ML21175A301
| ML21175A301 | |
| Person / Time | |
|---|---|
| Issue date: | 07/15/2021 |
| From: | Dickson T, Dyszel A, Patrick Raynaud, Matthew Smith NRC/RES/DE/CIB, Numark Associates |
| To: | |
| Raynaud P | |
| Shared Package | |
| ML21189A208 | List: |
| References | |
| TLR-RES/DE/REB-2021-04 | |
| Download: ML21175A301 (178) | |
Text
Technical Letter Report TLR-RES/DE/REB-2021-04 Fracture Analysis of Vessels - Oak Ridge FAVOR v20.1.12 Users Guide Date:
Drafted: September 2020 Updated: June 2021 Completed: June 2021 NUMARK Associates, Inc:
Terry Dickson Marvin Smith Andrew Dyszel Subject Matter Expert Project Manager Senior Technical Reviewer NRC Contributors:
Patrick Raynaud Senior Materials Engineer Component Integrity Branch Division of Engineering Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
i DISCLAIMER This report was prepared as an account of work sponsored by an agency of the U.S. Government.
Neither the U.S. Government nor any agency thereof, nor any employee, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third party's use, or the results of such use, of any information, apparatus, product, or process disclosed in this publication, or represents that its use by such third party complies with applicable law.
iii This report does not contain or imply legally binding requirements. Nor does this report establish or modify any regulatory guidance or positions of the U.S. Nuclear Regulatory Commission and is not binding on the Commission.
v CONTENTS Page CONTENTS.......................................................................................................................................................... v LIST OF TABLES...............................................................................................................................................vi LIST OF FIGURES........................................................................................................................................... vii EXECUTIVE
SUMMARY
.................................................................................................................................ix ACRONYMS.......................................................................................................................................................xi ACKNOWLEDGMENTS................................................................................................................................. xii 1.
Introduction................................................................................................................................................. 1 1.1 Background......................................................................................................................................... 1 1.2 PTS Re-Evaluation Project................................................................................................................ 6 1.3 Overview - Structure and Organization of the FAVOR Code....................................................... 8 1.4 Installation......................................................................................................................................... 18 1.5 Execution........................................................................................................................................... 20 1.6 Distribution WINZIP package file.................................................................................................. 29 2. FAVOR Input Requirements....................................................................................................................... 36 2.1 FAVOR Load Module - FAVLoad................................................................................................. 36 2.2 FAVOR PFM Module - FAVPFM.................................................................................................. 48 2.3 FAVOR Post-Processing Module - FAVPost................................................................................. 68 2.4 Content and Format for Flaw Distribution Databases.................................................................. 70 2.4.1 Method of Quantifying Uncertainty in Flaw Characterization................................................ 70 2.4.2 Flaw-Characterization File Names and Sizes............................................................................. 71 2.4.3 Surface Breaking Flaws (Flaw Category 1)................................................................................ 71 2.4.4 Embedded flaw Characterization for Welds (Categories 2 and 3 flaws)................................. 74 2.4.5 Embedded-Flaw Characterization for Plates............................................................................. 77 2.4.6 Total Number of Flaws................................................................................................................. 79 2.5 FAVOR Load Module - FAVLoad Output.................................................................................... 80 2.6 FAVOR PFM Module - FAVPFM Output..................................................................................... 82 2.7 FAVOR Post-Processing Module - FAVPost Output.................................................................. 101 3. Example Case............................................................................................................................................... 111 4. Summary and Conclusions......................................................................................................................... 126 5. References.................................................................................................................................................... 127 6. Appendix A - Treatment of Weld Fusion Lines...................................................................................... 130 7. Appendix B - Summary of RVID2 Data for Use in FAVOR Calculations........................................... 133 8. Appendix C - As-Found Flaw FAVOR Version 20.1 Input....................................................................136 9. Appendix D - FAVOR Error Codes....................................................................................................... 164
vi LIST OF TABLES Table Page
- 1. Record Keywords and Parameter Fields for FAVLoad Input File.................................... 37
- 2. Record Keywords and Parameter Fields for FAVPFM Input File.................................... 51
- 3. Record Keywords and Parameters for FAVPost Input File............................................... 68
- 4. Example FAVLoad Load Input and Output Datasets....................................................... 113
- 5. Example FAVPFM Input and Output Files for Deterministic Time Histories for Various Surface Breaking Flaws Geometries, Orientations, and Vessel Geometries........... 113
- 6. Example FAVPFM Input and Output Files for Deterministic Time Histories for Various Embedded Flaws Geometries, Orientations............................................................... 114
- 7. Example FAVPFM Input and Output Files for Deterministic Through-Wall Spatial Profiles of Fracture-Related Variables for Various Surface Breaking Flaws Geometries, Orientations, and Vessel Geometries.......................................................................... 114
vii LIST OF FIGURES Figure Page
- 1. The beltline region of the reactor pressure vessel wall extends from approximately one foot above the active reactor core to one foot below the core for a pressurized water reactor (PWR)................................................................................................................................. 3
- 2. Depiction of the development history of the FAVOR PFM code.......................................... 6
- 3. The PTS Re-Evaluation Project incorporates advancements across a range of technical disciplines relevant to PTS assessment methodologies................................................... 7
- 4. FAVOR data streams flow through three modules: (1) FAVLoad, (2) FAVPFM, and (3)
FAVPost............................................................................................................................. 8
- 5. The global modeling approach in FAVOR allows the entire beltline to be simulated in one model definition............................................................................................................... 10
- 6. Flaw models available in FAVOR.......................................................................................... 10
- 7. The FAVOR load generator module FAVLoad performs deterministic analyses for a range of thermal-hydraulic transients..................................................................................... 17
- 8. The FAVPFM module takes output from FAVLoad and user-supplied data on flaw distributions and embrittlement of the RPV beltline and generates PFMI (INITIATE.DAT) and PFMF (FAILURE.DAT) arrays.............................................. 17
- 9. The FAVOR post-processor FAVPost combines the distributions of conditional probability of initiation and failure calculated by FAVPFM with initiating frequency distributions for all of the transients under study to create distributions of frequencies of RPV fracture and failure......................................................................................................... 18
- 10. Contents of the FAVOR WINZIP package file................................................................... 19
- 11. Execution of the FAVLoad module: (a) type in FAVLoad at the line prompt and (b) respond to prompts for the input and output file names....................................... 21
- 12. FAVLoad calculates thermal, stress, and applied KI loading for all of the transients defined in the input file................................................................................................................. 22
- 13. Type FAVPFM at the Command Prompt to begin execution of the FAVPFM module. 22
- 14. (a) FAVPFM prompts for the names of the (1) FAVPFM input file, (2) FAVLoad-generated load-definition file, (3) FAVPFM output file, (4) flaw-characterization file for surface-breaking flaws in welds and plates, (5) flaw-characterization file for embedded flaws in welds, and (6) flaw-characterization file for embedded flaws in plates...................... 23
- 14. (b) For a restart case, FAVPFM will also prompt for the binary restart file created in a previous execution (see Record 1 - CNT 1 for details regarding restart cases)........ 24
- 15. FAVPFM continually writes out progress reports in terms of running average CPI/CPF values for each transient as the code proceeds through the required number of RPV trials.................................................................................................................................. 25 16(a). Type in FAVPost at the Command Prompt to execute the FAVPost module. FAVPost prompts for the (1) FAVPost input file, (2) CPI matrix file generated by FAVPFM, (3)
CPF matrix file generated by FAVPFM, and (4) the FAVPost output file................ 27 16(b) Set the total number of simulations to be processed and build convergence tables, if required............................................................................................................................ 28
- 17. Weld fusion area definitions for (a) axial-weld subregion elements and (b) circumferential-weld subregion elements................................................................................................. 65
- 17. (continued) (c) Plate subregion element.............................................................................. 66
- 18. Empirical distribution functions for n = 10,000 example problem: (a) histogram and (b) semi-log plot of empirical c.d.f. for frequency of crack initiation, (c) histogram and (d) semi-log plot empirical c.d.f. for through-wall cracking frequency.................... 104
viii
- 18. (continued ) Semi-log plots of empirical distribution functions with fitted exponential right tail for n = 10,000 example problem: (e) mixed empirical/exponential c.d.f. for frequency of crack initiation and (f) mixed empirical/exponential c.d.f. for through-wall cracking frequency........................................................................................................ 105
- 19. Example case - (a) rollout of beltline region of vessel showing layout of plates and welds and (b) axial and circumferential distribution of fast-neutron fluence across the beltline.
........................................................................................................................................ 123
- 20. Time histories of coolant temperature for four PTS transients...................................... 124 21.Time histories of convection heat transfer coefficient four PTS transients.................... 124
- 22. Time histories for internal pressure for four PTS transients.......................................... 125
- 23. Initiation event frequency distribution for PTS Transients 7, 9, 56, and 97................. 125 A1. FAVOR uses a discretization of the RPV beltline region to resolve the variation in radiation damage in terms of plate, axial weld, and circumferential weld major regions which are further discretized into multiple subregions............................................. 131
ix EXECUTIVE
SUMMARY
The Fracture Analysis of Vessels - Oak Ridge (FAVOR) computer program has been developed to perform deterministic and probabilistic risk-informed analyses of the structural integrity of a nuclear reactor pressure vessel (RPV) when subjected to a range of thermal-hydraulic events. The focus of this analysis is the beltline region of the RPV wall.
Overcooling events, where the temperature of the coolant in contact with the inner surface of the RPV wall rapidly decreases with time, produce time-dependent temperature gradients that induce biaxial stress states varying in magnitude through the vessel wall. Near the inner surface and through most of the wall thickness, the stresses are tensile, thus generating Mode I opening driving forces that can act on possible existing internal surface-breaking or embedded flaws near the wetted inner surface. If the internal pressure of the coolant is sufficiently high, then the combined thermal plus mechanical loading results in a transient condition known as a pressurized-thermal shock (PTS) event.
Normal planned reactor operational transients, such as start-up, cool-down, and leak-test can also present challenges to the structural integrity of the RPV. FAVOR, v16.1 is an evolution of the FAVOR code (version 06.1) used to develop the PTS risk estimates reported in NUREGs-1806 and 1874, which were published in 2006 and 2007, respectively.
In 1999 ORNL, working in cooperation with the NRC staff and with other NRC contractors, illustrated that the application of fracture-related technology developed since the derivation of the current pressurized-thermal-shock (PTS) regulations (established in the 1980s) had the potential for providing a technical basis for a re-evaluation of the then-current PTS regulations. Motivated by these findings, the U.S. Nuclear Regulatory Commission (NRC) began the PTS Re-evaluation Project to develop a technical basis to support a revision to the rule within the framework established by modern probabilistic risk assessment techniques and advances in the technologies associated with the physics of PTS events.
An updated computational methodology was developed through research and interactions among experts in the relevant disciplines of thermal-hydraulics, probabilistic risk assessment (PRA),
materials embrittlement, probabilistic fracture mechanics (PFM), and inspection (flaw characterization). Major differences between this methodology and that used to establish the tech-nical basis for the original version of the PTS rule include the following:
the ability to incorporate new detailed flaw-characterization distributions from NRC research obtained via work performed at the Pacific Northwest National Laboratory,
- PNNL,
the ability to incorporate detailed neutron fluence maps,
the ability to incorporate warm-prestressing effects into the analysis,
the ability to include temperature-dependencies in the thermo-elastic properties of base and
- cladding,
the ability to include crack-face pressure loading for surface-breaking flaws,
the addition of a new ductile-fracture model simulating stable and unstable ductile tearing,
the addition of a new embrittlement correlation,
the ability to include multiple transients in one execution of FAVOR,
the ability to include input from the Reactor Vessel Integrity Database, Revision 2, (RVID2) of relevant RPV material properties,
x
the addition of new fracture-toughness models based on extended databases and improved statistical distributions,
the addition of a variable failure criterion, i.e., how far must a flaw propagate into the RPV wall for the vessel simulation to be considered as failed ?
the addition of semi-elliptic surface-breaking and embedded-flaw models,
the addition of through-wall weld stresses,
the addition of base material SIFIC(s) from the ASME code,Section XI, Appendix A, Article A-3000, Method of KI Determination, for infinite and finite axial and 360 continuous and finite circumferential flaws into the FAVOR SIFIC database, and
the implementation of improved PFM methodology that incorporates modern PRA procedures for the classification and propagation of input uncertainties and the characterization of output uncertainties as statistical distributions.
These updated methodologies were implemented into the FAVOR computer code, which was then subjected to extensive verification studies. A specific version, FAVOR, v06.1, was used to develop the PTS TWCF estimates reported in NUREG-1806 and NUREG-1874, which were published in 2006 and 2007, respectively. The TWCF estimates in NUREG-1874 formed part of the technical basis for the alternate PTS rule (10 CFR 50.61a).
The FAVOR computer code has continued to evolve and to be extensively applied by analysts from the nuclear industry, both nationally and internationally, and by regulators at the NRC. FAVOR, V20.1 has added the capability to evaluate as-found flaws to v16.1, and retains backward compability with FAVOR 16.1 to do analyses of flaws as defined with VFLAW. This report documents the technical bases for the assumptions, algorithms, methods, and correlations employed in the development of the FAVOR code.
xi ACRONYMS BNL Brookhaven National Laboratory EFPY effective full-power years EOL end-of-licensing IPTS Integrated Pressurized Thermal Shock Program LEFM linear-elastic fracture mechanics LOCA loss-of-coolant accident ORNL Oak Ridge National Laboratory NRC United States Nuclear Regulatory Commission PFM probabilistic fracture mechanics PNNL Pacific Northwest National Laboratory PRA Probabilistic Risk Assessment PTS pressurized thermal shock PWR pressurized water reactor RPV reactor pressure vessel T-E thermo-elastic T-H thermal-hydraulic
xii ACKNOWLEDGMENTS FAVOR 20.1.12 was developed in a collaborative manner by a team composed of:
Terry Dickson, Andrew Dyszel, and Marvin Smith, of NUMARK Associates, Inc.
Brad Richardson, Karla Morris, Kate Rasmussen, and Damian Rouson, of Sourcery Inc.
Giovanni Facco, James Burke, and Patrick Raynaud, of the NRC's Office of Nuclear Regulatory Research.
This work was sponsored by the U.S. NRC.
1
- 1. Introduction
1.1 Background
In 1999, Dickson et al. [1]illustrated that the application of fracture-related technology developed since the derivation of the original pressurized-thermal-shock (PTS) rules (established in the early-mid 1980s) had the potential to better inform the basis of the then-extant PTS regulations. An updated computational methodology was developed over several years through research and interactions among experts in the relevant disciplines of thermal-hydraulics, probabilistic risk assessment (PRA),
materials embrittlement, probabilistic fracture mechanics (PFM), and inspection (flaw characterization).
This updated methodology has been implemented into the Fracture Analysis of Vessels - Oak Ridge computer code developed at Oak Ridge National Laboratory (ORNL) for the U.S. Nuclear Regulatory Commission (NRC). FAVOR was applied in the PTS Re-evaluation Project to successfully establish a technical basis supporting an alternative to the original PTS Rule (Title 10 of the Code of Federal Regulations, Chapter I, Part 50, Section 50.61, 10CFR50.61) within the framework established by modern probabilistic risk assessment techniques and advances in the technologies associated with the physics of PTS events. The alternative PTS rule has been codified in 10 CFR 50.61(a).
The FAVOR computer code continues to evolve. Extensively applied by analysts from the nuclear industry and regulators at the NRC, FAVOR incorporates fracture mechanics and risk-informed methodologies to assess and update regulations designed to insure that the structural integrity of aging nuclear reactor pressure vessels (RPVs) is maintained throughout the licensing period of the reactor.
The analysis of PTS was the primary motivation in the development of FAVOR; however, the problem class for which FAVOR is applicable encompasses a broad range of events that include normal operational transients (such as start-up, shut-down, and leak-test) as well as upset conditions beyond PTS. Essentially any event in which the RPV wall is exposed to time-varying thermal-hydraulic boundary conditions would be an appropriate candidate for a FAVOR analysis of the vessels structural integrity.
Earlier versions of FAVOR were developed to perform deterministic and risk-informed probabilistic analyses of the structural integrity of a nuclear RPV when subjected to overcooling events such as PTS accidental transients and normal cool-down transients such as those associated with reactor shutdown. Overcooling events, where the temperature of the coolant in contact with the inner surface
2 of the RPV wall decreases with time, produce time-dependent temperature and stress gradients that are tensile on and near the RPV inner surface, thus generating Mode I opening driving forces that tend to open inner surface-breaking or embedded flaws located near the inner surface of the RPV wall.
The Fracture Analysis of Vessels - Oak Ridge Heat-Up (FAVORHT) computer program was previously developed to perform deterministic and probabilistic fracture analyses of a nuclear RPV subjected to heat-up events, such as those transients associated with the start-up of reactors. Heat-up events, where the temperature of the coolant in contact with the inner surface of the RPV wall increases with time, produce time-dependent temperature and stress gradients that are tensile on and near the RPV external surface, thus generating Mode I opening driving forces that tend to open external surface-breaking or embedded flaws located near the external surface of the reactor vessel wall. The focus of these analyses of both overcooling and heat-up events is the beltline region of the RPV wall as shown in Fig. 1.
A limitation of the earlier versions of FAVOR is that they performed analyses of reactor vessels with an internal radius, Ri, to wall thickness, t, (Ri/t), ratio of approximately 10; this value for Ri/t being characteristic of pressurized water reactors (PWRs). Most boiling water reactors (BWRs) have Ri/t ratios of approximately 20, although a few BWRs in the United States have Ri/t ratios between 10 and
- 20. This limitation was removed in FAVOR, v09.1.
An objective of FAVOR is to continue to consolidate and expand the modeling and analysis capabilities of the previous versions of FAVOR and FAVORHT discussed above into a single computer program. FAVOR has, therefore, now been generalized to provide the capability to perform deterministic and probabilistic fracture analyses of PWRs and BWRs vessels subjected to cool-down and /or heat-up transients.
The FAVOR code represents the latest NRC applications tool for performing deterministic and risk-informed probabilistic fracture analyses of RPVs. This report is intended as a users guide to the computer system requirements, installation, and execution of the FAVOR, v16.1, deterministic and probabilistic fracture mechanics code. Detailed instructions on input data deck preparation are presented along with a description of all output files. Example input and output cases are included. A detailed review of these advancements as implemented into the current release of FAVOR is presented in the companion report FAVOR (v16.1): Theory and Implementation of Algorithms, Methods, and Correlations [2].
Update to 20.1
3 Fig. 1. The beltline region of the reactor pressure vessel wall extends from approximately one foot above the active reactor core to one foot below the core (adapted from [3]) for a pressurized water reactor (PWR).
4 Concern with PTS results from the combined effects of (1) simultaneous pressure and thermal-shock loadings, (2) embrittlement of the vessel due to cumulative irradiation exposure over the operating life of the vessel, and (3) the possible existence of crack-like defects at the inner surface of or embedded within the RPV heavy-section wall. The decrease in vessel temperature associated with a thermal shock also reduces the fracture toughness of the vessel and introduces the possibility of flaw propagation. Inner surface-breaking flaws and embedded flaws near the inner surface are particularly vulnerable, because at the inner surface the temperature is at its minimum and the stress and radiation-induced embrittlement are at their maximum.
The PTS issue has been under investigation for many years. Most of the early PTS analyses were of a deterministic nature. In an effort to establish more realistic limiting values of vessel embrittlement, the United States Nuclear Regulatory Commission (NRC) funded during the 1980s the Integrated Pressurized Thermal Shock (IPTS) Program [3-5] which developed a comprehensive probabilistic approach to risk assessment. Current regulatory requirements are based on the resulting risk-informed probabilistic methodology. In the early 1980s, extensive analyses were performed by the NRC and others to estimate the likelihood of vessel failure due to PTS events in PWRs. Though a large number of parameters governing vessel failure were identified, the single most significant parameter was a correlative index of the material that also serves as a measure of embrittlement. This material index is the reference nil-ductility transition temperature, RTNDT. The NRC staff and others performed analyses of PTS risks on a conservative and generic basis to bound the risk of vessel failure for any PWR reactor. These analyses led to the establishment of the PTS Rule [6], promulgated in Title 10 of the Code of Federal Regulations, Chapter I, Part 50, Section 50.61 (10CFR50.61), and the issuance of the NRC Regulatory Guide 1.154 (RG1.154) [7].
The original PTS Rule specifies screening criteria in the form of limiting irradiated values of RTNDT (designated by the rule as RTPTS) of 270 F for axially-oriented welds, plates, and forgings and 300 F for circumferentially-oriented welds. The PTS Rule also prescribes a method to estimate RTPTS for materials in an RPV in Regulatory Guide 1.99, Revision 2 [8]. For nuclear power plants to operate beyond the time that they exceed the screening criteria, the licensees must submit a plant-specific safety analysis to the NRC three years before the screening limit is anticipated to be reached..
In 2007, the NRC published a proposed amendment [9] (10CFR50.61a) to the PTS Rule. In 10CFR50.61a, the NRC is recommending to amend its regulations to provide updated fracture toughness requirements for protection against PTS events for PWRs. These new requirements would be voluntarily utilized by any PWR licensee as an alternative to complying with the existing
5 requirements in 10CFR50.61. The technical bases for the amended PTS Rule are reported in ref. [10]
in which the FAVOR code played a critical role. The recommended screening limits for PTS in 10CFR50.61a are discussed in ref. [11] which includes the following description:
The NRC staff recommends using different reference temperature (RT) metrics to characterize the resistance of an RPV to fractures initiating from different flaws at different locations in the vessel. Specifically, the staff recommends an RT for flaws occurring along axial weld fusion lines (RTMAX-AW), another for the embedded flaws occurring in plates (RTMAX-PL), a third for flaws occurring along circumferential weld fusion lines (RTMAX-CW), and a fourth for embedded and/or underclad cracks in forgings (RTMAX-FO). These values can be estimated based mostly on the information in the NRCs Reactor Vessel Integrity Database (RVID). The staff also recommends using these different RT values together to characterize the fracture resistance of the vessels beltline region, recognizing that the probability of a vessel fracture initiating from different flaw populations varies considerably in response to factors that are both understood and predictable. Correlations between these RT values and the through-wall cracking frequency attributable to different flaw populations show little plant-to-plant variability because of the general similarity of PTS challenges among plants.
An important element of the PTS plant-specific analysis is the calculation of the conditional probability of failure of the vessel by performing probabilistic fracture mechanics (PFM) analyses.
The term conditional refers here to the assumption that the specific PTS event under study has in fact occurred. Combined with an estimate of the frequency of occurrence for the event, a predicted frequency of vessel failure can then be calculated. OCA-P [12] and VISA-II [13] are PTS PFM computer programs, independently developed with NRC funding at Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL), respectively, in the 1980s that are currently referenced in Regulatory Guide 1.154 as acceptable codes for performing plant-specific analyses. There have also been other proprietary PTS PFM codes independently developed in the US and internationally by reactor vendors and laboratories. These codes perform PFM analyses, using Monte Carlo techniques, to estimate the increase in failure probability as the vessel accumulates radiation damage over its operating service life. The results of such analyses, when compared with the limit of acceptable failure probability, provide an estimate of the residual life of a reactor pressure vessel. Also results of such analyses can be used to evaluate the potential benefits of plant-specific mitigating actions designed to reduce the probability of reactor vessel failure, thus potentially extending the service life of the vessel [14].
Previous efforts at obtaining the same probabilistic solutions to a specified PTS problem using different PFM codes have met with varying degrees of success [15-17]. Experience with the application of OCA-P and VISA-II as well as advancements in the science of probabilistic risk assessment (PRA) over the past 15 years have provided insights into areas where the PTS PFM
6 methodology could be improved. The FAVOR (Fracture Analysis of Vessels - Oak Ridge) computer code was initially developed in the early 1990s [18] (see Fig. 2) in an effort to combine the best attributes of OCA-P and VISA-II. In the ensuing years, the NRC-funded FAVOR code has continued its advancement with the goal of providing a computational platform for incorporating additional capabilities and new developments in the fields of thermal hydraulics (as an input source to FAVOR),
deterministic and probabilistic fracture mechanics, and probabilistic risk assessment (PRA).
Fig. 2. Depiction of the development history of the FAVOR PFM code 1.2 PTS Re-Evaluation Project The NRC began the PTS Re-Evaluation Project in 1999 to develop a technical basis for a revised PTS rule within the framework established by modern probabilistic risk assessment techniques and advances in the technologies associated with the physics of PTS events. An updated computational methodology evolved through interactions between experts in the relevant disciplines (see Fig. 3) of thermal hydraulics, PRA, materials embrittlement, PFM, and inspection (flaw characterization). This updated methodology was implemented into the FAVOR code and applied in the PTS Re-evaluation Project to establish a technical basis that better informs the basis developed for the original PTS rule.
The PTS Re-evaluation was limited to performing analyses of Pressurized Water Reactors (PWRs) subjected to cool-down transients imposed on the inner (wetted) surface of the reactor pressure vessel.
As depicted in Fig. 3, FAVOR has continued to evolve with the objective of being applied to determine if a technical basis can also be established that better informs the basis of the then-existent PTS regulations (per ASME Code,Section XI, Appendix G) for normal operational transients such as those associated with reactor start-up (heat-up) and reactor shutdown (cool-down). Specifically, FAVOR has been generalized to meet this requirement, i.e., to be able perform risk-informed fracture analyses for heat-up and cool-down transients in Boiling Water Reactors (BWRs) as well as PWRs.
7 Fig. 3. The PTS Re-Evaluation Project incorporates advancements across a range of technical disciplines relevant to PTS assessment methodologies.
In support of the PTS Re-Evaluation Project, the following advanced technologies have been incorporated into FAVOR:
the ability to incorporate new detailed flaw-characterization distributions from NRC research (with Pacific Northwest National Laboratory, PNNL),
the ability to incorporate detailed neutron fluence maps, the ability to incorporate warm-prestressing effects into the analysis, the ability to include temperature-dependencies in the thermo-elastic properties of base and
- cladding, the ability to include crack-face pressure loading for surface-breaking flaws, the addition of a new ductile-fracture model simulating stable and unstable ductile tearing, the addition of a new embrittlement correlation, the ability to include multiple transients in one execution of FAVOR, the ability to include input from the Reactor Vessel Integrity Database, Revision 2, (RVID2) of relevant RPV material properties, the addition of new fracture-toughness models based on extended databases and improved statistical distributions, the addition of a variable failure criterion, i.e., how far must a flaw propagate into the RPV wall for the vessel simulation to be considered as failed ?
the addition of semi-elliptic surface-breaking and embedded-flaw models, the addition of through-wall weld stresses,
8 the addition of base material SIFIC(s) from the proposed ASME code,Section XI, Appendix A, Article A-3000, Method of KI Determination, for infinite and finite axial and 360 continuous and finite circumferential flaws into the FAVOR SIFIC database, and the implementation of improved PFM methodology that incorporates modern PRA procedures for the classification and propagation of input uncertainties and the characterization of output uncertainties as statistical distributions.
1.3 Overview - Structure and Organization of the FAVOR Code As shown in Fig. 4, FAVOR is composed of three computational modules: (1) a deterministic load generator (FAVLoad), (2) a Monte Carlo PFM module (FAVPFM), and (3) a post-processor (FAVPost). Figure 4 also indicates the nature of the data streams that flow through these modules.
Fig. 4. FAVOR data streams flow through three modules: (1) FAVLoad, (2) FAVPFM, and (3)
FAVPost.
The PFM model in FAVOR is based on the application of Monte Carlo techniques in which deterministic fracture analyses are performed on a large number of stochastically-generated RPV trials or realizations. Each vessel realization, containing a specified number of flaws, is analyzed to determine the conditional probability of initiation (CPI) and the conditional probability of failure
9 (CPF) for an RPV challenged by a postulated thermal-hydraulic transient at a selected time in the vessels operating history. The fracture-initiation mechanism is stress-controlled cleavage (in the lower transition-temperature region of the vessel material) modeled under the assumptions of linear-elastic fracture mechanics (LEFM), and the associated failure modes are sufficient flaw growth either to produce a net-section plastic collapse of the remaining ligament or to advance the crack tip to a user-specified fractional distance of the wall thickness. The potential for plane-strain crack arrest is also simulated. The time-dependent load path is assumed to be quasi-static.
A ductile-fracture capability has been implemented into the Initiation-Growth-Arrest (IGA) submodel to allow the simulation of flaw growth by stable ductile tearing in combination with cleavage propagation. When this user-selected option is turned on, an additional failure mode of unstable ductile tearing is included in the determination of CPF.
The Monte Carlo method involves sampling from appropriate probability distributions to simulate many possible combinations of flaw geometry and RPV material embrittlement, all exposed to the same transient loading conditions. The PFM analysis is performed for the beltline of the RPV, usually assumed to extend from one foot below the active length of the reactor core to one foot above the core. As shown in Fig. 5, the RPV beltline can be divided into major regions such as axial welds, circumferential welds, and plates or forgings that may have their own embrittlement-sensitive chemistries. These major regions may be further divided into subregions to accommodate detailed mappings of azimuthal and axial variations in fast-neutron fluence.
10 Fig. 5. The global modeling approach in FAVOR allows the entire beltline to be simulated in one model definition. (The above schematic is for a BWR.)
Fig. 6. Flaw models available in FAVOR.
11 Figure 6 shows the flaw models that are available in FAVOR:
A significant part of the generalization included in FAVOR is (1) the capability to model different flaw populations depending on the problem and (2) the capability to model BWR vessel geometries as well as PWR geometries.
FAVOR was originally developed to perform deterministic and probabilistic fracture mechanics (PFM) analyses of reactor pressure vessels subjected to cool-down thermal hydraulic transients imposed on the inner (wetted) surface of the reactor such as those associated with accidental PTS conditions and normal transients associated with reactor shutdown.
For such cool-down transients, the flaw populations of interest are those flaws on and/or near the inner surface of the reactor vessel wall, because at the inner surface, the temperature is at its minimum and the tensile stress and radiation-induced embrittlement are at their maximum. These tensile stresses tend to open existing cracks located on or near the internal surface of the RPV wall.
Therefore, earlier versions of FAVOR were limited to modeling internal surface-breaking flaws and/or embedded flaws that reside near the inner surface of the vessel wall. The embedded flaws (quantified in the embedded flaw characterization files) are assumed to be distributed uniformly throughout the entire vessel wall; however, for computational efficiency, only those postulated to reside in the first 3/8 of the base metal (wall thickness exclusive of clad thickness) were included in the analysis. For cool-down transients, the applied-KI driving force for embedded flaws postulated to reside in the vessel wall beyond the inner 3/8 of the wall thickness is too small to have a conditional probability of initiating an embedded flaw in cleavage fracture.
For heat-up transients, such as normal transients associated with reactor start-up, flaws on or near the external surface of the reactor vessel are the most vulnerable because the tensile stresses are at their maximum there. The FAVORHT code was designed to perform analyses of these heat-up transients; i.e., however, it was limited to the modeling of embedded flaws in the outer 3/8 of the RPV wall thickness. FAVORHT did not have the capability of modeling external surface-breaking flaws.
FAVOR, v9.1, consolidated the capabilities of the previous versions of FAVOR and FAVORHT as discussed above as well as added additional capabilities. FAVOR now has the user-specified optional ability to model three different flaw populations as follows:
12 Flaw Population Option 1 - (Identical to previous versions of FAVOR.) All surface-breaking flaws (quantified in the surface flaw characterization input file) are internal surface breaking flaws and only those embedded flaws in the first 3/8 of the RPV wall thickness are included in the model. The primary application of this option is for modeling cool-down transients. Through-wall flaw propa-gation is included in this option Flaw Population Option 2 - (Similar to previous versions of FAVORHT, however, it includes the capability to model external surface breaking flaws.) All surface-breaking flaws (quantified in the surface flaw characterization input file) are external surface-breaking flaws and those embedded flaws in the outer 3/8 of the RPV wall thickness are included in the model. The primary application of this option is for modeling heat-up transients. Through-wall flaw propagation is not included in this option, i.e., an initiated flaw is assumed to propagate thru-the-wall (thru the wetted inner surface) such that failure occurs. Therefore, the conditional probability of vessel failure is equal to the conditional probability crack initiation.
Flaw Population Option 3 - This additional population includes internal and external surface-breaking flaws; all of the embedded flaws are uniformly distributed through the RPV wall (approximately 8/3 times the number of embedded flaws postulated in Options 1 and 2). The number of postulated surface breaking flaws is double that of Options 1 or 2; and they are evenly divided between internal and external surface breaking flaws. The application of Option 3 is for modeling transients in which the pressure-induced loading is dominant (e.g., hydro-testing, etc.), since the applied-KI for all flaws has a smaller dependence on their respective locations. Also, it is anticipated that this option may be more appropriate for modeling BWRs since the pressure-induced applied-KI is larger for BWRs than for PWRs. Through-wall flaw propagation is not yet included in this option.
For flaw population option 3, internal surface breaking flaws and embedded flaws in the inner half of the RPV (category 2) will be incrementally propagated thru the wall to determine if the vessel fails.
External surface breaking flaws and embedded flaws in the outer half of the RPV (category 3) will not be propagated thru the wall, but rather, its is just assumed that they fail the vessel.
Flaw Population Options 1 and 2 are available for computational efficiency. If the dominant loading is thermally induced, only those populations of flaws on or near the relevant RPV surface would likely ever initiate (and subsequently fail), so the other flaws are excluded from the analysis because their presence would not change the PFM solution(s), but could dramatically increase the computational resources (memory and time) to complete a PFM analysis. When in doubt, Option 3 is
13 suggested; however, this option will require considerably more computational resources in terms of memory and computational time to reach a converged solution.
Another limitation of earlier versions of FAVOR is that the analysis of internal surface-breaking flaws was restricted to reactor vessels with an internal radius to wall thickness (Ri/t) ratio of approximately 10, characteristic of PWRs. This limitation was because the stress intensity factor-influence coefficients (SIFICs), applied by FAVOR to calculate values of applied-KI for surface-breaking flaws, were applicable only to this specific geometry. Most BWRs have an Ri/t ratio of approximately 20, although a few BWRs in the United States have an Ri/t ratio of approximately 15.
The SIFIC datasets for BWR vessel geometry (Ri/t 20) are distinctly different from those generated for the PWR geometry (Ri/t 10); therefore, there are two SIFIC datasets for each of the 16 surface breaking flaw types in FAVOR; one each for PWR geometry Ri/t 10 and BWR geometry Ri/t 20.
The generalization of FAVOR to include the capability to calculate applied-KI s for the 16 axially-and circumferentially-oriented internal and external surface breaking flaw types for both BWR and PWR required the creation, implementation, and verification of a total 32 SIFIC databases, compared to eight SIFIC datasets in previous versions of FAVOR. Also, algorithms have been developed and verified such that the SIFIC datasets for Ri/t 10 and BWR geometry Ri/t 20 for internal and external surface-breaking flaws are appropriately interpolated for application to RPVs for which 10 < Ri/t < 20; therefore, FAVOR can be also be applied to those BWRs in the United States that have an Ri/t ratio of approximately 15.
Regarding flaw orientation, consistent with previous versions of FAVOR, all inner-surface breaking flaws are assumed to be circumferentially oriented. External surface-breaking flaws in axial welds are axially oriented; external surface-breaking flaws in circumferential welds are circumferentially oriented; and external surface-breaking flaws in plates are evenly divided between axial and circumferential orientations. As in previous versions of FAVOR, embedded flaws in welds assume the orientation of the weld, i.e., embedded flaws in axial welds are axially oriented, and embedded flaws in circumferential welds are circumferentially oriented. Embedded flaws in plates are evenly divided between axial and circumferential orientations.
For the finite-length semielliptical flaw geometries, the SIFIC datasets contain values corresponding to multiple angular positions around the semielliptical crack front; however, currently FAVOR only applies those values that correspond to the deepest point of the flaw. The code could be further generalized to have the capability to calculate the applied-KI at multiple locations around the crack front.
14 It is anticipated that this generalized version of FAVOR will be instrumental in addressing the wide range of vessel geometries and transient types required in the current on-going NRC/industry study to determine if a risk-informed technical basis can be established to improve the current regulations for normal transients associated with reactor start-up and shutdown The flaw models shown in Fig. 6 are included in the three categories of flaws identified by FAVOR:
Category 1:
Includes Flaw Population Option 1 - internal surface-breaking flaws only (flaw types 1-8)
Includes Flaw Population Option 2 - external surface-breaking flaws only (flaw types 9-16)
Includes Flaw Population Option 3 - internal and external surface-breaking flaws only (flaw types 1-
- 16)
15 Category 2:
Includes Flaw Population Option 1 with embedded flaws having fully elliptic geometry with the crack tip nearest the wetted inner surface located between the clad / base interface and the inner 1/8th of the base metal thickness Includes Flaw Population Option 2 with embedded flaws having fully elliptic geometry with crack tip nearest the external surface located in the outer 1/8th of the base metal thickness Includes Flaw Population Option 3 with embedded flaws having fully elliptic geometry with crack tip nearest the external surface located between the clad base interface and the outer half of the total wall thickness.
Note: base metal thickness = total vessel wall thickness - clad thickness Category 3:
Includes Flaw Population Option 1 with embedded flaws having fully elliptic geometry with the crack tip nearest the wetted inner surface located between 1/8th and 3/8th of the base metal thickness ;
Includes Flaw Population Option 2 with embedded flaws having fully elliptic geometry with crack tip nearest the external surface located between 1/8th and 3/8th of the outer base metal thickness ;
Includes Flaw Population Option 3 with embedded flaws having fully elliptic geometry with crack tip nearest the external surface located in the outer half of the total wall thickness.
Away from nozzles and other geometric discontinuities in the vessel, the RPV wall experiences a biaxial stress state during an overcooling event in which the principal stresses are oriented in both the longitudinal (axial stresses) and azimuthal (hoop stresses) directions. FAVOR, therefore, provides the capability for the crack face to be oriented normal to either of the two opening-mode principal directions, i.e., axial stresses opening circumferential flaws and hoop stresses opening axial flaws. In addition to the combined states of mechanical loading due to internal pressure, thermal loading due to differential expansion between the cladding and base, crack-face pressure loading on surface-breaking flaws, and through-wall thermal stress loading due to temperature gradients in the cladding and base, FAVOR also provides the option to include the effects of residual stresses in axial and circumferential welds for all of the flaw models.
The format of the required user-input data files will be discussed in detail in the following sections. In summary, the input files along with the resulting output files for the three modules are:
16 FAVLoad Data Streams (see Fig. 7)
- 1) Input file that includes: vessel geometry, thermo-mechanical material properties for the cladding and base (either constant or temperature dependent), user-selected loading options, and thermal-hydraulic definitions of all transients to be analyzed
- 2) Output file that provides an echo of the user input
- 3) Output file that is used as a load-definition input file for FAVPFM FAVPFM Data Streams (see Fig. 8)
- 4) Input file that provides user-selected case options, major region and subregion definitions with weld/plate embrittlement data, and the number of RPV realizations/trials to be simulated
- 5) Input file from the FAVLoad module [data stream file 3)] that contains load-definition data for each thermal-hydraulic transient
- 6) Input file that provides characterization data for surface-breaking flaws in plates, forgings, and welds
- 7) Input file that provides characterization data for flaws embedded in welds
- 8) Input file that provides characterization data for flaws embedded in plates and forgings
- 9) Input file for restart cases (required only if the current execution is a restart from a previous run)
- 10) Output file that provides an echo of the user input
- 11) Output/Input binary restart file, created at user-selected checkpoints during the FAVPFM run
- 12) Output file that contains summary reports of the PFM analysis
- 13) Output files that can be used for Quality Assurance checks of PFM calculations
- 14) Output file with the conditional probability of crack initiation matrix for input to FAVPost
- 15) Output file with the conditional probability of through-wall cracking matrix for input to FAVPost
17 Fig. 7. The FAVOR load generator module FAVLoad performs deterministic analyses for a range of thermal-hydraulic transients.
Fig. 8. The FAVPFM module takes output from FAVLoad and user-supplied data on flaw distributions and embrittlement of the RPV beltline and generates PFMI (INITIATE.DAT) and PFMF (FAILURE.DAT) arrays.
18 Fig. 9. The FAVOR post-processor FAVPost combines the distributions of conditional probability of initiation and failure calculated by FAVPFM with initiating frequency distributions for all of the transients under study to create distributions of frequencies of RPV fracture and failure.
FAVPost Data Streams (see Fig. 9)
- 16) Input file that provides initiating frequency distributions for each transient defined in 1) above.
- 17) Input file from FAVPFM containing the conditional probability of initiation matrix
- 18) Input file from FAVPFM containing the conditional probability of failure matrix
- 19) Output file that, in addition to an echo of the user input, contains histograms describing the distributions for the frequency of crack initiation and frequency of failure (also known as the through-wall crack frequency) with the units of cracked vessels per reactor operating year and failed vessels per reactor operating year, respectively.
1.4 Installation All of the files required to run FAVOR including executables, example input and output files, documentation, and source code, are distributed in a WINZIP file. Using the WINZIP utility application, these files can be unzipped to the users local directory. The contents of this WINZIP file are shown in Fig. 10.
19 Fig. 10. Contents of the FAVOR WINZIP package file.
20 1.5 Execution On Microsoft Windows operating systems (Windows XP/VISTA/7/10), the three FAVOR modules can be started either by double clicking on the executables icon (named FAVLoad.exe, FAVPFM.exe, and FAVPost.exe) in Windows Explorer or by opening a Command Prompt window and typing in the name of the executable at the line prompt as shown in Fig. 11a for FAVLoad execution. All input files and executables must reside in the same current working directory. For details on the creation of FAVOR input files see Chapter 2. In Fig. 11b, the code prompts for the names of the FAVLoad input and FAVLoad output files. The FAVLoad output file will be used as the load-definition input file for the FAVPFM module. Figure 12 shows the messages written to the screen as FAVLoad performs its calculations.
Upon creation of the load-definition file by FAVLoad, FAVPFM execution can be started by typing FAVPFM at the line prompt (see Fig. 13). FAVPFM will then prompt the user for the names of six files (see Fig. 14a): (1) the FAVPFM input file, (2) load-definition file output from FAVLoad, (3) a name for the output file to be created by FAVPFM, (4) the name of the input flaw-characterization file for surface-breaking flaws in weld and plate regions (DEFAULT=S.DAT), (5) the name of the flaw-characterization file for embedded flaws in weld regions (DEFAULT=W.DAT), and (6) the name of the flaw-characterization file for embedded flaws in plate regions (DEFAULT=P.DAT). The user can accept the default file names for input files (4)-(6) by hitting the ENTER key at the prompt.
If FAVPFM cannot find the named input files in the current execution directory, it will prompt the user for new file names. If the FAVPFM output file to be created already exists in the current directory, the code will query the user if it should overwrite the file. For RESTART cases, the user will be prompted for the name of a binary restart file created during a previous execution (see Fig. 14b). See Sect. 2.2, Record 1 - CNT1, for detailed information on the execution of restart cases.
The user may abort the execution at any time by typing a <ctrl>c. FAVPFM provides monitoring information during execution by writing the running averages of conditional probabilities of initiation and vessel failure for all of the transients defined in the load file for each RPV trial as shown in Fig. 15.
21 (a)
(b)
Fig. 11. Execution of the FAVLoad module: (a) type in FAVLoad at the line prompt and (b) respond to prompts for the input and output file names.
22 Fig. 12. FAVLoad calculates thermal, stress, and applied KI loading for all of the transients defined in the input file.
Fig. 13. Type FAVPFM at the Command Prompt to begin execution of the FAVPFM module.
23 Fig. 14. (a) FAVPFM prompts for the names of the (1) FAVPFM input file, (2) FAVLoad-generated load-definition file, (3) FAVPFM output file, (4) flaw-characterization file for surface-breaking flaws in welds and plates, (5) flaw-characterization file for embedded flaws in welds, and (6) flaw-characterization file for embedded flaws in plates.
24 Fig. 14. (b) For a restart case, FAVPFM will also prompt for the binary restart file created in a previous execution (see Record 1 - CNT 1 for details regarding restart cases).
25 Fig. 15. FAVPFM continually writes out progress reports in terms of running average CPI/CPF values for each transient as the code proceeds through the required number of RPV trials.
26 FAVPost Execution - The FAVPost module may be run while FAVPFM is still executing. This feature is particularly helpful when FAVPFM is executing a run that could take hours or possibly days. Here is the procedure:
- 1. While FAVPFM is running in one Command Prompt Window, bring up a second Command Prompt Window and navigate to a directory that is not the FAVOR working directory.
- 2. Copy the FAVPost.exe executable and the current files INITIATE.DAT, FAILURE.DAT, and NSIM.DAT from the current FAVOR working directory to the directory selected in Step 1.
- 3. Start the copied FAVPost executable in the directory selected in Step 1 by typing FAVPost and then <Enter> at the prompt.
- 4. Respond to the prompt for the FAVPost input filename.
- 5. Take the defaults for the INITIATE.DAT and FAILURE.DAT file names by hitting the <Enter>
key twice.
- 6. Respond to the prompt for the FAVPost output file name.
- 7. Respond to the prompt for the number of RPV trials to be processed.
- 8. FAVPost will interrogate the INITIATE.DAT file to determine the current number of completed RPV trials.
- 9. FAVPost reports the number of RPV trials completed and asks how many trials the user wishes to process.
- 10. Respond to the query with either a number (less than the total completed) or take the default ALL by hitting the <Enter> key.
The above capability is also convenient for calculating convergence statistics as a function of RPV trials, even when the FAVPFM run has completed. For example, the analyst might wish to calculate the 99th percentile of the failure frequency vs RPV trials as a check for convergence. Just run FAVPost several times asking for 1000, 2000, 3000, NSIM RPV trials, and then plot the relevant statistics.
In Fig. 16, FAVORs post-processing module is executed by typing FAVPost at the line prompt. The code will then prompt the user for the names of four files (see Fig. 16): (1) a FAVPost input file, (2) the file created by the FAVPFM execution that contains the conditional probability of initiation matrix (DEFAULT=INITIATE.DAT), (3) the file created by the FAVPFM execution that contains the conditional probability of failure matrix (DEFAULT=FAILURE.DAT), and (4) the name of the output file to be created by FAVPost that will have the histograms for vessel fracture and failure frequencies. Again, for files (2) and (3), the user may accept the defaults by hitting the RETURN/ENTER key.
27 Fig. 16(a). Type in FAVPost at the Command Prompt to execute the FAVPost module.
FAVPost prompts for the (1) FAVPost input file, (2) CPI matrix file generated by FAVPFM, (3) CPF matrix file generated by FAVPFM, and (4) the FAVPost output file.
28 Fig. 16(b) Set the total number of simulations to be processed and build convergence tables, if required.
29 1.6 Distribution WINZIP package file The distribution WINZIP file, FAVOR_v16.1_distribution.zip, contains the following folders and files:
Main Folder:.\\FAVOR_v16.1\\
The main folder.\\FAVOR_v16.1\\ contains five subfolders. After installation, the FAVOR, v16.1, documentation may be viewed by double-clicking on the individual.pdf files in the \\docs\\
subfolder if a PDF Reader application has been associated with the PDF extension on the users computer.
30 Subfolder:.\\FAVOR_v16.1\\bin\\
.\\FAVOR_v16.1\\bin contains the executables for a PC running under a Microsoft Windows operating system.
Subfolder:.\\FAVOR_v16.1\\doc\\
.\\FAVOR_v16.1\\doc contains the Theory and Users Guide in PDF.
