Core Operating Limits Report - Cycle 26
ML21300A039
Person / Time
Site: Salem PSEG icon.png
Issue date: 10/26/2021
From: Jennings J
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LR-N21-0077
Download: ML21300A039 (16)


Text

PSEG uclear LLC P.O. Box 236. Hancooks Bridge, NJ 08038-0236 u aa-25. 202

-;n;ry Commission

=*,t,G.. u Control Desk

. g:oo DC 20555-0001 Sa?em Gen srafing, Station Unit 2 Re; ?1,-'erl Facility Operating License DPR-75 RC Dod~ No. ~311 Technical Specification 6.9.1.9 Salem Urut 2 Core Operating Limits Report - Cycle 26 In accoidance vm:h section 6.9.1.9 of the Salem Unit 2 Technical Specifications, PSEG f<ludear~ LLC submits the enclosed Core Operating Limits Report (COLR) for Salem Unit 2, 0Jde 26.

There are no commitments contained in this letter.

Pfease contact Mr. Harry Balian at (856) 339 - 2173 if you have any questions.

Since,refy, jl Jason Jennings Director, Site Regulatory Compliance PSEG Nudear, LLC

October 26, 2021 Technical Specification 6.9.1.9 Page 2 LR-N21-0077 cc:

USNRC Regional Administrator Region 1 USNRC NRR Project Manager Salem USNRC Senior Resident Inspector - Salem NJ Department of Environmental Protection, Bureau of Nuclear Engineering President & Chief Nuclear Officer Site Vice President - Salem Plant Manager - Salem Senior Director, Regulatory Operations & Nuclear Oversight Manager - Nuclear Oversight Director - Regulatory Affairs Manager - Licensing Corporate Commitment Coordinator, PSEG Nuclear, LLC Records Management

LR-N21-0077 Enclosure Salem Unit 2 Core Operating Limits Report (COLR)

Cycle 26

Page 1 of 13 COLR SALEM 2 Revision 10 July 2021 Core Operating Limits Report for Salem Unit 2, Cycle 26

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 2 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 TABLE OF CONTENTS Section Number Section Title Page Number Table of Contents 2

List of Figures 3

1.0 Core Operating Limits Report 4

2.0 Operating Limits 5

2.1 Moderator Temperature Coefficient (Specification 3.1.1.3) 5 2.2 Control Rod Insertion Limits (Specification 3.1.3.5) 6 2.3 Axial Flux Difference (Specification 3.2.1) 6 2.4 Heat Flux Hot Channel Factor - FQ(z) (Specification 3.2.2) 6 2.5 Nuclear Enthalpy Rise Hot Channel Factor - FNH (Specification 3.2.3) 8 2.6 Boron Concentration (Specification 3.9.1) 9 3.0 Analytical Methods 9

4.0 References 10

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 3 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 LIST OF FIGURES Figure Number Figure Title Page Number 1

Rod Bank Insertion Limits vs. Thermal Power 11 2

Axial Flux Difference Limits as a Function of Rated Thermal Power 12 3

K(z) - Normalized FQ(z) as a Function of Core Height 13

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 4 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for Salem Unit 2 Cycle 26 has been prepared in accordance with the requirements of Technical Specification 6.9.1.9. The Technical Specifications affected by this report are listed below along with the NRC-approved methodologies used to develop and/or determine COLR parameters identified in Technical Specifications.

TS Section Technical Specifications COLR Parameter COLR Section NRC Approved Methodology (Section 3.0 Number) 3.1.1.3 Moderator Temperature Coefficient MTC 2.1 3.1, 3.6 3.1.3.5 Control Rod Insertion Limits Control Rod Insertion Limits 2.2 3.1, 3.6 3.2.1 Axial Flux Difference AFD 2.3 3.1, 3.2, 3.6 3.2.2 Heat Flux Hot Channel Factor -

FQ(z)

FQ(z) 2.4 3.1, 3.3, 3.4, 3.5, 3.6, 3.7, 3.8, 3.9 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor - FNH FNH 2.5 3.1, 3.5, 3.6, 3.8, 3.9 3.9.1 Boron Concentration Boron Concentration 2.6 3.1, 3.6

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 5 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections. These limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.9 and in Section 3.0 of this report.

2.1 Moderator Temperature Coefficient (Specification 3.1.1.3) 2.1.1 The Moderator Temperature Coefficient (MTC) limits are:

The BOL/ARO/HZP-MTC shall be less positive than or equal to 0 k/k/°F.

The EOL/ARO/RTP-MTC shall be less negative than or equal to -4.4x10-4 k/k/°F.

2.1.2 The MTC Surveillance limit is:

The 300 ppm/ARO/RTP-MTC should be less negative than or equal to -3.7x10-4 k/k/°F.

where: BOL stands for Beginning of Cycle Life ARO stands for All Rods Out HZP stands for Hot Zero THERMAL POWER EOL stands for End of Cycle Life RTP stands for RATED THERMAL POWER

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 6 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 2.2 Control Rod Insertion Limits (Specification 3.1.3.5) 2.2.1 The control rod banks shall be limited in physical insertion as shown in Figure 1.

