ML21187A208

From kanterella
Jump to navigation Jump to search
NRCS_2021_Soil_Report
ML21187A208
Person / Time
Site: Westinghouse
Issue date: 03/09/2021
From:
US Dept of Agriculture, Natural Resources Conservation Service
To:
Office of Nuclear Material Safety and Safeguards
Trefethen, JA
References
Download: ML21187A208 (42)


Text

United States Department of Agriculture A product of the National Cooperative Soil Survey, a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local participants Custom Soil Resource Report for Richland County, South Carolina CFFF Site and Vicinity Natural Resources Conservation Service March 9, 2021

Preface Soil surveys contain information that affects land use planning in survey areas.

They highlight soil limitations that affect various land uses and provide information about the properties of the soils in the survey areas. Soil surveys are designed for many different users, including farmers, ranchers, foresters, agronomists, urban planners, community officials, engineers, developers, builders, and home buyers.

Also, conservationists, teachers, students, and specialists in recreation, waste disposal, and pollution control can use the surveys to help them understand, protect, or enhance the environment.

Various land use regulations of Federal, State, and local governments may impose special restrictions on land use or land treatment. Soil surveys identify soil properties that are used in making various land use or land treatment decisions.

The information is intended to help the land users identify and reduce the effects of soil limitations on various land uses. The landowner or user is responsible for identifying and complying with existing laws and regulations.

Although soil survey information can be used for general farm, local, and wider area planning, onsite investigation is needed to supplement this information in some cases. Examples include soil quality assessments (http://www.nrcs.usda.gov/wps/

portal/nrcs/main/soils/health/) and certain conservation and engineering applications. For more detailed information, contact your local USDA Service Center (https://offices.sc.egov.usda.gov/locator/app?agency=nrcs) or your NRCS State Soil Scientist (http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/contactus/?

cid=nrcs142p2_053951).

Great differences in soil properties can occur within short distances. Some soils are seasonally wet or subject to flooding. Some are too unstable to be used as a foundation for buildings or roads. Clayey or wet soils are poorly suited to use as septic tank absorption fields. A high water table makes a soil poorly suited to basements or underground installations.

The National Cooperative Soil Survey is a joint effort of the United States Department of Agriculture and other Federal agencies, State agencies including the Agricultural Experiment Stations, and local agencies. The Natural Resources Conservation Service (NRCS) has leadership for the Federal part of the National Cooperative Soil Survey.

Information about soils is updated periodically. Updated information is available through the NRCS Web Soil Survey, the site for official soil survey information.

The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or a part of an individual's income is derived from any public assistance program. (Not all prohibited bases apply to all programs.) Persons with disabilities who require 2

alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA's TARGET Center at (202) 720-2600 (voice and TDD). To file a complaint of discrimination, write to USDA, Director, Office of Civil Rights, 1400 Independence Avenue, S.W., Washington, D.C. 20250-9410 or call (800) 795-3272 (voice) or (202) 720-6382 (TDD). USDA is an equal opportunity provider and employer.

3

Contents Preface.................................................................................................................... 2 How Soil Surveys Are Made..................................................................................5 Soil Map.................................................................................................................. 8 Soil Map................................................................................................................9 Legend................................................................................................................10 Map Unit Legend................................................................................................ 11 Map Unit Descriptions.........................................................................................11 Richland County, South Carolina....................................................................14 CaCantey loam........................................................................................14 CdChastain silty clay loam.......................................................................15 CeChewacla loam, 0 to 2 percent slopes, frequently flooded..................16 CnClarendon sandy loam........................................................................ 17 CoCongaree loam....................................................................................18 CxCoxville fine sandy loam......................................................................19 DoBDothan loamy sand, 2 to 6 percent slopes....................................... 20 FaAFaceville sandy loam, 0 to 2 percent slopes..................................... 22 GoAGoldsboro sandy loam, 0 to 2 percent slopes.................................. 23 JoJohnston loam......................................................................................24 M-WMiscellaneous Water........................................................................25 ObAOrangeburg loamy sand, 0 to 2 percent slopes................................25 OgBOrangeburg-Urban land complex, 2 to 6 percent slopes..................26 PsPersanti very fine sandy loam............................................................. 27 SmSmithboro loam.................................................................................. 28 TcTawcaw silty clay loam.........................................................................29 ToToccoa loam.........................................................................................31 VaCVaucluse loamy sand, 6 to 10 percent slopes...................................32 WWater....................................................................................................33 Soil Information for All Uses...............................................................................34 Suitabilities and Limitations for Use....................................................................34 Land Classifications........................................................................................34 Farmland Classification...............................................................................34 References............................................................................................................41 4

How Soil Surveys Are Made Soil surveys are made to provide information about the soils and miscellaneous areas in a specific area. They include a description of the soils and miscellaneous areas and their location on the landscape and tables that show soil properties and limitations affecting various uses. Soil scientists observed the steepness, length, and shape of the slopes; the general pattern of drainage; the kinds of crops and native plants; and the kinds of bedrock. They observed and described many soil profiles. A soil profile is the sequence of natural layers, or horizons, in a soil. The profile extends from the surface down into the unconsolidated material in which the soil formed or from the surface down to bedrock. The unconsolidated material is devoid of roots and other living organisms and has not been changed by other biological activity.

Currently, soils are mapped according to the boundaries of major land resource areas (MLRAs). MLRAs are geographically associated land resource units that share common characteristics related to physiography, geology, climate, water resources, soils, biological resources, and land uses (USDA, 2006). Soil survey areas typically consist of parts of one or more MLRA.

