ML21214A083
| ML21214A083 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 07/27/2021 |
| From: | Bill Rogers NRC/NRR/DNRL/NLRP |
| To: | Coffey B Florida Power & Light Co |
| Rogers B | |
| Shared Package | |
| ML21214A082 | List: |
| References | |
| Download: ML21214A083 (2) | |
Text
From:
Rogers, Bill To:
Robert.Coffey@fpl.com Cc:
Clark, Phyllis; Rodriguez-Luccioni, Hector; Gibson, Lauren; Elliott, Robert; Bradford, Anna; Caldwell, Bob; Young, Mitzi; Wachutka, Jeremy; Jones, Travis; Venkataraman, Booma; "Maher, William"; RidsNrrDnrl Resource; RidsNrrDnrlNlrp Resource; Burnell, Scott; Wolf, Carolyn; Franzone, Steve; Rogers, Bill
Subject:
Point Beach SLRA RAIS Set 3 Final Date:
Tuesday, July 27, 2021 2:32:00 PM Attachments:
Point Beach SLRA Safety RAIs Set 3 Final.pdf Bob Coffey Executive Vice President, Nuclear and Chief Nuclear Officer Florida Power & Light Company 700 Universe Blvd Mail Stop: EX/JB Juno Beach, Florida 33408
Mr. Coffey:
By letter dated November 16, 2020 (Agencywide Documents Access and Management System (ADAMS) Package Accession No.ML20329A292), NextEra Energy Point Beach, LLC (NextEra) submitted an application for subsequent renewal of Renewed Facility Operating License Nos.DPR-24 and DPR-27 for Point Beach Nuclear Plant, Units1and2 (Point Beach), respectively, to the U.S. Nuclear Regulatory Commission (NRC).
The NRC staff in the Vessels and Internals (NVIB) branch and Piping and Head Penetrations (NPHP) branch, in the Division of New and Renewed Licenses (DNRL),
is in the process of reviewing your application. Based on our review, the NRC staff has identified the attached request for additional information (RAI) and request for confirmation of information (RCI).
These requests for additional information were discussed with Bill Maher and Steve Franzone of your staff, and a mutually agreeable date for the response is within 30 days from the date of this email.
If you have any questions, please contact Bill Rogers by e-mail bill.rogers@nrc.gov.
Sincerely, Bill
Bill Rogers Sr. Project Manager - Point Beach SLRA (Safety)
NLRP/DNRL/NRR 301-415-2945 bill.rogers@nrc.gov