31 Subfolder:
.\\FAVOR_v16.1\\Examples\\User_Guide_Deterministic_Example_Problems\\Thru_Wall\\Surface Breaking_Flaws\\Cooldown\\
Subfolder:
.\\FAVOR_v16.1\\Examples\\User_Guide_Deterministic_Example_Problems\\Thru_Wall\\Surface Breaking_Flaws\\Heatup\\
32 Subfolder:
.\\FAVOR_v16.1\\Examples\\User_Guide_Deterministic_Example_Problems\\Time_Histories\\
Embedded Flaws\\Cooldown Subfolder:
.\\FAVOR_v16.1\\Examples\\User_Guide_Deterministic_Example_Problems\\Time_Histories\\
Embedded Flaws\\ Heatup
33 Subfolder:
.\\FAVOR_v16.1\\Examples\\User_Guide_Deterministic_Example_Problems\\Time_Histories\\
Surface_Breaking_Flaws\\Cooldown Subfolder:
.\\FAVOR_v16.1\\Examples\\User_Guide_Deterministic_Example_Problems\\Time_Histories\\
Surface_Breaking_Flaws\\Heatup
34 Subfolder:.\\FAVOR_v16.1\\Examples\\User_Guide_PFM_Example_Problems\\
These are the deterministic and PFM input and output files for the example case discussed in Chapter 3 of this Users Guide.
Subfolder: FAVOR_v16.1\\flaw data
35 The four flaw-characterization files developed for the PTS Re-Evaluation Project are included in this subfolder for each of four nuclear power plants. The files Palisades.zip (Palisades NPP, South Haven, MI), Oconee.zip (Oconee NPP, Greeneville, SC), CalvertCliffs.zip (Calvert Cliffs NPP, Annapolis, MD), and BeaverValley.zip (Beaver Valley NPP, McCandless, PA) are zipped file archives containing the four plant-specific flaw-characterization files. The files W.dat, S.dat, and P.dat are the example files used in the installation examples.
Subfolder: FAVOR_v16.1\\src\\
The source code for the three FAVOR modules is included in this subfolder. FAVOR is written in the Fortran computer language. A Fortran compiler that is compliant with the Fortran 90/95 standard (ISO/IEC 1539-1:1997) is required to compile the FAVOR source code.
36
- 2. FAVOR Input Requirements FAVOR employs ASCII text files either created by the user or created by previous executions of the FAVOR modules. User-created input files are organized by a sequence of keyword records with free-field format for the placement of parameter data located on the same line record as the keyword or on data lines following the keyword record. The data must be input exactly in the sequence and order prescribed in the sections below. Omission of data fields is not allowed. The 4-letter keywords always begin in column 1.
Comment lines are designated by an asterisk, *, in column 1. The user is encouraged to take full advantage of including comments in the input files as a method for internal documentation of the model. It has proven beneficial by the developers of FAVOR to use the input files (included in the example cases in the distribution package) as templates for the creation of new input datasets.
In developing input datasets, the user should pay careful attention to the required units for each data record. FAVOR carries out conversions internally to insure a consistent set of units for all analyses; however, the input data must be entered in the units specified in the sections below.
2.1 FAVOR Load Module - FAVLoad A total of 12 data records, listed in Table 1, are required in the FAVLoad input file, where each record may involve more than one line of data. A detailed description of each data record is given below.
37 Table 1. Record Keywords and Parameter Fields for FAVLoad Input File 1
GEOM IRAD=[in]
W=[in]
CLTH=[in]
2 BASE K=[Btu/hr-ft-°F] C=[Btu/lbm-°F]
RHO=[lbm/ft3]
E=[ksi]
ALPHA=[°F -1]
NU=[-]
NTE=[0l1]
2a NBK NK=[-]
if NTE=1 input NK data lines with {T, K(T) } [°F, Btu/h-ft-°F] pairs - one pair per line 2b NBC NC=[-]
if NTE=1 input NC data lines with {T, C(T) } [°F, Btu/lbm-°F] pairs - one pair per line 2c NBE NE=[-]
if NTE=1 input NE data lines with {T, E(T) } [°F, ksi] pairs - one pair per line 2d NALF NA=[-]
Tref0=[°F]
if NTE=1 input NA data lines with {T, ALPHA(T) } [°F, °F -1] pairs - one pair per line 2e NNU NU=[-]
if NTE=1 input NU data lines with {T, NU(T) } [°F, - ] pairs - one pair per line 3
CLAD K=[Btu/hr-ft-°F] C=[Btu/lbm-°F]
RHO=[lbm/ft3]
E=[ksi]
ALPHA=[°F-1]
NU=[-]
NTE=[0l1]
3a NCK NK=[-]
if NTE=1 input NK data lines with {T, K(T) } [°F, Btu/h-ft-°F] pairs - one pair per line 3b NCC NC=[-]
if NTE=1 input NC data lines with {T, C(T) } [°F, Btu/lbm-°F] pairs - one pair per line 3c NCE NE=[-]
if NTE=1 input NE data lines with {T, E(T) } [°F, ksi] pairs - one pair per line 3d NALF NA=[-]
Tref0=[°F]
if NTE=1 input NA data lines with {T, ALPHA(T) } [°F, °F -1] pairs - one pair per line 3e NNU NU=[-]
if NTE=1 input NU data lines with {T, NU(T) } [°F, - ] pairs - one pair per line 4
SFRE T=[°F]
CFP=[0l1]
5 RESA NRAX=[-]
6 RESC NRCR=[-]
7 TIME TOTAL=[min]
DT=[min]
8 NPRA NTRAN=[-]
Repeat data records 9 through 12 for each NTRAN transients 9
TRAN ITRAN=[-]
ISEQ=[-]
10 NHTH NC=[-]
input NC data lines with { t, h (t ) } [min, Btu/hr-ft2-°F] pairs - one pair per line 11 NTTH NT=[-]
input NT data lines with ( t, T (t ) ) [min, °F] pairs - one pair per line or 11 NTTH NT=101 STYL TINIT=[°F]
TFINAL=[°F]
BETA=[min-1]
12 NPTH NP=[-]
input NP data lines with ( t, P (t ) ) [min, ksi] pairs - one pair per line
38 Record 1 - GEOM Record No. 1 inputs vessel geometry data, specifically the internal radius, IRAD, in inches, the wall thickness (inclusive of cladding), W, in inches, and the cladding thickness, CLTH, in inches. The thickness of the base metal is, therefore, W - CLTH.
EXAMPLE
- ==================== *
- Record GEOM *
- ==================== *
- IRAD = INTERNAL RADIUS OF PRESSURE VESSEL [IN] *
- W = THICKNESS OF PRESSURE VESSEL WALL (INCLUDING CLADDING) [IN] *
- CLTH = CLADDING THICKNESS [IN]
- GEOM IRAD=78.5 W=8.031 CLTH=0.156 Records 2 and 3-BASE and CLAD Records 2 and 3 input thermo-elastic property data for the base (typically a ferritic steel) and cladding (typically an austenitic stainless steel), respectively: thermal conductivity, K, in Btu/hr-ft-F, C, mass-specific heat capacity in Btu/lbm-F, mass density, RHO, in lbm/ft3, Youngs modulus of elasticity, E, in ksi, coefficient of thermal expansion, ALPHA, in F-1, and Poissons ratio, NU. All property data are assumed to be independent of temperature if NTE = 0.
EXAMPLE
- =========================== *
- Records BASE and CLAD *
- =========================== *
- THERMO-ELASTIC MATERIAL PROPERTIES FOR BASE AND CLADDING *
- K = THERMAL CONDUCTIVITY [BTU/HR-FT-F] *
- C = SPECIFIC HEAT [BTU/LBM-F] *
- RHO = DENSITY [LBM/FT**3] *
- E = YOUNG'S ELASTIC MODULUS [KSI] *
- ALPHA = THERMAL EXPANSION COEFFICIENT [F**-1] *
- NU = POISSON'S RATIO [-] *
- NTE = TEMPERATURE DEPENDANCY FLAG *
- NTE = 0==> PROPERTIES ARE TEMPERATURE INDEPENDENT (CONSTANT) *
- NTE = 1==> PROPERTIES ARE TEMPERATURE DEPENDENT *
- IF NTE EQUAL TO 1, THEN ADDITIONAL DATA RECORDS ARE REQUIRED
- BASE K=24.0 C=0.120 RHO=489.00 E=28000 ALPHA=.00000777 NU=0.3 NTE=0 CLAD K=10.0 C=0.120 RHO=489.00 E=22800 ALPHA=.00000945 NU=0.3 NTE=0
39 If NTE = 1 on Records 2 or 3, then tables of temperature-dependent properties will be input.
EXAMPLE
- =========================== *
- Records BASE and CLAD *
- =========================== *
- THERMO-ELASTIC MATERIAL PROPERTIES FOR BASE AND CLADDING *
- K = THERMAL CONDUCTIVITY [BTU/HR-FT-F] *
- C = SPECIFIC HEAT [BTU/LBM-F] *
- RHO = DENSITY [LBM/FT**3] *
- E = YOUNG'S ELASTIC MODULUS [KSI] *
- ALPHA = THERMAL EXPANSION COEFFICIENT [F**-1] *
- NU = POISSON'S RATIO [-] *
- NTE = TEMPERATURE DEPENDANCY FLAG *
- NTE = 0==> PROPERTIES ARE TEMPERATURE INDEPENDENT (CONSTANT) *
- NTE = 1==> PROPERTIES ARE TEMPERATURE DEPENDENT *
- IF NTE EQUAL TO 1, THEN ADDITIONAL DATA RECORDS ARE REQUIRED
- BASE K=24.0 C=0.120 RHO=489.00 E=28000 ALPHA=.00000777 NU=0.3 NTE=1
- THERMAL CONDUCTIVITY TABLE NBK NK=16 70 24.8 100 25.0 150 25.1 200 25.2 250 25.2 300 25.1 350 25.0 400 25.1 450 24.6 500 24.3 550 24.0 600 23.7 650 23.4 700 23.0 750 22.6 800 22.2
- SPECIFIC HEAT TABLE NBC NC=16 70 0.1052 100 0.1072 150 0.1101 200 0.1135 250 0.1166 300 0.1194 350 0.1223 400 0.1267 450 0.1277 500 0.1304 550 0.1326 600 0.1350 650 0.1375 700 0.1404 750 0.1435 800 0.1474
- YOUNG'S MODULUS TABLE NBE NE=8 70 29200
40 200 28500 300 28000 400 27400 500 27000 600 26400 700 25300 800 23900
- COEFF. OF THERMAL EXPANSION
- ASME Sect. II, Table TE-1
- Material Group D, pp. 580-581 NALF NA=15 Tref0=70 100 0.00000706 150 0.00000716 200 0.00000725 250 0.00000734 300 0.00000743 350 0.00000750 400 0.00000758 450 0.00000763 500 0.00000770 550 0.00000777 600 0.00000783 650 0.00000790 700 0.00000794 750 0.00000800 800 0.00000805
- POISSON'S RATIO NBNU NU=2
- 0. 0.3 1000. 0.3 CLAD K=10.0 C=0.120 RHO=489.00 E=22800 ALPHA=.00000945 NU=0.3 NTE=1
- THERMAL CONDUCTIVITY TABLE NK N=16 70 8.1 100 8.4 150 8.6 200 8.8 250 9.1 300 9.4 350 9.6 400 9.9 450 10.1 500 10.4 550 10.6 600 10.9 650 11.1 700 11.4 750 11.6 800 11.9
- SPECIFIC HEAT TABLE NC N=16 70 0.1158 100 0.1185 150 0.1196 200 0.1208 250 0.1232 300 0.1256 350 0.1258 400 0.1281 450 0.1291 500 0.1305 550 0.1306 600 0.1327 650 0.1335 700 0.1348 750 0.1356 800 0.1367
41
- YOUNG'S MODULUS TABLE NE N=3 68 22045.7 302 20160.2 482 18419.8
- COEFF. OF THERMAL EXPANSION
- ASME Sect. II, Table TE-1
- Material Group - 18Cr-8Ni pp. 582-583 NALF N=15 Tref0=70 100 0.00000855 150 0.00000867 200 0.00000879 250 0.00000890 300 0.00000900 350 0.00000910 400 0.00000919 450 0.00000928 500 0.00000937 550 0.00000945 600 0.00000953 650 0.00000961 700 0.00000969 750 0.00000976 800 0.00000982
- POISSON'S RATIO NNU N=2
- 0. 0.3 1000. 0.3 The following sources were consulted to develop the temperature-dependent tables shown above:
Base Steel ASME Boiler and Pressure Vessel Code - Sect. II., Part D: Properties (1998) [19]
thermal conductivity - Table TCD - Material Group A - p. 592 thermal diffusivity - Table TCD - Material Group A - p. 592 Youngs Modulus of Elasticity - Table TM Material Group A - p. 606 Coefficient of Expansion - Table TE Material Group D - p. 580-581 Density = 489 lbm/ft3 Cladding ASME Boiler and Pressure Vessel Code - Sect. II., Part D: Properties (1998) [19]
thermal conductivity - Table TCD - High Alloy Steels - p. 598 thermal diffusivity - Table TCD - High Alloy Steels - p. 598 Youngs Modulus of Elasticity - NESC II Project - Final Report - p. 35 [20]
Coefficient of Expansion - Table TE High Chrome Steels - p. 582-583 Density = 489 lbm/ft3
42 Methods for Interpolation within Property Look-Up Tables FAVLoad constructs monotone piecewise cubic Hermite interpolants [21-23] for interpolation within the temperature-dependent property look-up tables. The following provides a summary of this interpolation procedure.
Monotone Piecewise Cubic Interpolation Algorithm The procedure assumes that the data to be interpolated are at least locally monotone, either monotonically increasing or decreasing. We begin by letting 1
2 n
a x
x x
b
be a partition of the interval
I a b
, and let
1,2, if i
n
be a given set of monotone data values at the partition points (knots); i.e., we assume that either
1 1,2, 1
i i
f f
i n
or
1 1,2, 1
i i
f f
i n
. Construct on a piecewise cubic function
1 p x I
such that
1,2, i
i p x f
i n
(1) and p x is monotone, and within each subinterval
1 i
i i
I x x
p x is a cubic polynomial represented by
1 1
2 3
1 4
i i
i i
p x f H x
f H
x d H x
d H
x
(2) where
j j
d p x
1 j
i i
are the derivatives of f at the knots, and
k H
x are cubic Hermite basis functions for the interval Ii with the form
1 1
2 1
3 4
1 2
3 3
2 where 3
2 i
i i
i i
i i
i i
i i
i i
x x
x x
H x
H x
h h
x x
x x
H x
h H
x h
h h
h x
x t
t t
t t
t
(3)
A method for estimating the derivatives,
j j
d p
x
at the knots is given in ref. [22]. Let
1 1
i i
i i
i f
f x
x
and as above 1
i i
i h
x x
, then
43
1 1,
1, 1
i i
i i
i d
G h
h i
n
(4) where the G-function is defined by
1 1
1 1
1 1
1 if 0
1 0
otherwise, and 2
3 i
i i
i i
i i
i i
i i
i i
i G
h h
h h
h h
(5)
The above algorithm has been coded into Fortran in the open source PCHIP [21] numerical package, available from the netlib.org repository, and implemented into FAVLoad.
Treatment of Thermal Expansion Coefficient Data As discussed in ref. [2], the thermal expansion coefficient data available in the ASME BPV Code, Sect. II, Part D, include both the instantaneous coefficient of linear thermal expansion, T
, (or thermal expansivity) at a specified temperature T and the mean coefficient of linear thermal expansion,
(
, )
ref T
T
, where the two are related by:
0 0
(
, )
1
(
)
ref ref T
T T
T ref T
dT T
T
(6)
For the implementation in FAVLoad, the correct data input should be the mean coefficient of linear thermal expansion. Values for 0
(
, )
ref T
T
were obtained from Table TE-1 of the ASME Code, Sect. II, Part D, Material Group D (includes A533B) and High Alloy Steels (includes SS304). When temperature-dependency is included in the thermal stress analysis, FAVLoad requires expansion coefficient data to be input that define the total thermal expansion from a specified reference temperature, Tref0. With 0
(
, )
ref T
T
data from handbook sources, this reference temperature is typically at room temperature and must be input in F on the NALF data card, for example, Tref0=70.
Record 4 - SFRE Record 4 inputs the thermal stress-free temperature for both the base and cladding in F. In addition, crack-face pressure loading on surface-breaking flaws can be applied with CFP = 1. If CFP = 0, then
44 no crack-face pressure loading will be applied. The derivation of the recommended value of 488 °F is discussed in ref. [2].
EXAMPLE
- ==================== *
- Record SFRE *
- ==================== *
- T = BASE AND CLADDING STRESS-FREE TEMPERATURE [F] *
- CFP = crack-face pressure loading flag *
- CFP = 0==> no crack-face pressure loading *
- CFP = 1==> crack-face pressure loading applied
- SFRE T=488 CFP=1 Records 5 and 6 - RESA and RESC Records 5 and 6 set weld residual stress flags, NRAX and NRCR, for axial and circumferential welds, respectively. If NRAX or NRCR are set to a value of 101, then weld residual stresses will be included in the FAVLoad output file. If NRAX or NRCR are set to a value of 0, then weld residual stresses will not be included in the FAVLoad output file.
EXAMPLE
- ========================= *
- Records RESA AND RESC *
- ========================= *
- SET FLAGS FOR RESIDUAL STRESSES IN WELDS *
- NRAX = 0 AXIAL WELD RESIDUAL STRESSES OFF *
- NRAX = 101 AXIAL WELD RESIDUAL STRESSES ON *
- NRCR = 0 CIRCUMFERENTIAL WELD RESIDUAL STRESSES OFF *
- NRCR = 101 CIRCUMFERENTIAL WELD RESIDUAL STRESSES ON
- RESA NRAX=101 RESC NRCR=101 Record 7 - TIME Record 7 inputs the total elapsed time, TIME, in minutes for which the transient analysis is to be performed and the time increment, DT, also in minutes, to be used in the time integration in FAVPFM. Internally, the FAVLoad module uses a constant time step of 1.0 second to perform finite-element through-wall heat-conduction analyses (1D axisymmetric).
45 EXAMPLE
- ========================= *
- Record TIME *
- ========================= *
- TOTAL = TIME PERIOD FOR WHICH TRANSIENT ANALYSIS IS TO BE PERFORMED [MIN]*
- DT = TIME INCREMENT [MIN]*
TIME TOTAL=80.0 DT=0.5 DT is the time-step size for which load results (temperatures, stresses, etc.) are saved during execution of the FAVLoad module; therefore, DT is the time-step size that will be used for all fracture analyses in subsequent FAVPFM executions. Some testing with different values of DT is typically necessary to insure that a sufficiently small value is used that will capture the critical characteristics of the transients under study. Note that there is no internal limit to the size of the time step; however, the computational time required to perform a PFM analysis is inversely proportional to DT.
Record 8 - NPRA Record 8 inputs the number of thermal-hydraulic transients, NTRAN, to be defined for this case. The following Records 9 through 12 should be repeated for each of the NTRAN transients to be defined.
EXAMPLE
- =============== *
- Record NPRA *
- =============== *
- NTRAN = NUMBER OF TRANSIENTS TO BE INPUT [-]
- NPRA NTRAN=4 Record 9 - TRAN Record 9 provides a mechanism for cross-indexing the internal FAVOR transient numbering system with the initiating-event sequence numbering system used in the thermal-hydraulic analyses that were performed to develop input to FAVOR. The internal FAVOR transient number, ITRAN, is linked with the thermal-hydraulic initiating-event sequence number, ISEQ, with this record. Whereas, the value of ITRAN will depend upon the arbitrary ordering of transients in the FAVLoad transient input stack, the value of ISEQ is a unique identifier for each transient. ITRAN begins with 1 and is incremented by 1 up to NTRAN transients.
46 EXAMPLE
- ========================= *
- Record TRAN *
- ========================= *
- ITRAN = PFM TRANSIENT NUMBER *
- ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER
- TRAN ITRAN= 1 ISEQ=7 TRAN ITRAN= 2 ISEQ=9 TRAN ITRAN= 3 ISEQ=56 TRAN ITRAN= 4 ISEQ=97 Record 10 - NHTH Record 10 inputs the time history table for the convective film coefficient boundary conditions. There are NC data pairs of time,, in minutes and film coefficient, h, in Btu/hr-ft2-F entered following the NHTH keyword record line. The number of data pairs is limited only by the memory capacity of the computer. The film coefficient, ( )
h, is used in imposing a Robin forced-convection boundary condition at the inner vessel wall, Ri, defined by,
(, )
( )
( )
(, ) for 0
wall i
q R h
T T
R R
R
where q (R,) is the heat flux in Btu/hr-ft2,
T
is the coolant temperature near the RPV wall in F, and
wall T
R is the wall temperature in F.
EXAMPLE
- ========================= *
- Record NHTH *
- ========================= *
- CONVECTIVE HEAT TRANSFER COEFFICIENT TIME HISTORY *
- NC = NUMBER OF (TIME,h) RECORD PAIRS FOLLOWING THIS LINE *
- (CAN INPUT UP TO 1000 PAIRS OF t,h(t) data records
- NHTH NC=2
- =====================================
- TIME [MIN] h[BTU/HR-FT**2-F]
- =====================================
- 0. 500.
120. 500.
47 Record 11 - NTTH Record 11 inputs the time history definition for the coolant temperature,
( )
T
, which is applied in the Robin boundary condition discussed above. The time history can take two forms depending on the value of the NT parameter. If NT is equal to an integer other than 101, then an ordered table with NT lines of time,, in minutes and temperature, T, in F data pairs will follow the NTTH keyword record. The number of data pairs is limited only by the memory capacity of the computer. If NT = 101, then a stylized exponentially decaying time history will be used where the parameters are the initial coolant temperature, TINIT, in F, the asymptote for the coolant temperature, TFINAL, decay curve in F, and the decay time constant, BETA, in minutes-1. These parameters define the time history of the coolant temperature by the following equation:
( )
(
)exp(
)
FINAL INIT FINAL T
T T
T
EXAMPLES
- ========================= *
- Record NTTH *
- ========================= *
- THERMAL TRANSIENT: COOLANT TEMPERATURE TIME HISTORY *
- NT = NUMBER OF (TIME,TEMPERATURE) DATA PAIRS *
- (CAN INPUT UP TO 1000 PAIRS OF t,T (t) data records
- NTTH NT=12
- =============================
- TIME[MIN] T (t)[F]
- =============================
0.0 550.0 2.0 469.0 5.0 412.0 7.0 361.0 11.0 331.0 16.0 300.0 29.0 260.0 45.0 235.0 63.0 217.0 87.0 205.0 109.0 199.0 120.0 190.0 or
- ========================= *
- Record NTTH *
- ========================= *
- THERMAL TRANSIENT: COOLANT TEMPERATURE TIME HISTORY *
- NT = 101==> STYLIZED EXPONENTIAL DECAYING COOLANT TEMPERATURE *
- TINIT = INITIAL COOLANT TEMPERATURE (at time=0) (F) *
- TFINAL = LOWEST TEMPERATURE IN TRANSIENT (F) *
- BETA = DECAY CONSTANT (MIN**-1) *
- FAVLoad CALCULATES AND STORES THE COOLANT TEMPERATURE AT *
- 100 EQUALLY-SPACED TIME STEPS ACCORDING TO THE RELATION *
- T (t) = T -FINAL + (T INIT - T FINAL)
- EXP( -BETA*TIME(min)
- NTTH NT=101 STYL TINIT=550 TFINAL=190 BETA=0.15
48 Record 12 - NPTH Record 12 inputs the time history table for the internal coolant pressure boundary condition. There are NP data pairs of time, t, in minutes and internal coolant pressure, p, in kilo-pounds force per square inch (ksi) entered following the NPTH keyword record line. The number of data pairs is limited only by the memory capacity of the computer.
EXAMPLE
- ========================= *
- Record NPTH *
- ========================= *
- PRESSURE TRANSIENT: PRESSURE vs TIME HISTORY *
- NP = NUMBER OF (TIME,PRESSURE) DATA PAIRS *
- (CAN INPUT UP TO 1000 PAIRS OF t,P(t) data records
- NPTH NP=2
- ==============================
- TIME[MIN] P(t)[ksi]
- ==============================
0.0 1.0 120.0 1.0 2.2 FAVOR PFM Module - FAVPFM A total of 11 + NT + NWSUB + NPSUB data records (the value of NT is defined in Record 9, NWSUB is defined in Record 10 + NT, and NPSUB is defined in Record 11 + NT), listed in Table 2, are required in the FAVPFM input file, where each record may involve more than one line of data. A detailed description of each data record is given below.
Record 1 - CNT1 Record No. 1 inputs the number of simulations, NSIM, for the plant-specific analysis of this RPV, the number of trials/realizations.
The IPFLAW flag sets the distributions of surface-breaking and embedded flaws within the RPV wall that are assumed for this analysis.
IPFLAW = 1: surface-breaking flaws are internal (reside on the inside surface of the RPV) and embedded flaws are uniformly distributed within the inner 3/8ths of the RPV base metal; IPFLAW = 2: surface-breaking flaws are external (reside on the outside surface of the RPV) and embedded flaws are uniformly distributed in the outer 3/8ths of RPV base metal;
49 IPFLAW = 3: surface-breaking flaws are both internal and external with 50% external surface-breaking and 50% internal surface-breaking flaws. Embedded flaws are distributed uniformly throughout the entire RPV base metal thickness.
The IGATR flag (where IGATR is bounded from 100 to 1000, i.e., 100 IGATR1000.), is applied per flaw in the Initiation-Growth-Arrest (IGA) model, WPS_OPTION sets the warm-prestressing option (WPS_OPT=1l2l3) on or off (WPS_OPT=0).
WPS_OPTION = 0 do not include warm-prestressing in analysis WPS_OPTION ={ 1l2l3 }- enter into WPS state when dK/dt < 0 Three options are available for recovery from a WPS state WPS_OPTION = 1 exit WPS and be available for initiation when applied-KI exceeds maximum KI determined from all previous discrete transient time steps i.e., dK/dt > 0 and KI
> alpha*KImax where alpha = 1 ;
WPS_OPTION = 2 exit WPS and be available for initiation when dK/dt > 0 and KI > alpha*KImax where alpha = 0 ;
WPS_OPTION = 3 exit WPS and be available for initiation when applied KI exceeds maximum KI determined from all previous discrete transient time steps i.e., dK/dt > 0 and KI >
alpha*KImax where alpha is sampled from a log-logistic distribution as discussed in the Theory Manual [2] with location parameter = 0, scale parameter =
1.15643, and shape parameter = 20.12346.
The PC3_OPT flag sets the Category 3-flaws-in-plate-material option (PC3_OPT = 0 dont perform or = 1 do perform analysis). In a typical PFM analysis, a substantial fraction of the total flaws are Category 3 flaws in plate regions. Based on experience and some deterministic fracture analyses, these flaws rarely contribute to the CPI or CPF with the plate flaw size distributions typically used.
Therefore, setting PC3_OPT = 0 can result in significantly shorter execution times without affecting the solution, unless there are unusual circumstances such as using a new flaw-size distribution for plate flaws. In either case, the Category 3 plate flaws are included in the bookkeeping reports.
The CHILD_OPT flag sets the child reports option (CHILD_OPT = 0 dont include child subregion reports or = 1 include child subregion reports in the FAVPFM output file). The discretization and organization of major regions and subregions in the beltline includes a special treatment of weld-fusion lines. These fusion lines can be visualized as approximate boundaries between the weld
50 subregion and its neighboring plate or forging subregions. FAVOR checks for the possibility that the plate subregions adjacent to a weld subregion (termed parent subregions) could have a higher degree of radiation-induced embrittlement than the weld. The irradiated value of RTNDT for the weld parent subregion of interest is compared to the corresponding values of the adjacent (i.e., nearest-neighbor) plate subregions. Each parent weld subregion will have at most two adjacent child plate subregions.
The embrittlement-related properties of the most-limiting (either the weld or the adjacent plate subregion with the highest value of irradiated RTNDT) material are used when evaluating the fracture toughness of the weld subregion. A given parent weld subregion will have either itself or an adjacent plate subregion as its child subregion from which it will draw its chemistry.
51 Table 2. Record Keywords and Parameter Fields for FAVPFM Input File Record Keyword Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7 Field 8 1
CNT1 NSIM=[-]
IPFLAW=[1l2l3]
IGATR=[-]
WPS_OPT=[0l1l2l3]
PC3_OPT=[0l1]
CHILD_OPT=[0l1] RESTART_OPTION=[0l1]
2 CNT2 IRTNDT=[992l2000l2006]
TC=[°F]
EFPY=[yr]
IDT_OPT=[0l1l2]
IDT_INI=[0l1]
ILONG_OUT=[0l1]
3 CNT3 FLWSTR=[ksi]
USKIA=[ksiin]
KIa_Model=[1l2]
LAYER_OPT=[0l1]
FAILCR=[-]
4 GENR SIGFGL=[-]
SIGFLC=[-]
5 SIGW WSIGCU=[wt%]
WSIGNI=[wt%]
WSIGP=[wt%]
6 SIGP PSIGCU=[wt%]
PSIGNI=[wt%]
PSIGP=[wt%]
7 TRAC ITRAN=[-]
IRPV=[-]
KFLAW=[-]
LOG_OPT=[0l1]
8 LDQA IQA=[0l1]
IOPT=[1l2]
IFLOR=[1l2]
IWELD=0l1]
IKIND=[1l2][3]
XIN=[in]
XVAR=[inlmin] ASPECT=[-]
9 DTRF NT=[-]
10 ISQ ITRAN=[-]
ISEQ=[-]
TSTART=[min]
TEND=[min]
11 ISQ ITRAN=[-]
ISEQ=[-]
TSTART=[min]
TEND=[min]
9+NT ISQ ITRAN=[-]
ISEQ=[-]
TSTART=[min]
TEND=[min]
10+NT WELD NWSUB=[-]
NWMAJ=[-]
11+NT PLAT NPSUB=[-]
NPMAJ=[-]
Record Fields 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 Embrittlement and Flaw-Distribution Map Records 11+NT+NWSUB+NPSUB records: Each record has 20 fields with one line per record Input NWSUB records for all weld subregions followed by NPSUB records for all plate subregions Field Units 1
RPV Subregion Number (parent)
[-]
2 adjacent subregion number (1st child)
[-]
3 adjacent subregion number (2nd child)
[-]
4 RPV Major Region Number
[-]
5 best-estimate fast-neutron fluence at RPV inside surface
[10 19 n/cm 2]
6 heat-estimate copper content
[wt% Cu]
7 heat-estimate nickel content
[wt% Ni]
8 heat-estimate phosphorous content
[wt% P]
9 heat-estimate manganese content
[wt% Mn]
10 product-form flags for T 30 shift correlation Welds: set distribution for sampling for standard deviation for Ni content in welds 1 = normal distribution
[-]
2 = Weibull distribution
[-]
Plates: set flag for Combustion Engineering (CE) vessel 1 = CE vessel (if IRTNDT=2000 then B will be set to 206)
[-]
2 = not a CE vessel (if IRTNDT=2000 then B will be to 156)
[-]
11 Cu saturation flag =
0 for plates and forgings
[-]
1 for Linde 80 and Linde 0091 weld fluxes
[-]
2 for all weld fluxes other than L80, L0091, and L1092
[-]
3 for L1092 weld flux
[-]
12 best-estimate (mean) for unirradiated RT NDT0
[°F]
13 best-estimate for standard deviation for unirradiated RT NDT 0
[°F]
14 product-form flag for chemistry-factor (CF) override 11 = weld with no CF override
[-]
[-]
21 = plate with no CF override
[-]
22 = plate with CF override
[-]
31 = forging
[-]
15 angle of subregion element
[degrees]
16 axial height of subregion element
[in]
17 weld fusion area
[in 2]
18 flaw orientation: 1 = axial; 2 = circumferential
[-]
19 chemistry-factor override
[-]
20 best-estimate for unirradiated upper-shelf CVN energy
[ft-lbf]
Description
52 The flaw orientation, location, size, fast-neutron fluence, and category are not linked. A parent plate subregion always has no child subregion dependency. For each transient, the basic major region and flaw-distribution reports are given in terms of the parent weld subregions. By setting CHILD_OPT = 1, in addition to the parent reports, major region and flaw-distribution reports will also be output in terms of the child subregions (i.e., the subregions that control the allocation of embrittlement properties to weld subregions). If this option is set, additional data will be passed onto FAVPost where child subregion reports will also be generated.
With the older ductile-tearing model (see Record 2 - CNT2 for details on the ductile-tearing models) turned on (IDT_OPTION=2), a second independent set of parent/child relationships are established to determine the source for ductile-tearing property data including chemistry content and USEi. For ductile tearing the controlling property is the relative magnitude of the irradiated upper-shelf CVN energy, USEi. FAVOR checks for the possibility that the plate subregions adjacent to a weld subregion (termed parent subregions) could have a lower level of ductility than the parent weld subregion. The irradiated value of the upper-shelf CVN energy (USEi) for the weld parent subregion of interest is compared to the corresponding values of the adjacent (i.e., nearest-neighbor) plate subregions. Each weld subregion will have at most two adjacent plate subregions. The embrittlement-related properties of the most-limiting (either the weld or the adjacent plate subregion with the lowest value of USEi ) material are used when evaluating the ductile-fracture properties of the weld subregion. A given parent weld subregion will have either itself or an adjacent plate subregion as its child subregion from which it will inherit its chemistry and USEi. This model has been superseded by a newer ductile-tearing model (IDT_OPTION=1) which is not based on the USEi, and does not require a second parent/child dependency structure.
A restart option is included in FAVPFM. If RESTART_OPTION 0, the current execution is not based on a restart of a previous run. At user-selected checkpoints during FAVPFM execution, a binary restart file will be created (RESTART.BIN) which during a subsequent execution can be used to restart FAVPFM from the point in the solution at which the restart file was created. By default, this restart file is created at intervals of 200 RPV trials. The user can change this checkpoint interval by setting RESTART_OPTION to a negative integer. For example, if RESTART_OPTION = -500, then the effect will be the same as RESTART_OPTION = 0, except that the restart checkpoint interval will be 500 RPV trials. If RESTART_OPTION 1, then this execution will be treated as a restart case, and the user will be prompted for the name of a binary restart file created during a previous execution. For this restart case, new restart files will be created at user-selected checkpoint intervals where, for RESTART_OPTION = 1, the default checkpoint interval is 200. For
53 RESTART_OPTION > 1, then the checkpoint interval is equal to the value of the flag setting, (e.g.,
RESTART_OPTION = 500 indicates a checkpoint interval of 500 RPV trials).
EXAMPLE
- ==================== *
- Control Record CNT1 *
- ==================== *
- NSIM = NUMBER OF RPV SIMULATIONS *
- IPFLAW = FLAW POPULATION MODEL *
- IPFLAW = 1 Identical to previous version of FAVOR - primarily for cooldown transients. *
- All Surface flaws (in surface flaw characterization file) will be inner surface *
- breaking flaws. Only those embedded flaws (in weld and plate flaw characterization *
- files) in the inner 3/8 of the RPV wall thickness would be included in the model. *
- IPFLAW = 2 Similar to previous version of FAVOR-HT - primarily for heat-up transients. *
- All surface breaking flaws (in surface flaw characterization file) would be *
- external surface breaking flaws. Only those embedded flaws in the outer 3/8 of the *
- RPV wall thickness would be included in the model. *
- IPFLAW = 3 The number of postulated surface breaking flaws (in surface flaw characterization *
- file) would be double that of options 1 and 2; evenly divided between internal *
- and external surface breaking flaws. All of the embedded flaws uniformly *
- distributed through the RPV wall thickness would be included in the model. *
- See Theory Manual for further discussion. *
- IGATR = NUMBER OF INITIATION-GROWTH-ARREST (IGA) TRIALS PER FLAW *
- WPS_OPTION = 0 DO NOT INCLUDE WARM-PRESTRESSING IN ANALYSIS *
- WPS_OPTION = 1 INCLUDE TRADITIONAL FAVOR BASELINE WARM-PRESTRESSING Model IN ANALYSIS *
- WPS_OPTION = 2 INCLUDE Conservative Principal WARM-PRESTRESSING MODEL IN ANALYSIS *
- WPS_OPTION = 3 INCLUDE Best-Estimate WARM-PRESTRESSING MODEL IN ANALYSIS *
- See Theory Manual for details regarding WARM_PRESTRESS Models *
- Note: Previous Versions of FAVOR prior to the 15.1 included only options 0 and 1. *
- CHILD_OPTION = 0 DO NOT INCLUDE CHILD SUBREGION REPORTS [-] *
- CHILD_OPTION = 1 INCLUDE CHILD SUBREGION REPORTS [-] *
- RESTART_OPTION = 0 THIS IS NOT A RESTART CASE [-] *
- RESTART_OPTION = 1 THIS IS A RESTART CASE [-] *
- ============================= *
- Notes for Control Record CNT1 *
- ============================= *
- IN A TYPICAL PFM ANALYSIS, A SUBSTANTIAL FRACTION OF THE TOTAL FLAWS ARE CATEGORY 3 FLAWS IN *
- PLATE REGIONS. BASED ON EXPERIENCE AND SOME DETERMINISTIC FRACTURE ANALYSES, THESE FLAWS VERY *
- THEREFORE, INVOKING IP3OPT = 0 CAN RESULT IN A SIGNIFICANT REDUCTION IN EXECUTION TIME WITHOUT *
- AFFECTING THE SOLUTION, UNLESS THERE ARE UNUSUAL CIRCUMSTANCES SUCH AS A NEW FLAW-SIZE *
- DISTRIBUTION FOR PLATE FLAWS. IN EITHER CASE, CATEGORY 3 PLATE FLAWS ARE INCLUDED IN ALL REPORTS. *
- IF IPFLAW = 3; THEN PC3_OPTION AUTOMATICALLY OVER-RIDES AND SETS PC3_OPTION = 1 *
- Notes on Restart Option: *
- The restart option flag can also be used to control the frequency with which restart files are *
- created. If RESTART_OPTION is given a value other than 0 or 1, then the absolute value of this flag *
- sets the checkpoint interval at which the restart file will be created during the run. For example, *
- 1.RESTART_OPTION = -200==> This is not a restart case; restart files will be created every 200 trials *
- 2.RESTART_OPTION = 0==> Same as example No. 1. *
- 3.RESTART_OPTION = 200==> This is a restart case; restart files will be created every 200 trials.*
- 4.RESTART_OPTION = 1==> Same as example No. 3. *
- 5.RESTART_OPTION = -50==> This is not a restart case; restart files will be created every 50 trials.
- CNT1 NSIM=100 IPFLAW=1 IGATR=100 WPS_OPTION=1 PC3_OPTION=0 CHILD_OPTION=1 RESTART_OPTION=0 Record 2 - CNT2 Record No. 2 inputs a flag, IRTNDT, that designates the correlation to be used for irradiation shift calculations, where IRTNDT = 992 use Regulatory Guide 1.99, Rev. 2, for irradiation shift in RTNDT IRTNDT = 2000 use Eason 2000 [24, 25] correlation for irradiation shift in RTNDT
54 IRTNDT = 2006 use the Eason 2006 [26] correlation for irradiation shift in RTNDT IRTNDT = 20071 use the Kirk 2007 correlation for irradiation shift in RTNDT IRTNDT = 20072 use the RADAMO 2007 correlation for irradiation shift in RTNDT IRTNDT = 20073 use the combined EasonKirk/RADAMO 2007 correlation for irradiation shift the normal operating coolant temperature, TC, in F, the plant operating time, EFPY, to be assumed for this case in effective full-power years, and a flag IDT_OPTION to turn on (IDT_OPTION1) or off (IDT_OPTION=0) the ductile-tearing model in the IGA submodel. If IDT_OPTION=2, the ductile-tearing model introduced in v03.1 can be activated; however, this model is no longer supported and is maintained in FAVOR for backward compatibility with v03.1 executions only. The newer ductile-tearing model (IDT_OPTION=1) is recommended when investigating the effects of ductile tearing. The flag IDT_INI provides additional reporting concerning flaw initiation due to ductile tearing. Currently, there is no model in FAVOR to determine the probability of flaw initiation by ductile tearing. The ductile-tearing model simulates reinitiation by tearing only after a flaw has arrested. The additional reporting when IDT_INI=1 provides a log of the number of potential ductile-tearing flaw initiations (when applied Ic J
J
) that occurred during the analysis. It should be noted that setting IDT_INI=1 has the potential of significantly increasing the computational time for a given run. When IDT_INI=0, the checks for ductile-tearing initiation are not carried out. When the ductile-tearing option is activated, however, checks for ductile-tearing reinitiation of an arrested flaw will always be performed. The flag ILONG_OUT provides additional reporting concerning the contribution to the CPI and CPF from the major regions in the belt line for each transient. When ILONG_OUT=1, a series of files named History_itran_iseq.out (where itran is the FAVOR transient number and iseq is the associated thermal-hydraulic initiating-event sequence number from the RELAP5 cases) will be created during the execution that will contain results data for all of the RPV trials. The user should note that for long FAVPFM executions, these files could become quite large and their creation may have an impact on run times. When ILONG_OUT=0, these files are not created.
EXAMPLE
- ==================== *
- Control Record CNT2 *
- ==================== *
- IRTNDT = 2000==> USE E2000 CORRELATION FOR ESTIMATING RADIATION SHIFT IN RTNDT *
- IRTNDT = 2006==> USE E2006 CORRELATION FOR ESTIMATING RADIATION SHIFT IN RTNDT *
- IRTNDT = 20071==> USE EricksonKirk 2007 CORRELATION FOR ESTIMATING RADIATION SHIFT IN RTNDT *
- IRTNDT = 20072==> USE RADAMO CORRELATION FOR ESTIMATING RADIATION SHIFT IN RTNDT *
- IRTNDT = 20073==> USE COMBINED EricksonKirk 2007 + RADAMO CORRELATIONS FOR RADIATION SHIFT *
- EFPY = EFFECTIVE FULL-POWER YEARS OF OPERATION [YEARS] *
- IDT_OPTION = 0 DO NOT INCLUDE DUCTILE TEARING AS A POTENTIAL FRACTURE MODE [-] *
- IDT_OPTION = 1 INCLUDE DUCTILE TEARING AS A POTENTIAL FRACTURE MODE [-]
- 55
- IDT_INI = 0 DO NOT CREATE A LOG OF POTENTIAL DUCTILE TEARING INITIATIONS [-] *
- IDT_INI = 1 CREATE A LOG OF POTENTIAL DUCTILE TEARING INITIATIONS [-] *
- ILONG_OUT = 0 DO NOT CREATE Major-Region ITRAN Files [-] *
- ILONG_OUT = 1 CREATE Major-Region ITRAN Files [-]
- CNT2 IRTNDT=2006 TC=556 EFPY=60 IDT_OPTION=1 IDT_INI=0 ILONG_OUT=1*====================
Record 3 - CNT3 Record No. 3 inputs values for the flow stress, FLWSTR, in ksi to be used in the failure model of plastic collapse (ligament instability), the upper bound for KIc and KIa, USKIA, in ksi in., a flag KIa_Model to designate which arrest model (1 or 2) to use in checking for stable arrest, the weld layer resampling option, LAYER_OPT, (on or off), and the fraction of the total wall thickness, FAILCR, used in the vessel failure criterion. If a flaw, propagating from the inner surface of the vessel, grows to this depth into the wall (relative to the inner surface), then the event will be designated as a vessel failure, where 0.25 FAILCR 0.95
EXAMPLE
- ==================== *
- Control Record CNT3 *
- ==================== *
- FLWSTR = UNIRRADIATED FLOW STRESS USED IN PREDICTING FAILURE BY REMAINING LIGAMENT INSTABILITY [ksi] *
- USKIA = MAXIMUM VALUE ALLOWED FOR KIc or KIa [ksi-in^1/2] *
- KIa_Model = 1 Use high-constraint KIa model based on CCA specimens [-] *
- KIa_Model = 2 Use KIa model based on CCA + large specimen data [-] *
- LAYER_OPTION = 0 DONOT RESAMPLE PF WHEN ADVANCING INTO NEW WELD LAYER [-] *
- LAYER_OPTION = 1 RESAMPLE PF WHEN ADVANCING INTO NEW WELD LAYER [-] *
- FAILCR = FRACTION OF WALL THICKNESS FOR VESSEL FAILURE BY THROUGH-WALL CRACK PROPAGATION [-] *
- ============================= *
- Notes for Control Record CNT3 *
- ============================= *
- If ductile tearing model is included, then the values for USKIA and KIa_Model are ignored. *
- They are automatically set internally to KIa_Model=2 and there is no upper limit on USKIa. *
- If ductile tearing is not included in the analysis (IDT_OPTION = 0 on CNT1), both the KIa_Model *
- and USKIA are user-specified on CNT3.
- CNT3 FLWSTR=80. USKIA=200. KIa_Model=1 LAYER_OPTION=1 FAILCR=0.9
56 Record 4 - GENR Record No. 4 inputs the value of two multipliers, SIGFGL and SIGFLC, used to obtain the standard deviations of a global and local normal distribution for fluence sampling, where the fluence at the inner surface, (0) f 1, is sampled from two normal distributions such that
(
)
(0)
(,
)
global subregion subregion global local local SIGFGL fluence f
N fluence SIGFLC f
f N f
where subregion fluence is the best-estimate for the subregion neutron fluence as input in the embrittlement map (to be described below).
EXAMPLE
- ==================== *
- Record GENR *
- ==================== *
- SIGFGL = A MULTIPLIER ON THE BEST ESTIMATE OF FLUENCE FOR A GIVEN SUBREGION [-] *
- PRODUCES THE STANDARD DEVIATION FOR THE NORMAL DISTRIBUTION USED TO SAMPLE THE MEAN *
- OF THE LOCAL FLUENCE DISTRIBUTION. *
- SIGFLC = A MULTIPLIER ON THE SAMPLED MEAN OF THE LOCAL FLUENCE FOR A GIVEN SUBREGION [-] *
- PRODUCES THE STANDARD DEVIATION FOR THE NORMAL DISTRIBUTION USED TO SAMPLE THE LOCAL FLUENCE*
- ====================== *
- Notes for Record GENR *
- ====================== *
- Let "flue" be the best estimate for the subregion neutron fluence at inside surface of the RPV wall. *
- flue_STDEV_global = SIGFGL*flue *
- flue_MEAN_local << Normal(flue,flue_STDEV_global) *
- flue_STDEV_local = SIGFLC*flue_MEAN_local *
- flue_local << Normal(flue_MEAN_local,flue_STDEV_local)
- GENR SIGFGL=0.01 SIGFLC=0.01 Records 5 and 6 - SIGW AND SIGP Records No. 5 and 6 input the values of the standard deviations of the initial normal sampling distributions for the weld and plate chemistries, respectively. On Record 5, the three data fields include the standard deviations for the weight % of copper, Cu, WSIGCU, nickel, Ni, WSIGNI, and phosphorous, P, WSIGP in welds. On Record 6, the three data fields include the standard deviations for the weight % of Cu, PSIGCU, Ni, PSIGNI, and P, PSIGP in plates and forgings. The heat estimates for Cu, Ni, and P given in the embrittlement map described below are used as the means of the normal sampling distributions for the weld and plate chemistries.
1 A curved overbar indicates a sampled random variate, e.g.,
(, )
f N
means the random variate f has been sampled from a normal distribution with mean and standard deviation.