The soils and miscellaneous areas in a survey area occur in an orderly pattern that is related to the geology, landforms, relief, climate, and natural vegetation of the area. Each kind of soil and miscellaneous area is associated with a particular kind of landform or with a segment of the landform. By observing the soils and miscellaneous areas in the survey area and relating their position to specific segments of the landform, a soil scientist develops a concept, or model, of how they were formed. Thus, during mapping, this model enables the soil scientist to predict with a considerable degree of accuracy the kind of soil or miscellaneous area at a specific location on the landscape.

Commonly, individual soils on the landscape merge into one another as their characteristics gradually change. To construct an accurate soil map, however, soil scientists must determine the boundaries between the soils. They can observe only a limited number of soil profiles. Nevertheless, these observations, supplemented by an understanding of the soil-vegetation-landscape relationship, are sufficient to verify predictions of the kinds of soil in an area and to determine the boundaries.

Soil scientists recorded the characteristics of the soil profiles that they studied. They noted soil color, texture, size and shape of soil aggregates, kind and amount of rock fragments, distribution of plant roots, reaction, and other features that enable them to identify soils. After describing the soils in the survey area and determining their properties, the soil scientists assigned the soils to taxonomic classes (units).

Taxonomic classes are concepts. Each taxonomic class has a set of soil characteristics with precisely defined limits. The classes are used as a basis for comparison to classify soils systematically. Soil taxonomy, the system of taxonomic classification used in the United States, is based mainly on the kind and character of soil properties and the arrangement of horizons within the profile. After the soil 5

scientists classified and named the soils in the survey area, they compared the individual soils with similar soils in the same taxonomic class in other areas so that they could confirm data and assemble additional data based on experience and research.

The objective of soil mapping is not to delineate pure map unit components; the objective is to separate the landscape into landforms or landform segments that have similar use and management requirements. Each map unit is defined by a unique combination of soil components and/or miscellaneous areas in predictable proportions. Some components may be highly contrasting to the other components of the map unit. The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The delineation of such landforms and landform segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, onsite investigation is needed to define and locate the soils and miscellaneous areas.

Soil scientists make many field observations in the process of producing a soil map.

The frequency of observation is dependent upon several factors, including scale of mapping, intensity of mapping, design of map units, complexity of the landscape, and experience of the soil scientist. Observations are made to test and refine the soil-landscape model and predictions and to verify the classification of the soils at specific locations. Once the soil-landscape model is refined, a significantly smaller number of measurements of individual soil properties are made and recorded.

These measurements may include field measurements, such as those for color, depth to bedrock, and texture, and laboratory measurements, such as those for content of sand, silt, clay, salt, and other components. Properties of each soil typically vary from one point to another across the landscape.

Observations for map unit components are aggregated to develop ranges of characteristics for the components. The aggregated values are presented. Direct measurements do not exist for every property presented for every map unit component. Values for some properties are estimated from combinations of other properties.

While a soil survey is in progress, samples of some of the soils in the area generally are collected for laboratory analyses and for engineering tests. Soil scientists interpret the data from these analyses and tests as well as the field-observed characteristics and the soil properties to determine the expected behavior of the soils under different uses. Interpretations for all of the soils are field tested through observation of the soils in different uses and under different levels of management.

Some interpretations are modified to fit local conditions, and some new interpretations are developed to meet local needs. Data are assembled from other sources, such as research information, production records, and field experience of specialists. For example, data on crop yields under defined levels of management are assembled from farm records and from field or plot experiments on the same kinds of soil.

Predictions about soil behavior are based not only on soil properties but also on such variables as climate and biological activity. Soil conditions are predictable over long periods of time, but they are not predictable from year to year. For example, soil scientists can predict with a fairly high degree of accuracy that a given soil will have a high water table within certain depths in most years, but they cannot predict that a high water table will always be at a specific level in the soil on a specific date.

After soil scientists located and identified the significant natural bodies of soil in the survey area, they drew the boundaries of these bodies on aerial photographs and Custom Soil Resource Report 6

identified each as a specific map unit. Aerial photographs show trees, buildings, fields, roads, and rivers, all of which help in locating boundaries accurately.

Custom Soil Resource Report 7

Soil Map The soil map section includes the soil map for the defined area of interest, a list of soil map units on the map and extent of each map unit, and cartographic symbols displayed on the map. Also presented are various metadata about data used to produce the map, and a description of each soil map unit.

8

9 Custom Soil Resource Report Soil Map 3746700 3747400 3748100 3748800 3749500 3750200 3750900 3746700 3747400 3748100 3748800 3749500 3750200 3750900 503700 504400 505100 505800 506500 507200 507900 508600 509300 510000 510700 503700 504400 505100 505800 506500 507200 507900 508600 509300 510000 510700 33° 54' 2 N 80° 57' 40 W 33° 54' 2 N 80° 53' 1 W 33° 51' 31 N 80° 57' 40 W 33° 51' 31 N 80° 53' 1 W N

Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 17N WGS84 0

1500 3000 6000 9000 Feet 0

450 900 1800 2700 Meters Map Scale: 1:32,800 if printed on A landscape (11" x 8.5") sheet.

MAP LEGEND MAP INFORMATION Area of Interest (AOI)

Area of Interest (AOI)

Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads

Background

Aerial Photography The soil surveys that comprise your AOI were mapped at 1:20,000.

Please rely on the bar scale on each map sheet for map measurements.

Source of Map: Natural Resources Conservation Service Web Soil Survey URL:

Coordinate System: Web Mercator (EPSG:3857)

Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required.

