reactor (HTGR) Technology x x Molten Salt Reactor (MSR) Technology x x Competency Modeling to ensure adequate workforce skillset x Identification and Assessment of Available Codes x Development of Non-LWR Computer Models and Analytical Tools Code Assessment Reports Volume 1 (Systems Analysis) x Reference plant model for Heat Pipe-Cooled Micro x
Reactor Reference plant model for Sodium-Cooled Fast Reactor x Reference plant model for Molten-Salt-Cooled Pebble Bed x
Reactor Reference plant model for Monolith-type Micro-Reactor Reference plant model for Gas-Cooled Pebble Bed Reactor Code Assessment Reports Volume 2 (Fuel Perf. Anaylsis) x FAST code assessment for metallic fuel x FAST code assessment for TRISO fuel x Code Assessment Reports Volume 3 (Source Term Analysis) x Non-LWR MELCOR (Source Term) Demonstration Project x Reference SCALE/MELCOR plant model for Heat Pipe-x Cooled Micro Reactor Reference SCALE/MELCOR plant model for High-2 x Temperature Gas-Cooled Reactor Reference SCALE/MELCOR plant model for Molten x
Salt Cooled Pebble Bed Reactor Reference SCALE/MELCOR plant model for Sodium-Cooled Fast Reactor Reference SCALE/MELCOR plant model for Molten Salt Fueled Reactor MACCS radionuclide screening analysis MACCS near-field atmospheric transport and dispersion x
model assessment MACCS radionuclide properties on atmospheric transport and dosimetry MACCS near-field atmospheric transport and dispersion x
model improvement Code Assessment Report Volume 4 (Licensing and Siting Dose Assessments)
Phase 1 - Atmospheric Code Consolidation Code Assessment Report Volume 5 (Fuel Cycle Analysis) x Research plan and accomplishments in Materials, Chemistry, and x
Component Integrity for Adv. Rxs.
Research on risk-informed and performance-based (RIPB) seismic design approaches and adopting seismic isolation technologies
Advanced Reactor Program - Summary of Integrated Schedule and Regulatory Activities*
Strategy 1 Knowledge, Skills, and Capability Legend Strategy 2 Computer Codes and Review Tools Concurrence (Division/Interoffice) EDO Concurrence Period Strategy 3 Guidance Federal Register Publication Commission Review Period**
Strategy 4 Consensus Codes and Standards Public Comment Period ACRS SC/FC (Scheduled or Planned)
Strategy 5 Policy and Key Technical Issues Draft Issuance of Deliverable External Stakeholder Interactions Strategy 6 Communication Final Issuance of Deliverable Public Meeting (Scheduled or Planned) Version Present Day 11/4/21 2021 2022 Commission Strategy Guidance Rulemaking Complete NEIMA Regulatory Activity Jan Feb Mar Apr May Jun Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Aug Sep Oct Nov Dec Papers Jul Jul Develop Regulatory Roadmap for Adv. Rxs x x (NEIMA Section 103(a)(1))
Develop prototype guidance for Adv. Rxs x Develop non-LWR Design Crtieria for Adv. Rxs x EPRI Topical Report on Tri-structural Isotropic (TRISO) Fuel x x Quality Assurance Program Plan for Sodium-cooled FAST Reactor x
Metallic Fuel Data Qualification Develop Fuel Qualification Guidance for Adv. Rxs (NUREG-2246) x x Develop Advanced Reactor Content of Application Project (ARCAP) x Regulatory Guidance Develop Advanced Reactor Technology Inclusive Content of Application x
Project (TICAP) Regulatory Guidance Develop non-LWR Construction Permit Guidance Develop non-LWR Design Review Guide (DRG) for Instrumentation and x x Controls reviews Develop Advanced Reactor Inspection and Oversight Framework x
Document Develop Environmental ISG for Micro Reactors x x Develop Regulatory Guide for Licensing Modernization Project x x Develop non-LWR Source Term Information x x x (NEIMA Section 103(c)(4)(II)
Develop Molten Salt Reactor fuel qualification guidance Interim MSR fuel qualification guidance x Final MSR fuel qualification guidance 3
Develop guidance for Non-power Liquid Fueled Molten Salt Reactors x x x (NEIMA Section 103(a)(3))
Review of non-LWR Fuel Cycle Assessment of Regulatory Infrastructure.
