ND-21-0571, ITAAC Closure Notification on Completion of ITAAC 2.1.02.14 (Index Number 66)

From kanterella
(Redirected from ML21167A350)
Jump to navigation Jump to search
ITAAC Closure Notification on Completion of ITAAC 2.1.02.14 (Index Number 66)
ML21167A350
Person / Time
Site: Vogtle 
Issue date: 06/16/2021
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ND-21-0571
Download: ML21167A350 (7)


Text

Southern Nuclear Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel JUN 1 6 2021 Docket No.:

52-025 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 ND-21-0571 10 CFR 52.99(c)(1)

Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 ITAAC Closure Notification on Completion of ITAAC 2.1.02.14 [Index Number 661 Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.1.02.14 [Index Number 66].

This ITAAC confirms that controls in the Main Control Room operate to cause the Reactor Coolant System pressurizer heaters to turn on and off. The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEI) 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully submitted.

V^a Michael J. Yox Regulatory Affairs Diredor Vogtle 3 & 4

Enclosure:

MJY/RLB/sfr Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.1.02.14 [Index Number 66]

U.S. Nuclear Regulatory Commission ND-21-0571 Enclosure Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena III Mr. D. L. McKinney Mr. M. D. Meier Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. M. J. Yox Mr. A. S. Parton Ms. K. A. Roberts Mr. C. T. Defnall Mr. C. E. Morrow Mr. J. M. Fisher Mr. R. L. Belike Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Requlatorv Commission Ms. M. Bailey M

M Ms. A. Veil M

M M

M Ms. N. C. Coovert M

M M

M M

M M

M M

M M

M M

M

. M. King

. G. Bowman

. C. P. Patel

. G. J. Khouri C. J. Even B. J. Kemker C. Welch J. Gaslevic O. Lopez-Santiago G. Armstrong M. Webb T. Fredette C. Santos B. Davis J. Vasquez J. Eargle E. Davidson T. Fanelli Ms. K. McCurry J. Parent B. Griman

U.S. Nuclear Regulatory Commission ND-21-0571 Enclosure Page 3 of 3 Oqlethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. 8. M. Jackson Dalton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. Oriani Mr. D. 0. Durham Mr. M. M. CorlettI Mr. Z. 8. Harper Mr. J. L. Coward Other Mr. 8. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, inc.

Mr. 8. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Baich Bingham

U.S. Nuclear Regulatory Commission ND-21-0571 Enclosure Page 1 of 4 Southern Nuclear Operating Company ND-21-0571 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.1.02.14 [Index Number 66]

U.S. Nuclear Regulatory Commission ND-21-0571 Enclosure Page 2 of 4 ITAAC Statement Desion Commitment

14. Controls exist in the MCR to cause the components identified in Table 2.1.2-3 to perform the listed function.

Inspections. Tests. Analyses Testing will be performed on the components in Table 2.1.2-3 using controls in the MCR.

Acceptance Criteria Controls in the MCR operate to cause the components listed in Table 2.1.2-3 to perform the listed functions.

ITAAC Determination Basis Testing was performed in accordance with Unit 3 Initial Test Program (ITP) Work Order (WO)

SV3-RCS-T0W-1248486 (Reference 1) to verify that controls exist in the Main Control Room (MCR) to cause the components identified in Combined License (COL) Appendix C Table 2.1.2-3 (Attachment A) to perform the listed function.

Reference 1 confirmed that each pressurizer heater group turns on and off when the MCR controls are manipulated. The individual heater groups for each bank of heaters were tested to verify proper operation utilizing the Plant Control System (PLS). Testing was coordinated and performed during Unit 3 Hot Functional Testing. The MCR pressurizer heater On/Off control function was verified to control each pressurizer heater group using MCR pressurizer heater group current indication, as the pressurizer heater groups were cycled on and off.

The report documenting the Unit 3 test results, ITAAC Technical Report SV3-RCS-ITR-800066 (Reference 2), confirmed that controls in the MCR operate to cause the components listed in Attachment A to perform the listed functions.

References 1 and 2 are available for NRC inspection as part of the Unit 3 ITAAC 2.1.02.14 Completion Package (Reference 3).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all ITAAC findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant ITAAC findings associated with the ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 2.1.02.14 (Reference 3) and is available for NRC review.

ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.1.02.14 was performed for VEGP Unit 3 and that the prescribed acceptance criteria are met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

U.S. Nuclear Regulatory Commission ND-21-0571 Enclosure Page 3 of 4 References ^available for NRG inspection)

1. Work Order (WO) SV3-RCS-T0W-1248486, ITAAC 2.1.02.14 -

Testing Pressurizer Heater Controls in the Main Control Room, Revision 0

2. ITAAC Technical Report SV3-RCS-ITR-800066, Unit 3 ITAAC 2.1.02.14-Testing Pressurizer Heater Controls in the MCR, Revision 0
3. 2.1.02.14-U3-CP-Rev 0, ITAAC Completion Package

U.S. Nuclear Regulatory Commission ND-21-0571 Enclosure Page 4 of 4 Attachment A

'Excerpt from COL Appendix C Table 2.1.2-3

  • Table 2.1.2-3

^Equipment

  • Tag No.

^Control Function Pressurizer Heaters RCS-EH-03 On/Off Pressurizer Heaters RCS-EH-04A On/Off Pressurizer Heaters RCS-EH-04B On/Off Pressurizer Heaters RCS-EH-04C On/Off Pressurizer Heaters RCS-EH-04D On/Off