From:
YOUNG, David To:
Valliere, Nanette Cc:
Andrukat, Dennis; Lee, Pete; Helton, Shana
Subject:
[External_Sender] Summary table showing key attributes for eligibility criteria Date:
Wednesday, April 21, 2021 12:57:13 PM Attachments:
ARPS Rule Eligibility Criteria Attribute Summary Table.docx Importance:
High
- Nan,
Good afternoon.
As discussed during the meeting this morning, the attached table shows our understanding of the key attributes associated with each of the eligibility criteria. I ask that your folks review the table and then let me know if were aligned in our understanding or if adjustments are needed. Given my commitment to get you the guidance in time to support the near-term rulemaking schedule milestones, I request a timely review and return of staff feedback. Any method of providing the feedback is fine with me - telephone call, email or meeting.
David YounglTechnical Advisor Nuclear Security and Incident Preparedness Nuclear Energy Institute (202) 739-8127
This electronic message transmission contains information from the Nuclear Energy Institute, Inc. The information is intended solely for the use of the addressee and its use by any other person is not authorized. If you are not the intended recipient, you have received this communication in error, and any review, use, disclosure, copying or distribution of the contents of this communication is strictly prohibited. If you have received this electronic transmission in error, please notify the sender immediately by telephone or by electronic mail and permanently delete the original message. IRS Circular 230 disclosure: To ensure compliance with requirements imposed by the IRS and other taxing authorities, we inform you that any tax advice contained in this communication (including any attachments) is not intended or written to be used, and cannot be used, for the purpose of (i) avoiding penalties that may be imposed on any taxpayer or (ii) promoting, marketing or recommending to another party any transaction or matter addressed herein.
Sent through www.intermedia.com
ARPS Rule - Eligibility Criteria Attribute Summary Table Attributes Eligibility Criterion
§ 73.55(a)(7)(i)(A)
§ 73.55(a)(7)(i)(B)
§ 73.55(a)(7)(i)(C)
Facility Possesses a Target Set (see definition below)?
No Yes Yes Facility Possesses an Achievable Target Set (see definition below)?
N/A No Yes Credit engineered safety and security features described in licensing basis?
Yes Yes Yes Credit on-shift operator actions to prevent or mitigate consequences?
No Yes Yes Credit post-facility recovery actions to prevent or mitigate consequences?
No No Yes How is release timing and magnitude determined?
Analysis assumes DBT attack starts at T=0 and determines subsequent SSC failures Analysis assumes DBT attack starts at T=0 and determines subsequent SSC failures Analysis assumes DBT attack starts at T=0 and determines subsequent SSC failures Credit physical and chemical processes that prevent or mitigate consequences?
Yes Yes Yes A target set is the minimum combination of equipment or operator actions which, if all are prevented from performing their intended safety function or prevented from being accomplished, would result in offsite doses greater than the reference values in §§ 50.34(a)(1)(ii)(D) and 52.79(a)(1)(vi).
An achievable target set means a target set that is within the ability of the DBT to compromise, destroy, or render nonfunctional, absent actions by an onsite armed response force.