From:

Rogers, Bill To:

Robert.Coffey@fpl.com Cc:

Clark, Phyllis; Gibson, Lauren; Elliott, Robert; Bradford, Anna; Caldwell, Bob; Young, Mitzi; Wachutka, Jeremy; Jones, Travis; Venkataraman, Booma; "Salgado, Nancy"; "Maher, William"; RidsNrrDnrl Resource; RidsNrrDnrlNlrp Resource; Burnell, Scott; Wolf, Carolyn; Franzone, Steve; Orthen, Richard; Makar, Gregory; Bloom, Steven Bcc:

Rogers, Bill

Subject:

Point Beach SLRA Draft Safety RAIs Set 4 (Draft)

Date:

Monday, August 02, 2021 2:05:00 PM Attachments:

Point Beach Subsequent License Renewal Application Draft Safety RAI Set 4.pdf Bob Coffey Executive Vice President, Nuclear and Chief Nuclear Officer Florida Power & Light Company 700 Universe Blvd Mail Stop: EX/JB Juno Beach, Florida 33408

Mr. Coffey:

By letter dated November 16, 2020 (Agencywide Documents Access and Management System (ADAMS) Package Accession No.ML20329A292), NextEra Energy Point Beach, LLC (NextEra) submitted an application for subsequent renewal of Renewed Facility Operating License Nos.DPR-24 and DPR-27 for Point Beach Nuclear Plant, Units1and2 (Point Beach), respectively, to the U.S. Nuclear Regulatory Commission (NRC).

The NRC staff in the Corrosion and Steam Generators (NCSG) branch, in the Division of New and Renewed Licenses (DNRL), is in the process of reviewing your application. Based on our review, the NRC staff has identified the attached draft request for additional information (RAI) and request for confirmation of information (RCI).

Please have your staff contact me at your earliest convenience to schedule a clarification call, if needed.

If you have any questions, please contact me by e-mail bill.rogers@nrc.gov.

Sincerely, Bill Rogers

Bill Rogers Sr. Project Manager - Point Beach SLRA (Safety)

License Renewal Projects Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation 301-415-2945 bill.rogers@nrc.gov

Docket Nos. 50-266 and 50-301

Attachment:

As stated