This product is generated from the USDA-NRCS certified data as of the version date(s) listed below.

Soil Survey Area: Richland County, South Carolina Survey Area Data: Version 22, Jun 3, 2020 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger.

Date(s) aerial images were photographed: May 7, 2020Jul 5, 2020 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident.

Custom Soil Resource Report 10

Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI Ca Cantey loam 336.4 6.2%

Cd Chastain silty clay loam 398.1 7.3%

Ce Chewacla loam, 0 to 2 percent slopes, frequently flooded 668.6 12.3%

Cn Clarendon sandy loam 0.0 0.0%

Co Congaree loam 1,336.3 24.6%

Cx Coxville fine sandy loam 54.2 1.0%

DoB Dothan loamy sand, 2 to 6 percent slopes 6.7 0.1%

FaA Faceville sandy loam, 0 to 2 percent slopes 9.1 0.2%

GoA Goldsboro sandy loam, 0 to 2 percent slopes 21.4 0.4%

Jo Johnston loam 109.8 2.0%

M-W Miscellaneous Water 1.3 0.0%

ObA Orangeburg loamy sand, 0 to 2 percent slopes 71.0 1.3%

OgB Orangeburg-Urban land complex, 2 to 6 percent slopes 56.0 1.0%

Ps Persanti very fine sandy loam 901.1 16.6%

Sm Smithboro loam 463.0 8.5%

Tc Tawcaw silty clay loam 868.0 16.0%

To Toccoa loam 103.1 1.9%

VaC Vaucluse loamy sand, 6 to 10 percent slopes 10.4 0.2%

W Water 11.7 0.2%

Totals for Area of Interest 5,426.1 100.0%

Map Unit Descriptions The map units delineated on the detailed soil maps in a soil survey represent the soils or miscellaneous areas in the survey area. The map unit descriptions, along with the maps, can be used to determine the composition and properties of a unit.

A map unit delineation on a soil map represents an area dominated by one or more major kinds of soil or miscellaneous areas. A map unit is identified and named according to the taxonomic classification of the dominant soils. Within a taxonomic class there are precisely defined limits for the properties of the soils. On the landscape, however, the soils are natural phenomena, and they have the Custom Soil Resource Report 11

characteristic variability of all natural phenomena. Thus, the range of some observed properties may extend beyond the limits defined for a taxonomic class.

Areas of soils of a single taxonomic class rarely, if ever, can be mapped without including areas of other taxonomic classes. Consequently, every map unit is made up of the soils or miscellaneous areas for which it is named and some minor components that belong to taxonomic classes other than those of the major soils.

Most minor soils have properties similar to those of the dominant soil or soils in the map unit, and thus they do not affect use and management. These are called noncontrasting, or similar, components. They may or may not be mentioned in a particular map unit description. Other minor components, however, have properties and behavioral characteristics divergent enough to affect use or to require different management. These are called contrasting, or dissimilar, components. They generally are in small areas and could not be mapped separately because of the scale used. Some small areas of strongly contrasting soils or miscellaneous areas are identified by a special symbol on the maps. If included in the database for a given area, the contrasting minor components are identified in the map unit descriptions along with some characteristics of each. A few areas of minor components may not have been observed, and consequently they are not mentioned in the descriptions, especially where the pattern was so complex that it was impractical to make enough observations to identify all the soils and miscellaneous areas on the landscape.

The presence of minor components in a map unit in no way diminishes the usefulness or accuracy of the data. The objective of mapping is not to delineate pure taxonomic classes but rather to separate the landscape into landforms or landform segments that have similar use and management requirements. The delineation of such segments on the map provides sufficient information for the development of resource plans. If intensive use of small areas is planned, however, onsite investigation is needed to define and locate the soils and miscellaneous areas.

An identifying symbol precedes the map unit name in the map unit descriptions.

Each description includes general facts about the unit and gives important soil properties and qualities.

Soils that have profiles that are almost alike make up a soil series. Except for differences in texture of the surface layer, all the soils of a series have major horizons that are similar in composition, thickness, and arrangement.

Soils of one series can differ in texture of the surface layer, slope, stoniness, salinity, degree of erosion, and other characteristics that affect their use. On the basis of such differences, a soil series is divided into soil phases. Most of the areas shown on the detailed soil maps are phases of soil series. The name of a soil phase commonly indicates a feature that affects use or management. For example, Alpha silt loam, 0 to 2 percent slopes, is a phase of the Alpha series.

Some map units are made up of two or more major soils or miscellaneous areas.

These map units are complexes, associations, or undifferentiated groups.

A complex consists of two or more soils or miscellaneous areas in such an intricate pattern or in such small areas that they cannot be shown separately on the maps.

The pattern and proportion of the soils or miscellaneous areas are somewhat similar in all areas. Alpha-Beta complex, 0 to 6 percent slopes, is an example.

An association is made up of two or more geographically associated soils or miscellaneous areas that are shown as one unit on the maps. Because of present or anticipated uses of the map units in the survey area, it was not considered Custom Soil Resource Report 12

practical or necessary to map the soils or miscellaneous areas separately. The pattern and relative proportion of the soils or miscellaneous areas are somewhat similar. Alpha-Beta association, 0 to 2 percent slopes, is an example.

An undifferentiated group is made up of two or more soils or miscellaneous areas that could be mapped individually but are mapped as one unit because similar interpretations can be made for use and management. The pattern and proportion of the soils or miscellaneous areas in a mapped area are not uniform. An area can be made up of only one of the major soils or miscellaneous areas, or it can be made up of all of them. Alpha and Beta soils, 0 to 2 percent slopes, is an example.