57 The weld chemistries are sampled using the following protocols:
For Ni-addition welds Heats 34B009 &W5214
(
)
min(0.0718
,0.0185) 0.162
(
)
For other heats
(
)
(0.029,0.0165)
(
Heat Heat Cu Heat Cu Cu Heat Cu Ni Cu Cu WSIGCU Ni N Ni WSIGNI Cu WSIGNI N Cu Cu N Cu N
Ni N
(
)
)
Heat Heat Ni P
N P WSIGP Ni
The plate chemistries are sampled using the following protocols:
(
)
(
)
(
)
Heat Heat Heat Cu N Cu PSIGCU Ni N Ni PSIGNI P
N P PSIGP
EXAMPLE
- ==================== *
- Record SIGW *
- ==================== *
- STANDARD DEVIATIONS (STDEV) OF NORMAL DISTRIBUTIONS FOR WELD CHEMISTRY SAMPLING: *
- WSIGP = STANDARD DEVIATION FOR PHOSPHOROUS CHEMISTRY SAMPLING IN WELDS [wt%] *
- ====================== *
- Notes for Record SIGW *
- ====================== *
- (1) FOR HEATS 34B009 AND W5214 (Ni - addition welds) *
- WSIGNI = 0.162 wt% using a normal distribution. *
- (2) For other heats, the standard deviation (WSIGNI) shall be sampled from a normal distribution *
- with mean equal to 0.029 wt% and standard deviation = 0.0165 wt%
- SIGW WSIGCU=0.167 WSIGNI=0.162 WSIGP=0.0013
- ==================== *
- Record SIGP *
- ==================== *
- STANDARD DEVIATIONS (STDEV) OF NORMAL DISTRIBUTIONS FOR PLATE CHEMISTRY SAMPLING: *
- PSIGCU = STANDARD DEVIATION FOR COPPER CHEMISTRY SAMPLING IN PLATES [wt%] *
- PSIGNI = STANDARD DEVIATION FOR NICKEL CHEMISTRY SAMPLING IN PLATES [wt%] *
- PSIGP = STANDARD DEVIATION FOR PHOSPHOROUS CHEMISTRY SAMPLING IN PLATES [wt%] *
- ====================== *
- Notes for Record SIGP *
- ====================== *
- RECOMMENDED VALUES ARE: 0.0073, 0.0244, 0.0013 for Cu, Ni, and P, respectively.
- SIGP PSIGCU=0.0073 PSIGNI=0.0244 PSIGP=0.0013
- =============================== *
- Notes for RecordS SIGW and SIGP *
- =============================== *
- THE ABOVE DISTRIBUTIONS ARE FOR THE 1ST FLAW POSITIONED IN A PARTICULAR SUBREGION. *
- IF THE CURRENT FLAW IS THE 2ND OR MORE FLAW FOR THIS SUBREGION, THEN FAVPFM WILL USE *
- THE LOCAL VARIABILITY SAMPLING PROTOCOLS PRESENTED IN THE THEORY MANUAL.
- 58 Record 7 - TRAC Record No. 7 provides a mechanism for the user to put a trace on a particular flaw, KFLAW, in a specific simulation, IRPV, and for a specific transient, ITRAN. This facility provides a Quality Assurance tool to verify the computational models(s) used to calculate values of CPI and CPF. Data describing the initiation, crack growth, and arrest check calculations are written to the files TRACE.OUT and ARREST.OUT. The variable ITRACK=1 creates flaw-tracking log tables to help identify values for (ITRAN, IRPV, KFLAW) to specify in later executions. These tables can be found in the file TRACE.OUT. An additional file is created called FLAW_TRACK.LOG which provides data for the first 10,000 flaws sampled during the execution.
EXAMPLE
- ==================== *
- Record TRAC *
- ==================== *
- ITRAN = TRANSIENT NUMBER [-] *
- KFLAW = FLAW NUMBER [-] *
- FLAW_LOG_OPTION = 0 DO NOT CREATE FLAW LOG TABLES [-] *
- FLAW_LOG_OPTION = 1 DO CREATE FLAW LOG TABLES [-] *
- =============================== *
- Notes for Record TRAC *
- =============================== *
- HISTORY WILL BE GIVEN IN THE FILES: "TRACE.OUT" AND "ARREST.OUT" *
- SEE THE USER'S GUIDE FOR DETAILS ON THE CONTENTS OF THESE FILES
- TRAC ITRAN=3 IRPV=5 KFLAW=2652 FLAW_LOG_OPTION=1 Record 8 - LDQA Record No. 8 provides a mechanism for the user to carry out, as a deterministic or diagnostic exercise, deterministic calculations for the transients received from the FAVLoad module. This utility allows the user to tailor output reports containing (1) time histories of load-related variables at a specific location in the RPV wall or (2) through-wall profiles of load-related variables at a specific transient time. There are eight parameters associated with this record appearing on a single data line.
(1)
IQA = 1 activates the deterministic analysis module; no PFM analysis will be performed IQA = 0 ignore the rest of the data on this data line and proceed with a PFM analysis (2)
IOPT = 1 generate time history results at a specific location in the RPV wall IOPT = 2 generate through-wall profiles of stress and applied KI at a specific time (3)
IFLOR = 1 flaw orientation is axial IFLOR = 2 flaw orientation is circumferential (4)
IWELD = 0 do not include weld residual stresses IWELD = 1 include weld residual stresses (5)
IKIND = 1 inner surface-breaking flaw IKIND = 2 embedded flaw IKIND = 3 outer surface-breaking flaw
59 (6)
XIN - only used if IKIND = 2 (otherwise ignored) if IOPT = 1; XIN = location of inner crack tip from inner surface (in.)
if IOPT = 2; XIN = 2d = flaw depth (see Fig. 6)
(7)
XVAR - meaning depends on the value of IOPT if IOPT = 1; XVAR = flaw depth (in.) (a for IKIND = 1; 2d for IKIND = 2 in Fig. 6) if IOPT = 2; XVAR = elapsed time in minutes (8)
ASPECT aspect ratio = L / a for IKIND = 1; aspect ratio = L / 2d for IKIND = 2 if IKIND = 1 or 3; ASPECT = 2, 6, 10, or 999 if IKIND = 2; ASPECT > 0.0 EXAMPLE
- ==================== *
- Record LDQA *
- ==================== *
- THE LDQA RECORD PROVIDES THE OPPORTUNITY TO CHECK LOAD-RELATED SOLUTIONS *
- SUCH AS TEMPERATURE, STRESSES, AND KI. *
- IQA = 0==> THIS EXECUTION IS NOT FOR LOAD QA [-] *
- IQA = 1==> THIS EXECUTION IS FOR LOAD QA [-] *
- IOPT = 1==> GENERATE TIME HISTORY AT SPECIFIC THROUGH WALL LOCATION [-] *
- IOPT = 2==> GENERATE THROUGH WALL DISTRIBUTION AT SPECIFIC TIME [-] *
- IFLOR = 1==> FLAW ORIENTATION IS AXIAL [-] *
- IFLOR = 2==> FLAW ORIENTATION IS CIRCUMFERENTIAL [-] *
- IWELD = 0==> DOES NOT INCLUDE THRU-WALL WELD RESIDUAL STRESS [-] *
- IWELD = 1==> DOES INCLUDE THRU-WALL WELD RESIDUAL STRESS [-] *
- IKIND = 1==> INNER-SURFACE BREAKING FLAW [-] *
- IKIND = 2==> EMBEDDED FLAW [-] *
- IKIND = 3==> OUTER-SURFACE BREAKING FLAW [-] *
- XIN IS ONLY USED IF IKIND=2 (EMBEDDED FLAWS) *
- XIN = IF IOPT=1; LOCATION OF INNER CRACK TIP FROM INNER SURF. [IN] *
- XIN = IF IOPT=2; FLAW DEPTH [IN] *
- XVAR: IF IOPT=1; XVAR=FLAW DEPTH [IN] *
- IF IOPT=2; XVAR=TIME [MIN] *
- ASPECT = ASPECT RATIO; FOR SURFACE BREAKING FLAWS: 2,6,10,999 (infin) [-] *
- FOR EMBEDDED FLAWS: ANY VALUE > 0 *
- =============================== *
- Notes for Record LDQA *
- =============================== *
- IQA = 0 NO VALIDATION REPORTS WILL BE GENERATED, PFM ANALYSIS WILL BE PERFORMED *
- IQA = 1 LOAD PARAMETERS WILL BE GENERATED FOR VERIFICATION PURPOSES, PFM ANALYSIS WILL NOT BE PERFORMED*
LDQA IQA=0 IOPT=2 IFLOR=2 IWELD=0 IKIND=1 XIN=0.53 XVAR=70 ASPECT=99 Record 9 - DTRF In some cases, the PFM solution(s) can be sensitive to the time-step size (specified as DT on Record 7 in FAVLoad input as discussed in Sect. 2.1) used in the analysis. Some preliminary analysis is useful in determining a suitable DT that provides a converged PFM solution, i.e., converged in the sense that a decrease in DT does not result in a significant change in the solution. Decreasing DT resolves the load and fracture toughness variables better; however, smaller values of DT increase the number of discrete time steps to cover the transient, thus increasing the amount of computational effort required to perform the PFM analysis. Ideally, one would like to use a relatively small time step
60 in the PFM analysis for better accuracy, yet to perform the PFM analysis for only the time period during which all of the crack initiations and failures are predicted to occur.
Record 9 provides a mechanism to specify the starting and ending times for specific transients supplied in the FAVLoad output file. The variable NT sets the number of ISQ records that follow the DTRF record. The following NT records contain values for ITRAN (= the transient number in the transient stack supplied in the FAVLoad output file), ISEQ (= the corresponding identifying thermal-hydraulic sequence number), TSTART (= starting time in minutes), and TEND (= ending time in minutes). Only those transients in the FAVLoad transient stack for which the user wishes to set special values of TSTART and TEND need be identified by the DTRF records. All other transients in the stack, not explicitly specified in the DTRF records, will use the global transient start (always =
0.0) and ending times set by the execution of the FAVLoad module.
During preliminary analyses to determine a suitable DT that provides a converged solution, one may also determine for each transient the time period during which postulated cracks are predicted to initiate and propagate through-the-wall since this information is reported for each transient in the Transient Time Distribution Report (See example FAVPFM output in Sect. 2.6). Limiting the time period during which the PFM analysis is performed for each transient will reduce the computational effort.
EXAMPLE No. 1
- ==================== *
- Record DTRF *
- ==================== *
- NT = number of ISQ records that follow [-] *
- NT = 0 no ISQ records follow *
- FOLLOWING THE DTRF RECORD, THERE SHOULD BE "NT" SUBRECORDS *
- ISQ ITRAN= ISEQ= TSTART= TEND= *
- ITRAN = sequential number in FAVLoad transient stack [-] *
- ISEQ = Thermal Hydraulic trasient sequence number [-] *
- TSTART = starting time for FAVPFM analysis [MIN] *
- TEND = ending time for FAVPFM analysis [MIN]
- DTRF NT=4 ISQ ITRAN=1 ISEQ=7 TSTART=2 TEND=35 ISQ ITRAN=2 ISEQ=9 TSTART=1 TEND=29 ISQ ITRAN=3 ISEQ=56 TSTART=9 TEND=56 ISQ ITRAN=4 ISEQ=97 TSTART=11 TEND=85
61 To use the global starting and ending times for all transients, set in FAVLoad Input Record 7, input the following:
EXAMPLE No. 2
- ==================== *
- Record DTRF *
- ==================== *
- NT = number of ISQ records that follow [-] *
- NT = 0 no ISQ records follow *
- FOLLOWING THE DTRF RECORD, THERE SHOULD BE "NT" SUBRECORDS *
- ISQ ITRAN= ISEQ= TSTART= TEND= *
- ITRAN = sequential number in FAVLoad transient stack [-] *
- ISEQ = Thermal Hydraulic trasient sequence number [-] *
- TSTART = starting time for FAVPFM analysis [MIN] *
- TEND = ending time for FAVPFM analysis [MIN]
- DTRF NT=0 Records 10+NT and 11+NT Records 10+NT and 11+NT give the number of major regions and subregions for welds and plates, respectively. The sum of the number of weld subregions, NWSUB, and the number of plate subregions, NPSUB, gives the total number of embrittlement map records to follow this keyword line. NWMAJ is the number of major weld regions, and NPMAJ is the number of major plate regions.
EXAMPLE
- ==================== *
- Record WELD *
- ==================== *
- NWSUB = NUMBER OF WELD SUBREGIONS [-] *
- NWMAJ = NUMBER OF WELD MAJOR REGIONS [-]
- WELD NWSUB=838 NWMAJ=5
- ==================== *
- Record PLAT *
- ==================== *
- NPSUB = NUMBER OF PLATE SUBREGIONS [-] *
- NPMAJ = NUMBER OF PLATE MAJOR REGIONS [-]
- PLAT NPSUB=14442 NPMAJ=4 Records 12+NT through 11+NT+NWSUB+NPSUB Following Record 11+NT, there will be NWSUB + NPSUB data lines (one record per subregion and one data line per record) that contain the embrittlement map for all of the weld and plate subregions. Note that the data records for the weld subregions must precede the data records for the plate subregions. There are 20 fields in each record.
62 (1) subregion number - subregion numbers should start with 1 and then increment by 1 for the complete embrittlement map.
Flaws in welds have been observed to reside along the fusion line between the weld and adjacent plate; therefore, it is possible that the adjacent plate(s) could have a higher degree of embrittlement and/or less ductility than the weld. The embrittlement/ductility-related properties of the most limiting (of the weld or the adjacent plate) material shall be used when evaluating flaw advancement by cleavage propagation or ductile tearing. If this subregion is a weld region, FAVOR will determine if one of the adjacent plate(s), located in adjacent-plate subregions, is more limiting, i.e., has a higher RTNDT for cleavage propagation and a lower value of USEi for flaw advancement by ductile tearing (IDT_OPTION=2 only). If so, FAVOR will use the embrittlement/ductility properties of the more limiting subregion, where separate sets of parent/child relationships are determined for cleavage propagation and ductile tearing. The next two fields are valid only if the subregion designated in field 1 is a weld subregion. From a roll-out map of the RPV beltline, select the plate subregions that are adjacent to the weld subregion in field 1. If field 1 refers to a plate subregion, just repeat the subregion number from field 1 in fields 2 and 3.
(2) left-adjacent plate subregion number (3) right-adjacent plate subregion (4) major region number (5) best estimate for fast-neutron fluence at inside surface of RPV wall ( 1019 neutrons/cm2)
(6) heat estimate for copper content (wt% Cu),
Heat Cu (7) heat estimate for nickel content (wt% Ni),
Heat Ni (8) heat estimate for phosphorous content (wt% P),
Heat P
(9) heat estimate for manganese content (wt% Mn),
Heat Mn (10) if field 1 is a weld subregion select the method for determining the standard deviation for the normal distribution used to simulate the Ni content
= 1 use the constant value given in the WSIGNI field on Record 5. (These are Ni-addition welds from heats 34B009 and W5214 in the RVID2 database.)
= 2 sample from a normal distribution with (0.029,0.0165)
Ni N
(all other heats)
63 (10) if field 1 is a plate subregion with IRTNDT=2000 or 2006 on Record 2 (ignored if IRTNDT=992)
= 1 Combustion Engineering (CE) plate
= 2 all other plates and forgings (11) copper saturation flag when IRTNDT = 2000 or 2006 on Record 2 (ignored if IRTNDT=992)
= 0 for plates and forgings
= 1 for Linde 80 and Linde 0091 weld fluxes
= 2 for all weld fluxes other than Linde 80, Linde 0091, or Linde 1092
= 3 for Linde 1092 weld flux (12) RVID2 heat estimate for unirradiated value of RTNDT (RTNDT0) (F) (see Appendix B)
(13) standard deviation for RTNDT0 (F). If the RTNDT(u) Method in Appendix B is either MTEB 5-2 or ASME NB-2331, enter a 0.0. If the RTNDT(u) Method in Appendix B is Generic, enter a best-estimate for the standard deviation.
(14) Irradiation-shift-correlation flag when IRTNDT=2000 or 2006 on Record 2
= 11 weld major region
= 21 plate major region
= 31 forging major region (14) Irradiation-shift-correlation flag when IRTNDT = 992 on Record 2
= 11 weld major region; no chemistry-factor override
= 12 weld major region; with chemistry-factor override
= 21 plate major region; no chemistry-factor override
= 22 plate major region; with chemistry-factor override
= 31 forging major region (15) Angle of subregion element, d (degrees) (see Fig. 17 on the following page )
(16) Axial height of subregion element, dz (inches) (see Fig. 17 on the following page)
(17) Weld fusion area (=0.0 for plate subregions) (in2) (see Figs. 17a and b)
(18) Weld orientation; =1 axial; =2 circumferential (ignored if Plate subregion)
64 (19) Chemistry-factor override; (if IRTNDT=992 on Record 2 and irradiation shift correlation flag (field 13) = 12 or 22), otherwise set to 0.
(20) Unirradiated upper-shelf CVN energy (USE0) in [ft-lbf] from RVID2, (used only if IDT_OPTION=2
65 (a)
(b)
Fig. 17. Weld fusion area definitions for (a) axial-weld subregion elements and (b) circumferential-weld subregion elements.
66 Fig. 17. (continued) (c) Plate subregion element.
67 EXAMPLE
- EMBRITTLEMENT / FLAW DISTRIBUTION MAP RECORDS *
- ========================================================================================================*
- Field DESCRIPTION [UNITS] *
- ========================================================================================================*
- (1) RPV subregion number - parent [-] *
- (2) adjacent RPV subregion - 1st child [-] *
- (3) adjacent RPV subregion - 2nd child [-] *
- (4) RPV major region number [-] *
- (5) best estimate neutron fluence at RPV inside surface [10^19 neutrons/cm^2] *
- (6) heat estimate copper content [wt% Cu] *
- (7) heat estimate nickel content [wt% Ni] *
- (8) heat estimate phosphorus content [wt% P] *
- (8) best estimate phosphorus (P) content [wt% P] *
- (9) best estimate manganese (Mn) content [wt% Mn] *
- (10) product form flags for DT30 shift correlation *
- Welds : set distribution for sampling standard *
- deviation for Ni content in welds *
- = 1 use normal distribution [-] *
- = 2 use Weibull distribution [-] *
- Plates: *
- CE = 1 (if IRTNDT=2000 then set B = 206) [-] *
- Not CE = 2 (if IRTNDT=2000 then set B = 156) [-] *
- where CE is a Combustion Engineering vessel *
- (11) copper saturation flag = 0 for plates and forgings [-] *
- = 1 for Linde 80 and Linde 0091 weld fluxes *
- = 2 for all weld fluxes other than L80, L0091, and L1092 *
- = 3 for Linde 1092 weld flux *
- N.B.: *
- for IRTNDT = 2000 *
- = 0.25 for Linde 80 and = 0.305 for all others *
- for IRTNDT = 2006 *
- = 0.37 for Ni < 0.5 wt% *
- = 0.2435 for 0.5 <= Ni <= 0.75 wt% *
- (12) unirradiated best estimate (mean) for RTNDT0 [F] *
- (13) unirradiated standard deviation for RTNDT0 [F] *
- (14) PF flag Product Form CF Override *
- = 11 weld no [-] *
- = 12 weld yes [-] *
- = 21 plate no [-] *
- = 22 plate yes [-] *
- = 31 forging NA [-] *
- (15) angle of subregion element [degrees] *
- (16) axial height of subregion element: [inches] *
- (17) weld fusion area: [inches^2] *
- (18) weld orientation: 1===> axial; 2===> circumferential [-] *
- (19) chemistry factor override [-] *
- (20) unirradiated upper shelf CVN engergy [ft-lbf] *
- ========================================================================================================*
- Notes: *
- 2. Fields 5-20 : contain RPV beltline embrittlement-related data *
- 3. Field 13 : PF means Product Form *
- 4. Field 13 : CF means chemistry factor override *
- 5. Field 18 : only applies to weld subregions. For plates set to 0. *
- 6. Field 20 : applicable only if IRTNDT=2000 on CNT2 and Field 13 = 12 or 22 *
- ========================================================================================================*
- ===========================================================================================*
68
- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 001 3593 3661 1.0675.337.609.012 1.44 2 3 -56. 17. 11 1. 1.2 9.45 1 0 98 002 3594 3662 1.1173.337.609.012 1.44 2 3 -56. 17. 11 1. 1.1996 9.4469 1 0 98 003 3595 3663 1.1682.337.609.012 1.44 2 3 -56. 17. 11 1. 2.3996 18.8969 1 0 98 004 3596 3664 1.2317.337.609.012 1.44 2 3 -56. 17. 11 1. 2.2047 17.3622 1 0 98 005 3597 3665 1.3100.337.609.012 1.44 2 3 -56. 17. 11 1. 2.3996 18.8969 1 0 98 Note that fields 6 through 14 are major-region variables and should be the same for all subregions in a given major region. As FAVPFM reads in the embrittlement/flaw distribution map records, it checks to make sure that the data in fields in 6 throught 14 are the same within each major region. If any differences are found, the code flags the error and stops the execution of FAVPFM.
2.3 FAVOR Post-Processing Module - FAVPost (2 NTRAN) + 1 data records, listed in Table 3, are required in the FAVPost input file, where each record may involve more than one line of data. A detailed description of each data record is given below.
Table 3. Record Keywords and Parameters for FAVPost Input File Record Keyword Field 1 Field 2 Field 3 1
CNTL NTRAN=[-]
Repeat data records 2 through 3 for each of the NTRAN transients 2
ITRN ITRAN=[-]
NHIST=[-]
ISEQ=[-]
3 input NHIST data lines with ( initiating frequency, probability density )
data pairs - one pair per line f init Density
[events/yr]
[% ]
Record 1 - CNTL Record No. 1 inputs the number of transients, NTRAN, for which initiating frequency probability density distributions (histograms) are being input.
Records 2 and 3 are repeated for each of the NTRAN transients.
Record 2 - ITRN Record 2 inputs the FAVOR transient number, ITRAN, the number of lines, NHIST, in Record 3 which contains the initiating frequency histogram (in terms of relative frequency), and the initiating-
69 sequence event number, ISEQ, from the thermal-hydraulic studies that supplied the transient for input to FAVOR.
Record 3 - Initiating Event Sequence Probability Density Functions (Histograms)
Input NHIST lines containing one histogram data pair per line, where the first field is the value of the transient initiating frequency in events per reactor-operating year and the second field is the probability density (as a relative frequency in percent).
EXAMPLE
- ALL RECORDS WITH AN ASTERISK (*) IN COLUMN 1 ARE COMMENT ONLY *
- EXAMPLE INPUT DATASET FOR FAVPost, v16.1 [UNITS]*
- ==================== *
- Record CNTL *
- ==================== *
- NTRAN = NUMBER OF T-H TRANSIENTS [-]
- CNTL NTRAN=6
- ==================== *
- Record ITRN *
- ==================== *
- ITRAN = TRANSIENT NUMBER [-] *
- NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION [-] *
- ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER [-]
- ITRN ITRAN=1 NHIST=19 ISEQ=3
- freq[events/year] Density [%]
0.000005730 0.50 0.000007380 0.50 0.000008760 1.50 0.000010100 2.50 0.000012300 5.00 0.000016100 10.00 0.000017700 5.00 0.000019400 5.00 0.000022700 10.00 0.000026100 10.00 0.000030000 10.00 0.000035100 10.00 0.000038100 5.00 0.000040800 5.00 0.000054300 10.00 0.000068700 5.00 0.000085300 2.50 0.000112000 1.50 0.000124000 1.00
- ==================== *
- Record ITRN *
- ==================== *
- ITRAN = PFM TRANSIENT NUMBER [-] *
- ITRAN = TRANSIENT NUMBER [-] *
- NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION [-] *
- ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER [-]
- ITRN ITRAN=2 NHIST=19 ISEQ=4
- freq[events/year] Density [%]
70 0.000000016 0.50 0.000000020 0.50 0.000000030 1.50 0.000000042 2.50 2.4 Content and Format for Flaw Distribution Databases By convention, flaws have been defined as Categories 1, 2, or 3 using the following designations:
(1) Category 1 - surface breaking flaws (2) Category 2 - embedded flaws in which the inner tip of the flaw is located between the clad-base interface and t/8 where t is the RPV wall thickness (3) Category 3 - embedded flaws in which the inner tip of the flaw is located between t/8 and 3t/8.
When executing the FAVPFM module, the user is prompted for three flaw-characterization files as follows: (1) inner surface-breaking flaws (2) embedded flaws in welds, and (3) embedded flaws in plates or forgings. The flaw-characterization file for inner-surface breaking flaws is applicable to both welds and plates/forgings.
The format is the following:
Each of the flaw-characterization files consists of 1000 file records, where each file record has 100 rows and several columns. The first and second columns in each row are:
Column (1) - the integer row number Column (2) - the flaw density corresponding to a flaw depth equal to (row number/100)
- vessel wall thickness.
For example, the flaw density in the 1st row corresponds to flaw depths of 1/100th of the RPV wall thickness, the flaw density in the 19th row corresponds to flaw depths of (0.19)(wall thickness),
etc.
The remaining columns are a probability distribution function (histogram) of aspect ratios (ratio of flaw length to flaw depth); i.e., each flaw depth has its own probability distribution of flaw length as will be discussed in more detail below.
2.4.1 Method of Quantifying Uncertainty in Flaw Characterization The method used to quantify the uncertainty in the flaw characterization is to include 1000 flaw-characterization file records for each of the three flaw data files (surface-breaking, weld embedded, and plate embedded) discussed above. Each of these file records contains separate flaw-density, flaw-
71 size, and aspect-ratio distributions with the format as discussed above. The format for the three characterization files is discussed in more detail below.
During the Monte Carlo PFM analysis, the RPV flaw-characterization data for the 1st stochastically-generated RPV trial are taken from the 1st group of file records, i.e., the first inner-surface breaking file record, the first embedded-flaw weld material file record, and the first embedded-flaw plate material file record. The RPV flaw characterization for the 2nd stochastically generated RPV trial is determined from the 2nd group of file records, etc. The RPV trials cycle through the flaw-characterization file records sequentially up to 1000, and then restarts at the first file record.
2.4.2 Flaw-Characterization File Names and Sizes The flaw-characterization file for inner-surface-breaking flaws is 100,000 rows with 5 columns. The name of the example ASCII text file in the distribution package is S.DAT with a size of 7.0 MBytes. The flaw-characterization file for embedded flaws in welded regions is 100,000 rows with 13 columns. The name of this ASCII text file on the distribution disk is W.DAT with a size of 15.2 MBytes. The flaw-characterization file for embedded flaws in plate regions is 100,000 rows with 13 columns. The name of this ASCII text file on the distribution disk is P.DAT, and its size is 15.2 MBytes. The distribution package also includes flaw-characterization files that are specific to the four plants under study in the PTS Re-evaluation Program, specifically BVsurf.DAT, BVweld.DAT, and BVplate.DAT for Beaver Valley, S_CC.DAT, W_CC.DAT, and P_CC.DAT for Calvert Cliffs, OCsurf.DAT, OCweld.DAT, and OCplate.DAT for Oconee, and PLsurf.DAT, PLweld.DAT, and PLplate.DAT for Palisades.
2.4.3 Surface Breaking Flaws (Flaw Category 1)
A more detailed explanation of the format of the surface breaking flaw data is given by way of example:
Histogram of Aspect ratio (AR)
(%)
AR=2 AR=6 AR=10 AR=infinite 1
density of flaw depths 1/100 RPV thickness 35.0 30.0 20.0 15.0 2
density of flaw depths 2/100 RPV thickness 40.0 30.0 25.0 5.0 3
density of flaw depths 3/100 RPV thickness density of flaw depths = RPV thickness 1
density of flaw depths 1/100 RPV thickness 2
density of flaw depths 2/100 RPV thickness 3
density of flaw depths 3/100 RPV thickness 100 density of flaw depths = RPV thickness
72
- through the 1000th file As illustrated above, for each flaw depth, there is a histogram for the aspect ratio (flaw depth / length) where the bins are aspect ratios of 2, 6, 10, and infinity. The reason for these specific aspect ratios is that they correspond to the flaw geometries for which stress intensity factor influence coefficients were generated and implemented into the FAVLoad module. The histograms will be sampled during the PFM analysis to stochastically determine the aspect ratio for the corresponding sampled flaw depth.
The FORTRAN subroutine in the FAVPFM module that reads the file containing flaw characteri-zation data for inner-surface breaking flaws is:
SUBROUTINE RDSURF(ISMAX)
C+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
IMPLICIT REAL*8 (A-H,O-Z)
C***********************************************************************
C*** ***
C*** Revisions: ***
C*** ***
C*** Date l Modification ***
C***============l==================================================***
C*** ***
C*** ***
C*** ***
C***********************************************************************
C***********************************************************************
C SUBROUTINE RDSURF READS DATA FROM THE FILE THAT CHARACTERIZES
- C SURFACE-BREAKING FLAWS (CATEGORY 1 FLAWS) AND IS APPLICABLE TO
- C BOTH WELD AND PLATE REGIONS.
- C
- C THE UNITS OF THE CATEGORY 1 SURFACE-BREAKING FLAWS ARE FLAWS PER
- C SQUARE FOOT OF AREA ON THE INNER SURFACE OF THE RPV.
- C
- C THE (I,J) ENTRY READ INTO ARRAY WDEPTH(100,1,IFILE) IS THE FLAW
- C DENSITY OF INNER-SURFACE BREAKING FLAWS (CATEGORY 1 FLAWS) THAT
- C HAVE A DEPTH OF (i/100)*WALL THICKNESS.
- C
- C SINCE THE DATA IS ALSO APPLICABLE TO PLATE MATERIAL, THE SAME DATA
- C IS READ INTO PDEPTH(100,1,IFILE)
- C***********************************************************************
INTEGER :: IVER, IERR C=======================================================================
COMMON /PROG/WDEPTH (100, 3,1000),WELDCAT(3,1000),PLATCAT(3,1000),
& WCATCDF(100, 3,1000),WSUM(3,1000), PSUM (3,1000),
& WCATPDF(100, 3,1000),PDEPTH (100, 3,1000),
& PCATCDF(100, 3,1000),PCATPDF (100, 3,1000),
& WFLASPT(100,12,1000),PFLASPT (100,12,1000),
& WASPCDF(100,12,1000),PASPCDF (100,12,1000),
& SFLASPT(100, 4,1000),SASPCDF (100, 4,1000)
C======================================================================
REAL*8, PARAMETER :: ZERO=0.
C======================================================================
WRITE (*,1004)
WRITE (*,8769) 1004 FORMAT (' ' )
8769 FORMAT (11X,' READING AND PROCESSING SURFACE-BREAKING',
& ' FLAW DATABASE')
C***********************************************************************
C READ THE SURFACE-BREAKING FLAW CHARACTERIZATION FILE. THE FORMAT OF
- C THIS FILE IS:
- C
- C K, FLAW DENSITY, FOLLOWED BY 4 NUMBERS THAT ARE A HISTOGRAM OF
- C ASPECT RATIOS FOR FLAWS OF THIS DEPTH WHERE THE HISTOGRAM IS
- C EXPRESSED IN PERCENT. A CDF WILL BE CONSTRUCTED FOR EACH OF THE
- C HISTOGRAMS THAT CAN BE SAMPLED DURING THE PFM ANALYSIS TO
- 73 C APPROPRIATELY POSTULATE ASPECT RATIO FOR SURFACE BREAKING
- C (CATEGORY 1) FLAWS.
- C
- C THE CORRESPONCE BETWEEN THE POSITION (OUT OF THE 4 BINS) AND THE
- C ASPECT RATIO IS AS FOLLOWS:
- C
- C BIN NUMBER ASPECT ARRAY
- C RATIO LOCATION
- C
- C 1 2 SFLASPT(J,1,IFILE)
- C 2 6 SFLASPT(J,2,IFILE)
- C 3 10 SFLASPT(J,3,IFILE)
- C 4 INFINITE SFLASPT(J,4,IFILE)
- C
- C J VARIES FROM 1==>100 TO COVER THE ENTIRE RANGE OF POSSIBLE FLAW
- C DEPTHS
- C
- C IFILE VARIES FROM 1==> 1000 TO COVER THE ENTIRE RANGE OF WELD
- C SURFACE BREAKING FLAW CHARACTERIZATION FILES USED TO INCLUDE THE
- C QUANTIFICATION OF UNCERTAINTY.
- C***********************************************************************
READ (48,*) IVER if (IVER.NE. 161) then call xermsg ('FAVPFM','RDSURF',
& 'SURFACE-BREAKING FLAW FILE NOT VERSION 15.1',17,1) call xerdmp call xerabt('xerror -- invalid input',23) endif ISMAX = 0 DO 10 IFILE=1,1000 DO 20 J=1,100 READ (48,*,IOSTAT=IERR) K,WDEPTH(J,1,IFILE),
& SFLASPT(J,1,IFILE),SFLASPT(J,2,IFILE),
& SFLASPT(J,3,IFILE),SFLASPT(J,4,IFILE)
IF (IERR.NE. 0) GOTO 998 PDEPTH(J,1,IFILE) = WDEPTH(J,1,IFILE)
IF (WDEPTH(J,1,IFILE).GT. ZERO) THEN IF (J.GT.ISMAX) ISMAX = J ENDIF 20 CONTINUE 10 CONTINUE GOTO 999 C=======================================================================
998 CONTINUE write(*,1000) IFILE, J, IFILE*J, IERR 1000 FORMAT(/'IFILE=',I4,' K=',I4,' LINE NUMBER=',I5,' IERR=',I4/)
call xermsg ('FAVPFM','RDSURF',
& 'ERROR READING SURFACE-BREAKING FLAW DATA',18,1) call xerdmp call xerabt('xerror -- invalid input',23)
C=======================================================================
999 CONTINUE C
RETURN END where WDEPTH (1:100, 1:3, 1:1000) is an array in FAVPFM in which the (J,1,IFILE) address contains flaw densities of Category 1 (surface breaking flaws) for welds and PDEPTH (1:100,1:3,1:1000) is a three-dimensional array in which the (J,1,IFILE) address contains flaw densities of Category 1 (surface breaking flaws) for plates/forgings.
SFLASPT (1:100,1:4,1:1000) is an array in FAVPFM in which the (J,1,IFILE) address contains the percentage of flaws with an aspect ratio of 2, the (J,2,IFILE) address contains the percentage of flaws with an aspect ratio of 6, the (J,3,IFILE) address contains the percentage of flaws with an aspect ratio of 10, and the (J,4,IFILE) address contains the percentage of flaws with an aspect ratio of infinity.
74 Inner-surface breaking flaws with a depth less than the clad thickness are not considered as candidates for cleavage initiation since the austenitic stainless steel cladding plane-strain cleavage fracture toughness is considerably more ductile than the ferritic base metal. Also, all inner-surface breaking flaws are assumed to be circumferentially oriented (even if the flaw is located in an axially oriented weld or plate) since all inner-surface breaking flaws are assumed to be a result of the process in which the cladding was applied.
2.4.4 Embedded flaw Characterization for Welds (Categories 2 and 3 flaws)
As with Category 1 surface breaking flaws, the first and second columns in each row are (1) the integer row number and (2) the flaw density corresponding to a flaw depth equal to (row number/100)
- vessel wall thickness, and the remaining columns are a probability distribution function (histogram) of aspect ratios (ratio of flaw length to flaw depth). Again, a more detailed explanation of the format of the inner-surface breaking flaw data is given by way of example as follows:
Histogram of Aspect ratio (AR)
(11 bins)
(%)
1 density of flaw depths t/100 2
density of flaw depths 2t/100 RPV thickness 3
density of flaw depths 3t/100 RPV thickness density of flaw depths = RPV thickness 1
density of flaw depths t/100 RPV thickness 2
density of flaw depths 2t/100 RPV thickness density of flaw depths 3t/100 RPV thickness density of flaw depths = RPV thickness
- through 1000th file The FORTRAN subroutine in the FAVPFM module that reads the file containing flaw characteri-zation data for embedded flaws in welds is as follows:
C+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
SUBROUTINE RDWELD(IWMAX)
C+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
IMPLICIT REAL*8 (A-H,O-Z)
C***********************************************************************
C*** ***
C*** Revisions: ***
C*** ***
C*** Date l Modification ***
C***============l==================================================***
C*** ***
C*** ***
C*** ***
C***********************************************************************
C***********************************************************************
C SUBROUTINE RDWELD READS DATA FROM THE FILE THAT CHARACTERIZES
- C EMBEDDED FLAWS POSTULATED TO RESIDE IN WELD REGIONS.
- C
- C THIS SUBROUTINE READS THE FLAW CHARACTERIZATION FLAW DATA FOR
- C EMBEDDED FLAWS IN WELD MATERIAL INTO ARRAYS THAT WILL BE SAMPLED
- C DURING THE PFM ANALYSIS TO STOCHASTICALLY POSTULATE FLAWS
- C IN THE RPV A MANNER CONSISTENT WITH THE FLAW CHARACTERIZATION.
- 75 C
- C THE (I,J) ENTRY READ INTO ARRAY WDEPTH(100,1,IFILE) IS THE FLAW
- C DENSITY OF INNER-SURFACE BREAKING FLAWS (CATEGORY 1 FLAWS) THAT
- C HAVE A DEPTH OF (i/100)*WALL THICKNESS. THIS READ IS PERFORMED IN
- C SUBROUTINE RDSURF. THE UNITS OF THIS FLAW DENSITY ARE FLAWS PER
- C SQUARE FOOT OF AREA ON THE INNER SURFACE OF THE RPV.
- C
- C THE (I,J) ENTRY READ INTO ARRAY WDEPTH(100,2,IFILE) IS THE FLAW
- C DENSITY OF CATEGORY 2 EMBEDDED FLAWS (EMBEDDED FLAWS SUCH THAT
- C THE INNER FLAW TIP RESIDES IN THE FIRST 1/8 OF THE WALL THICKNESS)
- C THAT HAVE A THROUGH-WALL DEPTH OF (i/100)*WALL THICKNESS. THE
- C UNITS OF THIS FLAW DENSITY ARE FLAWS PER SQUARE FOOT OF WELD
- C FUSION LINE AREA (ON ONE SIDE OF THE WELD).
- C
- C THE (I,J) ENTRY READ INTO ARRAY WDEPTH(100,3,IFILE) IS THE FLAW
- C DENSITY OF CATEGORY 3 EMBEDDED FLAWS (EMBEDDED FLAWS SUCH THAT
- C THE INNER FLAW TIP RESIDES IN BETWEEN 1/8 T AND 3/8 T) THAT HAVE
- C A THROUGH-WALL DEPTH OF (i/100)*WALL THICKNESS. THE UNITS OF THIS
- C FLAW DENSITY ARE FLAWS PER SQUARE FOOT OF WELD FUSION LINE AREA
- C (ON ONE SIDE OF THE WELD).
- C
- C THE EMDEDDED FLAW DENSITY FOR WELD MATERIAL IS ASSUMED TO BE
- C UNIFORM THROUGH THE WALL THICKNESS; THEREFORE THE DENSITY FOR
- C CATEGORY 3 EMBEDDED FLAWS WOULD BE IDENTICAL TO THE DENSITY FOR
- C CATEGORY 2 EMBEDDED FLAWS.
- C
- C THE METHOD TO INCLUDE THE UNCERTAINTY IN THE WELD FLAW
- C CHARACTERIZATION IS TO INCLUDE MULTIPLE (1000) FILES, EACH WITH
- C THE FORMAT DESCRIBED ABOVE, EACH WITH DIFFERENT DENSITIES, SIZE
- C AND ASPECT DISTRIBUTIONS, AND FLAW SIZE TRUNCATIONS.
- C***********************************************************************
COMMON /PROG/WDEPTH (100, 3,1000),WELDCAT(3,1000),PLATCAT(3,1000),
& WCATCDF(100, 3,1000), WSUM(3,1000), PSUM(3,1000),
& WCATPDF(100, 3,1000), PDEPTH (100, 3,1000),
& PCATCDF(100, 3,1000), PCATPDF(100, 3,1000),
& WFLASPT(100,12,1000), PFLASPT(100,12,1000),
& WASPCDF(100,12,1000), PASPCDF(100,12,1000),
& SFLASPT(100, 4,1000), SASPCDF(100, 4,1000)
C======================================================================
DIMENSION NDIV(1000)
C***********************************************************************
INTEGER :: IVER, IERR, IFILE, J, IWMAX C***********************************************************************
REAL*8, PARAMETER :: ZERO=0.
C***********************************************************************
WRITE (*,8769) 8769 FORMAT (12X,' READING AND PROCESSING WELD',
& ' EMBEDDED-FLAW DATABASE')
C***********************************************************************
C READ THE WELD FLAW CHARACTERIZATION FILE, THE FORMAT OF THIS FILE IS:*
C
- C K, FLAW DENSITY, FOLLOWED BY 11 NUMBERS THAT ARE ASPECT RATIOS
- C THE 11 NUMBERS ARE A HISTOGRAM OF ASPECT RATIO FOR FLAWS OF THIS
- C DEPTH
- C
- C WHERE:
- C
- C FLAW DENSITY IS EXPRESSED IN FLAWS PER CUBIC FOOT OF RPV MATERIAL
- C
- C THE HISTOGRAM IS EXPRESSED IN PERCENT. A CDF WILL BE CONSTRUCTED
- C FOR EACH OF THE HISTOGRAMS THAT CAN BE SAMPLED TO DETERMINE ASPECT
- C RATIO.
- C
- C THE CORRESPONCE BETWEEN THE POSITION (OUT OF THE 11 BINS) AND THE
- C ASPECT RATIO (l/2a) IS AS FOLLOWS:
- C
- C BIN NUMBER RANGE OF ARRAY
- C ASPECT RATIO LOCATION
- C
- C 1 1.00 - 1.25 WFLASPT(J,1,IFILE)
- C 2 1.25 - 1.50 WFLASPT(J,2,IFILE)
- C 3 1.50 - 2.00 WFLASPT(J,3,IFILE)
- C 4 2.00 - 3.00 WFLASPT(J,4,IFILE)
- C 5 3.00 - 4.00 WFLASPT(J,5,IFILE)
- C 6 4.00 - 5.00 WFLASPT(J,6,IFILE)
- C 7 5.00 - 6.00 WFLASPT(J,7,IFILE)
- C 8 6.00 - 8.00 WFLASPT(J,8,IFILE)
- C 9 8.00 - 10.0 WFLASPT(J,9,IFILE)
- C 10 10.0 - 15.0 WFLASPT(J,10,IFILE)
- C 11 > 15.0 WFLASPT(J,11,IFILE)
- C
- 76 C J VARIES FROM 1==>100 TO COVER THE ENTIRE RANGE OF POSSIBLE
- C FLAW DEPTHS
- C
- C IFILE VARIES FROM 1==> 1000 TO COVER THE ENTIRE RANGE OF WELD
- C FLAW CHARACTERIZATION FILES USED TO INCLUDE THE QUANTIFICATION
- C OF UNCERTAINTY.
- C***********************************************************************
READ (49,*) IVER if ( IVER.NE. 161 ) then call xermsg ('FAVPFM','RDWELD',
& 'EMBEDDED-FLAW WELD FILE NOT VERSION 15.1',19,1) call xerdmp call xerabt('xerror -- invalid input',23) endif IWMAX = 0 DO 210 IFILE=1,1000 DO 220 J=1,100 READ (49,*,IOSTAT=IERR) K,
& WDEPTH (J, 2,IFILE),WFLASPT(J, 1,IFILE),
& WFLASPT(J, 2,IFILE),WFLASPT(J, 3,IFILE),
& WFLASPT(J, 4,IFILE),WFLASPT(J, 5,IFILE),
& WFLASPT(J, 6,IFILE),WFLASPT(J, 7,IFILE),
& WFLASPT(J, 8,IFILE),WFLASPT(J, 9,IFILE),
& WFLASPT(J,10,IFILE),WFLASPT(J,11,IFILE)
IF (IERR.NE. 0) GOTO 998 WDEPTH(J,3,IFILE) = WDEPTH(J,2,IFILE)
IF (WDEPTH (J,2,IFILE).GT. ZERO) THEN IF (J.GT.IWMAX) IWMAX = J ENDIF 220 CONTINUE 210 CONTINUE GOTO 999 998 CONTINUE write(*,1000) IFILE, J, IFILE*J, IERR call xermsg ('FAVPFM','RDWELD',
& 'ERROR READING WELD EMB. FLAW DATA',20,1) call xerdmp call xerabt('xerror -- invalid input',23)
C 999 CONTINUE RETURN 1000 FORMAT(/'IFILE=',I4,' K=',I4,' LINE NUMBER=',I5,' IERR=',I4/)
END where WDEPTH (1:100,1:3,1:1000) is an array in FAVPFM in which the (J,2,IFILE) and the (J,3,IFILE) addresses contain flaw densities for Category 2 and Category 3 flaws, respectively, for welds.
WFLASPT(1:100,1:11,1:1000) is an array in FAVPFM in which the (J,1,IFILE) address contains the percentage of flaws with an aspect ratio between 1.00 and 1.25, and the (J,2,IFILE) address contains the percentage of flaws with an aspect ratio between 1.25 and 1.50. The range of aspect ratios corresponding to each of the 11 bins used to develop the histogram that will be sampled for each flaw depth is given in the following table.
Bin Number Range of flaw aspect ratio 1
1.00 - 1.25 2
1.25 - 1.50 3
1.50 - 2.00 4
2.00 - 3.00 5
3.00 - 4.00
77 6
4.00 - 5.00 7
5.00 - 6.00 8
6.00 - 8.00 9
8.00 - 10.0 10 10.0 - 15.0 11
> 15 2.4.5 Embedded-Flaw Characterization for Plates The data format for embedded flaws in plates/forgings is identical to that described above for embedded flaws in welds. The following subroutine reads in the characterization file for embedded flaws in plates.
C+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
SUBROUTINE RDPLAT(THICK,IPMAX,RO,RI)
C+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
IMPLICIT REAL*8 (A-H,O-Z)
C***********************************************************************
C*** ***
C*** Revisions: ***
C*** ***
C*** Date l Modification ***
C***============l==================================================***
C*** ***
C*** ***
C*** ***
C***********************************************************************
C***********************************************************************
C DEFINITION OF ARRAYS:
- C
- C PDEPTH(100,3,1000) - HOLDS DATA AS READ FROM EXTERNAL FILE
- C CONTAINING FLAW DATA FOR PLATE C
- C PLATCAT(3,1000) -CDF FROM WHICH FLAW CATEGORY IS SAMPLED FOR FLAW
- C LOCATED IN PLATE MATERIAL
- C
- C PCATPDF(100,3) HISTOGRAM EXPRESSING RELATIVE FREQUENCY OF PLATE
- C FLAW DENSITIES FOR EACH FLAW CATEGORY
- C
- C PCATCDF(100,3) CDF FOR EACH OF THE 3 FLAW CATEGORIES FOR PLATE
- C EACH COLUMN IS OBTAINED BY INTEGRATING PCATPDF
- C***********************************************************************
COMMON /PROG/WDEPTH (100, 3,1000),WELDCAT(3,1000),PLATCAT(3,1000),
& WCATCDF(100, 3,1000), WSUM(3,1000), PSUM(3,1000),
& WCATPDF(100, 3,1000), PDEPTH (100, 3,1000),
& PCATCDF(100, 3,1000), PCATPDF(100, 3,1000),
& WFLASPT(100,12,1000), PFLASPT(100,12,1000),
& WASPCDF(100,12,1000), PASPCDF(100,12,1000),
& SFLASPT(100, 4,1000), SASPCDF(100, 4,1000)
C***********************************************************************
INTEGER :: IVER, IERR C***********************************************************************
REAL*8, PARAMETER :: ZERO=0.
C***********************************************************************
WRITE (*,9835) 9835 FORMAT (12X,' READING AND PROCESSING PLATE EMBEDDED-FLAW',
& ' DATABASE')
C***********************************************************************
C READ THE PLATE FLAW CHARACTERIZATION FILE
- C***********************************************************************
C***********************************************************************
C THE DATA PROVIDED BY PNL ASSUME THAT THE DENSITY OF PLATE EMBEDDED
- C FLAWS ARE UNIFORM THROUGH THE WALL; THEREFORE, THE FLAW DENSITY
- C FOR CATEGORY 3 FLAWS IS IDENTICAL TO THAT FOR CATEGORY 2 FLAWS.