2.3 Axial Flux Difference (Specification 3.2.1)

[Constant Axial Offset Control (CAOC) Methodology]

2.3.1 The Axial Flux Difference (AFD) target band shall be (+6%, -9%).

2.3.2 The AFD Acceptable Operation Limits are provided in Figure 2.

2.4 Heat Flux Hot Channel Factor - FQ(z) (Specification 3.2.2)

[Fxy Methodology]

FQ(z) FQRTP P

  • K(z) for P > 0.5 FQ(z) FQRTP 0.5
  • K(z) for P 0.5 where: P =

THERMAL POWER RATED THERMAL POWER 2.4.1 FQRTP = 2.40 2.4.2 K(z) is provided in Figure 3.

2.4.3 FxyL = FxyRTP [1.0 + PFxy (1.0 - P)]

where: from BOL to 10000 MWD/MTU FxyRTP =

2.03 for unrodded upper core planes 1 through 6 1.97 for unrodded upper core planes 7 through 8 1.81 for unrodded upper core planes 9 through 11 1.76 for unrodded upper core planes 12 through 13 1.76 for unrodded upper core planes 14 through 18 1.79 for unrodded upper core planes 19 through 31 1.81 for unrodded lower core planes 32 through 43 1.85 for unrodded lower core planes 44 through 48 1.93 for unrodded lower core planes 49 through 50 1.90 for unrodded lower core planes 51 through 53

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 7 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 2.00 for unrodded lower core planes 54 through 55 2.03 for unrodded lower core planes 56 through 61 2.07 for the core planes containing Bank D control rods PFxy =

0.3 where

from 10000 MWD/MTU to 14000 MWD/MTU FxyRTP =

2.03 for unrodded upper core planes 1 through 6 1.89 for unrodded upper core planes 7 through 8 1.80 for unrodded upper core planes 9 through 11 1.76 for unrodded upper core planes 12 through 13 1.76 for unrodded upper core planes 14 through 18 1.87 for unrodded upper core planes 19 through 31 1.92 for unrodded lower core planes 32 through 43 1.87 for unrodded lower core planes 44 through 48 1.89 for unrodded lower core planes 49 through 50 1.84 for unrodded lower core planes 51 through 53 1.90 for unrodded lower core planes 54 through 55 2.03 for unrodded lower core planes 56 through 61 2.07 for the core planes containing Bank D control rods PFxy =

0.3 where

from 14000 MWD/MTU to EOL FxyRTP =

2.03 for unrodded upper core planes 1 through 6 1.89 for unrodded upper core planes 7 through 8 1.81 for unrodded upper core planes 9 through 11 1.80 for unrodded upper core planes 12 through 13 1.82 for unrodded upper core planes 14 through 18 1.99 for unrodded upper core planes 19 through 31 1.98 for unrodded lower core planes 32 through 43 1.86 for unrodded lower core planes 44 through 48 1.88 for unrodded lower core planes 49 through 50 1.82 for unrodded lower core planes 51 through 53 1.84 for unrodded lower core planes 54 through 55 2.01 for unrodded lower core planes 56 through 61 2.07 for the core planes containing Bank D control rods PFxy =

0.3

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 8 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 2.4.4 If the Power Distribution Monitoring System (PDMS) is used for core power distribution surveillance and is OPERABLE, as defined in Technical Specification 3.3.3.14, the uncertainty, UFQ, to be applied to the Heat Flux Hot Channel Factor FQ(z) shall be calculated by the following formula:

U U

U FQ Q

e

=

+

10 100 0 where:

UQ = Uncertainty for power peaking factor as defined in equation 5-19 of Analytical Method 3.5.

Ue = Engineering uncertainty factor.

= 1.03 Note: UFQ= PDMS Surveillance Report Core Monitor Fxy Uncertainty in %.

2.4.5 If the INCORE movable detectors are used for core power distribution surveillance, the uncertainty, UFQ, to be applied to the Heat Flux Hot Channel Factor FQ(z) shall be calculated by the following formula:

U U

U FQ qu e

=

where:

Uqu = Base FQ measurement uncertainty.

= 1.05 Ue = Engineering uncertainty factor.

= 1.03 2.5 Nuclear Enthalpy Rise Hot Channel Factor - FNH (Specification 3.2.3)

FNH = FRTPH [1.0 + PFH (1.0 - P)]

where: P =

THERMAL POWER RATED THERMAL POWER 2.5.1 FRTPH = 1.65 2.5.2 PFH = 0.3 2.5.3 If the Power Distribution Monitoring System (PDMS) is used for core power distribution surveillance and is OPERABLE, as defined in Technical Specification 3.3.3.14, the uncertainty, UFH, to be applied to the Nuclear Enthalpy Rise Hot Channel Factor, FNH, shall be the greater of 1.04 or as calculated by the following formula:

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 9 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 0.

100 0.1 H

H F

U U

+

=

where: UH = Uncertainty for enthalpy rise hot channel factor as defined in equation 5-19 of Analytical Method 3.5.