Develop Report on possible Material Control and Accounting x
Approaches for a Pebble Bed Reactor.
Develop Metal Fuel Fabrication Safety and Hazards Final Report x Develop Review of Hazards for Molten Salt Reactor Fuel Processing Operations x Review of Operating Experience for Transportation of Fresh (Unirradiated) Advanced Reactor Fuel Types x
Potential Challenges with Transportation of Fresh (Unirradiated)
Advanced Reactor Fuel Types x
Storage Experience with Spent (Irradiated) Advanced Reactor Fuel Types x Potential Challenges with Storage of Spent (Irradiated) Advanced x
Reactor Fuel Types Transportation Experience and Potential Challenges with x
Transportation of Spent (Irradiated) Adv. Rx Fuel Types Disposal Options and Potential Challenges to Waste Packages and Waste Forms in Disposal of Spent (Irradiated) Advanced Reactor x Information Gaps and Potential Information Needs Associated with x
Transportation of Fresh (Unirradiated) Adv. Rx Fuel Types `
Develop MC&A guidance for Cat II facilities (NUREG-2159)
Develop contractor report on technology-inclusive human factors x
engineering reviews
Advanced Reactor Program - Summary of Integrated Schedule and Regulatory Activities*
Strategy 1 Knowledge, Skills, and Capability Legend Strategy 2 Computer Codes and Review Tools Concurrence (Division/Interoffice) EDO Concurrence Period Strategy 3 Guidance Federal Register Publication Commission Review Period**
Strategy 4 Consensus Codes and Standards Public Comment Period ACRS SC/FC (Scheduled or Planned)
Strategy 5 Policy and Key Technical Issues Draft Issuance of Deliverable External Stakeholder Interactions Strategy 6 Communication Final Issuance of Deliverable Public Meeting (Scheduled or Planned) Version Present Day 11/4/21 2021 2022 Commission Strategy Guidance Rulemaking Complete NEIMA Regulatory Activity Jan Feb Mar Apr May Jun Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Aug Sep Oct Nov Dec Papers Jul Jul Develop Regulatory Guide for endorsement of the non-LWR Probabilistic x
Risk Assessment Standard Develop Regulatory Guide for endorsement of the ASME Section III, x
Division 5 Standard 4
Alloy 617 Code Cases (N-872 and N-898)
Develop Draft Guide endorsing ASME Section XI Division 2 Reliability and Integrity Management (RIM)
Develop SECY paper related to Consequence Based Security (SECY x 0076)
Develop SECY paper related to EP for Small Modular Reactors and x x Other New Technologies (SECY-18-0103)
Develop SECY paper related to Functional Containment x x (SECY-18-0096)
SECY-20-0093 Policy and Licensing Considerations related to Micro 5 x x Reactors Report regarding review of the insurance and liability for advanced x
reactors (Price-Anderson Act)
Annual Fees for Non-Light Water Reactors and Microreactors Develop SECY Paper regarding Population-Related Siting x
Considerations for Advanced Reactors Develop annual SECY paper regarding status of non-LWR activities x 6
NRC DOE Workshops x Part 53 Plan - Risk-Informed, Technology Inclusive Regulatory x x Framework for Advanced Reactors (NEIMA Section 103(a)(4))
Public Meetings Rulemaking ACRS Interactions Physical Security for Advanced Reactors x Develop draft Generic Environmental Impact Statement for Advanced Reactors. Final GEIS.*(Has been voted to rulemaking by Comm.)
Emergency Preparedness Requirements for Small Modular Reactors x x and Other New Technologies.(NEIMA Section 103(a)(2))
x x
- Dates reflected above are best estimates. Actual dates will be updated as additional information becomes available.
- The timeframe for the Commissions review is for planning purposes only, and does not reflect an expected date for Commission decision.