- C***********************************************************************
READ (39,*) IVER if ( IVER.NE. 161 ) then call xermsg ('FAVPFM','RDPLAT',
& 'EMBEDDED-FLAW PLATE FILE NOT VERSION 15.1',21,1) call xerdmp call xerabt('xerror -- invalid input',23) endif
78 IPMAX = 0 DO 110 IFILE=1,1000 DO 120 J=1,100 READ (39,*,IOSTAT=IERR) K,
& PDEPTH (J, 2,IFILE),PFLASPT(J, 1,IFILE),
& PFLASPT(J, 2,IFILE),PFLASPT(J, 3,IFILE),
& PFLASPT(J, 4,IFILE),PFLASPT(J, 5,IFILE),
& PFLASPT(J, 6,IFILE),PFLASPT(J, 7,IFILE),
& PFLASPT(J, 8,IFILE),PFLASPT(J, 9,IFILE),
& PFLASPT(J,10,IFILE),PFLASPT(J,11,IFILE)
PDEPTH(J,3,IFILE) = PDEPTH(J,2,IFILE)
IF (IERR.NE. 0) GOTO 998 IF (PDEPTH (J,2,IFILE).GT. ZERO ) THEN IF (J.GT.IPMAX) IPMAX=J ENDIF 120 CONTINUE 110 CONTINUE GOTO 999 998 CONTINUE write(*,1000) IFILE, J, IFILE*J, IERR 1000 FORMAT(/'IFILE=',I4,' K=',I4,' LINE NUMBER=',I5,' IERR=',I4/)
call xermsg ('FAVPFM','RDPLAT',
& 'ERROR READING PLATE EMB. FLAW DATA',22,1) call xerdmp call xerabt('xerror -- invalid input',23) 999 CONTINUE C***********************************************************************
C DETERMINE THE TOTAL FLAW DENSITY FOR EACH OF THE 3 FLAW CATEGORIES:
- C
- C PSUM(1,IFILE) = TOTAL FLAW DENSITY FOR CATEGORY 1 FLAWS IN PLATES
- C PSUM(2,IFILE) = TOTAL FLAW DENSITY FOR CATEGORY 2 FLAWS IN PLATES
- C PSUM(3,IFILE) = TOTAL FLAW DENSITY FOR CATEGORY 3 FLAWS IN PLATES
- C***********************************************************************
DO 15 IFILE=1,1000 DO 20 J=1,100 PSUM(1,IFILE) = PSUM(1,IFILE) + PDEPTH(J,1,IFILE)
PSUM(2,IFILE) = PSUM(2,IFILE) + PDEPTH(J,2,IFILE)
PSUM(3,IFILE) = PSUM(3,IFILE) + PDEPTH(J,3,IFILE) 20 CONTINUE 15 CONTINUE C***********************************************************************
C GENERATE PROBABILITY DISTRIBUTION FUNCTION (PCATCDF), IN THIS CASE
- C A RELATIVE FREQUENCY HISTOGRAM OF PLATE FLAW DENSITIES FOR EACH
- C OF THE 3 FLAW CATEGORIES.
- C
- C COLUMN 1 OF ARRAY PCATPDF IS A RELATIVE FREQ HIST FOR CAT 1 FLAWS
- C COLUMN 2 OF ARRAY PCATPDF IS A RELATIVE FREQ HIST FOR CAT 2 FLAWS
- C COLUMN 3 OF ARRAY PCATPDF IS A RELATIVE FREQ HIST FOR CAT 3 FLAWS
- C***********************************************************************
DO 80 K=1,3 DO 91 IFILE=1,1000 DO 90 J=1,100 IF (PSUM(K,IFILE).NE.ZERO) THEN PCATPDF(J,K,IFILE) = PDEPTH(J,K,IFILE)/PSUM(K,IFILE)
ENDIF 90 CONTINUE 91 CONTINUE C***********************************************************************
C GENERATE CUMULATIVE DISTRIBUTION FUNCTION (PCATCDF)FOR EACH OF
- C THE 3 FLAW CATEGORIES BY INTEGRATING THE PROBABILITY DISTRIBUTION
- C THE FLAW SIZE OF A FLAW IN ITS RESPECTIVE CATEGORY
- C
- C COLUMN 1 OF ARRAY PCATCDF CONTAINS THE CDF FOR CATEGORY 1 FLAWS
- C COLUMN 2 OF ARRAY PCATCDF CONTAINS THE CDF FOR CATEGORY 2 FLAWS
- C COLUMN 3 OF ARRAY PCATCDF CONTAINS THE CDF FOR CATEGORY 3 FLAWS
- C***********************************************************************
DO 95 IFILE=1,1000 PCATCDF(1,K,IFILE) = PCATPDF(1,K,IFILE)
DO 97 J=2,100 PCATCDF(J,K,IFILE) = PCATCDF(J-1,K,IFILE) +
& PCATPDF(J,K,IFILE) 97 CONTINUE 95 CONTINUE 80 CONTINUE RETURN END
79 2.4.6 Total Number of Flaws Surface breaking flaw density data are expressed in flaws per unit RPV-surface area and weld subregion embedded flaws are flaws per unit area on the fusion line between the weld and adjacent plate subregions. These conventions are consistent with the physical model utilized by Pacific Northwest National Laboratory to derive the flaw characterization data input to FAVOR. Embedded flaws in plate regions are expressed on a volumetric basis.
Figure 17a and 17b illustrate axial and circumferential weld subregion elements, respectively. The number of flaws in each of these weld elements is calculated (internally by FAVOR) as the sum of the number of inner-surface breaking flaws and the number of embedded flaws as follows:
Number of Flaws 2
2 in Weld Subregions 360 1 when surface-breaking flaws are located on either inner or external vessel surface only 2 when surface-breaking flaws a SB i
EW R dz d dA
re located on both inner and external vessel surfaces 3/8 when embedded flaws with inner crack tip residing in either the inner or outer 3/8 of base metal thickness are included in PFM analysis 1 w
2 hen all through-wall embedded flaws are included in PFM analysis inner surface-breaking flaw density (per unit surface area - flaws/in )
weld embedded-flaw density (per unit weld-fusion area -
SB EW
2 2
flaws/in )
user-input weld-fusion area (for one side of weld) (in - input by user) internal radius of RPV (in. - input by user) height of subregion element (in. - input by user) subtend i
dA R
dz d
ed angle of subregion element ( degrees - input by user)
(7) where SB
and EW
are summed over all flaw depths.
For axial welds, the fusion lines are on the sides of the weld, whereas for circumferential welds, the fusion lines are on the top and bottom of the welds. In the term
2 dA
, the factor of 2 accounts for the fact that the user input data is the area on one side of the fusion line whereas flaws reside in fusion lines on both sides of the welds. The variable depends on the user-specified option regarding which flaw population is to be included in the analysis. All embedded flaw densities are assumed to be uniform through the RPV wall thickness.
80 Figure 17c illustrates a plate subregion element. The number of flaws in each of these plate elements is calculated (internally by FAVOR) as the sum of the number of surface-breaking flaws and the number of embedded flaws as follows:
2 2
Number of Flaws 2
in Plate Subregions 360 360 1 when surface-breaking flaws are located on either inner or external vessel surface only (us SB i
EP o
i d
R dz d R
R CLTH dz
er-specified option) 2 when surface-breaking flaws are located on both inner and external vessel surfaces (user-specified option) 3/8 when embedded flaws with inner crack tip residing in either the
inner or outer 3/8 of base metal thickness are included in PFM analysis 1 when all through-wall embedded flaws are included in PFM analysis inner surface-breaking flaw density (per unit surface SB
2 3
area - flaws/in )
plate embedded-flaw density summed over all flaw depths (flaws per unit volume - flaws/in )
external radius of RPV (in - input by user) internal radius of RPV (in. - i EP o
i R
R
nput by user) cladding thickness (in. - input by user) height of subregion element (in. - input by user) subtended angle of subregion element
( degrees - input by user)
CLTH dz d
(8) where SB
and EP
are summed over all flaw depths.
2.5 FAVOR Load Module - FAVLoad Output FAVLoad creates two output files - (1) the load definition file (user-defined filename at time of execution) that will be input to FAVPFM (*.out) and (2) *.echo which provides a date and time stamp of the execution and an echo of the FAVLoad input file. The following page gives a partial listing of a typical FAVLoad *.echo file. The name of the FAVLoad *.echo is constructed from the root of the FAVLoad output file with.echo extension added, e.g., FAVLoad.out FAVLoad.echo.
81 FAVLoad.echo
- WELCOME TO FAVOR *
- FRACTURE ANALYSIS OF VESSELS: OAK RIDGE *
- VERSION 16.1 *
- FAVLOAD MODULE: LOAD GENERATOR *
- PROBLEMS OR QUESTIONS REGARDING FAVOR *
- SHOULD BE DIRECTED TO *
- TERRY DICKSON *
- OAK RIDGE NATIONAL LABORATORY *
- e-mail: dicksontl@ornl.gov *
- This computer program was prepared as an account of *
- work sponsored by the United States Government *
- Neither the United States, nor the United States *
- Department of Energy, nor the United States Nuclear *
- Regulatory Commission, nor any of their employees, *
- nor any of their contractors, subcontractors, or their *
- employees, makes any warranty, expressed or implied, or *
- assumes any legal liability or responsibility for the *
- accuracy, completeness, or usefulness of any *
- information, apparatus, product, or process disclosed, *
- or represents that its use would not infringe *
- privately-owned rights.
- FAVLOAD INPUT DATASET NAME = favload2.in FAVLOAD OUTPUT DATASET NAME = favload2.out FAVLOAD ECHO INPUT FILE NAME = favload2.echo
- ECHO OF FAVLOAD INPUT FILE *
- Example Heat-up transients *
- Note: These transients are not to be taken as actual postulated transients *
- but are constructed for purely illustrative purposes such that *
- several flaws are initiated thus illustrating (and verifying) the *
- PFM output reports. *
- ==================== *
- Record GEOM *
- ==================== *
- IRAD = INTERNAL RADIUS OF PRESSURE VESSEL [IN] *
- W = THICKNESS OF PRESSURE VESSEL WALL (INCLUDING CLADDING) [IN] *
- CLTH = CLADDING THICKNESS [IN]
- GEOM IRAD=86.0 W=8.75 CLTH=0.25
- =========================== *
- Records BASE and CLAD *
- =========================== *
- THERMO-ELASTIC MATERIAL PROPERTIES FOR BASE AND CLADDING *
- K = THERMAL CONDUCTIVITY [BTU/HR-FT-F] *
- C = SPECIFIC HEAT [BTU/LBM-F] *
- RHO = DENSITY [LBM/FT**3] *
- E = YOUNG'S ELASTIC MODULUS [KSI] *
- ALPHA = THERMAL EXPANSION COEFFICIENT [F**-1] *
- NU = POISSON'S RATIO [-] *
- NTE = TEMPERATURE DEPENDANCY FLAG *
- NTE = 0==> PROPERTIES ARE TEMPERATURE INDEPENDENT (CONSTANT) *
- NTE = 1==> PROPERTIES ARE TEMPERATURE DEPENDENT *
- IF NTE EQUAL TO 1, THEN ADDITIONAL DATA RECORDS ARE REQUIRED
- BASE K=24.0 C=0.120 RHO=489.00 E=28000 ALPHA=.00000777 NU=0.3 NTE=1
- THERMAL CONDUCTIVITY TABLE
82 2.6 FAVOR PFM Module - FAVPFM Output FAVPFM produces the following files:
General Output Files (1) Filename defined by user at execution (e.g., FAVPFM.OUT)
(2) Echo of input file with filename defined by user at execution (e.g., FAVPFM.echo)
(3) Binary restart file - restart.bin Input files for FAVPost (4) FAILURE.DAT (5) INITIATE.DAT QA Verification Files (6) ARREST.OUT (7) FLAWNO.OUT (8) FLAWSIZE.OUT (9) TRACE.OUT (10) FLAW_TRACK.LOG (11) History_itran_iseq.out (NTRAN files where itran is the FAVOR transient number and iseq is its associated and unique thermal-hydraulic initiating-event sequence number)
The following pages present partial listings of example files: (1) FAVPFM.OUT, (2) FAVPFM.echo, (6) ARREST.OUT, (7) FLAWNO.OUT, (8) FLAWSIZE.OUT, (9) TRACE.OUT, (10) FLAW_TRACK.LOG, and (11) History_itran_iseq.out.
FAVPFM.echo includes two sections:
(1) Echo of all input data from FAVPFM.IN file.
(2) Summary of structure of Major Regions and Subregions FAVPFM.out includes results for all transients in this case definition including:
Mean value of conditional probability of initiation (CPI)
Mean value of conditional probability of failure (CPF)
Mean value of RTNDT at crack tip Flaw distribution report by material and category Weld Flaw-Size Distribution Report Plate Flaw-Size Distribution Report Transient Time Distribution Report Multiple Flaw Statistics
83 FAVPFM.echo
- WELCOME TO FAVOR *
- FRACTURE ANALYSIS OF VESSELS: OAK RIDGE *
- VERSION 16.1 *
- FAVPFM MODULE: PERFORMS PROBABILISTIC *
- FRACTURE MECHANICS ANALYSES *
- PROBLEMS OR QUESTIONS REGARDING FAVOR *
- SHOULD BE DIRECTED TO *
- TERRY DICKSON *
- OAK RIDGE NATIONAL LABORATORY *
- e-mail: dicksontl@ornl.gov *
- This computer program was prepared as an account of *
- work sponsored by the United States Government *
- Neither the United States, nor the United States *
- Department of Energy, nor the United States Nuclear *
- Regulatory Commission, nor any of their employees, *
- nor any of their contractors, subcontractors, or their *
- employees, makes any warranty, expressed or implied, or *
- assumes any legal liability or responsibility for the *
- accuracy, completeness, or usefulness of any *
- information, apparatus, product, or process disclosed, *
- or represents that its use would not infringe *
- privately-owned rights.
- FAVPFM INPUT FILE NAME = favpfm2.in FAVLOAD OUTPUT FILE NAME = favload2.out FAVPFM OUTPUT FILE NAME = favpfm2.out FAVPFM INPUT ECHO FILE NAME = favpfm2.echo no./col.
1.......10........20........30........40........50........60........70........80........90.......100.......110.......120.....
..130 1 **********************************************************************************************************
2
- ALL RECORDS WITH AN ASTERISK(*) IN COLUMN 1 ARE COMMENT ONLY
- 3 **********************************************************************************************************
4
- EXAMPLE INPUT DATASET FOR FAVPFM, v16.1 - Small EMBRITTLEMENT MAP subjected to multiple heat-up
- 5
- 6 **********************************************************************************************************
7 *====================
- 8
- Control Record CNT1
- 9 *====================
- 10 *--------------------------------------------------------------------------------------------------------*
11
- NSIM = NUMBER OF RPV SIMULATIONS
- 12 *--------------------------------------------------------------------------------------------------------*
13
- IPFLAW = FLAW POPULATION MODEL
- 14 *
- 15
- IPFLAW = 1 Identical to previous version of FAVOR - primarily for cooldown transients.
- 16 *
- 17
- All Surface flaws (in surface flaw characterizatiuon file) will be inner surface
- 18
- breaking flaws. Only those embedded flaws (in weld and plate flaw characterization
- 19
- files) in the inner 3/8 of the RPV wall thickness would be included in the model.
- 20 *
- 21
- IPFLAW = 2 Similar to previous version of FAVOR-HT - primarily for heat-up transients.
- 22 *
- 23
- All surface breaking flaws (in surface flaw characterization file) would be
- 24
- external surface breaking flaws. Only those embedded flaws in the outer 3/8 of the
- 25
- RPV wall thickness would be included in the model.
- 26 *
- 27
- It should be noted that the 09.1 version is not able to propagate external flaws
- 28
- surface-breaking flaws through-the-thickness toward the inner surface to determine
- 29
- if they cause failure; therefore, for IPFLAW=2, this version of FAVOR is only
- 30
- capable of calculating the conditional probability of initiation but not the
- 31
- conditional probability of vessel failure; therefore, the CPF will be zero.
- 32 *
- 33
- Note: It is recommended that if the vessel model is postulated to contain surface
- 34
- breaking flaws that IPFLAW=2 not be used, but rather IPFLAW=3, since, based on
- 35
- experience, inner surface breaking flaws can also be predicted to initiate
- 36
- during a heat-up transient. IPFLAW=3 postulates and equal number of surface
- 37
- breaking flaws on the vessel inner surface and the vessel outer surface.
- 38 *
- 39
- IPFLAW = 3 The number of postulated surface breaking flaws (in surface flaw characterization
- 40
- file) would be double that of options 1 and 2; evenly divided between internal
- 41
- and external surface breaking flaws. All of the embedded flaws uniformly
- 42
- distributed through the RPV wall thickness would be included in the model.
- 43 *
- 44
- See Theory Manual for further discussion.
- 45 *--------------------------------------------------------------------------------------------------------*
46
- IGATR = NUMBER OF INITIATION-GROWTH-ARREST (IGA) TRIALS PER FLAW
- 47 *--------------------------------------------------------------------------------------------------------*
48
- WPS_OPTION = 0 DO NOT INCLUDE WARM-PRESTRESSING IN ANALYSIS
- 49
- WPS_OPTION = 1 INCLUDE TRADITIONAL FAVOR BASELINE WARM-PRESTRESSING Model IN ANALYSIS
- 50
- WPS OPTION 2 INCLUDE Conservative Principal WARM PRESTRESSING MODEL IN ANALYSIS
- 84 FAVPFM.out
- WELCOME TO FAVOR *
- FRACTURE ANALYSIS OF VESSELS: OAK RIDGE *
- VERSION 16.1 *
- FAVPFM MODULE: PERFORMS PROBABILISTIC *
- FRACTURE MECHANICS ANALYSES *
- PROBLEMS OR QUESTIONS REGARDING FAVOR *
- SHOULD BE DIRECTED TO *
- TERRY DICKSON *
- OAK RIDGE NATIONAL LABORATORY *
- e-mail: dicksontl@ornl.gov *
- This computer program was prepared as an account of *
- work sponsored by the United States Government *
- Neither the United States, nor the United States *
- Department of Energy, nor the United States Nuclear *
- Regulatory Commission, nor any of their employees, *
- nor any of their contractors, subcontractors, or their *
- employees, makes any warranty, expressed or implied, or *
- assumes any legal liability or responsibility for the *
- accuracy, completeness, or usefulness of any *
- information, apparatus, product, or process disclosed, *
- or represents that its use would not infringe *
- privately-owned rights.
- FAVPFM INPUT FILE NAME = favpfm2.in FAVLOAD OUTPUT FILE NAME = favload2.out FAVPFM OUTPUT FILE NAME = favpfm2.out FAVPFM INPUT ECHO FILE NAME = favpfm2.echo Binary restart files will be created using a checkpoint interval of 200 trials.
NUMBER OF TIME STEPS IN FAVLoad FILE = 301 NUMBER OF IGA TRIALS PER FLAW = 100 FLOW STRESS - USED IN FAILURE ANALYSIS = 80.0 ksi Maximum value used for KIc and KIa = 800.0 ksi-in^1/2 KIc/KIa cap not used if ductile-tearing model is invoked.
Stochastic model for crack arrest KIa = 2 where 1 = model based on high-constraint CCA specimens 2 = model based on CCA and large-specimen data KIa model set to 2 if ductile-tearing model is invoked.
Radiation embrittlement correlation = 2006 where 992 = Regulatory Guide 1.99, revision 2 2000 = Eason 2000 2006 = Eason 2006 20071 = EricksonKirk 2007 20072 = RADAMO 2007 20073 = Combined EricksonKirk 2007 + RADAMO 2007 Steady-state cooling water temperature = 556. degrees F Effective full-power years of operation = 60.
DEFINITION OF STANDARD DEVIATIONS FOR SIMULATING THE FOLLOWING PARAMETERS SURFACE NEUTRON FLUENCE - GLOBAL = 0.118* BEST ESTIMATE VALUE SURFACE NEUTRON FLUENCE - LOCAL = 0.056* BEST ESTIMATE VALUE COPPER - WELD = 0.167 wt %
COPPER - PLATE = 0.0073 wt %
NICKEL - PLATE = 0.0244 wt %
PHOSPHORUS - WELD = 0.0013 wt %
PHOSPHORUS - PLATE = 0.0013 wt %
NUMBER OF VESSEL SUBREGIONS: WELD= 15 PLATE= 18 TOTAL= 33 NUMBER OF VESSEL MAJOR REGIONS: WELD= 7 PLATE= 6 TOTAL= 13 SURF-BREAKING FLAW CHARACTERIZATION DATASET FILE NAME = S.DAT EMBEDDED WELD FLAW CHARACTERIZATION DATASET FILE NAME = W.DAT EMBEDDED PLATE FLAW CHARACTERIZATION DATASET FILE NAME = P.DAT
- PFM ANALYSIS RESULTS
- 85 FAVPFM.OUT (continued)
- PFM ANALYSIS RESULTS *
- INITIAL RANDOM NUMBER GENERATOR SEEDS : 1234567890 123456789 *
- IPFLAW=2: SURFACE BREAKING FLAWS ARE **
- EXTERNAL SURFACE BREAKING **
- EMBEDDED FLAWS ARE UNIFORMLY **
- DISTRIBUTED IN OUTER 3/8 OF RPV BASE **
- WELD LAYER RESAMPLING TURNED OFF **
- WARM-PRESTRESS OPTION 1 CHOSEN: **
- TO HAVE A NON-ZERO instantaneous conditional **
- probability of crack initiation at a discrete **
- transient time step: **
- applied KI must be greater than the Weibull **
- "a" parameter **
- AND **
- applied KI MUST EXCEED MAXIMUM KI at all **
- previous discrete transient time steps **
- DO NOT ANALYZE CATEGORY 3 PLATE FLAWS **
- DUCTILE TEARING MODEL TURNED ON **
- FAILURE CRITERIA a/t = 0.90 **
- PFM RESULTS FOR TRANSIENT NUMBER 1 **
- NUMBER OF COMPLETED TRIALS = 100 **
MEAN VALUE OF CPI = 1.766E-04 MEAN VALUE OF CPF = 1.766E-04
- RPV BELTLINE MAJOR REGION REPORT *
- BY PARENT SUBREGION *
========================================================================================
l---Initiation---l l----Cleavage----l l------Ductile-----l MAJOR RTndt % OF SIMULATED # of FLAWS % of # of FLAWS % of # of FLAWS % of REGION (MAX) FLAWS FLAWS CPI > 0 CPI CPF > 0 CPF CPF > 0 CPF
========================================================================================
1 277.6 3.15 15873 6 98.96 6 98.96 0 0.00 2 277.6 3.15 16107 6 0.25 6 0.25 0 0.00 3 272.0 3.15 15914 1 0.29 1 0.29 0 0.00 4 271.9 1.88 9547 1 0.00 1 0.00 0 0.00 5 277.3 1.88 9432 2 0.00 2 0.00 0 0.00 6 277.3 1.88 9549 4 0.50 4 0.50 0 0.00 7 261.7 21.76 109923 0 0.00 0 0.00 0 0.00 8 178.6 13.18 66292 0 0.00 0 0.00 0 0.00 9 207.3 13.18 66335 0 0.00 0 0.00 0 0.00 10 179.5 13.18 66258 0 0.00 0 0.00 0 0.00 11 154.4 7.87 39518 0 0.00 0 0.00 0 0.00 12 185.9 7.87 40018 0 0.00 0 0.00 0 0.00 13 140.4 7.87 39801 0 0.00 0 0.00 0 0.00
========================================================================================
TOTALS 100.00 504567 20 100.00 20 100.00 0 0.00
========================================================================================
NOTE: MEAN VALUE OF RTNDT AT CRACK TIP= 143.63
- RPV BELTLINE MAJOR REGION REPORT *
- BY CHILD SUBREGION *
========================================================================================
l---Initiation---l l----Cleavage----l l------Ductile-----l MAJOR RTndt % OF SIMULATED # of FLAWS % of # of FLAWS % of # of FLAWS % of REGION (MAX) FLAWS FLAWS CPI > 0 CPI CPF > 0 CPF CPF > 0 CPF
========================================================================================
1 277.6 3.15 15873 6 98.96 6 98.96 0 0.00 2 277.6 3.15 16107 6 0.25 6 0.25 0 0.00 3 272.0 3.15 15914 1 0.29 1 0.29 0 0.00 4 271.9 1.88 9547 1 0.00 1 0.00 0 0.00 5 277 3 1 88 9432 2 0 00 2 0 00 0 0 00
86 FAVPFM.OUT (continued)
- RPV BELTLINE MAJOR REGION REPORT *
- BY PARENT SUBREGION *
========================================================================================
l---Initiation---l l----Cleavage----l l------Ductile-----l MAJOR RTndt % OF SIMULATED # of FLAWS % of # of FLAWS % of # of FLAWS % of REGION (MAX) FLAWS FLAWS CPI > 0 CPI CPF > 0 CPF CPF > 0 CPF
========================================================================================
1 277.6 3.15 15873 2 94.86 2 94.86 0 0.00 2 277.6 3.15 16107 2 1.47 2 1.47 0 0.00 3 272.0 3.15 15914 1 2.77 1 2.77 0 0.00 4 271.9 1.88 9547 1 0.00 1 0.00 0 0.00 5 277.3 1.88 9432 1 0.89 1 0.89 0 0.00 6 277.3 1.88 9549 0 0.00 0 0.00 0 0.00 7 261.7 21.76 109923 0 0.00 0 0.00 0 0.00 8 178.6 13.18 66292 0 0.00 0 0.00 0 0.00 9 207.3 13.18 66335 0 0.00 0 0.00 0 0.00 10 179.5 13.18 66258 0 0.00 0 0.00 0 0.00 11 154.4 7.87 39518 0 0.00 0 0.00 0 0.00 12 185.9 7.87 40018 0 0.00 0 0.00 0 0.00 13 140.4 7.87 39801 0 0.00 0 0.00 0 0.00
========================================================================================
TOTALS 100.00 504567 7 100.00 7 100.00 0 0.00
========================================================================================
NOTE: MEAN VALUE OF RTNDT AT CRACK TIP= 143.63
- RPV BELTLINE MAJOR REGION REPORT *
- BY CHILD SUBREGION *
========================================================================================
l---Initiation---l l----Cleavage----l l------Ductile-----l MAJOR RTndt % OF SIMULATED # of FLAWS % of # of FLAWS % of # of FLAWS % of REGION (MAX) FLAWS FLAWS CPI > 0 CPI CPF > 0 CPF CPF > 0 CPF
========================================================================================
1 277.6 3.15 15873 2 94.86 2 94.86 0 0.00 2 277.6 3.15 16107 2 1.47 2 1.47 0 0.00 3 272.0 3.15 15914 1 2.77 1 2.77 0 0.00 4 271.9 1.88 9547 1 0.00 1 0.00 0 0.00 5 277.3 1.88 9432 1 0.89 1 0.89 0 0.00 6 277.3 1.88 9549 0 0.00 0 0.00 0 0.00 7 261.7 21.76 109923 0 0.00 0 0.00 0 0.00 8 178.6 13.18 66292 0 0.00 0 0.00 0 0.00 9 207.3 13.18 66335 0 0.00 0 0.00 0 0.00 10 179.5 13.18 66258 0 0.00 0 0.00 0 0.00 11 154.4 7.87 39518 0 0.00 0 0.00 0 0.00 12 185.9 7.87 40018 0 0.00 0 0.00 0 0.00 13 140.4 7.87 39801 0 0.00 0 0.00 0 0.00
========================================================================================
TOTALS 100.00 504567 7 100.00 7 100.00 0 0.00 FOR IPFLAW = 2: CATEGORY 1 FLAWS ARE ON THE EXTERNAL SURFACE CATEGORY 2 FLAWS ARE EMBEDDED IN EXTERNAL 1/8 OF BASE METAL THICKSS CATEGORY 3 FLAWS ARE EMBEDDED BETWEEN EXTERNAL 1/8 AND EXTERNAL 3/8 OF BASE METAL THICKNESS
- FLAW DISTRIBUTION BY MATERIAL AND CATEGORY *
- BY PARENT SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
FLAW CATEGORY 1(ext) 2 0 0.00 0 0.00 FLAW CATEGORY 2(ext) 62174 3 1.47 3 1.47 FLAW CATEGORY 3(ext) 124169 4 98.53 4 98.53
======================================
TOTALS 186345 7 100.00 7 100.00
======================================
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
FLAW CATEGORY 1(ext) 173 0 0.00 0 0.00 FLAW CATEGORY 2(ext) 106448 0 0.00 0 0.00 FLAW CATEGORY 3(ext) 211601 0 0.00 0 0.00
======================================
TOTALS 318222 0 0.00 0 0.00
87 FAVPFM.OUT (continued)
- FLAW DISTRIBUTION BY MATERIAL, CATEGORY, & ORIENTATION *
- BY PARENT SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 2 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 25599 3 1.47 3 1.47 AXIAL FLAW CATEGORY 3 50821 4 98.53 4 98.53
======================================
AXIAL SUBTOTALS 76422 7 100.00 7 100.00
======================================
CIRC. FLAW CATEGORY 1 0 0 0.00 0 0.00 CIRC. FLAW CATEGORY 2 36575 0 0.00 0 0.00 CIRC. FLAW CATEGORY 3 73348 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 109923 0 0.00 0 0.00
======================================
WELD TOTALS 186345 7 100.00 7 100.00
======================================
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 87 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 53103 0 0.00 0 0.00 AXIAL FLAW CATEGORY 3 105922 0 0.00 0 0.00
======================================
AXIAL SUBTOTALS 159112 0 0.00 0 0.00
======================================
CIRC. FLAW CATEGORY 1 86 0 0.00 0 0.00 CIRC. FLAW CATEGORY 2 53345 0 0.00 0 0.00 CIRC. FLAW CATEGORY 3 105679 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 159110 0 0.00 0 0.00
======================================
PLATE TOTALS 318222 0 0.00 0 0.00
======================================
======================================
- FLAW DISTRIBUTION BY MATERIAL, CATEGORY, & ORIENTATION *
- BY CHILD SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 2 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 25599 3 1.47 3 1.47 AXIAL FLAW CATEGORY 3 50821 4 98.53 4 98.53
======================================
AXIAL SUBTOTALS 76422 7 100.00 7 100.00
======================================
CIRC. FLAW CATEGORY 1 0 0 0.00 0 0.00 CIRC. FLAW CATEGORY 2 36575 0 0.00 0 0.00 CIRC. FLAW CATEGORY 3 73348 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 73348 0 0.00 0 0.00
======================================
WELD TOTALS 149770 7 100.00 7 100.00
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 87 0 0.00 0 0.00
88 FAVPFM.OUT (continued)
- FLAW DISTRIBUTION BY MATERIAL, CATEGORY, & ORIENTATION *
- BY CHILD SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 2 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 25599 3 1.47 3 1.47 AXIAL FLAW CATEGORY 3 50821 4 98.53 4 98.53
======================================
AXIAL SUBTOTALS 76422 7 100.00 7 100.00
======================================
CIRC. FLAW CATEGORY 1 0 0 0.00 0 0.00 CIRC. FLAW CATEGORY 2 36575 0 0.00 0 0.00 CIRC. FLAW CATEGORY 3 73348 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 73348 0 0.00 0 0.00
======================================
WELD TOTALS 149770 7 100.00 7 100.00
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 87 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 53103 0 0.00 0 0.00 AXIAL FLAW CATEGORY 3 105922 0 0.00 0 0.00
======================================
AXIAL SUBTOTALS 159112 0 0.00 0 0.00
======================================
CIRC. FLAW CATEGORY 1 86 0 0.00 0 0.00 CIRC. FLAW CATEGORY 2 53345 0 0.00 0 0.00 CIRC. FLAW CATEGORY 3 105679 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 159110 0 0.00 0 0.00
======================================
PLATE TOTALS 318222 0 0.00 0 0.00 CHILD SUBREGION REPORTS SHOW LOCATIONS OF CONTROLLING RTNDTO AND CHEMISTRY CONTENT FOR WELD FUSION LINES
- WELD FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF INITIATION *
=============================================================
flaw simulated # % of simulated # % of simulated # % of depth catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPI>0 CPI flaws CPI>0 CPI flaws CPI>0 CPI
=============================================================
0.088 0 0 0.00 33008 0 0.00 66174 0 0.00 0.175 0 0 0.00 23497 0 0.00 46770 0 0.00 0.263 2 0 0.00 4559 0 0.00 8893 0 0.00 0.350 0 0 0.00 690 0 0.00 1383 0 0.00 0.438 0 0 0.00 180 0 0.00 452 0 0.00 0.525 0 0 0.00 116 0 0.00 213 0 0.00 0.613 0 0 0.00 56 0 0.00 113 0 0.00 0.700 0 0 0.00 26 0 0.00 75 0 0.00 0.787 0 0 0.00 12 0 0.00 31 0 0.00 0.875 0 0 0.00 8 0 0.00 24 0 0.00 0.963 0 0 0.00 3 0 0.00 11 0 0.00 1.050 0 0 0.00 8 1 1.07 11 0 0.00 1.137 0 0 0.00 4 0 0.00 2 0 0.00 1.225 0 0 0.00 0 0 0.00 2 1 94.56 1.312 0 0 0.00 3 1 0.40 4 0 0.00 1.400 0 0 0.00 2 0 0.00 4 0 0.00 1.488 0 0 0.00 0 0 0.00 3 0 0.00 1.575 0 0 0.00 0 0 0.00 0 0 0.00 1.663 0 0 0.00 0 0 0.00 0 0 0.00 1.750 0 0 0.00 1 1 0.00 1 0 0.00 1.837 0 0 0.00 0 0 0.00 0 0 0.00 1.925 0 0 0.00 0 0 0.00 0 0 0.00 2.013 0 0 0.00 0 0 0.00 1 1 0.89 2.100 0 0 0.00 0 0 0.00 1 1 0.30 2.188 0 0 0.00 1 0 0.00 0 0 0.00 2.275 0 0 0.00 0 0 0.00 1 1 2.77 2.363 0 0 0.00 0 0 0.00 0 0 0.00 2.450 0 0 0.00 0 0 0.00 0 0 0.00
89 FAVPFM.OUT (continued)
- PLATE FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF INITIATION *
=============================================================
flaw simulated # % of simulated # % of simulated # % of depth catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPI>0 CPI flaws CPI>0 CPI flaws CPI>0 CPI
=============================================================
0.088 0 0 0.00 39767 0 0.00 78996 0 0.00 0.175 0 0 0.00 49049 0 0.00 97132 0 0.00 0.263 173 0 0.00 13265 0 0.00 26590 0 0.00 0.350 0 0 0.00 3337 0 0.00 6788 0 0.00 0.438 0 0 0.00 919 0 0.00 1849 0 0.00 0.525 0 0 0.00 58 0 0.00 136 0 0.00 0.613 0 0 0.00 53 0 0.00 110 0 0.00
=============================================================
TOTALS 173 0 0.00 106448 0 0.00 211601 0 0.00
=============================================================
- WELD FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF FAILURE *
=============================================================
flaw simulated # % of simulated # % of simulated # % of depth catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPF>0 CPF flaws CPF>0 CPF flaws CPF>0 CPF
=============================================================
0.088 0 0 0.00 33008 0 0.00 66174 0 0.00 0.175 0 0 0.00 23497 0 0.00 46770 0 0.00 0.263 2 0 0.00 4559 0 0.00 8893 0 0.00 0.350 0 0 0.00 690 0 0.00 1383 0 0.00 0.438 0 0 0.00 180 0 0.00 452 0 0.00 0.525 0 0 0.00 116 0 0.00 213 0 0.00 0.613 0 0 0.00 56 0 0.00 113 0 0.00 0.700 0 0 0.00 26 0 0.00 75 0 0.00 0.787 0 0 0.00 12 0 0.00 31 0 0.00 0.875 0 0 0.00 8 0 0.00 24 0 0.00 0.963 0 0 0.00 3 0 0.00 11 0 0.00 1.050 0 0 0.00 8 1 1.07 11 0 0.00 1.137 0 0 0.00 4 0 0.00 2 0 0.00 1.225 0 0 0.00 0 0 0.00 2 1 94.56 1.312 0 0 0.00 3 1 0.40 4 0 0.00 1.400 0 0 0.00 2 0 0.00 4 0 0.00 1.488 0 0 0.00 0 0 0.00 3 0 0.00 1.575 0 0 0.00 0 0 0.00 0 0 0.00 1.663 0 0 0.00 0 0 0.00 0 0 0.00 1.750 0 0 0.00 1 1 0.00 1 0 0.00 1.837 0 0 0.00 0 0 0.00 0 0 0.00 1.925 0 0 0.00 0 0 0.00 0 0 0.00 2.013 0 0 0.00 0 0 0.00 1 1 0.89 2.100 0 0 0.00 0 0 0.00 1 1 0.30 2.188 0 0 0.00 1 0 0.00 0 0 0.00 2.275 0 0 0.00 0 0 0.00 1 1 2.77 2.363 0 0 0.00 0 0 0.00 0 0 0.00 2.450 0 0 0.00 0 0 0.00 0 0 0.00 2.537 0 0 0.00 0 0 0.00 0 0 0.00 2.625 0 0 0.00 0 0 0.00 0 0 0.00 2.712 0 0 0.00 0 0 0.00 0 0 0.00 2.800 0 0 0.00 0 0 0.00 0 0 0.00 2.888 0 0 0.00 0 0 0.00 0 0 0.00 2.975 0 0 0.00 0 0 0.00 0 0 0.00
=============================================================
TOTALS 2 0 0.00 62174 3 1.47 124169 4 98.53
=============================================================
- PLATE FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF FAILURE *
=============================================================
flaw simulated # % of simulated # % of simulated # % of
90 FAVPFM.OUT (continued)
===================================
- TRANSIENT TIME DISTRIBUTION REPORT *
- for transient sequence 2 *
===================================
TIME TIME % of CDF of % of CDF of STEP (min) total total total total CDCPI CDCPI CDCPF CDCPF
===================================
1 0.0 4.8353 4.8353 4.8353 4.8353 6 5.0 0.0083 4.8436 0.0083 4.8436 7 6.0 0.0687 4.9123 0.0687 4.9123 10 9.0 0.0539 4.9662 0.0539 4.9662 11 10.0 0.1129 5.0791 0.1129 5.0791 14 13.0 0.0537 5.1328 0.0537 5.1328 15 14.0 0.0917 5.2246 0.0917 5.2246 19 18.0 0.0154 5.2400 0.0154 5.2400 20 19.0 0.0306 5.2706 0.0306 5.2706 21 20.0 0.0227 5.2933 0.0227 5.2933 22 21.0 0.0145 5.3078 0.0145 5.3078 23 22.0 0.0060 5.3139 0.0060 5.3139 28 27.0 0.1290 5.4429 0.1290 5.4429 142 141.0 0.0000 5.4429 0.0000 5.4429 143 142.0 0.0000 5.4429 0.0000 5.4429 145 144.0 0.0002 5.4431 0.0002 5.4431 146 145.0 0.0005 5.4436 0.0005 5.4436 148 147.0 0.0010 5.4446 0.0010 5.4446 149 148.0 0.0020 5.4466 0.0020 5.4466 150 149.0 0.0033 5.4498 0.0033 5.4498 152 151.0 0.0037 5.4536 0.0037 5.4536 153 152.0 0.0063 5.4599 0.0063 5.4599 154 153.0 0.0085 5.4683 0.0085 5.4683 155 154.0 0.0109 5.4793 0.0109 5.4793 156 155.0 0.0137 5.4929 0.0137 5.4929 157 156.0 0.0166 5.5095 0.0166 5.5095 158 157.0 0.0197 5.5293 0.0197 5.5293 159 158.0 0.0230 5.5523 0.0230 5.5523 160 159.0 0.0723 5.6246 0.0723 5.6246 161 160.0 0.0364 5.6610 0.0364 5.6610 162 161.0 0.0400 5.7010 0.0400 5.7010 163 162.0 0.0436 5.7446 0.0436 5.7446 164 163.0 0.1350 5.8796 0.1350 5.8796 165 164.0 0.0584 5.9380 0.0584 5.9380 166 165.0 0.1832 6.1212 0.1832 6.1212 167 166.0 0.0730 6.1942 0.0730 6.1942 168 167.0 0.2351 6.4293 0.2351 6.4293 169 168.0 0.0861 6.5154 0.0861 6.5154 170 169.0 0.2888 6.8042 0.2888 6.8042 171 170.0 0.3334 7.1376 0.3334 7.1376 172 171.0 0.1054 7.2430 0.1054 7.2430 173 172.0 0.3868 7.6298 0.3868 7.6298 174 173.0 0.4323 8.0621 0.4323 8.0621 175 174.0 0.4780 8.5401 0.4780 8.5401 176 175.0 0.5233 9.0634 0.5233 9.0634 177 176.0 0.5679 9.6313 0.5679 9.6313 178 177.0 0.6115 10.2429 0.6115 10.2429 179 178.0 1.2385 11.4813 1.2385 11.4813 180 179.0 0.7423 12.2236 0.7423 12.2236 181 180.0 0.7796 13.0032 0.7796 13.0032 182 181.0 1.5957 14.5989 1.5957 14.5989 183 182.0 0.8918 15.4908 0.8918 15.4908 184 183.0 1.8545 17.3452 1.8545 17.3452 185 184.0 2.0324 19.3777 2.0324 19.3777 186 185.0 1.0424 20.4201 1.0424 20.4201 187 186.0 2.2565 22.6766 2.2565 22.6766 188 187.0 2.4126 25.0891 2.4126 25.0891 189 188.0 2.5582 27.6473 2.5582 27.6473 190 189.0 4.3293 31.9766 4.3293 31.9766 191 190.0 2.9303 34.9069 2.9303 34.9069 192 191.0 3.0319 37.9388 3.0319 37.9388 193 192.0 5.1953 43.1341 5.1953 43.1341 194 193.0 3.2948 46.4289 3.2948 46.4289 195 194.0 5.7364 52.1653 5.7364 52.1653 196 195.0 6.0719 58.2372 6.0719 58.2372 197 196.0 6.3754 64.6126 6.3754 64.6126 198 197.0 6.6427 71.2553 6.6427 71.2553 199 198.0 10.2185 81.4737 10.2185 81.4737 200 199.0 7.2596 88.7333 7.2596 88.7333 201 200.0 11.2667 100.0000 11.2667 100.0000
91 FAVPFM.OUT (continued)
- PROBABILITY DISTRIBUTION FUNCTION (HISTOGRAM) *
- FOR THE INITIATING DRIVING FORCES *
- FOR TRANSIENT SEQUENCE 2 *
===================================
RELATIVE CUMULATIVE KI(ksi-in^1/2) DENSITY DISTRIBUTION (bin midpoint) (%) (%)
===================================
21.00 28.5714 28.5714 23.00 14.2857 42.8571 25.00 42.8571 85.7143 35.00 14.2857 100.0000
===================================
RELATIVE CUMULATIVE KI(ksi-in^1/2) DENSITY DISTRIBUTION (bin midpoint) (%) (%)
===================================
========================================================================================
FAILURE MECHANISM REPORT FOR TRANSIENT SEQUENCE 2
========================================================================================
NUMBER OF % OF TOTAL FAILURE FAILURE TRIALS TRIALS UNSTABLE DUCTILE TEARING 0 0.00 STABLE DUCTILE TEAR TO PLASTIC INSTABILITY 0 0.00 CLEAVAGE PROPAGATION TO PLASTIC INSTABILITY 0 0.00 STABLE DUCTILE TEAR EXCEEDS WALL DEPTH FAILURE CRITERIA 0 0.00 CLEAVAGE PROPAGATION EXCEEDS WALL DEPTH FAILURE CRITERIA 0 0.00
- MULTIPLE FLAW STATISTICS
- NUMBER OF OCCASIONS WHEN SIMULATED RPV HAD X FLAWS % OF X FLAWS % OF X FLAWS WITH CPI > 0 TOTAL CPI WITH CPF > 0 TOTAL CPF 1 21 87.50 21 87.50 2 3 12.50 3 12.50 TOTALS 24 100.00 24 100.00 Note: One Occasion is 1 simulated RPV subjected to 1 transient
92 TRACE.OUT file
==================================================================================================================l Flaws that Produce Vessel Failures l
==================================================================================================================l Parent Flaw l Category 1 l Category 2 l Category 3 l Orientation l itran irpv kflaw parent childl itran irpv kflaw parent childl itran irpv kflaw parent childl
============l=================================l=================================l=================================l axial weld l l 1 8 8500 2 2l 0 0 0 0 0l circ. weld l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l circ. plate l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l axial plate l l 0 0 0 0 0l 0 0 0 0 0l
============l=================================l=================================l=================================l
==================================================================================================================l Flaws that Experience Stable Arrests l
==================================================================================================================l Parent Flaw l Category 1 l Category 2 l Category 3 l Orientation l itran irpv kflaw parent childl itran irpv kflaw parent childl itran irpv kflaw parent childl
============l=================================l=================================l=================================l axial weld l l 1 16 7761 1 1l 0 0 0 0 0l circ. weld l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l circ. plate l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l axial plate l l 0 0 0 0 0l 0 0 0 0 0l
============l=================================l=================================l=================================l
==================================================================================================================l Flaws that Reinitiate l
==================================================================================================================l Parent Flaw l Category 1 l Category 2 l Category 3 l Orientation l itran irpv kflaw parent childl itran irpv kflaw parent childl itran irpv kflaw parent childl
============l=================================l=================================l=================================l axial weld l l 0 0 0 0 0l 0 0 0 0 0l circ. weld l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l circ. plate l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l axial plate l l 0 0 0 0 0l 0 0 0 0 0l
============l=================================l=================================l=================================l
==================================================================================================================l Flaws that Experience Stable Ductile Tearing l
==================================================================================================================l Parent Flaw l Category 1 l Category 2 l Category 3 l Orientation l itran irpv kflaw parent childl itran irpv kflaw parent childl itran irpv kflaw parent childl
============l=================================l=================================l=================================l axial weld l l 1 16 7761 1 1l 0 0 0 0 0l circ. weld l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l circ. plate l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l axial plate l l 0 0 0 0 0l 0 0 0 0 0l
============l=================================l=================================l=================================l
==================================================================================================================l Flaws that Experience Unstable Ductile Tearing l
==================================================================================================================l Parent Flaw l Category 1 l Category 2 l Category 3 l Orientation l itran irpv kflaw parent childl itran irpv kflaw parent childl itran irpv kflaw parent childl
============l=================================l=================================l=================================l axial weld l l 1 16 7761 1 1l 0 0 0 0 0l circ. weld l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l circ. plate l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l axial plate l l 0 0 0 0 0l 0 0 0 0 0l
============l=================================l=================================l=================================l
==================================================================================================================l Parent Flaw l Category 1 l Category 2 l Category 3 l Orientation l itran irpv kflaw parent childl itran irpv kflaw parent childl itran irpv kflaw parent childl
============l=================================l=================================l=================================l axial weld l l 2 1 1375 79 6493l 0 0 0 0 0l circ. weld l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l circ. plate l 0 0 0 0 0l 0 0 0 0 0l 0 0 0 0 0l axial plate l l 2 2 285 14936 14936l 0 0 0 0 0l
===========l=================================l=================================l=================================l
===========l=================================l=================================l=================================l
93 The flaw log tables are created only when ITRACK=1 on the TRAC record. These logged flaws are the first flaws sampled that meet the different criteria in the tables.
ITRAN =
transient number IRPV =
RPV simulation FLAW =
flaw number SUBREGION = subregion number SCU =
sampled Cu content wt%
SNI =
sampled Ni content wt%
SPHOS =
sampled P content wt%
SMN=
sampled Mn content wt%
SFID =
sampled/attenuated fluence 0( )
f r
19 2
10 neutrons/cm
at the crack tip RTNDTO =
sampled unirradiated 0
[ F]
DRTEPI =
sampled
[ F]
epistemic RT
epistemic uncertainty term in 0
sampled 30 [ F]
T
CVN shift term from Eason and Wright model SDRTNDT =
sampled irradiation shift [ F]
RTNDT =
sampled irradiated
[ F]
at crack tip FLAW CAT = flaw category DEPTH =
flaw depth, a [inches]
XINNER =
inner crack tip position for embedded flaws [inches]
ASPECT =
flaw aspect ratio I =
time increment counter TIME =
elapsed time in transient [minutes]
KI =
applied
[ksi in.]