2.5.4 If the INCORE movable detectors are used for core power distribution surveillance, the uncertainty, UFH, to be applied to the Nuclear Enthalpy Rise Hot Channel Factor FNH shall be calculated by the following formula:

Hm F

H F

U U

=

where: UFHm = Base FH measurement uncertainty.

= 1.04 2.6 Boron Concentration (Specification 3.9.1)

A Mode 6 boron concentration, maintained at or above 2050 ppm, in the Reactor Coolant System, the fuel storage pool, the refueling canal, and the refueling cavity ensures the most restrictive of the following reactivity conditions is met:

a) A K-effective (Keff) of 0.95 or less at All Rods In (ARI), Cold Zero Power (CZP) conditions with a 1% k/k uncertainty added.

b) A Keff of 0.99 or less at All Rods Out (ARO), CZP conditions with a 1% k/k uncertainty added.

c) A boron concentration of greater than or equal to 2000 ppm, which includes a 50 ppm conservative allowance for uncertainties.

3.0 ANALYTICAL METHODS The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents.

3.1 WCAP-9272-P-A, Westinghouse Reload Safety Evaluation Methodology, July 1985 (Westinghouse proprietary). Methodology for Specifications listed in 6.9.1.9.a. Approved by Safety Evaluation dated May 28, 1985.

3.2 WCAP-8385, Power Distribution Control and Load Following Procedures - Topical Report, September 1974 (Westinghouse proprietary). Methodology for Specification 3/4.2.1 Axial Flux Difference. Approved by Safety Evaluation dated January 31, 1978.

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 10 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 3.3 WCAP-10054-P-A, Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code, August 1985 (Westinghouse proprietary). Methodology for Specification 3/4.2.2 Heat Flux Hot Channel Factor. Approved for Salem by NRC letter dated August 25, 1993.

3.4 WCAP-10266-P-A, Revision 2, The 1981 Version of the Westinghouse ECCS Evaluation Model Using the BASH Code, March 1987 (Westinghouse proprietary). Methodology for Specification 3/4.2.2 Heat Flux Hot Channel Factor. Approved by Safety Evaluation dated November 13, 1986.

3.5 WCAP-12472-P-A, BEACON - Core Monitoring and Operations Support System, August 1994 (Westinghouse proprietary). Approved by Safety Evaluation dated February 16, 1994.

3.6 CENPD-397-P-A, Revision 01, Improved Flow Measurement Accuracy Using Crossflow Ultrasonic Flow Measurement Technology, May 2000. Approved by Safety Evaluation dated March 20, 2000.

3.7 WCAP-10054-P-A, Addendum 2, Revision 1, Addendum to the Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code: Safety Injection into the Broken Loop and COSI Condensation Model, July 1997 (Westinghouse proprietary). Approved by Safety Evaluation dated August 12, 1996.

3.8 WCAP-12472-P-A, Addendum 1-A, BEACON Core Monitoring and Operations Support System, January 2000 (Westinghouse proprietary). Approved by Safety Evaluation dated September 30, 1999.

3.9 WCAP-12472-P-A, Addendum 4, BEACON Core Monitoring and Operation Support System, Addendum 4, September 2012 (Westinghouse proprietary). Approved by Safety Evaluation dated August 9, 2012.

4.0 REFERENCES

1. Salem Nuclear Generating Station Unit No. 2, up to Amendment No. 316, Renewed License No. DPR-75, Docket No. 50-311.
      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 11 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 FIGURE 1 ROD BANK INSERTION LIMITS VS. THERMAL POWER 0

20 40 60 80 100 120 140 160 180 200 220 240 0

20 40 60 80 100 CONTROL BANK POSITION (Steps Withdrawn)

PERCENT OF RATED THERMAL POWER (%)

BANK B BANK C BANK D 17.9, 229 0, 186 71.2, 229 0, 58 100, 170 29, 0

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 12 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 FIGURE 2 AXIAL FLUX DIFFERENCE LIMITS AS A FUNCTION OF RATED THERMAL POWER

-50

-40

-30

-20

-10 0

10 20 30 40 50 Flux Difference (% Delta I) 0 20 40 60 80 100 Percent of Rated Thermal Power (%)

(-11,90)

(11,90)

(-31,50)

(31,50)

ACCEPTABLE OPERATION UNACCEPTABLE OPERATION UNACCEPTABLE OPERATION

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)

COLR SALEM 2 PSEG Nuclear LLC Page 13 of 13 Revision 10 SALEM UNIT 2 CYCLE 26 COLR July 2021 FIGURE 3 K(z) - NORMALIZED FQ(z) AS A FUNCTION OF CORE HEIGHT 0

2 4

6 8

10 12 CORE HEIGHT (FEET) 0.0 0.2 0.4 0.6 0.8 1.0 1.2 NORMALIZED PEAKING FACTOR K(Z)

FQ K(Z) Height (FT) 2.40 1.0 0.0 2.40 1.0 6.0 2.22 0.925 12.0

      • This record was final approved on 7/9/2021 12:11:26 PM. (This statement was added by the PRIME system upon its validation)