ML21273A154

From kanterella
Jump to navigation Jump to search

2. CoC No. 9036, Rev 14
ML21273A154
Person / Time
Site: 07109036
Issue date: 10/01/2021
From: John Mckirgan
Storage and Transportation Licensing Branch
To:
Source Production & Equipment Co
Bernie White NMSS/DFM/STL 301-415-6577
Shared Package
ML21273A124 List:
References
CoC No. 9036, EPID L-2021-RNW-0010
Download: ML21273A154 (3)


Text

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9036 14 71-9036 USA/9036/B(U)-96 1

OF 3

2.

PREAMBLE

a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION

a.

ISSUED TO (Name and Address)

b. TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Source Production and Equipment Company, Inc.

113 Teal Street St. Rose, LA 70087-9691 Source Production and Equipment Company, Inc.

application dated February 28, 2001, as supplemented.

4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.
5.

(a)

Packaging (1)

Model No.: C-1 (2)

Description The packaging consists of a steel inner unit inside an outer overpack. The inner unit is a rectangular box approximately 9 high x 7.5 wide x 7.5 deep around a depleted uranium shield. All fittings and source locking components are protected and enclosed within the 1/8 carbon steel outer shell. The inner receptacle consists of a uranium shield equipped with two closed bottom Zircalloy or titanium J tubes, each of which may house one pigtail type special form source. The overpack is a 12-gallon, 20- or 22-gage steel drum partially filled with foam. The weight of the inner unit is 51 to 70 lbs. The weight of the overpack is 19 to 22 lbs. Up to 8 lbs. of ancillary equipment may be included within the overpack. The maximum gross weight of the package is 100 lbs.

(3)

Drawings The packaging is constructed in accordance with Source Production and Equipment Company, Inc., Drawing Nos. B322000, Rev. (3); B311000, Rev. (2); B311001, Rev. (1); and B311002, Rev. (0).

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9036 14 71-9036 USA/9036/B(U)-96 2

OF 3

5.(b)

Contents (1)

Type and form of material Iridium-192, Selenium-75, and Ytterbium-169 as sealed sources that meet the requirements of special form radioactive material.

(2)

Maximum quantity of material per package Two sealed sources with a combined activity not to exceed 300 curies (11.1 TBq) (output)

Output curies are determined by measuring the source output at 1 meter and expressing its activity in curies derived from the following: 0.48 R/(h-Ci) Iridium-192.

6.

Tungsten shield pads, with dimensions up to approximately 2-inches diameter and 1/2-inch thick, may be welded to the inside surface of the source changer housing.

7.

The nameplate shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.

8.

In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)

The package shall be prepared for shipment and operated in accordance with the Operating Procedures of Section 7.0 of the application, as supplemented; and (b)

The package shall meet the Acceptance Tests and be maintained in accordance with the Maintenance Program of Section 8.0 of the application, as supplemented.

9.

The packaging authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.

10.

Revision No. 13 of this certificate may be used until October 31, 2021.

11.

Expiration date: October 31, 2026.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9036 14 71-9036 USA/9036/B(U)-96 3

OF 3

REFERENCES Source Production and Equipment Company, Inc., applications dated September 27, 2000, and February 28, 2001.

Supplements dated: April 11, and May 11, 2001; May 1, June 14, and June 23, 2006; May 26, 2011; May 31, 2016; and September 28, 2021.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION John McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Date: October 1, 2021 John B.

McKirgan Digitally signed by John B.

McKirgan Date: 2021.10.01 09:38:51 -04'00'