I K
TEMP =
temperature at crack tip [ F]
CPI =
current conditional probability of initiation CDCPI =
current cpi
FAIL =
number of trials failing the vessel at this time increment CDCPF =
current cpf
at this time station CPFTOT =
CPF conditional probability of failure
94 FLAW_TRACK.LOG file The file FLAW_TRACK.LOG is created only when ITRACK=1 on TRAC record.
STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 520 parent subr= 696 child subr= 9610 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 658 parent subr= 812 child subr= 9451 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 817 parent subr= 671 child subr= 10776 REINITIATION :parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 1001 parent subr= 696 child subr= 9610 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 1 kflaw= 1375 parent subr= 79 child subr= 6493 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 1 kflaw= 1601 parent subr= 231 child subr= 7861 STABLE ARREST :parent axial weld category 2 flaw: itran= 1 irpv= 1 kflaw= 1957 parent subr= 118 child subr= 6532 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 2602 parent subr= 207 child subr= 9133 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 2736 parent subr= 674 child subr= 10776 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 1 kflaw= 2843 parent subr= 836 child subr= 10723 STABLE ARREST :parent axial weld category 2 flaw: itran= 2 irpv= 1 kflaw= 3471 parent subr= 141 child subr= 6502 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 3759 parent subr= 692 child subr= 9822 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 3788 parent subr= 463 child subr= 12949 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 1 kflaw= 3861 parent subr= 619 child subr= 8020 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 231 parent subr= 208 child subr= 9080 STABLE TEARING:parent axial plate category 2 flaw: itran= 1 irpv= 2 kflaw= 285 parent subr= 14936 child subr= 14936 STABLE ARREST :parent axial plate category 2 flaw: itran= 2 irpv= 2 kflaw= 430 parent subr= 8022 child subr= 8022 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 636 parent subr= 719 child subr= 8391 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 2 kflaw= 658 parent subr= 237 child subr= 7543 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 795 parent subr= 706 child subr= 9080 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 828 parent subr= 835 child subr= 10670 STABLE TEARING:parent circ. plate category 2 flaw: itran= 1 irpv= 2 kflaw= 837 parent subr= 9087 child subr= 9087 STABLE ARREST :parent axial plate category 2 flaw: itran= 1 irpv= 2 kflaw= 931 parent subr= 9243 child subr= 9243 STABLE ARREST :parent axial weld category 2 flaw: itran= 2 irpv= 2 kflaw= 1183 parent subr= 111 child subr= 6525 REINITIATION :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 1502 parent subr= 176 child subr= 10776 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 1647 parent subr= 764 child subr= 6907 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 2 kflaw= 1669 parent subr= 631 child subr= 8656 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 1691 parent subr= 672 child subr= 10829 VESSEL FAILURE:parent axial weld category 2 flaw: itran= 1 irpv= 2 kflaw= 1716 parent subr= 99 child subr= 6513 STABLE ARREST :parent axial weld category 2 flaw: itran= 2 irpv= 2 kflaw= 1795 parent subr= 158 child subr= 6519 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 2 kflaw= 1898 parent subr= 746 child subr= 6960 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 2125 parent subr= 703 child subr= 9239 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 2229 parent subr= 529 child subr= 14062 STABLE ARREST :parent circ. plate category 2 flaw: itran= 2 irpv= 2 kflaw= 2508 parent subr= 9302 child subr= 9302 STABLE ARREST :parent circ. plate category 2 flaw: itran= 2 irpv= 2 kflaw= 2607 parent subr= 6859 child subr= 6859 STABLE TEARING:parent axial plate category 2 flaw: itran= 1 irpv= 2 kflaw= 2775 parent subr= 10642 child subr= 10642 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 2 kflaw= 2805 parent subr= 593 child subr= 6642 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 2 kflaw= 3063 parent subr= 106 child subr= 6520 VESSEL FAILURE:parent axial weld category 2 flaw: itran= 1 irpv= 2 kflaw= 3191 parent subr= 90 child subr= 6504 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 3251 parent subr= 681 child subr= 10405 STABLE TEARING:parent axial plate category 2 flaw: itran= 1 irpv= 2 kflaw= 3416 parent subr= 10858 child subr= 10858 STABLE TEARING:parent axial plate category 2 flaw: itran= 1 irpv= 2 kflaw= 3467 parent subr= 9664 child subr= 9664 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 3726 parent subr= 835 child subr= 10670 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 3741 parent subr= 243 child subr= 7225 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4010 parent subr= 787 child subr= 8126 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4048 parent subr= 211 child subr= 8921 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4103 parent subr= 834 child subr= 10617 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4303 parent subr= 811 child subr= 9398 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4415 parent subr= 133 child subr= 6494 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4501 parent subr= 670 child subr= 10723 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 2 kflaw= 4626 parent subr= 81 child subr= 6495 STABLE ARREST :parent circ. plate category 1 flaw: itran= 1 irpv= 4 kflaw= 515 parent subr= 8907 child subr= 8907 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 4 kflaw= 4385 parent subr= 646 child subr= 9451 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 5 kflaw= 120 parent subr= 209 child subr= 9027 STABLE ARREST :parent circ. plate category 1 flaw: itran= 1 irpv= 5 kflaw= 291 parent subr= 12510 child subr= 12510 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 492 parent subr= 195 child subr= 9769 STABLE ARREST :parent axial weld category 2 flaw: itran= 1 irpv= 5 kflaw= 687 parent subr= 65 child subr= 3623 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 875 parent subr= 208 child subr= 9080 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 5 kflaw= 958 parent subr= 674 child subr= 10776 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 1122 parent subr= 679 child subr= 10511 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 5 kflaw= 1367 parent subr= 337 child subr= 974 STABLE TEARING:parent circ. plate category 1 flaw: itran= 1 irpv= 5 kflaw= 2110 parent subr= 10830 child subr= 10830 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 5 kflaw= 2652 parent subr= 104 child subr= 6518 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 2861 parent subr= 838 child subr= 10829 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 3094 parent subr= 415 child subr= 3388 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 5 kflaw= 3612 parent subr= 108 child subr= 6522 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 3839 parent subr= 179 child subr= 10617 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 5 kflaw= 4301 parent subr= 491 child subr= 14433 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 5 kflaw= 4428 parent subr= 142 child subr= 6503 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 5 kflaw= 4580 parent subr= 190 child subr= 10034 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 7 kflaw= 307 parent subr= 314 child subr= 1756 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 7 kflaw= 2820 parent subr= 312 child subr= 1824 STABLE TEARING:parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 257 parent subr= 672 child subr= 10829 STABLE ARREST :parent circ. plate category 2 flaw: itran= 1 irpv= 8 kflaw= 418 parent subr= 7812 child subr= 7812 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 978 parent subr= 511 child subr= 15016 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 8 kflaw= 983 parent subr= 160 child subr= 6521 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 1868 parent subr= 667 child subr= 10564 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 3119 parent subr= 190 child subr= 10034 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 3173 parent subr= 830 child subr= 10405 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 3244 parent subr= 215 child subr= 8709 STABLE TEARING:parent axial weld category 2 flaw: itran= 1 irpv= 8 kflaw= 3831 parent subr= 59 child subr= 3617 STABLE ARREST :parent circ. weld category 2 flaw: itran= 1 irpv= 8 kflaw= 4037 parent subr= 713 child subr= 8709 STABLE ARREST :parent circ. weld category 2 flaw: itran= 2 irpv= 8 kflaw= 4118 parent subr= 308 child subr= 1960
95 ARREST.OUT file (warm-prestress option turned off)
NTEST =
trial number in IGA model PF =
Pf value for this trial PROPA =
the flaw is propagating by cleavage fracture STEAR=
the flaw is extending by stable ductile tearing UTEAR=
the flaw has experienced an unstable ductile tearing event REINI=
the flaw has re-initiated by cleavage TREINI=
the flaw has re-initiated by ductile tearing ARRES =
the flaw is arrested STABLE=
the flaw has arrested or stopped tearing and is stable for this time step RECHM =
resample weld chemistry content; the flaw had advanced into the next weld layer SCU =
sampled Cu content wt%
SNI =
sampled Ni content wt%
SPHOS =
sampled P content wt%
SMN=
sample Mn content wt%
NFLAW =
flaw number TIME =
elapsed time in transient [minutes]
L =
node number in IGA model mesh ZSURF =
position of crack tip relative to inner surface [inches]
TEMP =
temperature at crack tip [ F
]
P =
scaled quantile in KIa statistical model
=================================================================================================================================
ARREST TRIAL = 1 PF = 0.56551 PARENT = 104 CHILD = 6518 XDEPTH = 0.1607 XINNER = 0.1618 IFLCAT = 2 ASPECT = 2.53
=================================================================================================================================
N.B. The variables DT30, DRTNDX, RTNDTA, RTNDT, TADJA, TADJI, KI, KIc, KIA, AND KJIc are evaluated at position ZSURF in the RPV wall.
=================================================================================================================================
NFLAW TIME L ZSURF TEMP P DT30 RTNDTO -DTEPA DTARR DRTNDX RTNDTA RTNDT TADJA TADJI KI KIC KIA KJIc KJR*
=================================================================================================================================
INITIA 2652 17.0 4 0.321 272.94 165.29 73.00 227.53 76.14
=================================================================================================================================
PROPA 2652 17.0 6 0.482 279.44 4.4E-01 164.62 73.00 13.83 59.00 181.08 326.91 226.79 -47.47 52.65 89.89 65.81 PROPA 2652 17.0 8 0.643 289.73 4.4E-01 163.95 73.00 13.83 59.00 180.34 326.18 226.05 -36.45 63.68 101.13 70.12 PROPA 2652 17.0 10 0.804 303.25 4.4E-01 163.28 73.00 13.83 59.00 179.61 325.44 225.32 -22.19 77.93 109.88 76.36 PROPA 2652 17.0 12 0.964 315.94 4.4E-01 162.61 73.00 13.83 59.00 178.87 324.71 224.58 -8.76 91.36 117.52 83.02 PROPA 2652 17.0 14 1.125 327.22 4.4E-01 161.95 73.00 13.83 59.00 178.14 323.98 223.85 3.24 103.36 124.41 89.70 PROPA 2652 17.0 16 1.286 337.43 4.4E-01 161.28 73.00 13.83 59.00 177.41 323.25 223.12 14.18 114.31 130.62 96.44 PROPA 2652 17.0 18 1.446 346.95 4.4E-01 160.62 73.00 13.83 59.00 176.68 322.52 222.39 24.43 124.56 136.20 103.39 PROPA 2652 17.0 20 1.607 356.15 4.4E-01 159.96 73.00 13.83 59.00 175.95 321.79 221.66 34.36 134.49 141.23 110.76 PROPA 2652 17.0 22 1.768 365.32 4.4E-01 159.29 73.00 13.83 59.00 175.22 321.06 220.93 44.26 144.39 145.78 118.80 PROPA 2652 17.0 24 1.929 374.43 4.4E-01 158.63 73.00 13.83 59.00 174.49 320.33 220.20 54.11 154.23 149.98 127.53 RECHM SCU = 0.172 SNI = 0.644 SPHOS= 0.014 SMN= 1.381 RESAMPLE NEXT WELD LAYER CHEMISTRY ARRES 2652 17.0 26 2.259 392.59 4.4E-01 126.30 73.00 13.83 59.00 138.93 284.77 184.64 107.82 207.95 158.17 191.51 TREINI 2652 17.5 27 2.509 399.48 4.4E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 115.79 207.95 159.63 1064.57 134.70 262.03 ARRES 2652 17.5 27 2.509 399.48 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 115.79 215.91 166.17 227.13 STABLE 2652 18.0 27 2.509 393.67 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 109.98 109.98 165.40 1241.32 134.30 262.03 STABLE 2652 18.5 27 2.509 387.98 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 104.29 104.29 164.41 1115.50 134.75 262.03 STABLE 2652 19.0 27 2.509 382.72 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 99.03 99.03 162.61 1011.90 135.17 262.03 STABLE 2652 19.5 27 2.509 378.14 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 94.45 94.45 159.78 930.79 135.55 262.03 STABLE 2652 20.0 27 2.509 373.98 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 90.29 90.29 159.65 863.39 135.90 262.03 STABLE 2652 20.5 27 2.509 369.77 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 86.08 86.08 164.64 800.91 136.26 262.03 STABLE 2652 21.0 27 2.509 365.55 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 81.86 81.86 159.45 743.59 136.62 262.03 STABLE 2652 21.5 27 2.509 361.71 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 78.02 78.02 160.25 695.59 136.96 262.03 STABLE 2652 22.0 27 2.509 358.29 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 74.60 74.60 157.22 655.90 137.27 262.03 STABLE 2652 22.5 27 2.509 355.12 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 71.43 71.43 155.14 621.60 137.55 262.03 STABLE 2652 23.0 27 2.509 352.18 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 68.49 68.49 155.28 591.63 137.83 262.03 STABLE 2652 23.5 27 2.509 349.14 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 65.45 65.45 154.81 562.51 138.11 262.03 STABLE 2652 24.0 27 2.509 346.10 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 62.41 62.41 151.44 535.10 138.39 262.03 STABLE 2652 24.5 27 2.509 343.38 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 59.69 59.69 149.40 512.04 138.65 262.03 STABLE 2652 25.0 27 2.509 340.82 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 57.13 57.13 148.66 491.41 138.90 262.03 STABLE 2652 25.5 27 2.509 338.05 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 54.36 54.36 148.07 470.25 139.17 262.03 STABLE 2652 26.0 27 2.509 335.10 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 51.41 51.41 145.78 448.92 139.46 262.03 STABLE 2652 26.5 27 2.509 332.33 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 48.64 48.64 144.47 430.05 139.74 262.03 STABLE 2652 27.0 27 2.509 329.67 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 45.98 45.98 144.27 412.86 140.01 262.03 STABLE 2652 27.5 27 2.509 326.74 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 43.05 43.05 143.56 394.96 140.31 262.03 STABLE 2652 28.0 27 2.509 323.66 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 39.97 39.97 141.90 377.22 140.63 262.03 STABLE 2652 28.5 27 2.509 320.73 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 37.04 37.04 140.75 361.27 140.93 262.03 STABLE 2652 80.0 27 2.509 179.20 5.7E-01 125.32 73.00 13.83 59.00 137.86 283.69 183.57 -104.49-104.49 42.60 88.08 157.50 262.03 STABLE ARREST
96 DT30=
sampled 30 T
shift due to irradiation [ F
]
RTNDTO =
sampled unirradiated value of RTNDT0 [ F
]
-DTEPA =
sampled
[ F]
epistemic arrest RT
epistemic uncertainty term in Arrest RT DTARR =
sampled
[ F]
Arrest RT
DRTNDX =
[ F]
irradiation shift RTNDTA =
[ F]
Arrest RT
arrest reference temperature used in KIa lognormal model RTNDT =
[ F]
irradiated reference temperature used in KIc Weibull model TADJA =
[ F]
RELATIVE T
temperature used in KIa lognormal model TADJ =
[ F]
RELATIVE T
temperature used in KIc Weibull model KI =
applied KI [ksi in.] driving force for crack KIC =
current value of KIc [ksi in.]
KIA =
current value of KIa [ksi in.]
KJIc=
current value of JIc converted to KJIc [ksi in.]
KJR*=
current value of R
J converted to KJR* [ksi in.]
USEI=
current value of irradiated upper-shelf CVN energy [ft-lbf]
C_DT=
coefficient for sampled JR curve where
DT m
R DT J
C a
[in-kips/in2]
m_DT=
exponent for sampled JR curve where
DT m
R DT J
C a
[-]
da0=
accumulated flaw advancement under stable ductile tearing [in]
P_T0=
cumulative probability used in sampling for T0 (IDT_OPTION=1)
P_JIc=
cumulative probability used in sampling for JIc (IDT_OPTION=1)
P_m=
cumulative probability used in sampling for m_DT (IDT_OPTION=1) sflow=
sampled flow stress [ksi]
97 ARREST.OUT file (continued) statistics at end of file
- STABLE ARREST STATISTICS
- NUMBER OF OCCASIONS WHEN SIMULATED RPV HAD X STABLE No. of CRACK ARRESTS RPVs 1 471 2 348 3 214 4 209 5 141 6 137 7 108 8 77 9 80 10 65 11 56 12 54 13 52 14 48 15 39 16 48 17 38 18 25 19 30 20 22 21 20 22 20 23 13 24 17 25 18 26 9 27 16 28 11 29 20 30 14 31 12 32 8 33 8 34 10 35 8 36 7 37 9 38 5 39 4 40 2 41 2 42 3 43 3 44 1 45 2 49 5 50 1 55 1 56 2 58 1 Note: One Occasion is 1 simulated RPV subjected to 1 transient
- HISTOGRAM OF CRACK DEPTHS AT WHICH STABLE ARRESTS *
- PREDICTED TO OCCUR FOR EACH TRANSIENT
- TRANSIENT NUMBER = 1 TRANSIENT SEQUENCE NUMBER= 7 DEPTH % OF STABLE ARRESTS 0.402 0.00 0.482 0.00 0.563 0.00 0.643 0.00 0.723 0.00 0 804 0 01
98 FLAWNO.OUT FAVPFM INPUT FILE NAME = favpfm.in FAVLOAD OUTPUT FILE NAME = FAVLoad.out SURF-BREAKING FLAW CHARACTERIZATION DATASET FILE NAME = S.DAT EMBEDDED WELD FLAW CHARACTERIZATION DATASET FILE NAME = W.DAT EMBEDDED PLATE FLAW CHARACTERIZATION DATASET FILE NAME = P.DAT FAVPFM OUTPUT FILE NAME = favpfm.out REPORTING FROM SUBROUTINE GEOMQA:
REPORT CLAD SURFACE AREA WHICH IS USED IN THE DETERMINATION OF THE NUMBER OF SURFACE BREAKING CATEGORY 1 FLAWS MAJOR AREA ON RPV REGION INSIDE SURFACE (SQUARE FEET) 1 0.587 2 0.587 3 0.946 4 0.946 5 4.282 6 105.038 7 105.038 8 169.372 9 169.372 REPORT WELD FUSION LINE AREA WHICH IS USED IN THE DETERMINATION OF THE NUMBER OF EMBEDDED FLAWS IN WELDED REGIONS USER-INPUT CAT 2 FLAW CAT3 FLAW MAJOR WELD FUSION WELD FUSION WELD FUSION REGION LINE AREA LINE AREA LINE AREA (SQUARE FEET) (SQUARE FEET) (SQUARE FEET) 1 3.373 0.843 1.686 2 3.373 0.843 1.686 3 5.439 1.360 2.719 4 5.439 1.360 2.719 5 28.380 7.095 14.190 NOTES:
(1) USER-INPUT FUSION LINE AREA IS FOR ONE SIDE OF WELD (2) CATEGORY 2 FUSION LINE AREA IS IN THE FIRST 1/8th OF RPV WALL - ACCOUNTS FOR BOTH SIDES OF WELD (3) CATEGORY 3 FUSION LINE AREA IS BETWEEN FIRST 1/8 AND 3/8 OF RPV WALL - ACCOUNTS FOR BOTH SIDES OF WELD THIS IS CONSISTENT WITH DEFINITIONS OF CATEGORIES 2 AND 3 EMBEDDED FLAWS FOR IHEAT = 1 REPORT PLATE VOLUME WHICH IS USED IN THE DETERMINATION OF THE NUMBER OF EMBEDDED FLAWS IN PLATE REGIONS MAJOR PLATE REGION VOLUME (CUBIC FEET) 6 72.574 7 72.574 8 117.024 9 117.024 REPORTING FROM SUBROUTINE FLWDIS:
REPORT NUMBER OF FLAWS IN EACH MAJOR REGION
99 FLAWSIZE.OUT FAVPFM INPUT FILE NAME = favpfm.in FAVLOAD OUTPUT FILE NAME = FAVLoad.out SURF-BREAKING FLAW CHARACTERIZATION DATASET FILE NAME = S.DAT EMBEDDED WELD FLAW CHARACTERIZATION DATASET FILE NAME = W.DAT EMBEDDED PLATE FLAW CHARACTERIZATION DATASET FILE NAME = P.DAT FAVPFM OUTPUT FILE NAME = favpfm.out FLAW SIZE-DISTRIBUTION HISTOGRAMS FOR CATEGORIES 1-3 FOR FLAW FILE 1 DERIVED FROM INPUT FLAW CHARACTERIZATION FILES CATEGORY 1 CATEGORY 2 CATEGORY 3 DEPTH WELD PLATE WELD PLATE WELD PLATE 0.0804 0.0000 0.0000 91.9564 75.7314 91.9564 75.7314 0.1607 0.0000 0.0000 7.0583 23.3408 7.0583 23.3408 0.2411 100.0000 100.0000 0.6743 0.8302 0.6743 0.8302 0.3214 0.0000 0.0000 0.1906 0.0976 0.1906 0.0976 0.4018 0.0000 0.0000 0.0557 0.0000 0.0557 0.0000 0.4822 0.0000 0.0000 0.0238 0.0000 0.0238 0.0000 0.5625 0.0000 0.0000 0.0135 0.0000 0.0135 0.0000 0.6429 0.0000 0.0000 0.0087 0.0000 0.0087 0.0000 0.7232 0.0000 0.0000 0.0059 0.0000 0.0059 0.0000 0.8036 0.0000 0.0000 0.0040 0.0000 0.0040 0.0000 0.8840 0.0000 0.0000 0.0028 0.0000 0.0028 0.0000 0.9643 0.0000 0.0000 0.0019 0.0000 0.0019 0.0000 1.0447 0.0000 0.0000 0.0013 0.0000 0.0013 0.0000 1.1250 0.0000 0.0000 0.0009 0.0000 0.0009 0.0000 1.2054 0.0000 0.0000 0.0006 0.0000 0.0006 0.0000 1.2858 0.0000 0.0000 0.0004 0.0000 0.0004 0.0000 1.3661 0.0000 0.0000 0.0003 0.0000 0.0003 0.0000 1.4465 0.0000 0.0000 0.0002 0.0000 0.0002 0.0000 1.5268 0.0000 0.0000 0.0001 0.0000 0.0001 0.0000 1.6072 0.0000 0.0000 0.0001 0.0000 0.0001 0.0000 1.6876 0.0000 0.0000 0.0001 0.0000 0.0001 0.0000 1.7679 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.8483 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.9286 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.0090 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.0894 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.1697 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.2501 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.3304 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.4108 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.4912 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.5715 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.6519 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.7322 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.8126 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.8930 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.9733 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.0537 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.1340 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.2144 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.2948 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.3751 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.4555 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.5358 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.6162 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.6966 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.7769 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.8573 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 3.9376 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.0180 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.0984 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.1787 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.2591 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.3394 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.4198 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.5002 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.5805 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.6609 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.7412 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.8216 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.9020 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 4.9823 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.0627 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 5.1430 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
100 History_001_007.out Plant ID = favpfm @ 60. EFPY Transient No. = 001 TH Sequence No. = 007 PFM model consists of 9 major regions.
Mean Value of Major Region Product Form RTNDT(u) 1 axial weld -56.00 2 axial weld -56.00 3 axial weld -56.00 4 axial weld -56.00 5 circ. weld -56.00 6 plate 27.00 7 plate 20.00 8 plate 73.00 9 plate 43.00
- Data Format *
- 1st column = RPV trial number *
- 2nd column = major region number *
- 3rd column = sampled value of unirradiated RTNDT *
- 4th column = sampled value of DRTepistemic *
- 5th column = number of axial flaws for which CPI > 0 *
- 6th column = CPI for axial cracks in this region *
- 7th column = CPF for axial cracks in this region *
- 8th column = number of circ. flaws for which CPI > 0 *
- 9th column = CPI for circ. cracks in this region *
- 10th column = CPF for circ. cracks in this region *
- (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) 1 1 -43.28 18.74 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 1 2 -41.09 17.46 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 1 3 -104.02 -21.05 2 1.7493E-06 1.7360E-07 0 0.0000E+00 0.0000E+00 1 4 -66.52 19.37 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 1 5 -64.54 22.95 0 0.0000E+00 0.0000E+00 10 2.4743E-04 1.0495E-08 1 6 27.00 65.11 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 1 7 20.00 -10.29 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 1 8 73.00 0.81 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 1 9 43.00 30.85 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 2 1 -59.17 8.56 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 2 2 -42.02 2.08 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 800 1 -67.28 2.93 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 800 2 -44.04 35.34 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 800 3 -58.99 107.84 1 6.8049E-10 2.3934E-10 0 0.0000E+00 0.0000E+00 800 4 -48.34 31.19 5 1.5364E-04 3.8197E-05 0 0.0000E+00 0.0000E+00 800 5 -53.95 16.44 0 0.0000E+00 0.0000E+00 22 4.9255E-03 1.4290E-08 800 6 27.00 44.83 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 800 7 20.00 40.87 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 800 8 73.00 -14.21 2 4.3105E-08 2.9737E-08 4 2.9849E-05 0.0000E+00 800 9 43.00 59.49 0 0.0000E+00 0.0000E+00 0 0.0000E+00 0.0000E+00 Summary Data Format
- 1st column = major region number *
- 2nd column = mean CPI for all axial flaws *
- 3rd column = mean CPF for all axial flaws *
- 4th column = mean CPI for all circ. flaws *
- 5th column = mean CPF for all circ. flaws *
- (1) (2) (3) (4) (5) 1 2.2925E-05 2.7052E-06 0.0000E+00 0.0000E+00 2 1.2930E-05 1.6615E-06 0.0000E+00 0.0000E+00 3 2.4798E-04 4.2143E-05 0.0000E+00 0.0000E+00 4 4.8499E-04 7.5957E-05 1.7613E-05 6.5088E-12 5 0.0000E+00 0.0000E+00 2.0435E-03 9.5477E-07 6 3.0595E-08 1.5210E-08 1.4556E-04 5.8439E-12 7 7.8208E-09 2.7636E-09 1.7461E-05 8.1872E-12 8 3.6250E-05 1.9089E-05 1.6818E-03 1.8073E-06 9 1.2527E-07 6.4594E-08 3.7449E-04 8.2994E-09
101 2.7 FAVOR Post-Processing Module - FAVPost Output FAVPost reads in three files: (1) FAVPOST.IN containing PRA transient-initiating frequency histogram data, (2) INITIATE.DAT (or another filename determined by user) that contains the conditional-probability-of-initiation matrix for all transients and all vessel simulations, and (3)
FAILURE.DAT (or another filename determined by user) that contains the conditional-probability-of-failure matrix for all transients and all vessel simulations. The following pages present a partial listing of an example of the FAVPost output file. Two additional files, called PDFCPI.OUT and PDFCPF.OUT, are automatically generated containing histograms of the discrete distributions for CPI and CPF for each transient.
FAVPOST.OUT contains first a summary of the (1) mean conditional probability of initiation and the 95th and 99th percentiles for all transients and (2) the mean conditional probability of vessel failure and the 95th and 99th percentiles for all transients. The next section in FAVPOST.OUT contains a histogram (probability density distribution function) for the frequency of crack initiation. Both the relative density and cumulative distribution are given in this section along with several descriptive statistics including the 5th percentile, the median, 95th percentile, 99th percentile, 99.9th percentile, the mean, the standard deviation., the standard error, the unbiased and biased variance, two measures of skewness, and the kurtosis. A histogram and descriptive statistics are then presented for the frequency of through-wall cracking (designated as vessel failure). Finally, a fractionalization of the frequencies of crack initiation and vessel failure are given as functions of transient, material, flaw category, flaw orientation, and major beltline regions.
The statistical data in the form of relative densities, cumulative probabilities, and estimated percentiles presented in tabulated histograms and summary tables for the various discrete distributions calculated by FAVOR are estimated both by binning procedures and through the construction of empirical distribution functions as described in the following.
Construction of Empirical Distribution Functions Using Order Statistics in FAVPost Following the discussion in ref. [27], consider the observations
1, n
x x
from an unknown population assumed to have a probability density
f x. These sampled observations can be ordered by rank such that
102
(1) 1 (2) 1
( )
1
( )
1 smallest of x,
second smallest of x,
k-th smallest of x,
largest of x,
n n
k n
n n
x x
x x
x x
x x
where the quantities (1)
(2)
( )
n x
x x
are random variates and are called the order statistics of the sample. The quantity (1) x is the smallest element in the sample,
( )
n x
is the largest,
( )
k x
is the kth-order statistic, and
(
1) m x
is the median of a sample size 2
1 n
m
. Since the probability density,
f x, for the unknown population is assumed a priori to exist, the populations cumulative distribution function, c.d.f,
F x, can, therefore, be defined by
x F x f x dx
(9)
The estimator applied in FAVPost for
F x is the Kaplan-Meier estimate [28]
( )
/
i F x i n
. 2 Following the recommendations in ref. [29], FAVPost uses the data values (sorted by rank) for CPI, CPF, Frequency of Crack Initiation, and Through-Wall Cracking Frequency to construct mixed empirical-exponential distribution functions from which cumulative probabilities with their corresponding percentiles can be estimated. As discussed in [29], one difficulty with using a purely empirical c.d.f. based on the estimator
( )
/
i F x i n
is that it is discrete and when interpolated can possibly provide a poor fit to the true underlying distribution in the right tail. Fitting a shifted exponential distribution to represent the extreme right tail alleviates this problem [29]. The shifted exponential distribution for the right tail also replaces the unrealistic estimate of
( )
/
1 n
F x n n
The following procedure is applied in FAVPost (see Fig. 18).
2 Other estimators are also in common use, including the mean rank
( )
/
1 i
F x i
n
and median rank
( )
0.3 /
0.4 i
F x i
n
estimators.
103 Construction of Mixed Empirical/Exponential Distribution Functions (1) Order the data by rank such that 1
2 n
X X
X
(2) Fit a piecewise linear c.d.f. to the first n k
ordered data points and a shifted exponential to the k largest data points. Assuming
0 0
F
and defining 0
0 X
, the constructed mixed empirical-exponential c.d.f. is
( )
( )
(
1)
(
1)
( )
(
)
(
)
(
)
( )
1 for 0,1, 1
1 exp for where 1
2 i
i i
i i
n k n k n
n k i
i n k t
X i
X t
X i
n k
n n X X
F t t
X k
t X
n k X X
k
(10)
The value of k is selected automatically in FAVPost such that only cumulative probabilities greater than 0.999 are estimated by the fitted shifted-exponential distribution. The mean of this mixed distribution is
(1)
(2)
( ) /
n X
X X
n
for 1 k
n
, thus recovering the original sample mean.
An estimator for the variance is
1 1
2 2
( )
( )
(
1)
(
)
1 1
2 2
2
(
)
( )
1 1
var 2
3 1
n k n k i
i i
n k i
i n
n k i
i X
X X
X X
n k
X X
n n
(11)
Given a specified probability 0 1
iP
, then the corresponding percentile (quantile) is calculated by:
(1) if 1
i k
P n
, then estimate from the fitted exponential right tail
104
1 ln i
i P
n k n
P X
X k
(12)
(2) else if 1
i k
P n
, then estimate from a piecewise linear interpolation within the empirical distribution
1 where satisfies the relation 1
iP i
I I
I i
I X
P X
X X
n I
I nP I
(13)
(a)
(b)
(c)
(d)
Fig. 18. Empirical distribution functions for n = 10,000 example problem: (a) histogram and (b) semi-log plot of empirical c.d.f. for frequency of crack initiation, (c) histogram and (d) semi-log plot empirical c.d.f. for through-wall cracking frequency.
105 (e)
(f)
Fig. 18. (continued ) Semi-log plots of empirical distribution functions with fitted exponential right tail for n = 10,000 example problem: (e) mixed empirical/exponential c.d.f. for frequency of crack initiation and (f) mixed empirical/exponential c.d.f. for through-wall cracking frequency.
106 The following descriptive statistics are calculated and reported in the FAVPost output:
m1 - 1st crude moment of the sample (sample mean) =
1 n
i i
x x
n
unbiased variance
2 2
1 1
n i
i x
x s
n
biased variance =
2 1
n i
i x
x n
standard deviation,
2 1
1 n
i i
x x
s n
standard error =
2 1
1 n
i i
x x
n n
moment coefficient of skewness,
2 3
3 1
2 3
3 1
1 2
n n
i i
i i
x x
x x
m m
m n
n m
Pearsons second coefficient of skewness = 3 x median s
moment coefficient of kurtosis,
2 4
4 2
2 4
2 1
1 2
(
)
n n
i i
i i
x x
x x
m m
m m
n n
107 FAVPOST.OUT
- WELCOME TO FAVOR *
- FRACTURE ANALYSIS OF VESSELS: OAK RIDGE *
- VERSION 16.1 *
- FAVPOST MODULE: POSTPROCESSOR MODULE *
- COMBINES TRANSIENT INITIAITING FREQUENCIES *
- WITH RESULTS OF PFM ANALYSIS *
- PROBLEMS OR QUESTIONS REGARDING FAVOR *
- SHOULD BE DIRECTED TO *
- TERRY DICKSON *
- OAK RIDGE NATIONAL LABORATORY *
- e-mail: dicksontl@ornl.gov *
- This computer program was prepared as an account of *
- work sponsored by the United States Government *
- Neither the United States, nor the United States *
- Department of Energy, nor the United States Nuclear *
- Regulatory Commission, nor any of their employees, *
- nor any of their contractors, subcontractors, or their *
- employees, makes any warranty, expressed or implied, or *
- assumes any legal liability or responsibility for the *
- accuracy, completeness, or usefulness of any *
- information, apparatus, product, or process disclosed, *
- or represents that its use would not infringe *
- privately-owned rights.
- Begin echo of FAVPost input data deck no./col. 1.......10........20........30........40........50........60........70........80 1 ********************************************************************************
2
- ALL RECORDS WITH AN ASTERISK (*) IN COLUMN 1 ARE COMMENT ONLY
- 3 ********************************************************************************
4
- EXAMPLE INPUT DATASET FOR FAVPost, v16.1
- 5 ********************************************************************************
6 *====================
- 7
- Record CNTL
- 8 *====================
- 9 *------------------------------------------------------------------------------*
10
- NTRAN = NUMBER OF T-H TRANSIENTS
- 11 *------------------------------------------------------------------------------*
12 ********************************************************************************
13 CNTL NTRAN=4 14 ********************************************************************************
15 *====================
- 16
- Record ITRN
- 17 *====================
- 18 *------------------------------------------------------------------------------*
19
- ITRAN = PFM TRANSIENT NUMBER
- 20
- ITRAN = TRANSIENT NUMBER
- 21
- NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION
- 22
- ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER
- 23 *------------------------------------------------------------------------------*
24 ********************************************************************************
25 ITRN ITRAN=1 NHIST=20 ISEQ=7 26 ********************************************************************************
27 *------------------------------
28
- freq[events/year] Density [%]
29 *------------------------------
30 2.11E-07 0.50 31 3.01E-07 0.50 32 5.19E-07 1.50 33 7.92E-07 2.50 34 1.32E-06 5.00 35 2.43E-06 10.00 36 3.08E-06 5.00 37 3.79E-06 5.00 38 5.55E-06 10.00
108 FAVPOST.OUT (continued)
Range = 3.3019E-07 Number of Simulations = 30 5th Percentile = 0.0000E+00 Median = 6.4017E-10 95.0th Percentile = 1.6982E-07 99.0th Percentile = 3.0989E-07 99.9th Percentile = 5.1028E-07 Mean = 3.0950E-08 Standard Deviation = 7.3242E-08 Standard Error = 1.3372E-08 Variance (unbiased) = 5.3643E-15 Variance (biased) = 5.1855E-15 Moment Coeff. of Skewness = 2.9456E+00 Pearson's 2nd Coeff. of Skewness = 1.2677E+00 Kurtosis = 1.1328E+01
- PROBABILITY DISTRIBUTION FUNCTION (HISTOGRAM) *
- FOR THROUGH-WALL CRACKING FREQUENCY (FAILURE)
- FREQUENCY OF RELATIVE CUMULATIVE TWC FAILURES DENSITY DISTRIBUTION (PER REACTOR-OPERATING YEAR) (%) (%)
0.0000E+00 73.3333 73.3333 1.1464E-09 16.6667 84.7477 3.4391E-09 6.6667 96.8066 5.7319E-09 3.3333 99.3314
=================================
Summary Descriptive Statistics
=================================
Minimum = 0.0000E+00 Maximum = 6.6424E-09 Range = 6.6424E-09 Number of Simulations = 30 5th Percentile = 0.0000E+00 Median = 0.0000E+00 95.0th Percentile = 2.7817E-09 99.0th Percentile = 5.1416E-09 99.9th Percentile = 8.5178E-09 Mean = 4.8876E-10 Standard Deviation = 1.4473E-09 Standard Error = 2.6425E-10 Variance (unbiased) = 2.0948E-18 Variance (biased) = 2.0250E-18 Moment Coeff. of Skewness = 3.2312E+00 Pearson's 2nd Coeff. of Skewness =-3.1383E-01 Kurtosis = 1.2937E+01
- FRACTIONALIZATION OF FREQUENCY OF CRACK INITIATION *
- AND THROUGH-WALL CRACKING FREQUENCY (FAILURE) - *
- WEIGHTED BY TRANSIENT INITIATING FREQUENCIES *
% of total % of total frequency of frequency of crack initiation of TWC failure 7 3.47 0.33 9 1.05 0.00 56 95.42 99.16 97 0.07 0.50 TOTALS 100.00 100.00 1.045 0.00 0.00 0.00 0.00 0.00 0.00 1.125 0.00 0.00 0.00 0.00 0.00 0.00 1.205 0.00 0.00 0.00 0.00 0.00 0.00 1.286 0.00 0.00 0.00 0.00 0.00 0.00 1.366 0.00 0.00 0.00 0.00 0.00 0.00 1.446 0.00 0.00 0.00 0.00 0.00 0.00 1.527 0.00 0.00 0.00 0.00 0.00 0.00 1.607 0.00 0.00 0.00 0.00 0.00 0.00 1.688 0.00 0.00 0.00 0.00 0.00 0.00 1.768 0.00 0.00 0.00 0.00 0.00 0.00 1.848 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS 0 00 58 45 0 00 0 00 37 77 0 00
109 FAVPOST.OUT (continued)
- FRACTIONALIZATION OF FREQUENCY OF CRACK INITIATION *
- AND THROUGH-WALL CRACKING FREQUENCY (FAILURE) - *
- BY *
- RPV BELTLINE MAJOR REGION *
- BY PARENT SUBREGION *
- WEIGHTED BY % CONTRIBUTION OF EACH TRANSIENT *
- TO FREQUENCY OF CRACK INITIATION AND *
- THROUGH-WALL CRACKING FREQUENCY (FAILURE) *
% of total
% of % of total through-wall crack MAJOR RTndt total frequency of frequency REGION (MAX) flaws crack initiation cleavage ductile total 1 160.02 2.29 0.00 0.00 0.00 0.00 2 160.02 2.29 0.24 0.40 0.08 0.48 3 150.36 3.70 12.41 21.22 12.70 33.93 4 150.36 3.70 0.93 2.95 0.42 3.36 5 67.56 19.29 44.86 0.00 0.00 0.00 6 195.48 13.15 0.00 0.00 0.00 0.00 7 166.28 13.15 0.00 0.00 0.00 0.00 8 226.00 21.21 34.96 57.84 4.30 62.14 9 196.00 21.21 6.60 0.10 0.00 0.10 TOTALS 99.99 100.00 82.50 17.50 100.00
- FRACTIONALIZATION OF FREQUENCY OF CRACK INITIATION *
- AND THROUGH-WALL CRACKING FREQUENCY (FAILURE) - *
- BY *
- RPV BELTLINE MAJOR REGION *
- BY CHILD SUBREGION *
- WEIGHTED BY % CONTRIBUTION OF EACH TRANSIENT *
- TO FREQUENCY OF CRACK INITIATION AND *
- THROUGH-WALL CRACKING FREQUENCY (FAILURE) *
% of total
% of % of total through-wall crack MAJOR RTndt total frequency of frequency REGION (MAX) flaws crack initiation cleavage ductile total 1 160.02 2.29 0.00 0.00 0.00 0.00 2 160.02 2.29 0.00 0.00 0.00 0.00 3 150.36 3.70 0.00 0.00 0.00 0.00 4 150.36 3.70 0.00 0.00 0.00 0.00 5 67.56 19.29 0.00 0.00 0.00 0.00 6 195.48 13.15 0.41 0.40 0.08 0.48 7 166.28 13.15 0.00 0.00 0.00 0.00 8 226.00 21.21 92.26 82.00 17.43 99.43 9 196.00 21.21 7.32 0.10 0.00 0.10 TOTALS 99.99 100.00 82.49 17.51 100.00
- FRACTIONALIZATION OF FREQUENCY OF CRACK INITIATION *
- AND THROUGH-WALL CRACKING FREQUENCY (FAILURE) - *
- MATERIAL, FLAW CATEGORY, AND FLAW DEPTH *
- WEIGHTED BY % CONTRIBUTION OF EACH TRANSIENT *
- TO FREQUENCY OF CRACK INITIATION AND *
- THROUGH-WALL CRACKING FREQUENCY (FAILURE) *
- WELD MATERIAL *
% of total frequency % of total through-wall of crack initiation crack frequency FLAW DEPTH CAT I CAT 2 CAT 3 CAT 1 CAT 2 CAT 3 (in) flaws flaws flaws flaws flaws flaws 0.080 0.00 0.10 0.00 0.00 0.12 0.00 0.161 0.00 57.37 0.00 0.00 37.17 0.00 0.241 0.00 0.25 0.00 0.00 0.48 0.00 0.321 0.00 0.18 0.00 0.00 0.00 0.00 0.402 0.00 0.55 0.00 0.00 0.00 0.00 0.482 0.00 0.00 0.00 0.00 0.00 0.00 0.563 0.00 0.00 0.00 0.00 0.00 0.00 0.643 0.00 0.00 0.00 0.00 0.00 0.00 0.723 0.00 0.00 0.00 0.00 0.00 0.00
110 FAVPOST.OUT (continued) 0.804 0.00 0.00 0.00 0.00 0.00 0.00 0.884 0.00 0.00 0.00 0.00 0.00 0.00 0.964 0.00 0.00 0.00 0.00 0.00 0.00 1.045 0.00 0.00 0.00 0.00 0.00 0.00 1.125 0.00 0.00 0.00 0.00 0.00 0.00 1.205 0.00 0.00 0.00 0.00 0.00 0.00 1.286 0.00 0.00 0.00 0.00 0.00 0.00 1.366 0.00 0.00 0.00 0.00 0.00 0.00 1.446 0.00 0.00 0.00 0.00 0.00 0.00 1.527 0.00 0.00 0.00 0.00 0.00 0.00 1.607 0.00 0.00 0.00 0.00 0.00 0.00 1.688 0.00 0.00 0.00 0.00 0.00 0.00 1.768 0.00 0.00 0.00 0.00 0.00 0.00 1.848 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS 0.00 44.86 0.00 0.00 0.00 0.00
- CIRC. PLATE *
% of total frequency % of total through-wall of crack initiation crack frequency FLAW DEPTH CAT I CAT 2 CAT 3 CAT 1 CAT 2 CAT 3 (in) flaws flaws flaws flaws flaws flaws 0.080 0.00 0.00 0.00 0.00 0.00 0.00 0.161 0.00 0.00 0.00 0.00 0.00 0.00 0.241 37.08 0.00 0.00 0.49 0.00 0.00 0.321 0.00 0.57 0.00 0.00 0.00 0.00 0.402 0.00 0.00 0.00 0.00 0.00 0.00 0.482 0.00 0.00 0.00 0.00 0.00 0.00 0.563 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS 37.08 0.57 0.00 0.49 0.00 0.00 DATE: 19-Nov-2012 TIME: 11:15:43 1.286 0.00 0.34 0.00 0.00 0.14 0.00 1.366 0.00 0.14 0.00 0.00 0.24 0.00 1.446 0.00 0.01 0.00 0.00 0.08 0.00 1.527 0.00 0.00 0.00 0.00 0.10 0.00 1.607 0.00 0.06 0.00 0.00 0.56 0.00 1.688 0.00 0.02 0.00 0.00 0.02 0.00 1.768 0.00 0.00 0.00 0.00 0.00 0.00 1.848 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS 3.31 50.96 0.00 1.03 68.84 0.05
- PLATE MATERIAL *
% of total frequency % of total through-wall of crack initiation crack frequency FLAW DEPTH CAT I CAT 2 CAT 3 CAT 1 CAT 2 CAT 3 (in) flaws flaws flaws flaws flaws flaws 0.080 0.00 0.00 0.00 0.00 0.01 0.00 0.161 0.00 0.12 0.00 0.00 0.90 0.00 0.241 45.17 0.26 0.00 24.87 2.86 0.00 0.321 0.00 0.18 0.00 0.00 1.45 0.00 TOTALS 45.17 0.56 0.00 24.87 5.21 0.00
111
- 3. Example Case Example input and output datasets have been included in the distribution package to illustrate the various deterministic and probabilistic capabilities that are available with FAVOR.
Deterministic - generation of time history of fracture-related variables at specified through-wall location Table 4 provides a listing of FAVLoad input/output datasets for various RPV geometries subjected to cool-down and heat-up transients that are included in the distribution package.
Table 5 provides a listing of FAVPFM deterministic input/output datasets that are included in the distribution package for illustrating how to generate time histories of fracture-related variables for various surface breaking flaw geometries, orientations, and vessel geometries.
Table 6 provides a listing of FAVPFM deterministic input/output datasets that are included in the distribution package for illustrating how to generate time histories of fracture-related variables for various embedded flaw geometries, thru-wall locations, orientations, and vessel geometries.
Deterministic - generation of through-wall spatial profile of fracture-related variables at specified transient time Table 7 provides a listing of FAVPFM deterministic input/output datasets that are included in the distribution package that illustrate how to generate through-wall spatial profiles of fracture-related variables for various surface-breaking flaw geometries, orientations, and vessel geometries.
Example FAVPFM files for Performing Probabilistic Fracture Mechanics (PFM) Analyses Example PFM_flaw_population_1 This example performs a PFM analysis for a large embrittlement map (developed for the RPV beltline description shown in Figure 19) subjected to four cool-down transients. Since the flaw population model (IPFLAW = 1 on CNT1 record) is set to one, all surface breaking flaws postulated in the surface flaw characterization file (s.dat) are placed on the inner surface of the RPV and only those embedded flaws that are postulated in the weld (w.dat) and plate (p.dat) embedded flaw files to
112 reside in the 3/8 of the base metal nearest the inner (wetted) surface are included in the analysis. This is identical to the previous versions of FAVOR and is designed primarily for cool-down transients since these are the typically the flaws of interest in a cool-down transient.
Example PFM_flaw_population_2 This example performs a PFM analysis for a smaller embrittlement map subjected to multiple heat-up transients. These transients are not to be taken as actual postulated transients but are constructed for purely illustrative purposes such that several flaws are initiated thus illustrating (and verifying) the PFM output reports.
Since the flaw population model (IPFLAW = 2 on CNT1 record) is set to two, all surface breaking flaws postulated in the surface flaw characterization file (s.dat) are placed on the external surface of the RPV and only those embedded flaws that are postulated in the weld (w.dat) and plate (p.dat) embedded flaw files to reside in the 3/8 of the base metal nearest the outer surface are included in the analysis.
Example PFM_flaw_population_3 This example performs a PFM analysis for a smaller embrittlement map subjected to both cool-down and heat-up transients. The surface breaking flaw file used in this example problem (s23.dat - surface breaking flaws are 23% of wall thickness in depth) is for illustrative purposes only in so far as these flaw geometries result in predicted fractures for both internal and external surface breaking flaws thus illustrating (and verifying) the PFM output reports.
