OFFICIAL USE ONLY SECURITY-RELATED INFORMATION

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555- 0001

September 17, 2021

Ms. Kelly L. Fitch, Regulatory Manager American Centrifuge Operating, LLC P.O. Box 628 Mail Stop 7560 3930 U.S. 23 South Piketon, Ohio 45661

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - LICENSE AMENDMENT APPLICATION FOR CLASSIFIED PROCESS TELEPHONE SYSTEM SECURITY PLAN (ENTERPRISE PROJECT IDENTIFICATION NUMBER: L-2020- LLA-0041)

Dear Ms. Fitch :

By letter dated March 10, 2021 (Agencywide Documents Access and Management System

[ADAMS] Accession No. ML20108F542), American Centrifuge Operating, LLC (ACO), a wholly owned subsidiary of Centrus Energy Corp. (Centrus), submitted a request to amend its Materials License SNM-2011 for the American Centrifuge Plant in Piketon Ohio by submitting a new security plan entitled American Centrifuge Operating, LLC Classified Process Telephone System (PTS) for X-3001, X-3012, C-1107E in Piketon, Ohio (SP-3605-0044).

On August 24-25, 2021, the NRC staff conducted a walkdown of the PTS. As a result of the walkdown, we have identified technical areas where additional information is needed in order to make a determination of the adequacy of your request. The specific areas where additional information is needed are stated in the non-public enclosure to this letter.

In accordance with Title 10 of the Code of Federal Regulations, Section 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records component of the NRCs ADAMS. The ADAMS database is accessible from the NRC Web site at http://www.nrc.gov/reading -rm/adams.html.

The enclosure transmitted herewith contains sensitive non-public information. When separated from the sensitive conditions in the enclosure, this document is decontrolled.

OFFICIAL USE ONLY SECURITY-RELATED INFORMATION

OFFICIAL USE ONLY SECURITY-RELATED INFORMATION

K. Fitch 2

Please submit your response to this request for additional information (RAI) within 30 days of the date of this letter. If a clarification call on the RAIs is needed, please request a clarification call before September 20, 2021.

If you have any questions regarding this communication, please contact me by telephone at 301-415-7220, or via e-mail at Yawar.Faraz@nrc.gov.

Sincerely,

Yawar H. Faraz, Senior Project Manager Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards

Docket No. 70- 7004 License No. SNM-2011

Enclosure:

Request for Additional Information (non-public)

cc: centrus_acp@listmgr.nrc.gov L. Cutlip, Vice President, Centrus S. Harlow, DOE NE-HQ J. Hutson, DOE NE-ORSO Contract Support

OFFICIAL USE ONLY SECURITY-RELATED INFORMATION

ML21246A218 (pkg), ML21246A220 (ltr)

ML21246A219 (non-public enclosure) *via e-mail OFFICE NMSS/DFM/ NMSS/DFM/ OCIO/GEMSD/ NSIR/DSO/ OGC/GCRPS/ NMSS/DFM/

FFLB* FFLB* CSB* ISB* HLWFCNS* FFLB*

NAME YFaraz ELee GNalabandian DParsons NSt.Amour JZimmerman DATE 9/07/2021 9/08/2021 9/09/2021 9/09/2021 9/15/2021 9/16 /2021