Some surveys include miscellaneous areas. Such areas have little or no soil material and support little or no vegetation. Rock outcrop is an example.

Custom Soil Resource Report 13

Richland County, South Carolina CaCantey loam Map Unit Setting National map unit symbol: 4ddh Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Farmland of statewide importance Map Unit Composition Cantey and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Cantey Setting Landform: Depressions, flats, marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Clayey marine deposits Typical profile A - 0 to 5 inches: loam BEg - 5 to 8 inches: sandy loam Btg - 8 to 81 inches: clay Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.57 in/hr)

Depth to water table: About 0 to 12 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Low (about 5.8 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Hydric soil rating: Yes Custom Soil Resource Report 14

CdChastain silty clay loam Map Unit Setting National map unit symbol: 4ddj Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Not prime farmland Map Unit Composition Chastain and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Chastain Setting Landform: Flood plains Down-slope shape: Linear Across-slope shape: Linear Parent material: Clayey alluvium Typical profile A - 0 to 4 inches: silty clay loam Bg - 4 to 18 inches: silty clay loam Bg - 18 to 41 inches: clay Cg - 41 to 82 inches: loamy sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately low to moderately high (0.06 to 0.20 in/hr)

Depth to water table: About 0 to 12 inches Frequency of flooding: FrequentNone Frequency of ponding: None Available water capacity: Moderate (about 6.7 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 6w Hydrologic Soil Group: C/D Hydric soil rating: Yes Custom Soil Resource Report 15

CeChewacla loam, 0 to 2 percent slopes, frequently flooded Map Unit Setting National map unit symbol: 2sclw Elevation: 90 to 1,930 feet Mean annual precipitation: 40 to 69 inches Mean annual air temperature: 50 to 66 degrees F Frost-free period: 180 to 280 days Farmland classification: Prime farmland if drained and either protected from flooding or not frequently flooded during the growing season Map Unit Composition Chewacla, frequently flooded, and similar soils: 80 percent Minor components: 20 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Chewacla, Frequently Flooded Setting Landform: Flood plains Landform position (two-dimensional): Toeslope Landform position (three-dimensional): Talf Down-slope shape: Linear Across-slope shape: Linear Parent material: Alluvium Typical profile A - 0 to 10 inches: loam Bw - 10 to 80 inches: sandy clay loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Somewhat poorly drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr)

Depth to water table: About 6 to 24 inches Frequency of flooding: Frequent Frequency of ponding: None Available water capacity: High (about 10.8 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 4w Hydrologic Soil Group: B/D Hydric soil rating: No Minor Components Toccoa, frequently flooded Percent of map unit: 15 percent Custom Soil Resource Report 16

Landform: Flood plains Landform position (two-dimensional): Toeslope Down-slope shape: Linear Across-slope shape: Linear Hydric soil rating: No Wehadkee, ponded Percent of map unit: 5 percent Landform: Flood plains Landform position (two-dimensional): Toeslope Down-slope shape: Linear Across-slope shape: Linear Hydric soil rating: Yes CnClarendon sandy loam Map Unit Setting National map unit symbol: 4ddm Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: All areas are prime farmland Map Unit Composition Clarendon and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Clarendon Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Loamy marine deposits Typical profile A - 0 to 6 inches: sandy loam E - 6 to 10 inches: sandy loam Bt - 10 to 36 inches: sandy clay loam Btg - 36 to 73 inches: sandy clay loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Moderately well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.57 in/hr)

Depth to water table: About 24 inches Custom Soil Resource Report 17

Frequency of flooding: None Frequency of ponding: None Available water capacity: Moderate (about 7.0 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 2w Hydrologic Soil Group: C Hydric soil rating: No CoCongaree loam Map Unit Setting National map unit symbol: 4ddn Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Prime farmland if protected from flooding or not frequently flooded during the growing season Map Unit Composition Tawcaw and similar soils: 85 percent Minor components: 4 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Tawcaw Setting Landform: Flood plains Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Concave Parent material: Clayey alluvium Typical profile A - 0 to 4 inches: silty clay loam B1 - 4 to 22 inches: silty clay B2 - 22 to 61 inches: silty clay loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Somewhat poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Very low to moderately high (0.00 to 0.57 in/hr)

Depth to water table: About 18 inches Frequency of flooding: OccasionalNone Frequency of ponding: None Available water capacity: High (about 9.8 inches)

Custom Soil Resource Report 18

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Hydric soil rating: No Minor Components Chastain Percent of map unit: 2 percent Landform: Flood plains Down-slope shape: Linear Across-slope shape: Linear Hydric soil rating: Yes Congaree Percent of map unit: 2 percent Landform: Flood plains Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Concave Hydric soil rating: No CxCoxville fine sandy loam Map Unit Setting National map unit symbol: 4ddp Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Farmland of statewide importance Map Unit Composition Coxville and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Coxville Setting Landform: Depressions, flats, marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Clayey marine deposits Typical profile A - 0 to 7 inches: fine sandy loam Eg - 7 to 9 inches: fine sandy loam Btg - 9 to 65 inches: sandy clay Custom Soil Resource Report 19

BCg - 65 to 80 inches: sandy clay loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.57 in/hr)