Since the flaw population model (IPFLAW = 3 on CNT1 record) is set to three, the number of postulated surface breaking flaws (in surface flaw characterization file) would be double that of options 1 and 2; evenly divided between internal and external surface breaking flaws. All of the embedded flaws uniformly distributed through the RPV wall thickness would be included in the model; therefore, application of this option results in 8/3 as many embedded flaws as options 1 and 2 as discussed above. Clearly this model is more general, but also takes considerably more computational time to achieve a converged solution.
Partial input listings for the three FAVOR modules are given on the following pages.
113 Table 4. Example FAVLoad Load Input and Output Datasets Transient Type RPV Geometry FAVLoad input file name FAVLoad output file name Cool-down Ri /t ~ 10 RT10cool.in RT10cool.out Cool-down Ri /t ~ 15 RT15cool.in RT15cool.out Cool-down Ri /t ~ 20 RT20cool.in RT20cool.out Heat-up Ri /t ~ 10 RT10heat.in RT10heat.out Heat-up Ri /t ~ 15 RT15heat.in RT15heat.out Heat-up Ri /t ~ 20 RT20heat.in RT20heat.out Table 5. Example FAVPFM Input and Output Files for Deterministic Time Histories for Various Surface Breaking Flaws Geometries, Orientations, and Vessel Geometries Transient Type Vessel geometry (Ri /t)
Flaw Type Flaw Orient FAVPFM Input File name FAVLoad output File name FAVPFM output File name Cool-down 10 ISB Axial THinSBax.in RT10cool.out THinSBax10.out Cool-down 15 ISB Axial THinSBax.in RT15cool.out THinSBax15.out Cool-down 20 ISB Axial THinSBax.in RT20cool.out THinSBax20.out Cool-down 10 ISB Circ THinSBcr.in RT10cool.out THinSBcr10.out Cool-down 15 ISB Circ THinSBcr.in RT15cool.out THinSBcr15.out Cool-down 20 ISB Circ THinSBcr.in RT20cool.out THinSBcr20.out Heat-up 10 ESB Axial THexSBax.in RT10heat.out THexSBax10.out Heat-up 15 ESB Axial THexSBax.in RT15heat.out THexSBax15.out Heat-up 20 ESB Axial THexSBax.in RT20heat.out THexSBax20.out Heat-up 10 ESB Circ THexSBcr.in RT10heat.out THexSBcr10.out Heat-up 15 ESB Circ THexSBcr.in RT15heat.out THexSBcr15.out Heat-up 20 ESB Circ THexSBcr.in RT20heat.out THexSBcr20.out Note: ISB is internal surface breaking; ESB is external surface breaking.
114 Table 6. Example FAVPFM Input and Output Files for Deterministic Time Histories for Various Embedded Flaws Geometries, Orientations Transient Type Flaw Type Flaw Orientation FAVPFM Input File FAVLoad output File FAVPFM output file Cool-down Embedded(1)
Axial THinEMax.in RT10cool.out THinEMax.out Cool-down Embedded(1)
Circ THinEMcr.in RT10cool.out THinEMcr.out Heat-up Embedded(2)
Axial THexEMax.in RT10heat.out THexEMax.out Heat-up Embedded(2)
Circ THexEMcr.in RT10heat.out THexEMcr.out (1) Embedded flaw resides in the inner half of RPV wall thickness (2) Embedded flaw resides in the outer half of RPV wall thickness Table 7. Example FAVPFM Input and Output Files for Deterministic Through-Wall Spatial Profiles of Fracture-Related Variables for Various Surface Breaking Flaws Geometries, Orientations, and Vessel Geometries Transient Type Vessel geometry (Ri /t)
Flaw Type Flaw Orient FAVPFM Input File name FAVLoad output File name FAVPFM output File name Cool-down 10 ISB Axial TWinSBax.in RT10cool.out TWinSBax10.out Cool-down 15 ISB Axial TWinSBax.in RT15cool.out TWinSBax15.out Cool-down 20 ISB Axial TWinSBax.in RT20cool.out TWinSBax20.out Cool-down 10 ISB Circ TWinSBcr.in RT10cool.out TWinSBcr10.out Cool-down 15 ISB Circ TWinSBcr.in RT15cool.out TWinSBcr15.out Cool-down 20 ISB Circ TWinSBcr.in RT20cool.out TWinSBcr20.out Heat-up 10 ESB Axial TWexSBax.in RT10heat.out TWexSBax10.out Heat-up 15 ESB Axial TWexSBax.in RT15heat.out TWexSBax15.out Heat-up 20 ESB Axial TWexSBax.in RT20heat.out TWexSBax20.out Heat-up 10 ESB Circ TWexSBcr.in RT10heat.out TWexSBcr10.out Heat-up 15 ESB Circ TWexSBcr.in RT15heat.out TWexSBcr15.out Heat-up 20 ESB Circ TWexSBcr.in RT20heat.out TWexSBcr20.out Note: ISB is internal surface breaking; ESB is external surface breaking.
115 Example Case FAVLoad input file (partial listing)
- ALL RECORDS WITH AN ASTERISK (*) IN COLUMN 1 ARE COMMENT ONLY *
- EXAMPLE INPUT DATASET FOR FAVLoad, v16.1 *
- ==================== *
- Record GEOM *
- ==================== *
- IRAD = INTERNAL RADIUS OF PRESSURE VESSEL [IN] *
- W = THICKNESS OF PRESSURE VESSEL WALL (INCLUDING CLADDING) [IN] *
- CLTH = CLADDING THICKNESS [IN]
- GEOM IRAD=78.5 W=8.036 CLTH=0.156
- =========================== *
- Records BASE and CLAD *
- =========================== *
- THERMO-ELASTIC MATERIAL PROPERTIES FOR BASE AND CLADDING *
- K = THERMAL CONDUCTIVITY [BTU/HR-FT-F] *
- C = SPECIFIC HEAT [BTU/LBM-F] *
- RHO = DENSITY [LBM/FT**3] *
- E = YOUNG'S ELASTIC MODULUS [KSI] *
- ALPHA = THERMAL EXPANSION COEFFICIENT [F**-1] *
- NU = POISSON'S RATIO [-] *
- NTE = TEMPERATURE DEPENDANCY FLAG *
- NTE = 0==> PROPERTIES ARE TEMPERATURE INDEPENDENT (CONSTANT) *
- NTE = 1==> PROPERTIES ARE TEMPERATURE DEPENDENT *
- IF NTE EQUAL TO 1, THEN ADDITIONAL DATA RECORDS ARE REQUIRED
- BASE K=24.0 C=0.120 RHO=489.00 E=28000 ALPHA=.00000777 NU=0.3 NTE=1
- THERMAL CONDUCTIVITY TABLE NBK NK=16 70 24.8 100 25.0 150 25.1 200 25.2 250 25.2 300 25.1 350 25.0 400 25.1 450 24.6 500 24.3 550 24.0 600 23.7 650 23.4 700 23.0 750 22.6 800 22.2
- SPECIFIC HEAT TABLE NBC NC=16 70 0.1052 100 0.1072 150 0.1101 200 0.1135 250 0.1166 300 0.1194 350 0.1223 400 0.1267 450 0 1277
116 Example Case FAVLoad input file (partial listing) (continued)
- COEFF. OF THERMAL EXPANSION
- ASME Sect. II, Table TE-1
- Material Group - 18Cr-8Ni pp. 582-583 NALF N=15 Tref0=70 100 0.00000855 150 0.00000867 200 0.00000879 250 0.00000890 300 0.00000900 350 0.00000910 400 0.00000919 450 0.00000928 500 0.00000937 550 0.00000945 600 0.00000953 650 0.00000961 700 0.00000969 750 0.00000976 800 0.00000982
- POISSON'S RATIO NNU N=2
- 0. 0.3 1000. 0.3
- ==================== *
- Record SFRE *
- ==================== *
- T = BASE AND CLADDING STRESS-FREE TEMPERATURE [F] *
- CFP = crack-face pressure loading flag *
- CFP = 0==> no crack-face pressure loading *
- CFP = 1==> crack-face pressure loading applied
- SFRE T=488 CFP=1
- ========================= *
- Records RESA AND RESC *
- ========================= *
- SET FLAGS FOR RESIDUAL STRESSES IN WELDS *
- NRAX = 0 AXIAL WELD RESIDUAL STRESSES OFF *
- NRAX = 101 AXIAL WELD RESIDUAL STRESSES ON *
- NRCR = 0 CIRCUMFERENTIAL WELD RESIDUAL STRESSES OFF *
- NRCR = 101 CIRCUMFERENTIAL WELD RESIDUAL STRESSES ON
- RESA NRAX=101 RESC NRCR=101
- ========================= *
- Record TIME *
- ========================= *
- TOTAL = TIME PERIOD FOR WHICH TRANSIENT ANALYSIS IS TO BE PERFORMED [MIN]*
- DT = TIME INCREMENT [MIN]*
TIME TOTAL=80.0 DT=0.5
- =============== *
- Record NPRA *
- =============== *
- NTRAN = NUMBER OF TRANSIENTS TO BE INPUT [-]
- NPRA NTRAN=4
- ========================= *
- Record TRAN *
- ========================= *
- ITRAN = PFM TRANSIENT NUMBER *
- ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER
- TRAN ITRAN=1 ISEQ=7
- ========================= *
- Record NHTH *
- ========================= *
- CONVECTIVE HEAT TRANSFER COEFFICIENT TIME HISTORY *
- NC = NUMBER OF (TIME,h) RECORD PAIRS FOLLOWING THIS LINE
- NHTH NC=500
117 Example Case FAVPFM input file (partial listing)
- ALL RECORDS WITH AN ASTERISK(*) IN COLUMN 1 ARE COMMENT ONLY *
- EXAMPLE INPUT DATASET FOR FAVPFM, v16.1 - LARGLE EMBRITTLEMENT MAP subjected to multiple cooldown *
- ==================== *
- Control Record CNT1 *
- ==================== *
- NSIM = NUMBER OF RPV SIMULATIONS *
- IPFLAW = FLAW POPULATION MODEL *
- IPFLAW = 1 Identical to previous version of FAVOR - primarily for cooldown transients. *
- All Surface flaws (in surface flaw characterizatiuon file) will be inner surface *
- breaking flaws. Only those embedded flaws (in weld and plate flaw characterization *
- files) in the inner 3/8 of the RPV wall thickness would be included in the model. *
- IPFLAW = 2 Similar to previous version of FAVOR-HT - primarily for heat-up transients. *
- All surface breaking flaws (in surface flaw characterization file) would be *
- external surface breaking flaws. Only those embedded flaws in the outer 3/8 of the *
- RPV wall thickness would be included in the model. *
- IPFLAW = 3 The number of postulated surface breaking flaws (in surface flaw characterization *
- file) would be double that of options 1 and 2; evenly divided between internal *
- and external surface breaking flaws. All of the embedded flaws uniformly *
- distributed through the RPV wall thickness would be included in the model. *
- See Theory Manual for further discussion. *
- IGATR = NUMBER OF INITIATION-GROWTH-ARREST (IGA) TRIALS PER FLAW *
- WPS_OPTION = 0 DO NOT INCLUDE WARM-PRESTRESSING IN ANALYSIS *
- WPS_OPTION = 1 INCLUDE TRADITIONAL FAVOR BASELINE WARM-PRESTRESSING Model IN ANALYSIS *
- WPS_OPTION = 2 INCLUDE Conservative Principal WARM-PRESTRESSING MODEL IN ANALYSIS *
- WPS_OPTION = 3 INCLUDE Best-Estimate WARM-PRESTRESSING MODEL IN ANALYSIS *
- See Theory Manual for details regarding WARM_PRESTRESS Models *
- Note: Previous Versions of FAVOR prior to the 09.1 included only options 0 and 1. *
- CHILD_OPTION = 0 DO NOT INCLUDE CHILD SUBREGION REPORTS [-] *
- CHILD_OPTION = 1 INCLUDE CHILD SUBREGION REPORTS [-] *
- RESTART_OPTION = 0 THIS IS NOT A RESTART CASE [-] *
- RESTART_OPTION = 1 THIS IS A RESTART CASE [-] *
- ============================= *
- Notes for Control Record CNT1 *
- ============================= *
- IN A TYPICAL PFM ANALYSIS, A SUBSTANTIAL FRACTION OF THE TOTAL FLAWS ARE CATEGORY 3 FLAWS IN *
- PLATE REGIONS. BASED ON EXPERIENCE AND SOME DETERMINISTIC FRACTURE ANALYSES, THESE FLAWS VERY *
- THEREFORE, INVOKING IP3OPT = 0 CAN RESULT IN A SIGNIFICANT REDUCTION IN EXECUTION TIME WITHOUT *
- AFFECTING THE SOLUTION, UNLESS THERE ARE UNUSUAL CIRCUMSTANCES SUCH AS A NEW FLAW-SIZE *
- DISTRIBUTION FOR PLATE FLAWS. IN EITHER CASE, CATEGORY 3 PLATE FLAWS ARE INCLUDED IN ALL REPORTS. *
- IF IPFLAW = 3; THEN PC3_OPTION AUTOMATICALLY OVER-RIDES AND SETS PC3_OPTION = 1 *
- Notes on Restart Option: *
- The restart option flag can also be used to control the frequency with which restart files are *
- created. If RESTART_OPTION is given a value other than 0 or 1, then the absolute value of this flag *
- sets the checkpoint interval at which the restart file will be created during the run. For example, *
- 1.RESTART_OPTION = -200==> This is not a restart case; restart files will be created every 200 trials *
- 2.RESTART_OPTION = 0==> Same as example No. 1. *
- 3.RESTART_OPTION = 200==> This is a restart case; restart files will be created every 200 trials.*
- 4.RESTART_OPTION = 1==> Same as example No. 3. *
- 5.RESTART_OPTION = -50==? This is not a restart case; restart files will be created every 50 trials.
- CNT1 NSIM=100 IPFLAW=1 IGATR=100 WPS_OPTION=1 PC3_OPTION=0 CHILD_OPTION=1 RESTART_OPTION=0
- ==================== *
- Control Record CNT2 *
- ==================== *
- EMBRITTLEMENT CORRELATION FOR ESTIMATING RADIATION-INDUCED SHIFT IN RTNDT *
- IRTNDT = 992==> USE RG 1.99, REV *
- IRTNDT = 2000==> USE E2000 *
- IRTNDT = 2006==> USE modified E2006 *
- IRTNDT = 20071==> USE EricksonKirk 2007 *
- IRTNDT = 20072==> USE RADAMO *
- IRTNDT = 20073==> USE cOMBINED EricksonKirk 2007 + RADAMO *
- EFPY = EFFECTIVE FULL-POWER YEARS OF OPERATION [YEARS] *
- IDT_OPTION = 0 DO NOT INCLUDE DUCTILE TEARING AS A POTENTIAL FRACTURE MODE [-] *
- IDT_OPTION = 1 INCLUDE DUCTILE TEARING AS A POTENTIAL FRACTURE MODE [-] *
- IDT_INI = 0 DO NOT CREATE A LOG OF POTENTIAL DUCTILE TEARING INITIATIONS [-] *
- IDT_INI = 1 CREATE A LOG OF POTENTIAL DUCTILE TEARING INITIATIONS [-]
- O G O 0 O O C j
i il
[ ]
- 118 Example Case FAVPFM input file (continued)
- ==================== *
- Control Record CNT3 *
- ==================== *
- FLWSTR = UNIRRADIATED FLOW STRESS USED IN PREDICTING FAILURE BY REMAINING LIGAMENT INSTABILITY [ksi] *
- USKIA = MAXIMUM VALUE ALLOWED FOR KIc or KIa [ksi-in^1/2] *
- KIa_Model = 1 Use high-constraint KIa model based on CCA specimens [-] *
- KIa_Model = 2 Use KIa model based on CCA + large specimen data [-] *
- LAYER_OPTION = 0 DONOT RESAMPLE PF WHEN ADVANCING INTO NEW WELD LAYER [-] *
- LAYER_OPTION = 1 RESAMPLE PF WHEN ADVANCING INTO NEW WELD LAYER [-] *
- FAILCR = FRACTION OF WALL THICKNESS FOR VESSEL FAILURE BY THROUGH-WALL CRACK PROPAGATION [-] *
- ============================= *
- Notes for Control Record CNT3 *
- ============================= *
- If ductile tearing model is included, then the values for USKIA and KIa_Model are ignored. *
- They are automatically set internally to KIa_Model=2 and there is no upper limit on USKIa. *
- If ductile tearing is not included in the analysis (IDT_OPTION = 0 on CNT1), both the KIa_Model *
- and USKIA are user-specified on CNT3.
- CNT3 FLWSTR=80. USKIA=800. KIa_Model=2 LAYER_OPTION=0 FAILCR=0.9
- ==================== *
- Record GENR *
- ==================== *
- SIGFGL = A MULTIPLIER ON THE BEST ESTIMATE OF FLUENCE FOR A GIVEN SUBREGION [-] *
- PRODUCES THE STANDARD DEVIATION FOR THE NORMAL DISTRIBUTION USED TO SAMPLE THE MEAN *
- OF THE LOCAL FLUENCE DISTRIBUTION. *
- SIGFLC = A MULTIPLIER ON THE SAMPLED MEAN OF THE LOCAL FLUENCE FOR A GIVEN SUBREGION [-] *
- PRODUCES THE STANDARD DEVIATION FOR THE NORMAL DISTRIBUTION USED TO SAMPLE THE LOCAL FLUENCE*
- ====================== *
- Notes for Record GENR *
- ====================== *
- Let "flue" be the best estimate for the subregion neutron fluence at inside surface of the RPV wall. *
- flue_STDEV_global = SIGFGL*flue *
- flue_MEAN_local << Normal(flue,flue_STDEV_global) *
- flue_STDEV_local = SIGFLC*flue_MEAN_local *
- flue_local << Normal(flue_MEAN_local,flue_STDEV_local)
- GENR SIGFGL=0.118 SIGFLC=0.056
- ==================== *
- Record SIGW *
- ==================== *
- STANDARD DEVIATIONS (STDEV) OF NORMAL DISTRIBUTIONS FOR WELD CHEMISTRY SAMPLING: *
- WSIGP = STANDARD DEVIATION FOR PHOSPHOROUS CHEMISTRY SAMPLING IN WELDS [wt%] *
- ====================== *
- Notes for Record SIGW *
- ====================== *
- (1) FOR HEATS 34B009 AND W5214 (Ni - addition welds) *
- WSIGNI = 0.162 wt% using a normal distribution. *
- (2) For other heats, the standard deviation (WSIGNI) shall be sampled from a normal distribution *
- with mean equal to 0.029 wt% and standard deviation = 0.0165 wt%
- SIGW WSIGCU=0.167 WSIGNI=0.162 WSIGP=0.0013
- ==================== *
- Record SIGP *
- ==================== *
- STANDARD DEVIATIONS (STDEV) OF NORMAL DISTRIBUTIONS FOR PLATE CHEMISTRY SAMPLING: *
- PSIGCU = STANDARD DEVIATION FOR COPPER CHEMISTRY SAMPLING IN PLATES [wt%] *
- PSIGNI = STANDARD DEVIATION FOR NICKEL CHEMISTRY SAMPLING IN PLATES [wt%] *
- PSIGP = STANDARD DEVIATION FOR PHOSPHOROUS CHEMISTRY SAMPLING IN PLATES [wt%] *
- ====================== *
- Notes for Record SIGP *
- ====================== *
- RECOMMENDED VALUES ARE: 0.0073, 0.0244, 0.0013 for Cu, Ni, and P, respectively.
- SIGP PSIGCU=0.0073 PSIGNI=0.0244 PSIGP=0.0013
- =============================== *
- Notes for RecordS SIGW and SIGP *
- =============================== *
- THE ABOVE DISTRIBUTIONS ARE FOR THE 1ST FLAW POSITIONED IN A PARTICULAR SUBREGION. *
- IF THE CURRENT FLAW IS THE 2ND OR MORE FLAW FOR THIS SUBREGION, THEN FAVPFM WILL USE *
- THE LOCAL VARIABILITY SAMPLING PROTOCOLS PRESENTED IN THE THEORY MANUAL. *
- ==================== *
- Record TRAC *
- ==================== *
- ITRAN = TRANSIENT NUMBER [-] *
- KFLAW = FLAW NUMBER [-] *
- FLAW_LOG_OPTION = 0 DO NOT CREATE FLAW LOG TABLES [-] *
- FLAW_LOG_OPTION = 1 DO CREATE FLAW LOG TABLES [-] *
- =============================== *
- Notes for Record TRAC *
- ===============================
- 119 Example Case FAVPFM input file (partial listing) (continued)
- ==================== *
- Record TRAC *
- ==================== *
- ITRAN = TRANSIENT NUMBER [-] *
- KFLAW = FLAW NUMBER [-] *
- FLAW_LOG_OPTION = 0 DO NOT CREATE FLAW LOG TABLES [-] *
- FLAW_LOG_OPTION = 1 DO CREATE FLAW LOG TABLES [-] *
- =============================== *
- Notes for Record TRAC *
- =============================== *
- HISTORY WILL BE GIVEN IN THE FILES: "TRACE.OUT" AND "ARREST.OUT" *
- SEE THE USER'S GUIDE FOR DETAILS ON THE CONTENTS OF THESE FILES
- TRAC ITRAN=1 IRPV=1 KFLAW=1 FLAW_LOG_OPTION=0
- ==================== *
- Record LDQA *
- ==================== *
- THE LDQA RECORD PROVIDES THE OPPORTUNITY TO CHECK LOAD-RELATED SOLUTIONS *
- SUCH AS TEMPERATURE, STRESSES, AND KI. *
- IQA = 0==> THIS EXECUTION IS NOT FOR LOAD QA [-] *
- IQA = 1==> THIS EXECUTION IS FOR LOAD QA [-] *
- IOPT = 1==> GENERATE TIME HISTORY AT SPECIFIC THROUGH WALL LOCATION [-] *
- IOPT = 2==> GENERATE THROUGH WALL DISTRIBUTION AT SPECIFIC TIME [-] *
- IFLOR = 1==> FLAW ORIENTATION IS AXIAL [-] *
- IFLOR = 2==> FLAW ORIENTATION IS CIRCUMFERENTIAL [-] *
- IWELD = 0==> DOES NOT INCLUDE THRU-WALL WELD RESIDUAL STRESS [-] *
- IWELD = 1==> DOES INCLUDE THRU-WALL WELD RESIDUAL STRESS [-] *
- IKIND = 1==> INNER-SURFACE BREAKING FLAW [-] *
- IKIND = 2==> EMBEDDED FLAW [-] *
- IKIND = 3==> OUTER-SURFACE BREAKING FLAW [-] *
- XIN IS ONLY USED IF IKIND=2 (EMBEDDED FLAWS) *
- XIN = IF IOPT=1; LOCATION OF INNER CRACK TIP FROM INNER SURF. [IN] *
- XIN = IF IOPT=2; FLAW DEPTH [IN] *
- XVAR: IF IOPT=1; XVAR=FLAW DEPTH [IN] *
- IF IOPT=2; XVAR=TIME [MIN] *
- ASPECT = ASPECT RATIO; FOR SURFACE BREAKING FLAWS: 2,6,10,999 (infin) [-] *
- FOR EMBEDDED FLAWS: ANY VALUE > 0 *
- =============================== *
- Notes for Record LDQA *
- =============================== *
- IQA = 0 NO VALIDATION REPORTS WILL BE GENERATED, PFM ANALYSIS WILL BE PERFORMED *
- IQA = 1 LOAD PARAMETERS WILL BE GENERATED FOR VERIFICATION PURPOSES, PFM ANALYSIS WILL NOT BE PERFORMED*
LDQA IQA=0 IOPT=2 IFLOR=1 IWELD=1 IKIND=1 XIN=2.0 XVAR=50 ASPECT=999
- ==================== *
- Record DTRF *
- ==================== *
- NT = number of ISQ records that follow [-] *
- NT = 0 no ISQ records follow *
- FOLLOWING THE DTRF RECORD, THERE SHOULD BE "NT" SUBRECORDS *
- ISQ ITRAN= ISEQ= TSTART= TEND= *
- ITRAN = sequential number in FAVLoad transient stack [-] *
- ISEQ = Thermal Hydraulic trasient sequence number [-] *
- TSTART = starting time for FAVPFM analysis [MIN] *
- TEND = ending time for FAVPFM analysis [MIN] *
- DTRF NT=0 DTRF NT=4 ISQ ITRAN=1 ISEQ=7 TSTART=2 TEND=35 ISQ ITRAN=2 ISEQ=9 TSTART=1 TEND=29 ISQ ITRAN=3 ISEQ=56 TSTART=12 TEND=54 ISQ ITRAN=4 ISEQ=97 TSTART=30 TEND=82
- ==================== *
- Record WELD *
- ==================== *
- NWSUB = NUMBER OF WELD SUBREGIONS [-] *
- NWMAJ = NUMBER OF WELD MAJOR REGIONS [-]
- WELD NWSUB=838 NWMAJ=5
- ==================== *
- Record PLAT *
- ==================== *
- NPSUB = NUMBER OF PLATE SUBREGIONS [-] *
- NPMAJ = NUMBER OF PLATE MAJOR REGIONS [-]
- PLAT NPSUB=14442 NPMAJ=4
120 Example Case FAVPFM input file (partial listing) (continued)
- PLATE/WELD EMBRITTLEMENT / FLAW DISTRIBUTION MAP RECORDS *
- ==========================================================================================================*
- Field DESCRIPTION [UNITS] *
- ==========================================================================================================*
- (1) RPV subregion number - parent [-] *
- (2) adjacent RPV subregion - 1st child [-] *
- (3) adjacent RPV subregion - 2nd child [-] *
- (4) RPV major region number [-] *
- (5) best estimate neutron fluence at RPV inside surface [10^19 neutrons/cm^2] *
- (6) best estimate copper (Cu) content [wt% Cu] *
- (7) best estimate nickel (Ni) content [wt% Ni] *
- (8) best estimate phosphorus (P) content [wt% P] *
- (9) best estimate manganese (Mn) content [wt% Mn] *
- (10) product form flags for DT30 shift correlation *
- Welds : set distribution for sampling standard *
- deviation for Ni content in welds *
- = 1 use normal distribution [-] *
- = 2 use Weibull distribution [-] *
- Plates: *
- CE = 1 (if IRTNDT=2000 then set B = 206) [-] *
- Not CE = 2 (if IRTNDT=2000 then set B = 156) [-] *
- where CE is a Combustion Engineering vessel *
- (11) copper saturation flag = 0 for plates and forgings [-] *
- = 1 for Linde 80 and Linde 0091 weld fluxes *
- = 2 for all weld fluxes other than L80, L0091, and L1092 *
- = 3 for Linde 1092 weld flux *
- N.B.: *
- for IRTNDT = 2000 *
- = 0.25 for Linde 80 and = 0.305 for all others *
- for IRTNDT = 2006 *
- = 0.37 for Ni < 0.5 wt% *
- = 0.2435 for 0.5 <= Ni <= 0.75 wt% *
- (12) unirradiated best estimate (mean) for RTNDT0 [F] *
- (13) unirradiated standard deviation for RTNDT0 [F] *
- (14) PF flag Product Form CF Override *
- = 11 weld no [-] *
- = 12 weld yes [-] *
- = 21 plate no [-] *
- = 22 plate yes [-] *
- = 31 forging NA [-] *
- (15) angle of subregion element [degrees] *
- (16) axial height of subregion element: [inches] *
- (17) weld fusion area: [inches^2] *
- (18) weld orientation: 1===> axial; 2===> circumferential [-] *
- (19) chemistry factor override [-] *
- (20) unirradiated upper shelf CVN engergy [ft-lbf] *
- ==========================================================================================================*
- Notes: *
- 2. Fields 5-20 : contain RPV beltline embrittlement-related data *
- 3. Field 13 : PF means Product Form *
- 4. Field 13 : CF means chemistry factor override *
- 5. Field 18 : only applies to weld subregions. For plates set to 0. *
- 6. Field 20 : applicable only if IRTNDT=2000 on CNT2 and Field 13 = 12 or 22 *
- ==========================================================================================================*
- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 00001 03593 03661 1 0.0675 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 1.2000 9.4500 1 0 98 00002 03594 03662 1 0.1173 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 1.1996 9.4469 1 0 98 00003 03595 03663 1 0.1682 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 2.3996 18.8969 1 0 98 00004 03596 03664 1 0.2317 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 2.2047 17.3622 1 0 98 00005 03597 03665 1 0.3100 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 2.3996 18.8969 1 0 98 00006 03598 03666 1 0.4193 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 2.3760 18.7109 1 0 98 00007 03599 03667 1 0.5191 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 1.6043 12.6341 1 0 98 00008 03600 03668 1 0.6065 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 1.2500 9.8438 1 0 98 00009 03601 03669 1 0.7145 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 1.5728 12.3861 1 0 98 00010 03602 03670 1 0.8412 0.337 0.609 0.012 1.440 2 3 -56.0 17.0 11 1.0000 1.8720 14.7424 1 0 98 15277 15277 15277 9 1.4176 0.140 0.620 0.015 1.400 1 0 43.0 0.0 21 8.7511 2.3543 0.0000 2 0 90 15278 15278 15278 9 1.1209 0.140 0.620 0.015 1.400 1 0 43.0 0.0 21 8.7511 1.9724 0.0000 2 0 90 15279 15279 15279 9 0.9166 0.140 0.620 0.015 1.400 1 0 43.0 0.0 21 8.7511 1.2500 0.0000 2 0 90 15280 15280 15280 9 0.7084 0.140 0.620 0.015 1.400 1 0 43.0 0.0 21 8.7511 0.9931 0.0000 2 0 90
- END OF EMBRITTLEMENT MAP *****************************************************
121 Example Case FAVPost input file
- ALL RECORDS WITH AN ASTERISK (*) IN COLUMN 1 ARE COMMENT ONLY
- EXAMPLE INPUT DATASET FOR FAVPost, v16.1
========
- Record CNTL *
========
NTRAN = NUMBER OF T-H TRANSIENTS CNTL NTRAN=4
========
- Record ITRN *
========
ITRAN = PFM TRANSIENT NUMBER ITRAN = TRANSIENT NUMBER NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER ITRN ITRAN=1 NHIST=20 ISEQ=7
- freq[events/year] Density [%]
2.11E-07 0.50 3.01E-07 0.50 5.19E-07 1.50 7.92E-07 2.50 1.32E-06 5.00 2.43E-06 10.00 3.08E-06 5.00 3.79E-06 5.00 5.55E-06 10.00 7.90E-06 10.00 1.12E-05 10.00 1.64E-05 10.00 2.03E-05 5.00 2.57E-05 5.00 4.74E-05 10.00 7.82E-05 5.00 1.24E-04 2.50 2.12E-04 1.50 3.09E-04 0.50 1.02E-03 0.50
========
- Record ITRN *
========
ITRAN = TRANSIENT NUMBER NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER ITRN ITRAN=2 NHIST=20 ISEQ=9
- freq[events/year] Density [%]
6.48E-08 0.50 1.01E-07 0.50 1.71E-07 1.50 2.64E-07 2.50 4.40E-07 5.00 8.10E-07 10.00 1.02E-06 5.00 1.26E-06 5.00 1.85E-06 10.00 2.63E-06 10.00 3.76E-06 10.00 5.46E-06 10.00 6.78E-06 5.00 8.54E-06 5.00 1.57E-05 10.00 2.60E-05 5.00 4.12E-05 2.50
122 Example Case FAVPost input file (continued)
========
- Record ITRN *
========
ITRAN = TRANSIENT NUMBER NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER ITRN ITRAN=3 NHIST=20 ISEQ=56
- freq[events/year] Density [%]
1.70E-05 0.50 1.96E-05 0.50 2.68E-05 1.50 3.29E-05 2.50 4.24E-05 5.00 5.58E-05 10.00 6.17E-05 5.00 6.89E-05 5.00 8.35E-05 10.00 9.89E-05 10.00 1.17E-04 10.00 1.41E-04 10.00 1.54E-04 5.00 1.72E-04 5.00 2.33E-04 10.00 2.97E-04 5.00 3.56E-04 2.50 4.55E-04 1.50 6.00E-04 0.50 1.21E-03 0.50
========
- Record ITRN *
========
ITRAN = TRANSIENT NUMBER NHIST = NUMBER OF DATA PAIRS IN DISCRETE FREQUENCY DISTRIBUTION ISEQ = THERMAL-HYDRAULIC SEQUENCE NUMBER ITRN ITRAN=4 NHIST=20 ISEQ=97
- freq[events/year] Density [%]
3.97E-08 0.50 8.40E-08 0.50 1.33E-07 1.50 1.92E-07 2.50 3.10E-07 5.00 5.57E-07 10.00 7.38E-07 5.00 9.21E-07 5.00 1.36E-06 10.00 1.81E-06 10.00 2.49E-06 10.00 3.55E-06 10.00 4.26E-06 5.00 5.30E-06 5.00 8.53E-06 10.00 1.29E-05 5.00 1.96E-05 2.50 2.90E-05 1.50 3.56E-05 0.50 8.62E-05 0.50
123 (a)
(b)
Fig. 19. Example case - (a) rollout of beltline region of vessel showing layout of plates and welds and (b) axial and circumferential distribution of fast-neutron fluence across the beltline.
Figures 20, 21, and 22 present the time histories for the coolant temperature, convection coefficient, and internal pressure, respectively, that are included for all four transients in the input data for FAVOR example PFM_flaw_population1. Figure 23 shows the initiating-event frequency histograms for the four transients that are used as input to FAVPost for this example.
124 Fig. 20. Time histories of coolant temperature for four PTS transients.
Fig. 21.Time histories of convection heat transfer coefficient four PTS transients.
125 Fig. 22. Time histories for internal pressure for four PTS transients.
Fig. 23. Initiation event frequency distribution for PTS Transients 7, 9, 56, and 97.
126
- 4. Summary and Conclusions The FAVOR computer code has been developed under NRC funding to perform probabilistic fracture mechanics analyses of nuclear reactor pressure vessels subjected to pressurized thermal shock and other pressure-thermal events. The following advanced technologies and new capabilities have been incorporated into FAVOR:
the ability to incorporate new detailed flaw-characterization distributions from NRC research (with Pacific Northwest National Laboratory, PNNL),
the ability to incorporate detailed neutron fluence regions - detailed fluence maps from Brookhaven National Laboratory, BNL, the ability to incorporate warm-prestressing effects into the analysis, the ability to include temperature-dependencies in the thermo-elastic properties of base and
- cladding, the ability to include crack-face pressure loading for surface-breaking flaws, new embrittlement correlations, a new ductile-tearing model simulating stable and unstable ductile fracture, the ability to handle multiple transients in one execution of FAVOR, RVID2 database of relevant material properties, fracture-toughness models based on extended databases and improved statistical distributions, a variable failure criterion, i.e., how far must a flaw propagate into the RPV wall for the vessel simulation to be considered as failed ?
semi-elliptic surface-breaking and embedded-flaw models, through-wall weld residual stresses, the addition of base material SIFIC(s) from the proposed ASME code,Section XI, Appendix A, Article A-3000, Method of KI Determination, for infinite and finite axial and 360 continuous and finite circumferential flaws into the FAVOR SIFIC database, and improved PFM methodology that incorporates modern PRA procedures for the classification and propagation of input uncertainties and the characterization of output uncertainties as statistical distributions.
This report has provided a detailed description of the computer system requirements, installation, and execution of the FAVOR, v16.1, deterministic and probabilistic fracture mechanics code. Detailed instructions on input data deck preparation have been presented along with descriptions of all output files. Example input and output cases were included. The companion report Fracture Analysis of Vessels - Oak Ridge, FAVOR, v16.1, Computer Code: Theory and Implementation of Algorithms, Methods, and Correlations [2] gives a detailed review of the computational methodologies implemented into FAVOR.
127
- 5. References
- 1. T. L. Dickson, S. N. M. Malik, J. W. Bryson, and F. A. Simonen, Revisiting the Integrated Pressurized Thermal Shock Studies of an Aging Pressurized Water Reactor, ASME PVP-Volume 388, Fracture, Design Analysis of Pressure Vessels, Heat Exchangers, Piping Components, and Fitness for Service, ASME Pressure Vessels and Piping Conference, August, 1999.
- 2. P. T. Williams, T. L. Dickson, B.R. Bass, and H.B. Klasky, Fracture Analysis of Vessels -
FAVOR (v16.1) Computer Code: Theory and Implementation of Algorithms, Methods, and Correlations, ORNL/TM-2016/309, Oak Ridge National Laboratory, Oak Ridge, TN, 2016.
- 3. D. L. Selby, et al., Pressurized Thermal Shock Evaluation of the Calvert Cliffs Unit 1 Nuclear Power Plant, NUREG/CR-4022 (ORNL/TM-9408), Oak Ridge National Laboratory, Oak Ridge, TN, September 1985.
4. D. L. Selby, et al., Pressurized Thermal Shock Evaluation of the H.B. Robinson Nuclear Power Plant, NUREG/CR-4183 (ORNL/TM-9567), September 1985.
5. T. J. Burns, et al., Preliminary Development of an Integrated Approach to the Evaluation of Pressurized Thermal Shock as Applied to the Oconee Unit 1 Nuclear Power Plant, NUREG/CR-3770 (ORNL/TM-9176), May 1986.
- 6. U.S. Code of Federal Regulations, Title 10, Part 50, Section 50.61 and Appendix G.
- 7. U.S. Nuclear Regulatory Commission, Regulatory Guide 1.154 (1987), Format and Content of Plant-Specific Pressurized Thermal Shock Safety Analysis Reports for Pressurized Water Reactors.
- 8. U. S. Nuclear Regulatory Commission, Regulatory Guide 1.99, Revision 2 (1988), Radiation Embrittlement of Reactor Vessel Materials.
- 9. Proposed Rules 10CFR50.61a (RIN 3150-A101) - Alternate Fracture Toughness Reguirements for Protection Against Pressurized Thermal Shock Events, Federal Register 72(1), October 3, 2007, 56275-56287.
- 10. M. Kirk, et al., Technical Basis for Revision of the Pressurized Thermal Shock (PTS) Screening Limit in the PTS Rule (10 CFR 50.61), NUREG-1806, U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research, Washington, DC, August 2007.
- 11. M. T. Kirk and T. L. Dickson, Recommended Screening Limits for Pressurized Thermal Shock (PTS), NUREG-1874, U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research, Washington, DC, March 2007.
- 12. R. D. Cheverton and D. G. Ball, OCA-P, A Deterministic and Probabilistic Fracture Mechanics Code for Application to Pressure Vessels, NUREG/CR-3618 (ORNL-5991), Oak Ridge National Laboratory, Oak Ridge, TN, May 1984.
128
- 13. F. A. Simonen, et al., VISA-II - A Computer Code for Predicting the Probability of Reactor Pressure Vessel Failure, NUREG/CR-4486 (PNL-5775), Pacific Northwest Laboratory, Richland, Washington, March 1986.
- 14. T. L. Dickson and F. A. Simonen, The Application of Probabilistic Fracture Analysis to Residual Life Evaluation of Embrittled Reactor Vessels, AD-Vol. 28, Reliability Technology, American Society of Mechanical Engineers, (1992) 43-55.
- 15. B. A. Bishop, T. L. Dickson, and F. A. Simonen, Benchmarking of Probabilistic Fracture Mechanics Analyses of Reactor Vessels Subjected to Pressurized Thermal Shock (PTS) Loading, Research Project 2975-5, Final Report, February 1993.
- 16. T. L. Dickson and R. D. Cheverton, Review of Reactor Pressure Vessel Evaluation Report for Yankee Rowe Nuclear Power Station (YAEC No. 1735), Appendix D, NUREG/CR-5799 (ORNL/TM-11982), Oak Ridge National Laboratory, Oak Ridge, TN, March 1992.
- 17. B. R. Bass, et al., International Comparative Assessment Study of Pressurized Thermal Shock in Reactor Pressure Vessels, NUREG/CR-6651 (ORNL/TM-1999/231), Oak Ridge National Laboratory, Oak Ridge, TN, December 1999.
- 18. T. L. Dickson, FAVOR: A Fracture Analysis Code for Nuclear Reactor Pressure Vessels, Release 9401, ORNL/NRC/LTR/94/1, Oak Ridge National Laboratory, Oak Ridge, TN, 1994.
- 19. American Society of Mechanical Engineers Boiler and Pressure Vessel Code - Sect. II, Part D:
Properties, 1998.
- 20. L. Stumpfrock, et al., Brittle Crack Initiation, Propagation and Arrest of Shallow Cracks in a Clad Vessel Under PTS Loading, NESC II Final Report, NESCDOC Man (02) 07, EUR 20696 EN, European Commission DG-JRC/IE, Petten, The Netherlands, March 2003.
- 21. F. N. Fritsch, PCHIP - Piecewise Cubic Hermite Interpolation - SLATEC Package, LLNL, 1992, obtained from netlib.org open-source numerical library.
- 22. F. N. Fritsch and R. E. Carlson, Monotone Piecewise Cubic Interpolation, SIAM J. Numer.
Anal. 17(2), (1980) 238-246.
- 23. F. N. Fritsch and J. Butland, A Method for Constructing Local Monotone Piecewise Cubic Interpolants, SIAM J. Sci. Stat. Comput. 5(2), (1984) 300-304.
- 24. E. D. Eason, J. E. Wright, and G. R. Odette, Improved Embrittlement Correlations for Reactor Pressure Vessel Steels, NUREG/CR-6551, U. S. Nuclear Regulatory Commission, Washington, DC, 1998.
- 25. M. T. Kirk, C. S. Santos, E.D. Eason, J.E. Wright, and G. R. Odette, Updated Embrittlement Trend Curve for Reactor Pressure Vessel Steels, Paper No. G01-5, Transactions of the 17th International Conference on Structural Mechanics in Reactor Technology (SMiRT 17), Prague, Czech Republic, August 17-22, 2003.
- 26. E. D. Eason, G. R. Odette, R. K. Nanstad, and T. Yamamoto, A Physically Based Correlation of Irradiation-Induced Transition Temperature Shifts for RPV Steels, Oak Ridge National Laboratory, ORNL/TM-2006/530, 2006.
129
- 27. I. Guttman, S. S. Wilkes, and J. S. Hunter, Introductory Engineering Statistics, 3rd ed., John Wiley and Sons, In, New York, 1982, pp. 302-331.
- 28. M. Evans, N. Hastings, and B. Peacock, Statistical Distributions, 3rd ed., Wiley Series in Probability and Statistics, John Wiley and Sons, New York, 2000.
- 29. P. Bratley, B. L. Fox, and L. E. Schrage, A Guide to Simulation, 2nd ed., Springer Verlag, New York, 1987, pp. 150-151.
130
- 6. Appendix A - Treatment of Weld Fusion Lines Figure A1 shows a typical rollout section of the beltline region. The user is required to discretize (subdivide) the beltline into several major regions that contain plates (or forgings), axial welds, and circumferential welds. These major regions are further discretized into subregions for greater resolution of the variation in radiation-induced embrittlement. An embrittlement-distribution map is defined in the input data for FAVPFM using these major region and subregion definitions.
In a FAVOR PFM analysis, flaws that are postulated to reside in a weld are assumed to reside on the fusion line between the weld and the adjacent plate or forging. Thus, decisions must be made as to how properties (chemistry and neutron fluence) of the weld or adjacent plate (or forging) should be assigned for the calculation of RTNDT and the fracture toughness KIc.
Controlling Region The discretization of the major regions and sub-regions of the RPV embrittlement model of the beltline includes a special treatment of these weld fusion lines. These fusion lines can be visualized as boundaries between a weld sub-region and its neighboring plate (or forging) sub-regions. Each weld sub-region will have at most two adjacent plate (or forging) sub-regions.
FAVOR checks to determine if the value of RTNDT of the weld sub-region of interest is higher than the corresponding values of the adjacent plate (or forging) sub-regions.
This determination of whether the weld sub-region or an adjacent plate (or forging) sub-region is controlling (i.e., has the higher RTNDT) is performed one time before entering the PFM Monte Carlo looping structure. For each sub-region, the calculation uses the user-specified mean values of chemistry, RTNDTo, and neutron fluence. Furthermore, the computation of RTNDT for each sub-region includes the correction factors (i.e., 0.99 and 1.10) for weld and plate, respectively. The latter is necessary for consistency, since those factors are applied for all crack tip RTNDT computations performed inside of the Monte Carlo looping structure.
131 Fig. A1. FAVOR uses a discretization of the RPV beltline region to resolve the variation in radiation damage in terms of plate, axial weld, and circumferential weld major regions which are further discretized into multiple subregions.
The output file RTNDT.out contains a summary of the one-time computation to determine which sub-region (weld or adjacent plate) is controlling for flaws analyzed in that weld sub-region. That file does not include results for each weld / adjacent plate, but only for the sub-region with the higher RTNDT.
Also, values found in the file RTNDT.out will not correspond to values of RTNDT reported in the FAVPFM output report. The value of RTNDT reported for each major region in the FAVPFM output report is the maximum value of RTNDT of any sub-region in that major region, calculated without the 0.99 and 1.10 correction factors discussed above.
Restriction on Embrittlement Map Inside the Monte Carlo looping analysis, when a flaw is postulated to reside in a weld, the values of chemistry (sampled from the appropriate distributions) of the controlling sub-region and the sampled value of fluence of the weld, are used in the evaluation of RTNDT at the crack tip. Flaw orientation is not transferred from a dominant plate sub-region to a weld sub-region.
To ensure that the FAVOR weld-fusion line methodology produces logically consistent solutions, it is essential that the same neutron fluence of a weld be assigned to its two adjacent neighbor
132 plate sub-regions. The latter restriction on the embrittlement map input to FAVOR necessitates special treatment for certain problems to be analyzed with FAVOR.
An example would be the use of an embrittlement map constructed based only on knowledge of the maximum value of fluence in any weld, plate, or forging, and where these maximum values are assigned to represent the fluence for the entire major region. If that maximum value of fluence in the plate or forging resides far from the adjacent weld, the resultant model is likely to have an unrealistic discontinuity of fluence between the weld sub-regions and adjacent plates sub-regions that will produce an illogical solution.
For this example, it is recommended that two thin (i.e., very small values ) plate sub-regions be modelled between the weld and adjacent plates, one on each side of the weld. These two sub-regions should be modelled with (1) the chemistry and RTNDT0 of the respective adjacent plates and (2) a fluence equal (or close) to that of the weld, thus providing greater similarity of fluence between the weld and plate along the weld fusion line. This smoother transition in the fluence avoids a possibility of inconsistent results associated with discontinuities between fluence in welds and adjacent plates. Since the assigned to these regions is very small, they occupy negligible volume, have a negligible number of flaws, and thus have little or no other impact on the results of the PFM analysis.
Weld-Fusion-Line Dependency for Ductile Tearing Model For the Ductile Tearing Model No. 2, implemented in FAVOR, v03.1, a second weld-fusion-line dependency structure is created based on the irradiated upper-shelf energy, USE. This weld-fusion-line dependency structure for sampling ductile-tearing properties is independent of the embrittlement-related dependency structure discussed above. For Ductile-tearing Model No. 2, the ductile-tearing-related properties of the most limiting (either the weld or the adjacent plate subregion with the lowest value of irradiated USE) material are used when evaluating ductile-tearing of a flaw located in the weld subregion. As with the embrittlement-related weld-fusion-line treatment, the flaw type and pre-and post-initiation orientation of flaws are not transferred from a dominant plate subregion to a weld subregion. Ductile-Tearing Model No. 1, implemented in FAVOR, v07.1, this second weld-fusion-line dependency structure for sampling ductile-tearing properties is not required.
For those conditions in which plate embrittlement properties are used to characterize the weld subregion fracture toughness, the weld chemistry re-sampling protocols continue to be applied.
133
- 7. Appendix B - Summary of RVID2 Data for Use in FAVOR Calculations
134 Product Form Heat Beltline flow(u)
[ksi]
RTNDT(u) [oF]
Composition(2)
USE(u)
[ft-lb]
RTNDT(u)
Method RTNDT(u)
Value (u)
Value Cu Ni P
Mn Beaver Valley 1, (Designer: Westinghouse, Manufacturer: CE)
Coolant Temperature = 547F, Vessel Thickness = 7-7/8 in.
