2019 Domestic Uranium Production Report May 2020 Independent Statistics & Analysis www.eia.gov U.S. Department of Energy Washington, DC 20585

This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIAs data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the U.S. Department of Energy or other federal agencies.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report ii Contacts This report was prepared by the staff of the Electricity Supply & Uranium Statistics & Product Innovation Team. If you have questions about the preparation and content of this report, email us at InfoNuclearData@eia.gov.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report iii Contents Contacts........................................................................................................................................................ ii Introduction.................................................................................................................................................. 1 Mining, production, shipments, and sales............................................................................................... 2 Facility status (mills, heap leach plants, and in-situ leach plants)........................................................... 2 Employment............................................................................................................................................. 3 Expenditures............................................................................................................................................ 3 Reserve estimates.................................................................................................................................... 3

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report iv Tables Table 1. U.S. uranium drilling activities, 2006-19................................................................................................ 4 Table 2. U.S. uranium mine production and number of mines and sources, 2006-19........................................ 6 Table 3. U.S. uranium concentrate production, shipments, and sales, 2006-19................................................. 6 Table 4. U.S. uranium mills and heap leach facilities by owner, location, capacity, and operating status at end of the year, 2016-19............................................................................................................................................. 7 Table 5. U.S. uranium in-situ leach plants by owner, location, capacity, and operating status at end of the year, 2016-19....................................................................................................................................................... 8 Table 6. Employment in the U.S. uranium production industry by category, 2006-19....................................... 9 Table 7. Employment in the U.S. uranium production industry by state, 2006-19........................................... 10 Table 8. U.S. uranium expenditures, 2006-19.................................................................................................... 10 Table 9. Summary production statistics of the U.S. uranium industry, 1996-2019........................................... 12 Table 10. Uranium reserve estimates at the end of 2018 and 2019.................................................................. 15

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report v

Figures Figure 1. U.S. uranium drilling by number of holes, 2006-19.............................................................................. 4 Figure 2. U.S. uranium drilling, 2006-19............................................................................................................... 5 Figure 3. Employment in the U.S. uranium production industry by category, 2005-18...................................... 9 Figure 4. U.S. uranium expenditures, 2006-19.................................................................................................. 11 Figure 5. U.S. mine production of uranium, 1996-2019.................................................................................... 13 Figure 6. U.S. uranium concentrate production and shipments, 1996-2019.................................................... 13 Figure 7. Employment in the U.S. uranium production industry, 1996-2019.................................................... 14

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 1

Introduction In this report, the U.S. Energy Information Administration (EIA) reports detailed data on U.S. uranium production activities from 2006 through 2019 and summary data back to 1996.

Data in this report are based primarily on information reported on Form EIA-851A, Domestic Uranium Production Report (Annual), and some information reported on Form EIA-858, Uranium Marketing Annual Survey. The Form EIA-851A survey collects data on uranium milling and in-situ leach processing, feed sources, mining, employment, drilling, expenditures, and reserve estimates. The Form EIA-858 survey includes data collected on uranium contracts and deliveries.

Previous editions of this report are available on our website.

Definitions for terms in this report are available in EIAs Energy Glossary.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 2

Mining, production, shipments, and sales U.S. uranium mines produced 0.17 million pounds of triuranium octoxide (U3O8), or uranium concentrate1, in 2019, 76% less than in 2018. The production of uranium concentrate is the first step in the nuclear fuel production process. The U3O8 is then converted into UF6 to first enable uranium enrichment, then fuel pellet fabrication, and finally fuel assembly fabrication.

Total production of U.S. uranium concentrate from all domestic sources in 2019 was 0.17 million pounds of U3O8, 89% less than in 2018, from six facilities: five in-situ leaching (ISL) plants in Nebraska and Wyoming (Crow Butte Operation, Lost Creek Project, Ross CPP, North Butte, and Smith Ranch-Highland Operation) and one underground mine.

Total shipments of uranium concentrate from domestic producers were 0.19 million pounds U3O8 in 2019, 87% less than in 2018.

Facility status (mills, heap leach plants, and in-situ leach plants)

At the end of 2019, Shootaring Canyon Uranium Mill in Utah and Sweetwater Uranium Project in Wyoming were on standby with a total capacity of 3,750 short tons of material per day. The White Mesa Mill in Utah, which had a capacity of 2,000 short tons of material per day, was not producing uranium. In Wyoming, one heap leach plant was in the planning stages (Sheep Mountain).