Depth to water table: About 0 to 12 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: High (about 9.5 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Hydric soil rating: Yes DoBDothan loamy sand, 2 to 6 percent slopes Map Unit Setting National map unit symbol: 2wb94 Elevation: 50 to 660 feet Mean annual precipitation: 40 to 69 inches Mean annual air temperature: 55 to 70 degrees F Frost-free period: 190 to 310 days Farmland classification: All areas are prime farmland Map Unit Composition Dothan and similar soils: 82 percent Minor components: 18 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Dothan Setting Landform: Interfluves Landform position (two-dimensional): Shoulder Landform position (three-dimensional): Interfluve Down-slope shape: Convex Across-slope shape: Linear Parent material: Loamy marine deposits Typical profile Ap - 0 to 7 inches: loamy sand E - 7 to 13 inches: loamy sand Bt - 13 to 40 inches: sandy clay loam Btv - 40 to 79 inches: sandy clay loam Properties and qualities Slope: 2 to 6 percent Custom Soil Resource Report 20

Depth to restrictive feature: More than 80 inches Drainage class: Well drained Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.57 in/hr)

Depth to water table: About 36 to 59 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm)

Available water capacity: Moderate (about 6.8 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 2e Hydrologic Soil Group: B Forage suitability group: Loamy and clayey soils on rises and knolls of mesic uplands (G133AA321FL)

Other vegetative classification: Loamy and clayey soils on rises and knolls of mesic uplands (G133AA321FL)

Hydric soil rating: No Minor Components Norfolk Percent of map unit: 8 percent Landform: Interfluves Landform position (two-dimensional): Shoulder Landform position (three-dimensional): Interfluve Down-slope shape: Convex Across-slope shape: Linear Hydric soil rating: No Fuquay Percent of map unit: 5 percent Landform: Interfluves Landform position (two-dimensional): Shoulder Landform position (three-dimensional): Interfluve Down-slope shape: Convex Across-slope shape: Linear Hydric soil rating: No Orangeburg Percent of map unit: 5 percent Landform: Marine terraces Landform position (two-dimensional): Backslope, shoulder, summit Landform position (three-dimensional): Side slope Down-slope shape: Linear Across-slope shape: Convex, linear Hydric soil rating: No Custom Soil Resource Report 21

FaAFaceville sandy loam, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 4ddv Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: All areas are prime farmland Map Unit Composition Faceville and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Faceville Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Clayey marine deposits Typical profile A - 0 to 7 inches: sandy loam BA - 7 to 12 inches: sandy clay loam Bt - 12 to 84 inches: sandy clay Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr)

Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Moderate (about 8.4 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 1 Hydrologic Soil Group: B Hydric soil rating: No Custom Soil Resource Report 22

GoAGoldsboro sandy loam, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 4df2 Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: All areas are prime farmland Map Unit Composition Goldsboro and similar soils: 90 percent Minor components: 4 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Goldsboro Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Loamy marine deposits Typical profile A - 0 to 7 inches: sandy loam E - 7 to 13 inches: sandy loam BE - 13 to 18 inches: sandy loam Bt - 18 to 65 inches: sandy clay loam Cg - 65 to 80 inches: sandy loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Moderately well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr)

Depth to water table: About 24 to 36 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Moderate (about 7.2 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 2w Hydrologic Soil Group: C Hydric soil rating: No Custom Soil Resource Report 23

Minor Components Coxville Percent of map unit: 2 percent Landform: Flats, marine terraces, depressions Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Hydric soil rating: Yes Rains Percent of map unit: 2 percent Landform: Depressions, flats, marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Hydric soil rating: Yes JoJohnston loam Map Unit Setting National map unit symbol: 4df6 Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Not prime farmland Map Unit Composition Johnston and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Johnston Setting Landform: Flood plains Down-slope shape: Linear Across-slope shape: Linear Parent material: Loamy alluvium Typical profile A1 - 0 to 9 inches: loam A2 - 9 to 38 inches: mucky loam Cg - 38 to 66 inches: fine sandy loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Very poorly drained Runoff class: Very high Custom Soil Resource Report 24

Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 5.95 in/hr)

Depth to water table: About 0 inches Frequency of flooding: FrequentNone Frequency of ponding: None Available water capacity: Moderate (about 8.8 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 7w Hydrologic Soil Group: A/D Hydric soil rating: Yes M-WMiscellaneous Water Map Unit Composition Water: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Water Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 8 Hydric soil rating: No ObAOrangeburg loamy sand, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 4dfp Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: All areas are prime farmland Map Unit Composition Orangeburg and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Orangeburg Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Loamy marine deposits Custom Soil Resource Report 25

Typical profile A - 0 to 5 inches: loamy sand E - 5 to 12 inches: loamy sand BE - 12 to 18 inches: sandy loam Bt - 18 to 90 inches: sandy clay loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr)

Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Moderate (about 7.1 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 1 Hydrologic Soil Group: B Hydric soil rating: No OgBOrangeburg-Urban land complex, 2 to 6 percent slopes Map Unit Setting National map unit symbol: 4dfs Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Not prime farmland Map Unit Composition Orangeburg and similar soils: 60 percent Urban land: 40 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Orangeburg Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Loamy marine deposits Typical profile A - 0 to 5 inches: loamy sand E - 5 to 12 inches: loamy sand BE - 12 to 18 inches: sandy loam Custom Soil Resource Report 26

Bt - 18 to 90 inches: sandy clay loam Properties and qualities Slope: 2 to 6 percent Depth to restrictive feature: More than 80 inches Drainage class: Well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 1.98 in/hr)

Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Moderate (about 7.1 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 2e Hydrologic Soil Group: B Hydric soil rating: No Description of Urban Land Setting Down-slope shape: Linear Across-slope shape: Linear Parent material: Loamy marine deposits Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 8s Hydric soil rating: Unranked PsPersanti very fine sandy loam Map Unit Setting National map unit symbol: 4dfy Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: All areas are prime farmland Map Unit Composition Persanti and similar soils: 96 percent Minor components: 4 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Persanti Setting Landform: Marine terraces Custom Soil Resource Report 27

Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Clayey marine deposits Typical profile Ap - 0 to 5 inches: very fine sandy loam BE - 5 to 10 inches: sandy clay loam Bt - 10 to 75 inches: clay Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Moderately well drained Runoff class: Low Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.57 in/hr)

Depth to water table: About 24 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Low (about 5.9 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 2w Hydrologic Soil Group: C Hydric soil rating: No Minor Components Cantey Percent of map unit: 4 percent Landform: Depressions, flats, marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Hydric soil rating: Yes SmSmithboro loam Map Unit Setting National map unit symbol: 4dg0 Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Farmland of statewide importance Map Unit Composition Smithboro and similar soils: 90 percent Minor components: 4 percent Custom Soil Resource Report 28

Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Smithboro Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Parent material: Clayey marine deposits Typical profile A - 0 to 6 inches: loam BE - 6 to 10 inches: loam Btg1 - 10 to 29 inches: clay loam Btg2 - 29 to 67 inches: clay Btg3 - 67 to 78 inches: silty clay Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Somewhat poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Moderately high (0.20 to 0.57 in/hr)

Depth to water table: About 6 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Moderate (about 7.4 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Hydric soil rating: No Minor Components Cantey Percent of map unit: 4 percent Landform: Marine terraces, depressions, flats Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Convex Hydric soil rating: Yes TcTawcaw silty clay loam Map Unit Setting National map unit symbol: 4dg2 Elevation: 80 to 550 feet Custom Soil Resource Report 29

Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Not prime farmland Map Unit Composition Tawcaw and similar soils: 85 percent Minor components: 5 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Tawcaw Setting Landform: Flood plains Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Concave Parent material: Clayey alluvium Typical profile A - 0 to 4 inches: silty clay loam B1 - 4 to 22 inches: silty clay B2 - 22 to 61 inches: silty clay loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Somewhat poorly drained Runoff class: Very high Capacity of the most limiting layer to transmit water (Ksat): Very low to moderately high (0.00 to 0.57 in/hr)

Depth to water table: About 18 inches Frequency of flooding: OccasionalNone Frequency of ponding: None Available water capacity: High (about 9.8 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Hydric soil rating: No Minor Components Chastain Percent of map unit: 5 percent Landform: Flood plains Down-slope shape: Linear Across-slope shape: Linear Hydric soil rating: Yes Custom Soil Resource Report 30

ToToccoa loam Map Unit Setting National map unit symbol: 4dg3 Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Prime farmland if protected from flooding or not frequently flooded during the growing season Map Unit Composition Toccoa and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Toccoa Setting Landform: Flood plains Landform position (three-dimensional): Tread Down-slope shape: Linear Across-slope shape: Concave Parent material: Loamy alluvium Typical profile A - 0 to 4 inches: loam C1 - 4 to 12 inches: loam C2 - 12 to 45 inches: fine sandy loam C3 - 45 to 60 inches: loamy sand C4 - 60 to 68 inches: fine sand C5 - 68 to 72 inches: fine sandy loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Moderately well drained Runoff class: Very low Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 5.95 in/hr)

Depth to water table: About 30 inches Frequency of flooding: Occasional Frequency of ponding: None Available water capacity: Moderate (about 8.2 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: B Hydric soil rating: No Custom Soil Resource Report 31

VaCVaucluse loamy sand, 6 to 10 percent slopes Map Unit Setting National map unit symbol: 4dg7 Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Not prime farmland Map Unit Composition Vaucluse and similar soils: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Description of Vaucluse Setting Landform: Marine terraces Landform position (three-dimensional): Tread Down-slope shape: Convex Across-slope shape: Convex Parent material: Loamy marine deposits Typical profile Ap - 0 to 6 inches: loamy sand E - 6 to 15 inches: loamy sand Bt - 15 to 29 inches: sandy clay loam Bx - 29 to 58 inches: sandy clay loam BC - 58 to 72 inches: sandy loam Properties and qualities Slope: 6 to 10 percent Depth to restrictive feature: More than 80 inches Drainage class: Well drained Runoff class: Medium Capacity of the most limiting layer to transmit water (Ksat): Very low to moderately high (0.00 to 0.57 in/hr)

Depth to water table: More than 80 inches Frequency of flooding: None Frequency of ponding: None Available water capacity: Low (about 4.6 inches)

Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3e Hydrologic Soil Group: C Ecological site: F137XY006GA - Loamy Backslope Woodland - PROVISIONAL Hydric soil rating: No Custom Soil Resource Report 32

WWater Map Unit Setting National map unit symbol: 4dg9 Elevation: 80 to 550 feet Mean annual precipitation: 44 to 55 inches Mean annual air temperature: 61 to 70 degrees F Frost-free period: 230 to 265 days Farmland classification: Not prime farmland Map Unit Composition Water: 100 percent Estimates are based on observations, descriptions, and transects of the mapunit.

Custom Soil Resource Report 33

Soil Information for All Uses Suitabilities and Limitations for Use The Suitabilities and Limitations for Use section includes various soil interpretations displayed as thematic maps with a summary table for the soil map units in the selected area of interest. A single value or rating for each map unit is generated by aggregating the interpretive ratings of individual map unit components. This aggregation process is defined for each interpretation.

Land Classifications Land Classifications are specified land use and management groupings that are assigned to soil areas because combinations of soil have similar behavior for specified practices. Most are based on soil properties and other factors that directly influence the specific use of the soil. Example classifications include ecological site classification, farmland classification, irrigated and nonirrigated land capability classification, and hydric rating.