PLATE C4381-1 INTERMEDIATE SHELL B6607-1 83.8 MTEB 5-2 43 0
0.14 0.62 0.015 1.4 90 C4381-2 INTERMEDIATE SHELL B6607-2 84.3 MTEB 5-2 73 0
0.14 0.62 0.015 1.4 84 C6293-2 LOWER SHELL B7203-2 78.8 MTEB 5-2 20 0
0.14 0.57 0.015 1.3 84 C6317-1 LOWER SHELL B6903-1 72.7 MTEB 5-2 27 0
0.2 0.54 0.01 1.31 80 LINDE 1092 WELD 305414 LOWER SHELL AXIAL WELD 20-714 75.3 Generic
-56 17 0.337 0.609 0.012 1.44 98 305424 INTER SHELL AXIAL WELD 19-714 79.9 Generic
-56 17 0.273 0.629 0.013 1.44 112 LINDE 0091 WELD 90136 CIRC WELD 11-714 76.1 Generic
-56 17 0.269 0.07 0.013 0.964 144 Oconee 1, (Designer and Manufacturer: B&W)
Coolant Temperature = 556F, Vessel Thickness = 8.44-in.
FORGING AHR54 (ZV2861)
LOWER NOZZLE BELT (4)
B&W Generic 3
31 0.16 0.65 0.006 (5) 109 PLATE C2197-2 INTERMEDIATE SHELL (4)
B&W Generic 1 26.9 0.15 0.5 0.008 1.28 81 C2800-1 LOWER SHELL (4)
B&W Generic 1 26.9 0.11 0.63 0.012 1.4 81 C2800-2 LOWER SHELL 69.9 B&W Generic 1 26.9 0.11 0.63 0.012 1.4 119 C3265-1 UPPER SHELL 75.8 B&W Generic 1 26.9 0.1 0.5 0.015 1.42 108 C3278-1 UPPER SHELL (4)
B&W Generic 1 26.9 0.12 0.6 0.01 1.26 81 LINDE 80 WELD 1P0962 INTERMEDIATE SHELL AXIAL WELDS SA-1073 79.4 B&W Generic
-5 19.7 0.21 0.64 0.025 1.38 70 299L44 INT./UPPER SHL CIRC WELD (OUTSIDE 39%) WF-25 (4)
B&W Generic
-7 20.6 0.34 0.68 (3) 1.573 81 61782 NOZZLE BELT/INT. SHELL CIRC WELD SA-1135 (4)
B&W Generic
-5 19.7 0.23 0.52 0.011 1.404 80 71249 INT./UPPER SHL CIRC WELD (INSIDE 61%) SA-1229 76.4 ASME NB-2331 10 0
0.23 0.59 0.021 1.488 67 72445 UPPER/LOWER SHELL CIRC WELD SA-1585 (4)
B&W Generic
-5 19.7 0.22 0.54 0.016 1.436 65 8T1762 LOWER SHELL AXIAL WELDS SA-1430 75.5 B&W Generic
-5 19.7 0.19 0.57 0.017 1.48 70 8T1762 UPPER SHELL AXIAL WELDS SA-1493 (4)
B&W Generic
-5 19.7 0.19 0.57 0.017 1.48 70 8T1762 LOWER SHELL AXIAL WELDS SA-1426 75.5 B&W Generic
-5 19.7 0.19 0.57 0.017 1.48 70 Pallisades, (Designer and Manufacturer: CE)
Coolant Temperature = 532F, Vessel Thickness = 81/2 in.
PLATE A-0313 D-3803-2 (4)
MTEB 5-2
-30 0
0.24 0.52 0.01 1.35 87 B-5294 D-3804-3 (4)
MTEB 5-2
-25 0
0.12 0.55 0.01 1.27 73 C-1279 D-3803-3 (4)
ASME NB-2331
-5 0
0.24 0.5 0.011 1.293 102
135 Product Form Heat Beltline flow(u)
[ksi]
RTNDT(u) [oF]
Composition(2)
USE(u)
[ft-lb]
RTNDT(u)
Method RTNDT(u)
Value (u)
Value Cu Ni P
Mn C-1279 D-3803-1 74.7 ASME NB-2331
-5 0
0.24 0.51 0.009 1.293 102 C-1308A D-3804-1 (4)
ASME NB-2331 0
0 0.19 0.48 0.016 1.235 72 C-1308B D-3804-2 (4)
MTEB 5-2
-30 0
0.19 0.5 0.015 1.235 76 LINDE 0124 WELD 27204 CIRC. WELD 9-112 76.9 Generic
-56 17 0.203 1.018 0.013 1.147 98 LINDE 1092 WELD 34B009 LOWER SHELL AXIAL WELD 3-112A/C 76.1 Generic
-56 17 0.192 0.98 (3) 1.34 111 W5214 LOWER SHELL AXIAL WELDS 3-112A/C 72.9 Generic
-56 17 0.213 1.01 0.019 1.315 118 W5214 INTERMEDIATE SHELL AXIAL WELDS 2-112 A/C 72.9 Generic
-56 17 0.213 1.01 0.019 1.315 118 Notes:
(1) Information taken from the July 2000 release of the NRCs Reactor Vessel Integrity (RVID2) database.
(2) These composition values are as reported in RVID2 for Cu, Ni, and P and as in RPVDATA for Mn. In FAVOR calculations these values should be treated as the central tendency of the Cu, Ni, P, and Mn distributions.
(3) No values of phosphorus are recorded in RVID2 for these heats. A generic value of 0.012 should be used, which is the mean of 826 phosphorus values taken from the surveillance database used by Eason et al. to calibrate the embrittlement trend curve.
(4) No strength measurements are available in PREP4 for these heats [PREP]. A value of 77 ksi should be used, which is the mean of other flow strength values reported in this Appendix.
(5) No values of manganese strength in RPVDATA for these heats [ref]. A generic value of 0.80 should be used, which is the mean value of manganese for forgings taken from the surveillance database used by Eason et al. to calibrate the embrittlement trend curve.
References:
RVID2 U.S. Nuclear Regulatory Commission Reactor Vessel Integrity Database, Version 2.1.1, July 6, 2000.
PREP PREP4: Power Reactor Embrittlement Program, Version 1.0," EPRI, Palo Alto, CA: 1996. SW-106276 RPVDATA T. J. Griesbach, and J.F. Williams, Users Guide to RPVDATA,Reactor Vessel Materials Database, Westinghouse Energy Systems Business Unit, WCAP-14616, 1996.
136
- 8. Appendix C - As-Found Flaw FAVPFM Version 20.1 Input C.1 Introduction The FAVOR code, specifically the FAVPFM subcode, has used the flaw characterization input from the previously developed VFLAW (References [1], [2], [3], and [4]) based approach on RPVs. VFLAW was developed at the Pacific Northwest National Laboratory (PNNL). The technical basis for VFLAW is based on from flaw data obtained from the destructive examination of RPV materials [1]. VFLAW provides statistical distributions of the number and the geometry of flaws that could exist in a reactor pressure vessel (RPV). This application has been useful in the generic evaluation of surface, plate, and weld flaws in RPVs, particularly in the Pressurized Thermal Shock (PTS) reevaluation. More recently, an approach was developed to evaluate a large number of quasi-laminar flaws identified by ultrasonic inspection of the Doel 3 and Tihange 2 RPV lower and upper core shells (Reference [5]). A modified version of FAVPFM was developed to perform a conservative deterministic evaluation of these Doel 3 and Tihange 2 RPV flaws (Note that this modification to FAVOR 16.1 was not released). Because concerns with these flaws could be resolved with this conservative deterministic analysis, a probabilistic fracture mechanics (PFM) evaluation was not required. Because future RPV examinations may require PFM analysis to support decisions on continued plant operation with newly identified flaws, an as-found flaw version of FAVPFM (Version 20.1) has been developed. This as-found flaw FAVOR code is designed to assess identified flaws from in-service inspections where specific and unique flaw characterizations are identified.
C.2 FAVPFM As-Found Flaw Input Flag - IPFLAW The user-input variable IPFLAW (flaw population) in the FAVPFM input dataset activates the as-found flaw option of FAVPFM. All other FAVPFM input variable records remain the same in number, description, and format as FAVOR 16.1. In the 16.1 version of FAVOR, IPFLAW =1, 2, or 3 on Record 1 (i.e., CNT1) defines the flaw population to be used in PFM analyses as follows:
IPFLAW = 1: All surface breaking flaws are assumed to be on the inner surface of the RPV. Only those embedded flaws in the 3/8th of the base metal nearest the RPV inner (wetted) surface are included in the analyses and they are uniformly distributed. This option is meant for cool-down transients based on the assumption that external surface breaking flaws and embedded flaws beyond the inner 3/8th of the base metal are primarily in compressive stress fields during cool-down transients and would therefore would never initiate in fracture.
IPFLAW = 2: All surface breaking flaws are assumed to be on the external surface of the RPV. Only those embedded flaws in the 3/8th of the base metal nearest the RPV outer surface are included in the analyses and they are uniformly distributed. This option is meant for heat-up transients based on the assumption that internal surface breaking flaws and embedded flaws in the inner 3/8th of the base metal are primarily in compressive stress fields during heat-up transients and would therefore would never initiate in fracture. It has since been found that this is not necessarily always a valid assumption
137 as internal surface breaking flaws can also initiate exceedingly early in some cases during some heat-up transients.
IPFLAW = 3: Results in double the number of surface breaking flaws in either of the above options.
Half are internal and half are external of surface breaking flaws. Embedded flaws are uniformly distributed thru the entire wall thickness and results in (8/3) as many embedded flaws as either of the above options. This option can be used for any case; however, was primarily designed for the hydrostatic test load condition, which consists of both a heat-up and cool-down phase. This option requires more computational time to perform a PFM analysis; however, there are no questions regarding what if all possible flaws had been included in the analysis.
In the 20.1 version of FAVOR, IPFLAW = 1,2, or 3, FAVPFM will continue to prompt the user for three flaw characterization files discussed above and will generate identical solutions as the 16.1 version of FAVOR thus providing backward compatibility.
If IPFLAW = 4, FAVPFM will prompt the user for a single flaw file which characterizes the as-found flaws which, in the general case, can be any combination of surface breaking flaws / embedded flaws /
material / flaw orientation. For IPFLAW=4, FAVPFM will generate PFM solutions for the set of as-found flaws.
C.3 Content and Format for As-Found Flaw Distribution File User input is entered in free format style. The first record must contain 201 to indicate v20.1 of FAVPFM is being used. Each record following the first must include seven (7) free-formatted values as described in Table C.1 below.
Note that in-service inspection results are typically based on ASME flaw dimensional terminology which needs to be converted to FAVOR based input. As-found flaws as described herein are related to those found in non-destructive examinations and have been characterized per ASME code, ASME Boiler and Pressure Vessel Code - Rules for Inservice Inspection of Nuclear Power Plant Components [6]. The following sections of the ASME code can assist users to provide flaw specifications into the new FAVPFM module:
IWA-3300, Flaw Characterization, IWB-3600, Analytical Evaluation of Planar Flaws, Nonmandatory Appendix A, Analytical Evaluation of Flaws, and Nonmandatory Appendix G, Fracture Toughness Criteria for Protection Against Failure.
ASME Code Case N-848 [7].
The above referenced ASME sections layout the requirements on how to characterize and analyze flaws discovered in NDE of reactor vessels, particularly flaw characterization, multiple flaws, and proximity rules to other flaws. The current FAVOR code and associated modules do not take actual NDE
138 surveillance data as direct input. The geometry of flaws assumed within the current v16.1 of FAVOR assume elliptical geometry, axial or circumferential, and discrete aspect ratios, whereas in reality, flaws found in surveillances are not exactly elliptical, axial, or circumferential, nor have a simple aspect ratio.
Therefore, the translation from these NDE discovered flaws require a translation based on the ASME code or newly developed method to evaluate any geometry and type of flaw (e.g., surface, or embedded),
and orientation. The user must interpret the NDE results and characterize the flaws according to the ASME code. An example application of this transformation is described in Appendix A of Reference [5].
IWA-3300 of the ASME Code describes the standard used for flaw characterization. A sample characterization of flaws from NDE is shown below. The guidance in IWA-3300 is used in characterization all flaws that can be modeled as elliptical flaws in the axial and/or circumferential direction as illustrated in the ASME evaluation of flaws in either IWB-3600, Analytical Evaluation of Planar Flaws or Appendix A, Analytical Evaluation of Flaws.
Application of FAVPFM to assessments of various oriented and sized flaws requires a flaw characterization that meets the following requirements:
axial and/or circumferential flaws normal to principal stress directions of the RPV that are amenable to Mode I fracture mechanics analysis, for embedded (non-surface) flaws, the configuration must be fully elliptical, and flaws are assumed mechanically independent, i.e., flaws do not interact.
The effects of proximity of flaws, their interaction, and flaw orientation were examined in two papers [
[8] - [9)) and translated into the ASME Code Case N-848 [7]. These documents provide acceptable rules to incorporate flaw interaction and orientation effects for quasi-laminar and planar flaws based on their alignment and distance between them. The approach described in ASME Code Case N-848 [7] is to characterize such flaws by defining a bounding box (Figure C.1 and Figure C.2) for an individual flaw, a grouped flaw (two or more quasi-laminar flaws), or an extended combined flaw (containing also a planar flaw). The bounding box (containing a single flaw or grouped flaws) is resolved into two rectangular planar flaws, each corresponding to the faces of the box normal to the principal stresses. The two planar flaws must be:
normal to the hoop and axial stress directions, retain the surface/subsurface characterization defined for a combined flaw, assume the dimensions of the relevant surfaces of the bounding box, and have been evaluated (per ASME code requirements) such there are no interactions to other flaws outside the bounded box.
The major and minor axes of each ellipse are defined such that the major axes of the ellipse are in the same ratio as the sides of the rectangle, and the area of the ellipse is the same as the area of the corresponding rectangle. Thus, the flaw characterization as input to FAVPFM contains two elliptical
139 flaws, one for the axial and one for the circumferential component, which are normal to the hoop and axial stresses, respectively.
Further detail on how the transformation is applied is described in Reference [5] and summarized below:
In order to define the elliptical flaws, the criteria used was that the major axes of the ellipse are in the same ratio as the sides of the rectangle, and the area of the ellipse is the same as the area of the corresponding rectangle. Using these two criteria, it is possible to determine the major and minor axes of the ellipse. As shown in Figure C.3: Rectangle and Ellipse Having the Same Area and Same Aspect Ratio Figure C.3, given a rectangle with sides a and b, we need to determine the semi-major and semi-minor axes l and d. The centers of the rectangle and ellipse are also assumed to be at the same point. If we require the major and minor axes of the ellipse to be in the same ratio as the length and width of the rectangle, and the area of the rectangle and ellipse to also be the same, then
=
and x = x x.
(Equation C.1)
Using the above equations, = /, and =
The quantities needed by FAVPFM to define the flaw geometry are the distance to the inner crack tip from the inside (pressure bearing) surface of the vessel, the depth, and the aspect ratio of the flaw. Note that FAVOR defines the aspect ratio as the reciprocal of the ASME based definition.
Figure C.1: Diagonals and Angles used to Specify the Flaw Indication
140 Figure C.3: Rectangle and Ellipse Having the Same Area and Same Aspect Ratio Figure C.2: Bounding Box for Flaw Indication Showing Two Resolved Elliptical Flaws Normal to the Axial and Hoop Stress Directions
141 Table C. 1: As-Found Flaw Input File
- 1.
Defines variable IKIND in the code, where 1=ISB internal surface breaking flaw; and 2=EMB embedded flaw.
External surface breaking flaws are not modeled in v20.1.
- 2.
Orientation: 1 = axial; 2 = circumferential
- 3.
See Figures C.4 to C.7
- 4.
Only applicable for embedded flaws. Value is variable xinner in the code, which is the location of inner crack tip of embedded flaw relative to wetted inner surface.
Sample As-Found File Input 201 1 2 10 1 0.08750 8.122547752408 2.319516368985 2 2 13 2 0.08750 3.676104057742 0.588145364364 3 2 4 1 1.05000 8.970125137961 2.820941348826 4 2 7 2 0.52500 17.904967736172 1.535381603127 5 2 9 1 0.26250 2.738724758689 1.697111095184 6 2 8 2 0.17500 9.272502839534 3.027352722223 7 2 8 1 0.08750 3.108261145271 1.038243792798 8 2 3 1 0.26250 1.687684417897 2.120970082038 9 2 9 2 0.17500 1.354105412765 0.964943350649 10 2 6 1 0.43750 5.169382196556 1.940942253535 11 1 9 2 0.17500 6 0.000000000000 12 2 7 2 0.17500 2.122181346809 1.724890895003 13 1 13 2 2.18750 6 0.000000000000 5254 2 10 1 0.26250 2.060330675969 1.278463196817 Flaw Unique ID Number -
(Up to 5 characters)
Flaw Type(1) 1=ISB and 2=Embedded Subregion In which flaw resides Orientation(2) 1=Axial 2=Circum.
Depth(3)
(inches)
Aspect(3)
Ratio Radial(4)
Location (inches)
ABC12 1
13 1
2.1875 6
0 ABD45 2
10 2
0.8750 8.122 2.32 N
2 8
1 0.0875 3.108 1.038
142 Figure C.4: Illustration of Axially Oriented ISB, ESB, and Embedded Flaws Figure C.5: Illustration of Circumferentially Oriented ISB Flaws
143 Figure C.6: Illustration of Embedded Flaw - Inner Half of RPV Wall Thickness : Depth = 2a, Aspect Ratio = L / 2a, Distance of Inner Crack Tip from Wetted Inner Surface = X1 = c + tclad
144 Figure C.7: Illustration of Embedded Flaw - Outer Half of RPV Wall Thickness : Depth = 2a, Aspect Ratio = l / 2a, Distance of Inner Crack Tip from Wetted Inner Surface = c + tclad
145 C.4 FAVOR PFM Module - FAVPFM Output for As-Found Flaw Input When both IPFLAW is set to 4 and IQA is set to 0 (PFM analysis), FAVPFM produces the following files:
General Output Files (1)
Filename defined by user at execution (e.g., FAVPFM.OUT)
(2)
Echo of input file with filename defined by user at execution (e.g., FAVPFM.echo)
(3)
Echo of the as-found flaw input file with filename defined by user at execution (e.g.,
FAVPFM.aff.echo)
(4)
Binary restart file - restart.bin Input files for FAVPost (5)
FAILURE.DAT (6)
INITIATE.DAT QA Verification Files (7)
ARREST.OUT (8)
CPF_history.out (9)
CPI_history.out (10)
NSIM.DAT (11)
FLAWNO.OUT (12)
FLAWSIZE.OUT (13)
TRACE.OUT (14)
FLAW_TRACK.LOG (15)
History_itran_iseq.out (NTRAN files where itran is the FAVOR transient number and iseq is its associated and unique thermal-hydraulic initiating-event sequence number)
See the Version 16.1 User Guide for partial listings of example files: (2) FAVPFM.echo, (7) ARREST.OUT, (11) FLAWNO.OUT, (12) FLAWSIZE.OUT, (13) TRACE.OUT, (14) FLAW_
TRACK.LOG, and (15) History_itran_iseq.out.
FAVPFM.aff.echo includes two sections:
(1)
Echo of all input flaw data from the user specified as-found flaw file.
(2)
Summary of the flaw characterization from the user input data.
146 FAVPFM.out includes results for all transients in this case definition including:
(1)
Mean value of conditional probability of initiation (CPI)
(2)
Mean value of conditional probability of failure (CPF)
(3)
Flaw distribution report by RPV Beltline Region including maximum RTNDT (4)
Mean value of RTNDT at crack tip (5)
Allocation of Risk Table for each Transient - Sorted by % of CPI containing the following:
- a. Unique flaw ID and flaw characteristics (Kind, depth, aspect ratio, subregion flaw resides, crack tip location, orientation)
- b. Average RTNDT
- d. Mean value of CPF from this unique flaw and % of total contribution to CPF due to all flaws (6)
Allocation of Risk Table for each Transient - Sorted by % of CPF containing the following:
- a. Unique flaw ID and flaw characteristics (same as for CPI)
- b. Average RTNDT
- d. Mean value of CPF from this unique flaw and % of total contribution to CPF due to all flaws (7)
Flaw Distribution by Material and Category (8)
Flaw Distribution by Material, Category, and Orientation (9)
Weld Flaw-Size Distribution Report (10)
Plate Flaw-Size Distribution Report (11)
Transient Time Distribution Report (12)
Probability and Cumulative Distribution Functions for the Initiating Driving Force (13)
Failure Mechanism Report (14)
Following all reports for each transient, a Multiple Flaw Statistics Summary
147 FAVPFM As-Found File Echo (*.aff.echo) - (Partial Listing)
- WELCOME TO FAVOR *
- FRACTURE ANALYSIS OF VESSELS: OAK RIDGE *
- VERSION 20.1 *
- INCLUDES AS-FOUND FLAW OPTION *
- FAVPFM MODULE: PERFORMS PROBABILISTIC *
- FRACTURE MECHANICS ANALYSES *
- PROBLEMS OR QUESTIONS REGARDING FAVOR *
- SHOULD BE DIRECTED TO: *
- UNITED STATES NUCLEAR REGULATORY COMMISSION *
- Office of Nuclear Regulatory Research *
- e-mail: patrick.raynaud@nrc.gov *
- phone: (301) 415-1987 *
- This computer program was prepared as an account of *
- work sponsored by the United States Government *
- Neither the United States, nor the United States *
- Department of Energy, nor the United States Nuclear *
- Regulatory Commission, nor any of their employees, *
- nor any of their contractors, subcontractors, or their *
- employees, makes any warranty, express or implied, or *
- assumes any legal liability or responsibility for the *
- accuracy, completeness, or usefulness of any *
- information, apparatus, product, or process disclosed, *
- or represents that its use would not infringe *
- privately-owned rights.
- DATE: 29-Jul-2020 TIME: 11:58:55 FAVPFM INPUT FILE NAME = pfm1000.in FAVLOAD OUTPUT FILE NAME = lpts1.out FAVPFM OUTPUT FILE NAME = pfm46c-1000ordered.out FAVPFM INPUT ECHO FILE NAME = pfm46c-1000ordered.echo AS-FOUND FLAW FILE NAME = pws5254ext.dat AS-FOUND FLAW INPUT ECHO FILE NAME = pfm46c-1000ordered.aff.echo Begin echo of FAVPFM input data deck 11:58:55 29-Jul-2020 no./col.
1.......10........20........30........40........50........60........70........80........90.......100.......110.......12 0.......130 1 201 2 1 2 10 1 0.08750 8.122547752408 2.319516368985 3 2 2 13 2 0.08750 3.676104057742 0.588145364364 4 3 2 4 1 1.05000 8.970125137961 2.820941348826 5 4 2 7 2 0.52500 17.904967736172 1.535381603127 6 5 2 9 1 0.26250 2.738724758689 1.697111095184 7 6 2 8 2 0.17500 9.272502839534 3.027352722223 8 7 2 8 1 0.08750 3.108261145271 1.038243792798 9 8 2 3 1 0.26250 1.687684417897 2.120970082038 10 9 2 9 2 0.17500 1.354105412765 0.964943350649 11 10 2 6 1 0.43750 5.169382196556 1.940942253535 12 11 1 9 2 0.17500 6 0.000000000000 5250 5249 2 1 1 0.08750 2.499498945366 3.141515258472 5251 5250 2 9 1 0.17500 1.377335146559 0.399642828505 5252 5251 2 12 2 0.08750 6.931782017943 0.326257855238 5253 5252 2 11 1 0.08750 3.418544982793 2.144354387388 5254 5253 2 9 2 0.08750 2.906510364213 2.534569708062 5255 5254 2 10 1 0.26250 2.060330675969 1.278463196817 no./col.
1.......10........20........30........40........50........60........70........80........90.......100.......110.......12 0.......130 End echo of FAVPFM input data deck 11:58:55 29-Jul-2020
==================================
- Characteristics of As-Found Flaws *
==================================
Flaw Flaw Depth Crack tip Aspect Flaw Sub ID# KIND (inch) (inch) ratio ORNT region 1 2 0.087 2.320 8 1 10 2 2 0.087 0.588 3 2 13
148 FAVPFM As-Found File Echo (*.aff.echo) - (Partial Listing) - (Continued) 3 2 1.050 2.821 8 1 4 4 2 0.525 1.535 17 2 7 5 2 0.263 1.697 2 1 9 6 2 0.175 3.027 9 2 8 7 2 0.087 1.038 3 1 8 8 2 0.263 2.121 1 1 3 9 2 0.175 0.965 1 2 9 10 2 0.438 1.941 5 1 6 11 1 0.175 0.175 6 2 9 12 2 0.175 1.725 2 2 7 13 1 2.188 2.188 6 2 13 5242 2 0.087 3.159 1 2 11 5243 2 0.263 1.828 2 1 13 5244 2 0.087 1.247 1 1 3 5245 2 0.263 1.917 1 2 8 5246 2 0.087 2.055 4 1 2 5247 2 0.087 1.149 12 2 7 5248 2 0.087 1.032 7 1 3 5249 2 0.087 3.142 2 1 1 5250 2 0.175 0.400 1 1 9 5251 2 0.087 0.326 6 2 12 5252 2 0.087 2.144 3 1 11 5253 2 0.087 2.535 2 2 9 5254 2 0.263 1.278 2 1 10
149 FAVPFM As-Found Output File (*.out)
- WELCOME TO FAVOR *
- FRACTURE ANALYSIS OF VESSELS: OAK RIDGE *
- VERSION 20.1 *
- INCLUDES AS-FOUND FLAW OPTION *
- FAVPFM MODULE: PERFORMS PROBABILISTIC *
- FRACTURE MECHANICS ANALYSES *
- PROBLEMS OR QUESTIONS REGARDING FAVOR *
- SHOULD BE DIRECTED TO: *
- UNITED STATES NUCLEAR REGULATORY COMMISSION *
- Office of Nuclear Regulatory Research *
- e-mail: patrick.raynaud@nrc.gov *
- phone: (301) 415-1987 *
- This computer program was prepared as an account of *
- work sponsored by the United States Government *
- Neither the United States, nor the United States *
- Department of Energy, nor the United States Nuclear *
- Regulatory Commission, nor any of their employees, *
- nor any of their contractors, subcontractors, or their *
- employees, makes any warranty, express or implied, or *
- assumes any legal liability or responsibility for the *
- accuracy, completeness, or usefulness of any *
- information, apparatus, product, or process disclosed, *
- or represents that its use would not infringe *
- privately-owned rights.
- DATE: 29-Jul-2020 TIME: 11:58:36 FAVPFM INPUT FILE NAME = pfm1000.in FAVLOAD OUTPUT FILE NAME = lpts1.out FAVPFM OUTPUT FILE NAME = pfm46c-1000ordered.out FAVPFM INPUT ECHO FILE NAME = pfm46c-1000ordered.echo Binary restart files will be created using a checkpoint interval of **** trials.
NUMBER OF TIME STEPS IN FAVLoad FILE = 251 NUMBER OF IGA TRIALS PER FLAW = 100 FLOW STRESS - USED IN FAILURE ANALYSIS = 80.0 ksi Maximum value used for KIc and KIa = 200.0 ksi-in^1/2 KIc/KIa cap not used if ductile-tearing model is invoked.
Stochastic model for crack arrest KIa = 1 where 1 = model based on high-constraint CCA specimens 2 = model based on CCA and large-specimen data KIa model set to 2 if ductile-tearing model is invoked.
Radiation embrittlement correlation = 992 where 992 = Regulatory Guide 1.99, revision 2 2000 = Eason 2000 2006 = Eason 2006 20071 = EricksonKirk 2007 20072 = RADAMO 2007 20073 = Combined EricksonKirk 2007 + RADAMO 2007 Steady-state cooling water temperature = 550. degrees F Effective full-power years of operation = 72.
DEFINITION OF STANDARD DEVIATIONS FOR SIMULATING THE FOLLOWING PARAMETERS SURFACE NEUTRON FLUENCE - GLOBAL = 0.118* BEST ESTIMATE VALUE SURFACE NEUTRON FLUENCE - LOCAL = 0.056* BEST ESTIMATE VALUE COPPER - WELD = 0.167 wt %
COPPER - PLATE = 0.0073 wt %
NICKEL - PLATE = 0.0244 wt %
PHOSPHORUS - WELD = 0.0013 wt %
PHOSPHORUS - PLATE = 0.0013 wt %
150 FAVPFM As-Found Output File (*.out) - (Continued)
NUMBER OF VESSEL SUBREGIONS: WELD= 7 PLATE= 6 TOTAL= 13 NUMBER OF VESSEL MAJOR REGIONS: WELD= 7 PLATE= 6 TOTAL= 13
- PFM ANALYSIS RESULTS *
- INITIAL RANDOM NUMBER GENERATOR SEEDS : 1234567890 123456789 *
- IPFLAW=4: AS-FOUND FLAW OPTION **
- WELD LAYER RESAMPLING TURNED ON **
- WARM-PRESTRESS OPTION 1 CHOSEN: **
- TO HAVE A NON-ZERO instantaneous conditional **
- probability of crack initiation at a discrete **
- transient time step: **
- applied KI must be greater than the Weibull **
- "a" parameter **
- AND **
- applied KI MUST EXCEED MAXIMUM KI at all **
- previous discrete transient time steps **
- DO NOT ANALYZE CATEGORY 3 PLATE FLAWS **
- DUCTILE-TEARING MODEL TURNED OFF **
- FAILURE CRITERIA a/t = 0.90 **
- PFM RESULTS FOR TRANSIENT NUMBER 1 **
- NUMBER OF COMPLETED TRIALS = 1000 **
MEAN VALUE OF CPI = 4.921E-01 MEAN VALUE OF CPF = 2.864E-02
- RPV BELTLINE MAJOR REGION REPORT *
- BY PARENT SUBREGION *
========================================================================================
FAVPFM As-Found Output File (*.out) - (Continued) l---Initiation---l l----Cleavage----l l------Ductile-----l MAJOR RTndt % OF SIMULATED # of FLAWS % of # of FLAWS % of # of FLAWS % of REGION (MAX) FLAWS FLAWS CPI > 0 CPI CPF > 0 CPF CPF > 0 CPF
========================================================================================
1 241.6 3.24 170000 1789 2.74 1788 17.23 0 0.00 2 254.9 2.66 140000 3391 0.87 3389 13.90 0 0.00 3 254.9 2.53 133000 3257 3.00 3257 35.50 0 0.00 4 255.5 4.26 224000 4830 4.09 3951 13.81 0 0.00 5 242.1 4.23 222000 2184 0.43 2184 4.36 0 0.00 6 255.5 4.61 242000 3429 4.05 3123 5.08 0 0.00 7 260.7 26.99 1418000 36632 18.81 0 0.00 0 0.00 8 179.8 6.62 348000 1997 1.56 216 0.06 0 0.00 9 152.9 6.95 365000 439 0.25 7 0.00 0 0.00 10 89.5 7.50 394000 0 0.00 0 0.00 0 0.00 11 217.3 10.16 534000 12165 21.01 1763 1.12 0 0.00 12 194.3 10.03 527000 6863 9.34 856 0.58 0 0.00 13 215.3 10.22 537000 14466 33.85 2688 8.38 0 0.00
========================================================================================
TOTALS 100.00 5254000 91442 100.00 23222 100.00 0 0.00
========================================================================================
NOTE: MEAN VALUE OF RTNDT AT CRACK TIP= 162.84
=========================================================
=========================================================
Flaw Flaw Depth Aspect Sub Crack tip Flaw average % of % of ID# KIND (inch) ratio Region (inch) ORNT RTNDT CPImean CPI CPFmean CPF
151 FAVPFM As-Found Output File (*.out) - (Continued) 3070 1 0.613 99.000 13 0.613 circf 193.20 0.644E-01 6.20 0.000E+00 0.00 5102 1 0.438 99.000 13 0.438 circf 194.74 0.594E-01 5.72 0.000E+00 0.00 721 1 0.787 6.000 7 0.787 circf 200.77 0.544E-01 5.24 0.000E+00 0.00 800 1 0.787 99.000 11 0.787 circf 193.09 0.522E-01 5.02 0.356E-07 0.00 4340 1 0.787 99.000 11 0.787 circf 192.83 0.511E-01 4.92 0.490E-08 0.00 143 1 0.787 99.000 13 0.787 circf 192.01 0.505E-01 4.86 0.296E-08 0.00 4618 1 0.787 99.000 13 0.787 circf 191.91 0.498E-01 4.80 0.243E-08 0.00 295 1 1.575 99.000 6 1.575 circf 180.81 0.377E-01 3.63 0.000E+00 0.00 3118 1 0.263 99.000 13 0.263 circf 196.40 0.326E-01 3.14 0.000E+00 0.00 4312 2 0.525 12.429 1 0.270 axial 184.34 0.279E-01 2.68 0.492E-02 16.53 2174 1 1.400 6.000 4 1.400 circf 183.30 0.232E-01 2.23 0.000E+00 0.00 330 1 0.438 10.000 11 0.438 circf 196.18 0.204E-01 1.96 0.000E+00 0.00 1936 1 0.438 99.000 12 0.438 circf 172.95 0.201E-01 1.94 0.924E-14 0.00 1451 1 0.438 10.000 13 0.438 circf 194.86 0.187E-01 1.80 0.000E+00 0.00 4019 2 0.438 5.171 7 0.274 circf 205.98 0.184E-01 1.77 0.000E+00 0.00 1048 1 0.525 6.000 11 0.525 circf 195.34 0.164E-01 1.57 0.000E+00 0.00 1050 1 0.525 6.000 11 0.525 circf 195.34 0.163E-01 1.57 0.000E+00 0.00 532 1 0.350 10.000 11 0.350 circf 197.33 0.139E-01 1.33 0.693E-09 0.00 3423 1 0.350 10.000 11 0.350 circf 196.79 0.136E-01 1.31 0.846E-10 0.00 3074 2 0.700 4.424 3 0.491 axial 193.83 0.136E-01 1.31 0.515E-02 17.31 2588 1 0.787 99.000 12 0.787 circf 170.03 0.131E-01 1.26 0.000E+00 0.00 5085 2 0.787 2.310 7 0.459 circf 204.22 0.129E-01 1.25 0.000E+00 0.00 3502 2 0.350 8.158 3 0.265 axial 196.86 0.129E-01 1.24 0.348E-02 11.69 2283 1 0.787 99.000 12 0.787 circf 169.88 0.128E-01 1.23 0.000E+00 0.00 2437 1 0.787 99.000 12 0.787 circf 169.68 0.128E-01 1.23 0.361E-08 0.00 4257 1 0.350 10.000 13 0.350 circf 195.91 0.125E-01 1.21 0.529E-09 0.00 2467 1 0.787 99.000 12 0.787 circf 169.75 0.125E-01 1.20 0.000E+00 0.00 4871 2 0.525 2.875 7 0.374 circf 205.67 0.113E-01 1.08 0.000E+00 0.00 3270 1 0.263 99.000 12 0.263 circf 174.43 0.112E-01 1.08 0.132E-08 0.00 2487 2 0.350 6.147 7 0.268 circf 207.22 0.112E-01 1.08 0.000E+00 0.00 3946 2 0.875 1.880 4 0.651 axial 192.69 0.395E-02 0.38 0.205E-02 6.88 2566 2 0.525 2.466 3 0.482 axial 193.66 0.352E-02 0.34 0.142E-02 4.78 4252 2 0.613 7.323 2 0.678 axial 191.11 0.314E-02 0.30 0.172E-02 5.77 3900 2 0.613 8.316 13 0.443 axial 194.97 0.281E-02 0.27 0.143E-02 4.81 4313 2 0.525 5.332 5 0.557 axial 184.63 0.184E-02 0.18 0.595E-03 2.00 3551 2 0.438 4.107 2 0.558 axial 193.02 0.129E-02 0.12 0.556E-03 1.87 4197 2 0.175 9.365 4 0.255 axial 197.94 0.126E-02 0.12 0.390E-03 1.31 1061 2 0.525 2.533 13 0.376 axial 195.57 0.120E-02 0.12 0.622E-03 2.09 3266 2 0.263 8.486 2 0.359 axial 195.72 0.112E-02 0.11 0.370E-03 1.24 784 2 0.263 5.119 2 0.346 axial 195.53 0.104E-02 0.10 0.346E-03 1.16 3956 2 0.175 9.941 6 0.250 axial 196.64 0.104E-02 0.10 0.341E-03 1.14 2406 2 0.263 12.678 2 0.438 axial 194.69 0.927E-03 0.09 0.400E-03 1.34 1123 2 0.613 1.640 6 0.614 axial 192.53 0.861E-03 0.08 0.487E-03 1.64 5079 2 0.438 5.564 2 0.690 axial 191.38 0.754E-03 0.07 0.418E-03 1.40 4041 2 0.875 1.437 4 0.764 axial 191.58 0.628E-03 0.06 0.374E-03 1.26
=========================================================
- Allocation of Risk by Flaw for Transient 1 - sorted by % of CPF *
=========================================================
Flaw Flaw Depth Aspect Sub Crack tip Flaw average % of % of ID# KIND (inch) ratio Region (inch) ORNT RTNDT CPImean CPI CPFmean CPF 3074 2 0.700 4.424 3 0.491 axial 193.83 0.136E-01 1.31 0.515E-02 17.31 4312 2 0.525 12.429 1 0.270 axial 184.34 0.279E-01 2.68 0.492E-02 16.53 3502 2 0.350 8.158 3 0.265 axial 196.86 0.129E-01 1.24 0.348E-02 11.69 3946 2 0.875 1.880 4 0.651 axial 192.69 0.395E-02 0.38 0.205E-02 6.88 4252 2 0.613 7.323 2 0.678 axial 191.11 0.314E-02 0.30 0.172E-02 5.77 3900 2 0.613 8.316 13 0.443 axial 194.97 0.281E-02 0.27 0.143E-02 4.81 2566 2 0.525 2.466 3 0.482 axial 193.66 0.352E-02 0.34 0.142E-02 4.78 1061 2 0.525 2.533 13 0.376 axial 195.57 0.120E-02 0.12 0.622E-03 2.09 4313 2 0.525 5.332 5 0.557 axial 184.63 0.184E-02 0.18 0.595E-03 2.00 3551 2 0.438 4.107 2 0.558 axial 193.02 0.129E-02 0.12 0.556E-03 1.87 1123 2 0.613 1.640 6 0.614 axial 192.53 0.861E-03 0.08 0.487E-03 1.64 5079 2 0.438 5.564 2 0.690 axial 191.38 0.754E-03 0.07 0.418E-03 1.40 2406 2 0.263 12.678 2 0.438 axial 194.69 0.927E-03 0.09 0.400E-03 1.34 4197 2 0.175 9.365 4 0.255 axial 197.94 0.126E-02 0.12 0.390E-03 1.31 4041 2 0.875 1.437 4 0.764 axial 191.58 0.628E-03 0.06 0.374E-03 1.26 3266 2 0.263 8.486 2 0.359 axial 195.72 0.112E-02 0.11 0.370E-03 1.24 784 2 0.263 5.119 2 0.346 axial 195.53 0.104E-02 0.10 0.346E-03 1.16 3956 2 0.175 9.941 6 0.250 axial 196.64 0.104E-02 0.10 0.341E-03 1.14
- FLAW DISTRIBUTION BY MATERIAL AND CATEGORY *
- BY PARENT SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
FLAW CATEGORY 1(int) 8000 1777 12.18 0 0.00 FLAW CATEGORY 2(int) 849000 53639 21.81 17648 89.85 FLAW CATEGORY 3(int) 1692000 96 0.00 44 0.02
======================================
TOTALS 2549000 55512 33.98 17692 89.87
======================================
152 FAVPFM As-Found Output File (*.out) - (Continued)
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
FLAW CATEGORY 1(int) 212000 24790 64.51 233 0.01 FLAW CATEGORY 2(int) 863000 11140 1.51 5297 10.12 FLAW CATEGORY 3(int) 1630000 0 0.00 0 0.00
======================================
TOTALS 2705000 35930 66.02 5530 10.13
======================================
- FLAW DISTRIBUTION BY MATERIAL, CATEGORY, & ORIENTATION *
- BY PARENT SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 0 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 367000 17651 8.24 17648 89.85 AXIAL FLAW CATEGORY 3 758000 44 0.00 44 0.02
======================================
AXIAL SUBTOTALS 1125000 17695 8.24 17692 89.87
======================================
CIRC. FLAW CATEGORY 1 8000 1777 12.18 0 0.00 CIRC. FLAW CATEGORY 2 482000 35988 13.57 0 0.00 CIRC. FLAW CATEGORY 3 934000 52 0.00 0 0.00
======================================
CIRC. SUBTOTALS 1424000 37817 25.74 0 0.00
======================================
WELD TOTALS 2549000 55512 33.98 17692 89.87
======================================
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 0 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 415000 5225 0.58 5225 10.12 AXIAL FLAW CATEGORY 3 832000 0 0.00 0 0.00
======================================
AXIAL SUBTOTALS 1247000 5225 0.58 5225 10.12
======================================
CIRC. FLAW CATEGORY 1 212000 24790 64.51 233 0.01 CIRC. FLAW CATEGORY 2 448000 5915 0.93 72 0.00 CIRC. FLAW CATEGORY 3 798000 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 1458000 30705 65.43 538 0.01
======================================
PLATE TOTALS 2705000 35930 66.02 5763 10.13
======================================
- WELD FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF INITIATION *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPI>0 CPI flaws CPI>0 CPI flaws CPI>0 CPI
=====================================================================
0.000 - 0.088 1000 0 0.00 435000 3466 0.01 839000 0 0.00 0.088 - 0.175 0 0 0.00 201000 14357 0.92 424000 0 0.00 0.175 - 0.263 0 0 0.00 101000 13195 1.88 207000 0 0.00 0.263 - 0.350 0 0 0.00 44000 6985 4.49 116000 2 0.00 0.350 - 0.438 0 0 0.00 39000 8499 5.23 48000 21 0.00 0.438 - 0.525 1000 423 0.72 12000 2809 4.87 26000 10 0.00 0.525 - 0.613 0 0 0.00 5000 1148 0.43 16000 13 0.00 0.613 - 0.700 0 0 0.00 5000 1134 1.41 7000 0 0.00 0.700 - 0.787 1000 563 5.24 3000 1323 2.13 5000 50 0.00 0.787 - 0.875 0 0 0.00 2000 585 0.44 2000 0 0.00 0.875 - 0.963 0 0 0.00 2000 138 0.01 0 0 0.00 0.963 - 1.050 0 0 0.00 0 0 0.00 1000 0 0.00 1.050 - 1.137 0 0 0.00 0 0 0.00 0 0 0.00 1.137 - 1.225 1000 194 0.28 0 0 0.00 0 0 0.00 1.225 - 1.312 0 0 0.00 0 0 0.00 0 0 0.00 1.312 - 1.400 1000 262 2.23 0 0 0.00 1000 0 0.00 1.400 - 1.488 0 0 0.00 0 0 0.00 0 0 0.00 1.488 - 1.575 1000 259 3.63 0 0 0.00 0 0 0.00 1.575 - 1.663 0 0 0.00 0 0 0.00 0 0 0.00 1.663 - 1.750 0 0 0.00 0 0 0.00 0 0 0.00 1.750 - 1.838 0 0 0.00 0 0 0.00 0 0 0.00
153 FAVPFM As-Found Output File (*.out) - (Continued) 1.838 - 1.925 1000 29 0.00 0 0 0.00 0 0 0.00 1.925 - 2.013 0 0 0.00 0 0 0.00 0 0 0.00 2.013 - 2.100 0 0 0.00 0 0 0.00 0 0 0.00 2.100 - 2.188 1000 47 0.08 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 8000 1777 12.18 849000 53639 21.81 1692000 96 0.00
=====================================================================
- PLATE FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF INITIATION *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPI>0 CPI flaws CPI>0 CPI flaws CPI>0 CPI
=====================================================================
0.000 - 0.088 7000 0 0.00 450000 68 0.00 828000 0 0.00 0.088 - 0.175 14000 0 0.00 200000 1105 0.01 420000 0 0.00 0.175 - 0.263 7000 2663 5.26 95000 2142 0.09 193000 0 0.00 0.263 - 0.350 8000 2782 4.97 62000 3891 0.34 79000 0 0.00 0.350 - 0.438 12000 3509 12.41 23000 1567 0.40 55000 0 0.00 0.438 - 0.525 17000 3530 4.00 18000 1106 0.14 33000 0 0.00 0.525 - 0.613 8000 1623 6.52 6000 788 0.28 10000 0 0.00 0.613 - 0.700 7000 1074 0.16 5000 16 0.00 6000 0 0.00 0.700 - 0.787 12000 3949 24.91 2000 0 0.00 3000 0 0.00 0.787 - 0.875 11000 1823 2.06 2000 457 0.25 2000 0 0.00 0.875 - 0.963 7000 787 0.32 0 0 0.00 0 0 0.00 0.963 - 1.050 4000 109 0.07 0 0 0.00 1000 0 0.00 1.050 - 1.137 4000 517 0.83 0 0 0.00 0 0 0.00 1.137 - 1.225 9000 420 0.06 0 0 0.00 0 0 0.00 1.225 - 1.312 8000 225 0.04 0 0 0.00 0 0 0.00 1.312 - 1.400 6000 521 0.46 0 0 0.00 0 0 0.00 1.400 - 1.488 6000 182 0.14 0 0 0.00 0 0 0.00 1.488 - 1.575 6000 555 1.60 0 0 0.00 0 0 0.00 1.575 - 1.663 6000 75 0.03 0 0 0.00 0 0 0.00 1.663 - 1.750 7000 232 0.51 0 0 0.00 0 0 0.00 1.750 - 1.838 10000 113 0.14 0 0 0.00 0 0 0.00 1.838 - 1.925 10000 72 0.02 0 0 0.00 0 0 0.00 1.925 - 2.013 8000 8 0.00 0 0 0.00 0 0 0.00 2.013 - 2.100 10000 4 0.00 0 0 0.00 0 0 0.00 2.100 - 2.188 8000 17 0.00 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 212000 24790 64.51 863000 11140 1.51 1630000 0 0.00
=====================================================================
- WELD FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF FAILURE *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPF>0 CPF flaws CPF>0 CPF flaws CPF>0 CPF
=====================================================================
0.000 - 0.088 1000 0 0.00 435000 1415 0.07 839000 0 0.00 0.088 - 0.175 0 0 0.00 201000 4147 4.69 424000 0 0.00 0.175 - 0.263 0 0 0.00 101000 4784 9.43 207000 0 0.00 0.263 - 0.350 0 0 0.00 44000 1976 13.50 116000 2 0.00 0.350 - 0.438 0 0 0.00 39000 2052 5.58 48000 1 0.00 0.438 - 0.525 1000 0 0.00 12000 1258 23.33 26000 0 0.00 0.525 - 0.613 0 0 0.00 5000 736 7.49 16000 7 0.00 0.613 - 0.700 0 0 0.00 5000 557 17.37 7000 0 0.00 0.700 - 0.787 1000 0 0.00 3000 0 0.00 5000 34 0.01 0.787 - 0.875 0 0 0.00 2000 585 8.13 2000 0 0.00 0.875 - 0.963 0 0 0.00 2000 138 0.26 0 0 0.00 0.963 - 1.050 0 0 0.00 0 0 0.00 1000 0 0.00 1.050 - 1.137 0 0 0.00 0 0 0.00 0 0 0.00 1.137 - 1.225 1000 0 0.00 0 0 0.00 0 0 0.00 1.225 - 1.312 0 0 0.00 0 0 0.00 0 0 0.00 1.312 - 1.400 1000 0 0.00 0 0 0.00 1000 0 0.00 1.400 - 1.488 0 0 0.00 0 0 0.00 0 0 0.00 1.488 - 1.575 1000 0 0.00 0 0 0.00 0 0 0.00 1.575 - 1.663 0 0 0.00 0 0 0.00 0 0 0.00 1.663 - 1.750 0 0 0.00 0 0 0.00 0 0 0.00 1.750 - 1.838 0 0 0.00 0 0 0.00 0 0 0.00 1.838 - 1.925 1000 0 0.00 0 0 0.00 0 0 0.00 1.925 - 2.013 0 0 0.00 0 0 0.00 0 0 0.00 2.013 - 2.100 0 0 0.00 0 0 0.00 0 0 0.00 2.100 - 2.188 1000 0 0.00 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 8000 0 0.00 849000 17648 89.85 1692000 44 0.02
=====================================================================
- PLATE FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF FAILURE *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPF>0 CPF flaws CPF>0 CPF flaws CPF>0 CPF
=====================================================================
0.000 - 0.088 7000 0 0.00 450000 13 0.00 828000 0 0.00
154 FAVPFM As-Found Output File (*.out) - (Continued) 0.088 - 0.175 14000 0 0.00 200000 750 0.23 420000 0 0.00 0.175 - 0.263 7000 7 0.00 95000 1047 0.89 193000 0 0.00 0.263 - 0.350 8000 15 0.00 62000 1766 1.40 79000 0 0.00 0.350 - 0.438 12000 5 0.00 23000 615 0.60 55000 0 0.00 0.438 - 0.525 17000 12 0.00 18000 573 2.18 33000 0 0.00 0.525 - 0.613 8000 2 0.00 6000 521 4.82 10000 0 0.00 0.613 - 0.700 7000 6 0.00 5000 11 0.00 6000 0 0.00 0.700 - 0.787 12000 19 0.00 2000 0 0.00 3000 0 0.00 0.787 - 0.875 11000 28 0.00 2000 1 0.00 2000 0 0.00 0.875 - 0.963 7000 19 0.00 0 0 0.00 0 0 0.00 0.963 - 1.050 4000 1 0.00 0 0 0.00 1000 0 0.00 1.050 - 1.137 4000 28 0.00 0 0 0.00 0 0 0.00 1.137 - 1.225 9000 13 0.00 0 0 0.00 0 0 0.00 1.225 - 1.312 8000 12 0.00 0 0 0.00 0 0 0.00 1.312 - 1.400 6000 18 0.00 0 0 0.00 0 0 0.00 1.400 - 1.488 6000 5 0.00 0 0 0.00 0 0 0.00 1.488 - 1.575 6000 20 0.00 0 0 0.00 0 0 0.00 1.575 - 1.663 6000 1 0.00 0 0 0.00 0 0 0.00 1.663 - 1.750 7000 20 0.01 0 0 0.00 0 0 0.00 1.750 - 1.838 10000 0 0.00 0 0 0.00 0 0 0.00 1.838 - 1.925 10000 2 0.00 0 0 0.00 0 0 0.00 1.925 - 2.013 8000 0 0.00 0 0 0.00 0 0 0.00 2.013 - 2.100 10000 0 0.00 0 0 0.00 0 0 0.00 2.100 - 2.188 8000 0 0.00 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 212000 233 0.01 863000 5297 10.12 1630000 0 0.00
=====================================================================
===================================
- TRANSIENT TIME DISTRIBUTION REPORT *
- for transient sequence 1 *
===================================
TIME TIME % of CDF of % of CDF of STEP (min) total total total total CDCPI CDCPI CDCPF CDCPF
===================================
8 7.0 0.0002 0.0002 0.0000 0.0000 9 8.0 0.0015 0.0017 0.0000 0.0000 10 9.0 0.0217 0.0235 0.0009 0.0009 11 10.0 0.3590 0.3824 0.0077 0.0086 12 11.0 3.6030 3.9855 2.0058 2.0144 13 12.0 13.2302 17.2157 13.8663 15.8807 14 13.0 34.3807 51.5964 46.6605 62.5412 15 14.0 41.4308 93.0272 27.4302 89.9714 16 15.0 6.9072 99.9345 9.8435 99.8149 17 16.0 0.0652 99.9997 0.1774 99.9922 18 17.0 0.0003 100.0000 0.0073 99.9996 20 19.0 0.0000 100.0000 0.0004 100.0000
- PROBABILITY DISTRIBUTION FUNCTION (HISTOGRAM) *
- FOR THE INITIATING DRIVING FORCES *
- FOR TRANSIENT SEQUENCE 1 *
===================================
RELATIVE CUMULATIVE KI(ksi-in^1/2) DENSITY DISTRIBUTION (bin midpoint) (%) (%)
===================================
21.00 0.0295 0.0295 23.00 0.3675 0.3970 25.00 1.3835 1.7805 27.00 3.6386 5.4191 29.00 2.7560 8.1751 31.00 4.7607 12.9358 33.00 4.8909 17.8267 35.00 7.7398 25.5665 37.00 6.3728 31.9393 39.00 7.7726 39.7119 41.00 6.4099 46.1219 43.00 4.8427 50.9646 45.00 2.9321 53.8967 47.00 4.6098 58.5065 49.00 5.5919 64.0984 51.00 4.7531 68.8514 53.00 3.0294 71.8809 55.00 2.7407 74.6216 57.00 1.7695 76.3911 59.00 2.3798 78.7709 61.00 0.7404 79.5114 63.00 2.4553 81.9666 65.00 0.0317 81.9983 67.00 2.0911 84.0894 69.00 1.5814 85.6709 71.00 1.8199 87.4907 75.00 0.2592 87.7499 83.00 1.7761 89.5260 85.00 1.3988 90.9248 87.00 0.2537 91.1785 89.00 0.6999 91.8785
155 FAVPFM As-Found Output File (*.out) - (Continued) 91.00 0.5654 92.4439 95.00 1.4021 93.8460 97.00 0.2209 94.0669 99.00 0.2078 94.2747 103.00 4.6174 98.8921 105.00 0.0536 98.9457 107.00 0.0339 98.9796 109.00 0.0306 99.0102 113.00 0.0350 99.0452 125.00 0.4320 99.4772 127.00 0.0022 99.4794 129.00 0.2373 99.7167 135.00 0.2833 100.0000
===================================
RELATIVE CUMULATIVE KI(ksi-in^1/2) DENSITY DISTRIBUTION (bin midpoint) (%) (%)
===================================
========================================================================================
FAILURE MECHANISM REPORT FOR TRANSIENT SEQUENCE 1
========================================================================================
NUMBER OF % OF TOTAL FAILURE FAILURE TRIALS TRIALS CLEAVAGE PROPAGATION TO PLASTIC INSTABILITY 0 0.00 CLEAVAGE PROPAGATION EXCEEDS WALL DEPTH FAILURE CRITERIA 1742999 100.00
- PFM RESULTS FOR TRANSIENT NUMBER 2 **
- NUMBER OF COMPLETED TRIALS = 1000 **
MEAN VALUE OF CPI = 2.183E-01 MEAN VALUE OF CPF = 1.858E-01
- RPV BELTLINE MAJOR REGION REPORT *
- BY PARENT SUBREGION *
========================================================================================
l---Initiation---l l----Cleavage----l l------Ductile-----l MAJOR RTndt % OF SIMULATED # of FLAWS % of # of FLAWS % of # of FLAWS % of REGION (MAX) FLAWS FLAWS CPI > 0 CPI CPF > 0 CPF CPF > 0 CPF
========================================================================================
1 241.6 3.24 170000 1395 0.76 1394 0.89 0 0.00 2 254.9 2.66 140000 3406 0.69 3406 0.81 0 0.00 3 254.9 2.53 133000 2195 1.50 2194 1.75 0 0.00 4 255.5 4.26 224000 4423 8.86 4423 6.76 0 0.00 5 242.1 4.23 222000 2220 0.31 2220 0.36 0 0.00 6 255.5 4.61 242000 3150 30.64 3150 22.55 0 0.00 7 260.7 26.99 1418000 1085 2.95 1085 2.46 0 0.00 8 179.8 6.62 348000 2046 1.39 2046 1.65 0 0.00 9 152.9 6.95 365000 784 0.24 784 0.28 0 0.00 10 89.5 7.50 394000 0 0.00 0 0.00 0 0.00 11 217.3 10.16 534000 10370 22.73 10368 26.97 0 0.00 12 194.3 10.03 527000 6036 3.32 6034 3.94 0 0.00 13 215.3 10.22 537000 13070 26.62 13066 31.57 0 0.00
========================================================================================
TOTALS 100.00 5254000 50180 100.00 50170 100.00 0 0.00
========================================================================================
NOTE: MEAN VALUE OF RTNDT AT CRACK TIP= 162.84
=========================================================
=========================================================
Flaw Flaw Depth Aspect Sub Crack tip Flaw average % of % of ID# KIND (inch) ratio Region (inch) ORNT RTNDT CPImean CPI CPFmean CPF 295 1 1.575 99.000 6 1.575 circf 180.81 0.659E-01 24.01 0.407E-01 17.57 4100 1 1.837 99.000 13 1.837 circf 182.24 0.217E-01 7.89 0.217E-01 9.37 2760 1 1.750 99.000 11 1.750 circf 183.96 0.210E-01 7.63 0.210E-01 9.05 FAVPFM As-Found Output File (*.out) - (Continued) 2174 1 1.400 6.000 4 1.400 circf 183.30 0.186E-01 6.78 0.101E-01 4.38 4685 1 2.188 6.000 6 2.188 circf 171.74 0.179E-01 6.53 0.113E-01 4.87 4223 1 1.575 99.000 11 1.575 circf 185.56 0.172E-01 6.26 0.172E-01 7.43 3113 1 1.575 99.000 13 1.575 circf 184.31 0.159E-01 5.80 0.159E-01 6.88 721 1 0.787 6.000 7 0.787 circf 200.77 0.770E-02 2.80 0.541E-02 2.34 13 1 2.188 6.000 13 2.188 circf 178.53 0.461E-02 1.68 0.461E-02 1.99 1297 1 1.925 6.000 11 1.925 circf 182.00 0.452E-02 1.64 0.452E-02 1.95 5167 1 1.750 6.000 11 1.750 circf 184.04 0.411E-02 1.50 0.411E-02 1.78 1249 1 1.925 6.000 13 1.925 circf 181.31 0.407E-02 1.48 0.407E-02 1.76
156 FAVPFM As-Found Output File (*.out) - (Continued) 217 1 1.750 6.000 11 1.750 circf 184.03 0.405E-02 1.47 0.405E-02 1.75 986 1 1.925 6.000 13 1.925 circf 181.06 0.398E-02 1.45 0.398E-02 1.72 800 1 0.787 99.000 11 0.787 circf 193.09 0.363E-02 1.32 0.363E-02 1.57 4340 1 0.787 99.000 11 0.787 circf 192.83 0.357E-02 1.30 0.357E-02 1.54 143 1 0.787 99.000 13 0.787 circf 192.01 0.342E-02 1.25 0.342E-02 1.48 4618 1 0.787 99.000 13 0.787 circf 191.91 0.337E-02 1.23 0.337E-02 1.45 3074 2 0.700 4.424 3 0.491 axial 193.83 0.337E-02 1.23 0.332E-02 1.43 2128 1 1.575 6.000 11 1.575 circf 185.80 0.333E-02 1.21 0.333E-02 1.44 1443 1 1.663 6.000 13 1.663 circf 183.68 0.317E-02 1.15 0.317E-02 1.37 3052 1 1.488 6.000 13 1.488 circf 185.19 0.265E-02 0.96 0.265E-02 1.14 3282 1 1.837 99.000 8 1.837 circf 145.06 0.237E-02 0.86 0.237E-02 1.02 1981 1 1.400 6.000 13 1.400 circf 186.40 0.235E-02 0.86 0.235E-02 1.02
=========================================================
- Allocation of Risk by Flaw for Transient 2 - sorted by % of CPF *
=========================================================
Flaw Flaw Depth Aspect Sub Crack tip Flaw average % of % of ID# KIND (inch) ratio Region (inch) ORNT RTNDT CPImean CPI CPFmean CPF 295 1 1.575 99.000 6 1.575 circf 180.81 0.659E-01 24.01 0.407E-01 17.57 4100 1 1.837 99.000 13 1.837 circf 182.24 0.217E-01 7.89 0.217E-01 9.37 2760 1 1.750 99.000 11 1.750 circf 183.96 0.210E-01 7.63 0.210E-01 9.05 4223 1 1.575 99.000 11 1.575 circf 185.56 0.172E-01 6.26 0.172E-01 7.43 3113 1 1.575 99.000 13 1.575 circf 184.31 0.159E-01 5.80 0.159E-01 6.88 4685 1 2.188 6.000 6 2.188 circf 171.74 0.179E-01 6.53 0.113E-01 4.87 2174 1 1.400 6.000 4 1.400 circf 183.30 0.186E-01 6.78 0.101E-01 4.38 721 1 0.787 6.000 7 0.787 circf 200.77 0.770E-02 2.80 0.541E-02 2.34 13 1 2.188 6.000 13 2.188 circf 178.53 0.461E-02 1.68 0.461E-02 1.99 1297 1 1.925 6.000 11 1.925 circf 182.00 0.452E-02 1.64 0.452E-02 1.95 5167 1 1.750 6.000 11 1.750 circf 184.04 0.411E-02 1.50 0.411E-02 1.78 1249 1 1.925 6.000 13 1.925 circf 181.31 0.407E-02 1.48 0.407E-02 1.76 217 1 1.750 6.000 11 1.750 circf 184.03 0.405E-02 1.47 0.405E-02 1.75 986 1 1.925 6.000 13 1.925 circf 181.06 0.398E-02 1.45 0.398E-02 1.72 800 1 0.787 99.000 11 0.787 circf 193.09 0.363E-02 1.32 0.363E-02 1.57 4340 1 0.787 99.000 11 0.787 circf 192.83 0.357E-02 1.30 0.357E-02 1.54 143 1 0.787 99.000 13 0.787 circf 192.01 0.342E-02 1.25 0.342E-02 1.48 4618 1 0.787 99.000 13 0.787 circf 191.91 0.337E-02 1.23 0.337E-02 1.45 2128 1 1.575 6.000 11 1.575 circf 185.80 0.333E-02 1.21 0.333E-02 1.44 3074 2 0.700 4.424 3 0.491 axial 193.83 0.337E-02 1.23 0.332E-02 1.43 1443 1 1.663 6.000 13 1.663 circf 183.68 0.317E-02 1.15 0.317E-02 1.37 3052 1 1.488 6.000 13 1.488 circf 185.19 0.265E-02 0.96 0.265E-02 1.14 3282 1 1.837 99.000 8 1.837 circf 145.06 0.237E-02 0.86 0.237E-02 1.02 1981 1 1.400 6.000 13 1.400 circf 186.40 0.235E-02 0.86 0.235E-02 1.02
- FLAW DISTRIBUTION BY MATERIAL AND CATEGORY *
- BY PARENT SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
FLAW CATEGORY 1(int) 8000 3146 40.45 3146 29.42 FLAW CATEGORY 2(int) 849000 13271 5.07 13269 5.95 FLAW CATEGORY 3(int) 1692000 1457 0.19 1457 0.22
======================================
TOTALS 2549000 17874 45.70 17872 35.59
======================================
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
FLAW CATEGORY 1(int) 212000 30083 54.20 30075 64.30 FLAW CATEGORY 2(int) 863000 2223 0.09 2223 0.11 FLAW CATEGORY 3(int) 1630000 0 0.00 0 0.00
======================================
TOTALS 2705000 32306 54.30 32298 64.41
======================================
- FLAW DISTRIBUTION BY MATERIAL, CATEGORY, & ORIENTATION *
- BY PARENT SUBREGION *
======================================
WELD MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 0 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 367000 13156 5.07 13154 5.95 AXIAL FLAW CATEGORY 3 758000 1456 0.19 1456 0.22
======================================
AXIAL SUBTOTALS 1125000 14612 5.26 14610 6.17
157 FAVPFM As-Found Output File (*.out) - (Continued)
======================================
CIRC. FLAW CATEGORY 1 8000 3146 40.45 3146 29.42 CIRC. FLAW CATEGORY 2 482000 115 0.00 115 0.00 CIRC. FLAW CATEGORY 3 934000 1 0.00 1 0.00
======================================
CIRC. SUBTOTALS 1424000 3262 40.45 3262 29.42
======================================
WELD TOTALS 2549000 17874 45.70 17872 35.59
======================================
======================================
PLATE MATERIAL
======================================
number of number % of number % of simulated with total with total flaws CPI>0 CPI CPF>0 CPF
======================================
AXIAL FLAW CATEGORY 1 0 0 0.00 0 0.00 AXIAL FLAW CATEGORY 2 415000 2223 0.09 2223 0.11 AXIAL FLAW CATEGORY 3 832000 0 0.00 0 0.00
======================================
AXIAL SUBTOTALS 1247000 2223 0.09 2223 0.11
======================================
CIRC. FLAW CATEGORY 1 212000 30083 54.20 30075 64.30 CIRC. FLAW CATEGORY 2 448000 0 0.00 0 0.00 CIRC. FLAW CATEGORY 3 798000 0 0.00 0 0.00
======================================
CIRC. SUBTOTALS 1458000 30083 54.20 60150 64.30
======================================
PLATE TOTALS 2705000 32306 54.30 62373 64.41
======================================
- WELD FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF INITIATION *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPI>0 CPI flaws CPI>0 CPI flaws CPI>0 CPI
=====================================================================
0.000 - 0.088 1000 0 0.00 435000 0 0.00 839000 0 0.00 0.088 - 0.175 0 0 0.00 201000 411 0.00 424000 0 0.00 0.175 - 0.263 0 0 0.00 101000 2976 0.04 207000 12 0.00 0.263 - 0.350 0 0 0.00 44000 1654 0.12 116000 241 0.00 0.350 - 0.438 0 0 0.00 39000 2796 0.27 48000 306 0.00 0.438 - 0.525 1000 229 0.01 12000 1693 0.96 26000 41 0.00 0.525 - 0.613 0 0 0.00 5000 1074 0.61 16000 283 0.01 0.613 - 0.700 0 0 0.00 5000 1029 1.35 7000 20 0.00 0.700 - 0.787 1000 630 2.80 3000 110 0.00 5000 466 0.17 0.787 - 0.875 0 0 0.00 2000 815 0.80 2000 0 0.00 0.875 - 0.963 0 0 0.00 2000 713 0.92 0 0 0.00 0.963 - 1.050 0 0 0.00 0 0 0.00 1000 72 0.00 1.050 - 1.137 0 0 0.00 0 0 0.00 0 0 0.00 1.137 - 1.225 1000 326 0.17 0 0 0.00 0 0 0.00 1.225 - 1.312 0 0 0.00 0 0 0.00 0 0 0.00 1.312 - 1.400 1000 541 6.78 0 0 0.00 1000 16 0.00 1.400 - 1.488 0 0 0.00 0 0 0.00 0 0 0.00 1.488 - 1.575 1000 619 24.01 0 0 0.00 0 0 0.00 1.575 - 1.663 0 0 0.00 0 0 0.00 0 0 0.00 1.663 - 1.750 0 0 0.00 0 0 0.00 0 0 0.00 1.750 - 1.838 0 0 0.00 0 0 0.00 0 0 0.00 1.838 - 1.925 1000 339 0.15 0 0 0.00 0 0 0.00 1.925 - 2.013 0 0 0.00 0 0 0.00 0 0 0.00 2.013 - 2.100 0 0 0.00 0 0 0.00 0 0 0.00 2.100 - 2.188 1000 462 6.53 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 8000 3146 40.45 849000 13271 5.07 1692000 1457 0.19
=====================================================================
- PLATE FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF INITIATION *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPI>0 CPI flaws CPI>0 CPI flaws CPI>0 CPI
=====================================================================
0.000 - 0.088 7000 0 0.00 450000 0 0.00 828000 0 0.00 0.088 - 0.175 14000 0 0.00 200000 0 0.00 420000 0 0.00 0.175 - 0.263 7000 999 0.04 95000 57 0.00 193000 0 0.00 0.263 - 0.350 8000 1453 0.07 62000 425 0.00 79000 0 0.00 0.350 - 0.438 12000 1816 0.31 23000 485 0.00 55000 0 0.00 0.438 - 0.525 17000 1100 0.09 18000 638 0.01 33000 0 0.00 0.525 - 0.613 8000 720 0.58 6000 610 0.08 10000 0 0.00 0.613 - 0.700 7000 159 0.00 5000 8 0.00 6000 0 0.00 0.700 - 0.787 12000 4264 6.47 2000 0 0.00 3000 0 0.00 0.787 - 0.875 11000 1937 0.62 2000 0 0.00 2000 0 0.00 0.875 - 0.963 7000 637 0.09 0 0 0.00 0 0 0.00
158 FAVPFM As-Found Output File (*.out) - (Continued) 0.963 - 1.050 4000 232 0.05 0 0 0.00 1000 0 0.00 1.050 - 1.137 4000 879 0.65 0 0 0.00 0 0 0.00 1.137 - 1.225 9000 758 0.02 0 0 0.00 0 0 0.00 1.225 - 1.312 8000 605 0.02 0 0 0.00 0 0 0.00 1.312 - 1.400 6000 1878 2.34 0 0 0.00 0 0 0.00 1.400 - 1.488 6000 807 0.99 0 0 0.00 0 0 0.00 1.488 - 1.575 6000 2439 14.06 0 0 0.00 0 0 0.00 1.575 - 1.663 6000 645 1.26 0 0 0.00 0 0 0.00 1.663 - 1.750 7000 1816 10.70 0 0 0.00 0 0 0.00 1.750 - 1.838 10000 1483 8.80 0 0 0.00 0 0 0.00 1.838 - 1.925 10000 1995 4.83 0 0 0.00 0 0 0.00 1.925 - 2.013 8000 1060 0.09 0 0 0.00 0 0 0.00 2.013 - 2.100 10000 1212 0.09 0 0 0.00 0 0 0.00 2.100 - 2.188 8000 1189 2.04 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 212000 30083 54.20 863000 2223 0.09 1630000 0 0.00
=====================================================================
- WELD FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF FAILURE *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPF>0 CPF flaws CPF>0 CPF flaws CPF>0 CPF
=====================================================================
0.000 - 0.088 1000 0 0.00 435000 0 0.00 839000 0 0.00 0.088 - 0.175 0 0 0.00 201000 410 0.00 424000 0 0.00 0.175 - 0.263 0 0 0.00 101000 2976 0.04 207000 12 0.00 0.263 - 0.350 0 0 0.00 44000 1654 0.14 116000 241 0.00 0.350 - 0.438 0 0 0.00 39000 2795 0.31 48000 306 0.00 0.438 - 0.525 1000 229 0.01 12000 1693 1.13 26000 41 0.00 0.525 - 0.613 0 0 0.00 5000 1074 0.72 16000 283 0.02 0.613 - 0.700 0 0 0.00 5000 1029 1.58 7000 20 0.00 0.700 - 0.787 1000 630 2.34 3000 110 0.00 5000 466 0.20 0.787 - 0.875 0 0 0.00 2000 815 0.94 2000 0 0.00 0.875 - 0.963 0 0 0.00 2000 713 1.09 0 0 0.00 0.963 - 1.050 0 0 0.00 0 0 0.00 1000 72 0.00 1.050 - 1.137 0 0 0.00 0 0 0.00 0 0 0.00 1.137 - 1.225 1000 326 0.13 0 0 0.00 0 0 0.00 1.225 - 1.312 0 0 0.00 0 0 0.00 0 0 0.00 1.312 - 1.400 1000 541 4.38 0 0 0.00 1000 16 0.00 1.400 - 1.488 0 0 0.00 0 0 0.00 0 0 0.00 1.488 - 1.575 1000 619 17.57 0 0 0.00 0 0 0.00 1.575 - 1.663 0 0 0.00 0 0 0.00 0 0 0.00 1.663 - 1.750 0 0 0.00 0 0 0.00 0 0 0.00 1.750 - 1.838 0 0 0.00 0 0 0.00 0 0 0.00 1.838 - 1.925 1000 339 0.13 0 0 0.00 0 0 0.00 1.925 - 2.013 0 0 0.00 0 0 0.00 0 0 0.00 2.013 - 2.100 0 0 0.00 0 0 0.00 0 0 0.00 2.100 - 2.188 1000 462 4.87 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 8000 3146 29.42 849000 13269 5.95 1692000 1457 0.22
=====================================================================
- PLATE FLAW-SIZE DISTRIBUTION REPORT *
- FOR CONDITIONAL PROBABILITY OF FAILURE *
=====================================================================
flaw depth simulated # % of simulated # % of simulated # % of interval catgy 1 with total catgy 2 with total catgy 3 with total (in) flaws CPF>0 CPF flaws CPF>0 CPF flaws CPF>0 CPF
=====================================================================
0.000 - 0.088 7000 0 0.00 450000 0 0.00 828000 0 0.00 0.088 - 0.175 14000 0 0.00 200000 0 0.00 420000 0 0.00 0.175 - 0.263 7000 998 0.04 95000 57 0.00 193000 0 0.00 0.263 - 0.350 8000 1453 0.08 62000 425 0.00 79000 0 0.00 0.350 - 0.438 12000 1816 0.37 23000 485 0.00 55000 0 0.00 0.438 - 0.525 17000 1100 0.11 18000 638 0.01 33000 0 0.00 0.525 - 0.613 8000 720 0.69 6000 610 0.09 10000 0 0.00 0.613 - 0.700 7000 159 0.00 5000 8 0.00 6000 0 0.00 0.700 - 0.787 12000 4264 7.67 2000 0 0.00 3000 0 0.00 0.787 - 0.875 11000 1935 0.74 2000 0 0.00 2000 0 0.00 0.875 - 0.963 7000 637 0.11 0 0 0.00 0 0 0.00 FAVPFM As-Found Output File (*.out) - (Continued) 0.963 - 1.050 4000 232 0.06 0 0 0.00 1000 0 0.00 1.050 - 1.137 4000 879 0.77 0 0 0.00 0 0 0.00 1.137 - 1.225 9000 757 0.02 0 0 0.00 0 0 0.00 1.225 - 1.312 8000 604 0.02 0 0 0.00 0 0 0.00 1.312 - 1.400 6000 1878 2.78 0 0 0.00 0 0 0.00 1.400 - 1.488 6000 807 1.18 0 0 0.00 0 0 0.00 1.488 - 1.575 6000 2439 16.68 0 0 0.00 0 0 0.00 1.575 - 1.663 6000 645 1.49 0 0 0.00 0 0 0.00 1.663 - 1.750 7000 1816 12.69 0 0 0.00 0 0 0.00 1.750 - 1.838 10000 1482 10.44 0 0 0.00 0 0 0.00 1.838 - 1.925 10000 1995 5.73 0 0 0.00 0 0 0.00 1.925 - 2.013 8000 1060 0.11 0 0 0.00 0 0 0.00 2.013 - 2.100 10000 1210 0.10 0 0 0.00 0 0 0.00 2.100 - 2.188 8000 1189 2.42 0 0 0.00 0 0 0.00 2.188 - 2.275 0 0 0.00 0 0 0.00 0 0 0.00
=====================================================================
TOTALS 212000 30075 64.30 863000 2223 0.11 1630000 0 0.00
=====================================================================
159 FAVPFM As-Found Output File (*.out) - (Continued)
===================================
- TRANSIENT TIME DISTRIBUTION REPORT *
- for transient sequence 2 *
===================================
TIME TIME % of CDF of % of CDF of STEP (min) total total total total CDCPI CDCPI CDCPF CDCPF
===================================
38 37.0 0.0000 0.0000 0.0000 0.0000 39 38.0 0.0000 0.0000 0.0000 0.0000 40 39.0 0.0000 0.0000 0.0000 0.0000 41 40.0 0.0000 0.0000 0.0000 0.0000 42 41.0 0.0000 0.0000 0.0000 0.0000 43 42.0 0.0000 0.0000 0.0000 0.0000 44 43.0 0.0000 0.0000 0.0000 0.0000 45 44.0 0.0000 0.0000 0.0000 0.0000 46 45.0 0.0000 0.0001 0.0000 0.0000 47 46.0 0.0000 0.0001 0.0000 0.0000 48 47.0 0.0000 0.0002 0.0000 0.0000 49 48.0 0.0001 0.0002 0.0000 0.0000 50 49.0 0.0002 0.0004 0.0000 0.0000 51 50.0 0.0003 0.0007 0.0000 0.0000 52 51.0 0.0005 0.0012 0.0000 0.0000 53 52.0 0.0009 0.0021 0.0000 0.0000 54 53.0 0.0014 0.0034 0.0000 0.0001 55 54.0 0.0020 0.0054 0.0000 0.0001 56 55.0 0.0028 0.0082 0.0001 0.0002 57 56.0 0.0033 0.0115 0.0001 0.0003 58 57.0 0.0045 0.0160 0.0002 0.0004 59 58.0 0.0006 0.0166 0.0002 0.0006 60 59.0 0.0000 0.0166 0.0000 0.0006 61 60.0 0.0000 0.0166 0.0000 0.0006 62 61.0 0.0000 0.0166 0.0000 0.0006 65 64.0 0.0000 0.0166 0.0000 0.0006 66 65.0 0.0000 0.0166 0.0000 0.0006 70 69.0 0.0000 0.0166 0.0000 0.0006 72 71.0 0.0000 0.0166 0.0000 0.0006 111 110.0 0.0514 0.0681 0.0581 0.0588 112 111.0 0.4248 0.4929 0.4894 0.5482 113 112.0 22.3137 22.8065 22.2354 22.7835 114 113.0 44.7522 67.5588 41.4736 64.2571 115 114.0 29.1760 96.7348 32.1146 96.3717 116 115.0 3.2645 99.9993 3.6274 99.9991 120 119.0 0.0007 100.0000 0.0009 100.0000
- PROBABILITY DISTRIBUTION FUNCTION (HISTOGRAM) *
- FOR THE INITIATING DRIVING FORCES *
- FOR TRANSIENT SEQUENCE 2 *
===================================
RELATIVE CUMULATIVE KI(ksi-in^1/2) DENSITY DISTRIBUTION (bin midpoint) (%) (%)
===================================
21.00 0.6717 0.6717 23.00 2.1945 2.8663 25.00 5.2661 8.1324 27.00 7.8932 16.0255 29.00 4.7379 20.7634 31.00 9.6891 30.4525 33.00 8.4732 38.9257 35.00 4.2316 43.1573 37.00 9.0193 52.1766 39.00 3.3965 55.5731 41.00 4.4489 60.0219 43.00 2.9261 62.9480 45.00 1.7520 64.7000 47.00 9.7249 74.4250 49.00 3.0098 77.4347 51.00 2.8124 80.2472 53.00 4.3711 84.6183 55.00 0.1056 84.7239 57.00 5.8362 90.5601 59.00 1.5647 92.1248 63.00 2.4935 94.6183 65.00 1.0983 95.7166 67.00 1.2478 96.9643 69.00 1.8019 98.7662 73.00 1.2338 100.0000
===================================
RELATIVE CUMULATIVE KI(ksi-in^1/2) DENSITY DISTRIBUTION (bin midpoint) (%) (%)
===================================
========================================================================================
FAILURE MECHANISM REPORT FOR TRANSIENT SEQUENCE 2
========================================================================================
NUMBER OF % OF TOTAL FAILURE FAILURE TRIALS TRIALS
160 FAVPFM As-Found Output File (*.out) - (Continued)
CLEAVAGE PROPAGATION TO PLASTIC INSTABILITY 12951118 89.10 CLEAVAGE PROPAGATION EXCEEDS WALL DEPTH FAILURE CRITERIA 1584576 10.90
- MULTIPLE FLAW STATISTICS
- NUMBER OF OCCASIONS WHEN SIMULATED RPV HAD X FLAWS % OF X FLAWS % OF X FLAWS WITH CPI > 0 TOTAL CPI WITH CPF > 0 TOTAL CPF 1 1 0.05 14 0.70 2 0 0.00 11 0.55 3 0 0.00 19 0.95 4 2 0.10 16 0.80 5 4 0.20 21 1.05 6 7 0.35 25 1.25 7 7 0.35 23 1.15 8 9 0.45 28 1.40 9 5 0.25 24 1.20 10 10 0.50 39 1.96 11 7 0.35 35 1.76 12 8 0.40 30 1.51 13 10 0.50 43 2.16 14 14 0.70 40 2.01 15 15 0.75 42 2.11 16 10 0.50 36 1.81 17 18 0.90 47 2.36 18 16 0.80 43 2.16 19 16 0.80 43 2.16 20 11 0.55 35 1.76 21 13 0.65 33 1.66 22 12 0.60 33 1.66 23 17 0.85 37 1.86 24 14 0.70 38 1.91 25 16 0.80 34 1.71 26 20 1.00 36 1.81 27 13 0.65 28 1.40 28 21 1.05 30 1.51 29 17 0.85 36 1.81 30 26 1.30 24 1.20 31 25 1.25 44 2.21 32 20 1.00 33 1.66 33 28 1.40 43 2.16 34 21 1.05 30 1.51 35 21 1.05 21 1.05 36 31 1.55 39 1.96 37 26 1.30 30 1.51 38 19 0.95 23 1.15 39 21 1.05 24 1.20 40 24 1.20 24 1.20 41 25 1.25 25 1.25 42 22 1.10 22 1.10 43 21 1.05 21 1.05 44 30 1.50 31 1.56 45 20 1.00 17 0.85 46 24 1.20 29 1.46 47 24 1.20 25 1.25 48 16 0.80 17 0.85 49 21 1.05 15 0.75 50 17 0.85 15 0.75 51 21 1.05 17 0.85 52 23 1.15 21 1.05 53 20 1.00 16 0.80 54 26 1.30 20 1.00 55 16 0.80 17 0.85 56 14 0.70 12 0.60 57 34 1.70 27 1.35 58 16 0.80 17 0.85 59 25 1.25 23 1.15 60 21 1.05 14 0.70 61 19 0.95 11 0.55 62 21 1.05 10 0.50 63 20 1.00 15 0.75 64 20 1.00 16 0.80 65 27 1.35 11 0.55 66 26 1.30 13 0.65 67 15 0.75 7 0.35 68 22 1.10 12 0.60 69 15 0.75 9 0.45 70 22 1.10 13 0.65 71 12 0.60 5 0.25 72 24 1.20 12 0.60 73 21 1.05 13 0.65 74 15 0.75 11 0.55 75 19 0.95 13 0.65 76 23 1.15 14 0.70 77 11 0.55 6 0.30 78 17 0.85 8 0.40 79 19 0.95 10 0.50 80 13 0.65 9 0.45
161 FAVPFM As-Found Output File (*.out) - (Continued) 81 16 0.80 11 0.55 82 12 0.60 8 0.40 83 10 0.50 3 0.15 84 16 0.80 5 0.25 85 16 0.80 9 0.45 86 10 0.50 3 0.15 87 6 0.30 3 0.15 88 12 0.60 7 0.35 89 12 0.60 4 0.20 90 10 0.50 6 0.30 91 14 0.70 3 0.15 92 15 0.75 4 0.20 93 7 0.35 2 0.10 94 11 0.55 4 0.20 95 5 0.25 2 0.10 96 4 0.20 1 0.05 97 4 0.20 3 0.15 98 9 0.45 3 0.15 99 8 0.40 4 0.20 100 9 0.45 4 0.20 101 6 0.30 3 0.15 102 9 0.45 5 0.25 103 7 0.35 2 0.10 104 6 0.30 1 0.05 105 11 0.55 2 0.10 106 7 0.35 0 0.00 107 8 0.40 1 0.05 108 6 0.30 3 0.15 109 6 0.30 0 0.00 110 5 0.25 1 0.05 111 6 0.30 0 0.00 112 5 0.25 2 0.10 113 9 0.45 1 0.05 114 9 0.45 1 0.05 115 6 0.30 1 0.05 116 10 0.50 1 0.05 117 5 0.25 2 0.10 118 2 0.10 0 0.00 119 8 0.40 0 0.00 120 6 0.30 0 0.00 121 5 0.25 1 0.05 122 5 0.25 0 0.00 123 3 0.15 0 0.00 124 8 0.40 1 0.05 125 7 0.35 0 0.00 126 4 0.20 0 0.00 127 3 0.15 0 0.00 128 5 0.25 0 0.00 129 3 0.15 0 0.00 130 6 0.30 0 0.00 131 7 0.35 0 0.00 132 5 0.25 0 0.00 133 3 0.15 0 0.00 134 5 0.25 0 0.00 135 1 0.05 0 0.00 136 5 0.25 1 0.05 137 7 0.35 0 0.00 138 8 0.40 0 0.00 139 1 0.05 0 0.00 140 2 0.10 0 0.00 141 3 0.15 0 0.00 142 2 0.10 0 0.00 143 4 0.20 0 0.00 144 2 0.10 0 0.00 145 3 0.15 1 0.05 146 3 0.15 0 0.00 147 5 0.25 0 0.00 148 1 0.05 0 0.00 149 2 0.10 0 0.00 150 2 0.10 0 0.00 151 2 0.10 0 0.00 152 2 0.10 1 0.05 156 4 0.20 0 0.00 157 2 0.10 0 0.00 158 1 0.05 0 0.00 159 2 0.10 0 0.00 160 3 0.15 0 0.00 161 1 0.05 0 0.00 162 4 0.20 0 0.00 163 6 0.30 0 0.00 164 2 0.10 0 0.00 165 2 0.10 0 0.00 166 2 0.10 0 0.00 167 2 0.10 0 0.00 168 1 0.05 0 0.00 169 2 0.10 0 0.00 170 1 0.05 0 0.00 171 2 0.10 0 0.00 172 1 0.05 0 0.00 173 2 0.10 0 0.00 174 4 0.20 0 0.00 176 1 0.05 0 0.00 177 2 0.10 0 0.00 178 3 0.15 0 0.00 179 4 0.20 0 0.00
162 FAVPFM As-Found Output File (*.out) - (Continued) 180 1 0.05 0 0.00 181 1 0.05 0 0.00 182 4 0.20 0 0.00 183 1 0.05 0 0.00 184 1 0.05 0 0.00 185 2 0.10 0 0.00 187 3 0.15 0 0.00 188 3 0.15 0 0.00 189 3 0.15 0 0.00 190 2 0.10 0 0.00 191 1 0.05 0 0.00 192 1 0.05 0 0.00 193 2 0.10 0 0.00 194 4 0.20 0 0.00 195 1 0.05 0 0.00 197 1 0.05 0 0.00 198 1 0.05 0 0.00 199 1 0.05 0 0.00 200 2 0.10 0 0.00 201 5 0.25 0 0.00 202 1 0.05 0 0.00 203 1 0.05 0 0.00 204 1 0.05 0 0.00 205 1 0.05 0 0.00 206 1 0.05 0 0.00 207 2 0.10 0 0.00 210 2 0.10 0 0.00 211 1 0.05 0 0.00 212 2 0.10 0 0.00 213 2 0.10 0 0.00 214 2 0.10 0 0.00 215 1 0.05 0 0.00 216 2 0.10 0 0.00 217 1 0.05 0 0.00 222 1 0.05 0 0.00 223 4 0.20 0 0.00 224 1 0.05 0 0.00 227 1 0.05 0 0.00 239 1 0.05 0 0.00 242 1 0.05 0 0.00 243 1 0.05 0 0.00 245 1 0.05 0 0.00 250 1 0.05 0 0.00 253 2 0.10 0 0.00 256 1 0.05 0 0.00 257 1 0.05 0 0.00 260 1 0.05 0 0.00 263 1 0.05 0 0.00 266 1 0.05 0 0.00 268 1 0.05 0 0.00 271 1 0.05 0 0.00 279 1 0.05 0 0.00 299 1 0.05 0 0.00 303 1 0.05 0 0.00 311 1 0.05 0 0.00 313 1 0.05 0 0.00 323 1 0.05 0 0.00 TOTALS 2000 100.00 1993 100.00 Note: One Occasion is 1 simulated RPV subjected to 1 transient DATE: 29-Jul-2020 TIME: 16:00:56
163
[1] G. J. Schuster, S. R. Doctor, S. L. Crawford and A. F. Pardini, "Characterization of Flaws in U.S.
Reactor Pressure Vessels: Density and Distribution of Flaw Indications in PVRUF, USNRC Report NUREG/CR-6471, Vol. 1," U.S. Nuclear Regulatory Commission, Washington, DC, 1998.
[2] G. J. Schuster, S. R. Doctor and P. G. Heasler, "Characterization of Flaws in U.S. Reactor Pressure Vessels: Validation of Flaw Density and Distribution in the Weld Metal of the PVRUF Vessel, USNRC Report NUREG/CR-6471, Vol. 2," U.S. Nuclear Regulatory Commission, Washington, DC, 2000.
[3] G. J. Schuster, S. R. Doctor, S. L. Crawford and A. F. Pardini, "Characterization of Flaws in U.S.
Reactor Pressure Vessels: Density and Distribution of Flaw Indications in the Shoreham Vessel, USNRC Report NUREG/CR-6471, Vol. 3," U.S. Nuclear Regulatory Commission, Washington, DC, 1999.
[4] F. A. Simonen, S. R. Doctor, G. J. Schuster and P. G. Heasler, "A Generalized Procedure for Generating Flaw-Related Inputs for the FAVOR Code, USNRC Report NUREG/CR-6817, Rev. 1,"
U.S. Nuclear Regulatory Commission, Washington, D.C., 2013.
[5] B. R. Bass, T. L. Dickson, S. B. Gorti, H. B. Klasky, R. K. Nanstad, M. A. Sokolov and P. T.
WIlliams, "ORNL Evaluation of Electrabel Safety Cases for Doel 3 / Tihange 2: Final Report (R1),"
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN, 2015.
[6] American Society of Mechanical Engineers (ASME), ASME Boiler and Pressure Vessel Code -
Section XI Rules for Inservice Inspection of Nuclear Power Plant Components, Two Park Avenue, New York, New York, USA.: ASME, 2017.
[7] American Society of Mechanical Engineers (ASME), Alternative Characterization Rules for Quasi-Laminar Flaws, ASME Boiler and Pressure Vessel Code, Case N-848,Section XI, Division 1, April 30, 2015, New York, New York: ASME, 2015.
[8] V. Lacroix, P. Dulieu and D. Couplet, "Alternative Characterization Rules for Quasi-Laminar Flaws," in Proceedings of ASME 2014 Pressure Vessels and Piping Division Conference, July 20-24, 2014, Anaheim, CA, 2014.
[9] V. Lacroix, P. Dulieu and A. S. Bogaert, "Alternative Characterization Rules for Quasi-Laminar Flaws Based on 3-D X-FEM Calculations," in Proceedings of ASME 2015 Pressure Vessels and Piping Division Conference, July 19-23, 2015, Boston, MA., 2015.
164
- 9. Appendix D - FAVOR Error Codes Error Code Description Subroutine User's Guide Section FAVLOAD Error Codes 1
Error in data Record 1 - Keyword GEOM: Data required IRAD= W= CLTH=
RD79 2.1 2
Error in data Record 2 - Keyword BASE: Data required K= C= RHO= E= ALPHA= V=
RD79 2.1 3
Error in data Record 3 - Keyword CLAD: Data required K= C= RHO= E= ALPHA= V=
RD79 2.1 4
Error in data Record 4 - Keyword SFRE: Data required T=
RD79 2.1 5
Error in data Record 5 - Keyword RESA: Data required NRAX=
RD79 2.1 6
Error in data Record 6 - Keyword RESC: Data required NRCR=
RD79 2.1 7
Error in data Record 7 - Keyword TIME: TOTAL= DT=
RD79 2.1 8
Error in data Record 7 - Input Time step too small RD79 2.1 9
Error in data Record 8 - Keyword NPRA: Data required NTRAN=
RD79 2.1 10 Error in data Record 9 - Keyword TRAN: Data required ITRAN= ISEQ=
RD79 2.1 11 Error in data Record 9 - ITRAN numbers must be in ascending order with no ommissions RD79 2.1 101 Memory allocation error - insufficient memory available for this execution CHECK_ALLOC
(-)
102 Singular matrix found in axial stress calculation SYMSL3
(-)
103 Elliptical angle out of bounds during linear interpolation of surface-breaking flaw SIFICs ANGINTBS2
(-)
104 Elliptical angle out of bounds during linear interpolation of surface-breaking flaw SIFICs ANGINTBS6
(-)
105 Elliptical angle out of bounds during linear interpolation of surface-breaking flaw SIFICs ANGINTBS10
(-)
106 Elliptical angle out of bounds during linear interpolation of surface-breaking flaw SIFICs ANGINTCL1562
(-)
107 Elliptical angle out of bounds during linear interpolation of surface-breaking flaw SIFICs ANGINTCL1566
(-)
FAVPFM Error Codes 1
Error in data Record 1 - Keyword CNT1: Data required NSIM= IGATR= WPS_OPT=
RD17 2.2 2
Error in data Record 2 - Keyword CNT2: Data required IRTNDT= TC= EFPY=
RD17 2.2 3
Error in data Record 3 - Keyword CNT3: Data required FLWSTR= USKIA= ILAYER_OPT= FAILCR=
RD17 2.2 4
Error in data Record 4 - Keyword GENR: Data required SIGFGL= SIGFLC=
RD17 2.2 5
Error in data Record 5 - Keyword SIGW: Data required WSIGCU= WSIGNI= WSIGP=
RD17 2.2 6
Error in data Record 6 - Keyword SIGP: Data required PSIGCU= PSIGNI= PSIGP=
RD17 2.2 7
Error in data Record 7 - Keyword TRAC: ITRAN= IRPV= IFLAW=
RD17 2.2 8
Error in data Record 8 - Keyword LDQA: Data required IQA= IOPT= IWELD= IKIND= XIN= XVAR= ASPE RD17 2.2 9
Error in data Record 9 - Keyword WELD: Data required NWSUB= NWMAJ=
RD17 2.2 10 Error in data Record 10 - Keyword PLAT: Data required NPSUB= NPMAJ=
RD17 2.2 11 Error in data Record 8 - Keyword LDQA: IQA must be = 0 or 1 RD17 2.2 12 Load file not generated by FAVLoad 02.3: Rerun load module RDDET
(-)
13 INVALID FLAW ORIENTATION PROP
(-)
14 ISQ? CARD NEEDS FOUR VARS - SEE USER GUIDE RD17 2.2 15 DTRF Record: ITRAN ISEQ mismatch RD17 2.2 16 DTRF Record: ITRAN greater than MTRAN RD17 2.2 17 SURFACE-BREAKING FLAW FILE NOT VERSION 04.1 RDSURF
(-)
18 ERROR READING SURFACE-BREAKING FLAW DATA RDSURF
(-)
19 EMBEDDED-FLAW WELD FILE NOT VERSION 04.1 RDWELD
(-)
20 ERROR READING WELD EMB. FLAW DATA RDWELD
(-)
21 EMBEDDED-FLAW PLATE FILE NOT VERSION 04.1 RDPLAT
(-)
22 ERROR READING PLATE EMB. FLAW DATA RDPLAT
(-)
23 INVALID ICORR(NSBR)
EWO1998
(-)
24 ERROR IN WELD SUBREGION DEFINITIONS RD17 2.2 25 ERROR IN PLATE SUBREGION DEFINITIONS:NSUBR(I,1)/=NSUBR(I,2)
RD17 2.2 101 Memory allocation error - insufficient memory available for this execution CHECK_ALLOC
(-)
FAVPost Error Codes 1
PFM input files not generated by version 02.3: Rerun with FAVPFM 02.3 Main
(-)
2 Inconsistent input data. Incorrect number of transients specified Main
(-)
3 Inconsistent input data. Transient sequence numbers do not match.
Main
(-)
4 Inconsistent input data. Incorrect number of transients specified PRA
(-)
5 Error in construction of Histogram PRA
(-)
6 Inconsistent input data. Transient sequence numbers do not match.
(-)
101 Memory allocation error - insufficient memory available for this execution CHECK_ALLOC
(-)