Farmland Classification Farmland classification identifies map units as prime farmland, farmland of statewide importance, farmland of local importance, or unique farmland. It identifies the location and extent of the soils that are best suited to food, feed, fiber, forage, and oilseed crops. NRCS policy and procedures on prime and unique farmlands are published in the "Federal Register," Vol. 43, No. 21, January 31, 1978.

34

35 Custom Soil Resource Report MapFarmland Classification 3746700 3747400 3748100 3748800 3749500 3750200 3750900 3746700 3747400 3748100 3748800 3749500 3750200 3750900 503700 504400 505100 505800 506500 507200 507900 508600 509300 510000 510700 503700 504400 505100 505800 506500 507200 507900 508600 509300 510000 510700 33° 54' 2 N 80° 57' 40 W 33° 54' 2 N 80° 53' 1 W 33° 51' 31 N 80° 57' 40 W 33° 51' 31 N 80° 53' 1 W N

Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 17N WGS84 0

1500 3000 6000 9000 Feet 0

450 900 1800 2700 Meters Map Scale: 1:32,800 if printed on A landscape (11" x 8.5") sheet.

MAP LEGEND Area of Interest (AOI)

Area of Interest (AOI)

Soils Soil Rating Polygons Not prime farmland All areas are prime farmland Prime farmland if drained Prime farmland if protected from flooding or not frequently flooded during the growing season Prime farmland if irrigated Prime farmland if drained and either protected from flooding or not frequently flooded during the growing season Prime farmland if irrigated and drained Prime farmland if irrigated and either protected from flooding or not frequently flooded during the growing season Prime farmland if subsoiled, completely removing the root inhibiting soil layer Prime farmland if irrigated and the product of I (soil erodibility) x C (climate factor) does not exceed 60 Prime farmland if irrigated and reclaimed of excess salts and sodium Farmland of statewide importance Farmland of statewide importance, if drained Farmland of statewide importance, if protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if irrigated Farmland of statewide importance, if drained and either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if irrigated and drained Farmland of statewide importance, if irrigated and either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if subsoiled, completely removing the root inhibiting soil layer Farmland of statewide importance, if irrigated and the product of I (soil erodibility) x C (climate factor) does not exceed 60 Farmland of statewide importance, if irrigated and reclaimed of excess salts and sodium Farmland of statewide importance, if drained or either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if warm enough, and either drained or either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if warm enough Farmland of statewide importance, if thawed Farmland of local importance Farmland of local importance, if irrigated Farmland of unique importance Not rated or not available Soil Rating Lines Not prime farmland All areas are prime farmland Prime farmland if drained Prime farmland if protected from flooding or not frequently flooded during the growing season Prime farmland if irrigated Prime farmland if drained and either protected from flooding or not frequently flooded during the growing season Prime farmland if irrigated and drained Prime farmland if irrigated and either protected from flooding or not frequently flooded during the growing season Custom Soil Resource Report 36

Prime farmland if subsoiled, completely removing the root inhibiting soil layer Prime farmland if irrigated and the product of I (soil erodibility) x C (climate factor) does not exceed 60 Prime farmland if irrigated and reclaimed of excess salts and sodium Farmland of statewide importance Farmland of statewide importance, if drained Farmland of statewide importance, if protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if irrigated Farmland of statewide importance, if drained and either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if irrigated and drained Farmland of statewide importance, if irrigated and either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if subsoiled, completely removing the root inhibiting soil layer Farmland of statewide importance, if irrigated and the product of I (soil erodibility) x C (climate factor) does not exceed 60 Farmland of statewide importance, if irrigated and reclaimed of excess salts and sodium Farmland of statewide importance, if drained or either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if warm enough, and either drained or either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if warm enough Farmland of statewide importance, if thawed Farmland of local importance Farmland of local importance, if irrigated Farmland of unique importance Not rated or not available Soil Rating Points Not prime farmland All areas are prime farmland Prime farmland if drained Prime farmland if protected from flooding or not frequently flooded during the growing season Prime farmland if irrigated Prime farmland if drained and either protected from flooding or not frequently flooded during the growing season Prime farmland if irrigated and drained Prime farmland if irrigated and either protected from flooding or not frequently flooded during the growing season Prime farmland if subsoiled, completely removing the root inhibiting soil layer Prime farmland if irrigated and the product of I (soil erodibility) x C (climate factor) does not exceed 60 Prime farmland if irrigated and reclaimed of excess salts and sodium Farmland of statewide importance Farmland of statewide importance, if drained Farmland of statewide importance, if protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if irrigated Custom Soil Resource Report 37

Farmland of statewide importance, if drained and either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if irrigated and drained Farmland of statewide importance, if irrigated and either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if subsoiled, completely removing the root inhibiting soil layer Farmland of statewide importance, if irrigated and the product of I (soil erodibility) x C (climate factor) does not exceed 60 Farmland of statewide importance, if irrigated and reclaimed of excess salts and sodium Farmland of statewide importance, if drained or either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if warm enough, and either drained or either protected from flooding or not frequently flooded during the growing season Farmland of statewide importance, if warm enough Farmland of statewide importance, if thawed Farmland of local importance Farmland of local importance, if irrigated Farmland of unique importance Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads

Background

Aerial Photography The soil surveys that comprise your AOI were mapped at 1:20,000.

Please rely on the bar scale on each map sheet for map measurements.

Source of Map: Natural Resources Conservation Service Web Soil Survey URL:

Coordinate System: Web Mercator (EPSG:3857)

Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required.

This product is generated from the USDA-NRCS certified data as of the version date(s) listed below.

Soil Survey Area: Richland County, South Carolina Survey Area Data: Version 22, Jun 3, 2020 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger.

Date(s) aerial images were photographed: May 7, 2020Jul 5, 2020 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident.

Custom Soil Resource Report 38

TableFarmland Classification Map unit symbol Map unit name Rating Acres in AOI Percent of AOI Ca Cantey loam Farmland of statewide importance 336.4 6.2%

Cd Chastain silty clay loam Not prime farmland 398.1 7.3%

Ce Chewacla loam, 0 to 2 percent slopes, frequently flooded Prime farmland if drained and either protected from flooding or not frequently flooded during the growing season 668.6 12.3%

Cn Clarendon sandy loam All areas are prime farmland 0.0 0.0%

Co Congaree loam Prime farmland if protected from flooding or not frequently flooded during the growing season 1,336.3 24.6%

Cx Coxville fine sandy loam Farmland of statewide importance 54.2 1.0%

DoB Dothan loamy sand, 2 to 6 percent slopes All areas are prime farmland 6.7 0.1%

FaA Faceville sandy loam, 0 to 2 percent slopes All areas are prime farmland 9.1 0.2%

GoA Goldsboro sandy loam, 0 to 2 percent slopes All areas are prime farmland 21.4 0.4%

Jo Johnston loam Not prime farmland 109.8 2.0%

M-W Miscellaneous Water Not prime farmland 1.3 0.0%

ObA Orangeburg loamy sand, 0 to 2 percent slopes All areas are prime farmland 71.0 1.3%

OgB Orangeburg-Urban land complex, 2 to 6 percent slopes Not prime farmland 56.0 1.0%

Ps Persanti very fine sandy loam All areas are prime farmland 901.1 16.6%

Sm Smithboro loam Farmland of statewide importance 463.0 8.5%

Tc Tawcaw silty clay loam Not prime farmland 868.0 16.0%

To Toccoa loam Prime farmland if protected from flooding or not frequently flooded during the growing season 103.1 1.9%

VaC Vaucluse loamy sand, 6 to 10 percent slopes Not prime farmland 10.4 0.2%

W Water Not prime farmland 11.7 0.2%

Totals for Area of Interest 5,426.1 100.0%

Custom Soil Resource Report 39

Rating OptionsFarmland Classification Aggregation Method: No Aggregation Necessary Tie-break Rule: Lower Custom Soil Resource Report 40

References American Association of State Highway and Transportation Officials (AASHTO).

2004. Standard specifications for transportation materials and methods of sampling and testing. 24th edition.

American Society for Testing and Materials (ASTM). 2005. Standard classification of soils for engineering purposes. ASTM Standard D2487-00.

Cowardin, L.M., V. Carter, F.C. Golet, and E.T. LaRoe. 1979. Classification of wetlands and deep-water habitats of the United States. U.S. Fish and Wildlife Service FWS/OBS-79/31.

Federal Register. July 13, 1994. Changes in hydric soils of the United States.

Federal Register. September 18, 2002. Hydric soils of the United States.

Hurt, G.W., and L.M. Vasilas, editors. Version 6.0, 2006. Field indicators of hydric soils in the United States.

National Research Council. 1995. Wetlands: Characteristics and boundaries.

Soil Survey Division Staff. 1993. Soil survey manual. Soil Conservation Service.

U.S. Department of Agriculture Handbook 18. http://www.nrcs.usda.gov/wps/portal/

nrcs/detail/national/soils/?cid=nrcs142p2_054262 Soil Survey Staff. 1999. Soil taxonomy: A basic system of soil classification for making and interpreting soil surveys. 2nd edition. Natural Resources Conservation Service, U.S. Department of Agriculture Handbook 436. http://

www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053577 Soil Survey Staff. 2010. Keys to soil taxonomy. 11th edition. U.S. Department of Agriculture, Natural Resources Conservation Service. http://

www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?cid=nrcs142p2_053580 Tiner, R.W., Jr. 1985. Wetlands of Delaware. U.S. Fish and Wildlife Service and Delaware Department of Natural Resources and Environmental Control, Wetlands Section.

United States Army Corps of Engineers, Environmental Laboratory. 1987. Corps of Engineers wetlands delineation manual. Waterways Experiment Station Technical Report Y-87-1.

United States Department of Agriculture, Natural Resources Conservation Service.

National forestry manual. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/soils/

home/?cid=nrcs142p2_053374 United States Department of Agriculture, Natural Resources Conservation Service.

National range and pasture handbook. http://www.nrcs.usda.gov/wps/portal/nrcs/

detail/national/landuse/rangepasture/?cid=stelprdb1043084 41

United States Department of Agriculture, Natural Resources Conservation Service.

National soil survey handbook, title 430-VI. http://www.nrcs.usda.gov/wps/portal/

nrcs/detail/soils/scientists/?cid=nrcs142p2_054242 United States Department of Agriculture, Natural Resources Conservation Service.

2006. Land resource regions and major land resource areas of the United States, the Caribbean, and the Pacific Basin. U.S. Department of Agriculture Handbook 296. http://www.nrcs.usda.gov/wps/portal/nrcs/detail/national/soils/?

cid=nrcs142p2_053624 United States Department of Agriculture, Soil Conservation Service. 1961. Land capability classification. U.S. Department of Agriculture Handbook 210. http://

www.nrcs.usda.gov/Internet/FSE_DOCUMENTS/nrcs142p2_052290.pdf Custom Soil Resource Report 42