At the end of 2019, three U.S. uranium ISL plants were operating with a combined capacity of 9.5 million pounds U3O8 per year (Lost Creek Project, Nichols Ranch ISR Project, and the Smith Ranch-Highland Operation in Wyoming). Six ISL plants were on standby as of the end of 2019, and seven ISL plants were planned for four states: New Mexico, South Dakota, Texas, and Wyoming.

1A yellow or brown powder obtained by milling uranium ore, by processing of in-situ leach mining solutions, or as a byproduct of phosphoric acid production.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 3

Employment Total employment in the U.S. uranium production industry was 265 full-time person-years (one person year is equal to full-time employment for one person) in 2019, a decrease of 29% from the 2018 total. Exploration employment was 40 person-years, a 48% increase from the 2018 total. Mining employment was 48 person-years, a 56% decrease from 2018. Reclamation employment decreased 20% to 110 person-years from 2018 to 2019. Wyoming accounted for 55% of total employment in the U.S. uranium production industry in 2019, up slightly from 53% of total employment in 2018.

Expenditures Total expenditures for land, exploration, drilling, production, and reclamation were $81 million in 2019, 26%

less than in 2018.

Reserve estimates At the end of 2019, reported estimated uranium reserves were 31 million pounds U3O8 at a maximum forward cost of up to $30 per pound. At up to $50 per pound, reported estimated reserves were 206 million pounds U3O8. At up to $100 per pound, reported estimated reserves were 389 million pounds U3O8. These reserves are a fraction of likely total domestic uranium reserves because we did not include inferred resources that were not reported because of a lack of cost estimates or because the reserves were not located on actively managed properties.

The uranium reserve estimates presented here cannot be compared with the much larger historical data set of uranium reserves published in the July 2010 report U.S. Uranium Reserves Estimates. EIA estimated those reserves based on data we collected and data the National Uranium Resource Evaluation (NURE) program developed. The NURE is located in Grand Junction, Colorado, and is operated by the U.S.

Department of Energy and predecessor organizations. The EIA data include about 200 uranium properties that have reserves, collected from 1984 through 2002. The NURE data include about 800 uranium properties with reserves, developed from 1974 through 1983. Although the data collected on the Form EIA-851A survey covers a much smaller set of properties than the earlier EIA data and NURE data, we believe that within its scope the Form EIA-851A data provide more reliable estimates of the uranium recoverable at each forward cost than the estimates derived from 1974 through 2002. In particular, the Form EIA-851A data are more reliable because the NURE data have not been comprehensively updated in many years and are no longer considered a current data source.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 4

Table 1. U.S. uranium drilling activities, 2006-19 Year Exploration drilling Development drilling Exploration and development drilling number of holes feet (thousand) number of holes feet (thousand) number of holes feet (thousand) 2006 1,473 821 3,430 1,892 4,903 2,713 2007 4,351 2,200 4,996 2,946 9,347 5,146 2008 5,198 2,543 4,157 2,551 9,355 5,093 2009 1,790 1,051 3,889 2,691 5,679 3,742 2010 2,439 1,460 4,770 3,444 7,209 4,904 2011 5,441 3,322 5,156 3,003 10,597 6,325 2012 5,112 3,447 5,970 3,709 11,082 7,156 2013 1,231 919 4,013 2,926 5,244 3,845 2014 W

W W

W 1,752 1,299 2015 W

W W

W 1,518 878 2016 W

W W

W 1,158 757 2017 W

W W

W 420 196 2018 W

W W

W W

W 2019 W

W W

W W

W NA = Not available. W = Data withheld to avoid disclosure of individual company data.

Note: Totals may not equal sum of components because of independent rounding.

Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2006-19)

Figure 1. U.S. uranium drilling by number of holes, 2006-19 number of holes

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 5

Figure 2. U.S. uranium drilling, 2006-19 thousand feet

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 6

Table 2. U.S. uranium mine production and number of mines and sources, 2006-19 Table 3. U.S. uranium concentrate production, shipments, and sales, 2006-19 Production / mining method 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 (estimated contained thousand pounds U3O8)

W W

W W

W W

W W

W W

W W

W W

(estimated contained thousand pounds U3O8) 0 0

0 0

0 0

0 0

0 0

0 0

0 0

(thousand pounds U3O8) 4,259 W

W W

W W

W W

W W

W W

W W

(thousand pounds U3O8)

W W

W W

W W

W W

W W

W W

W W

(thousand pounds U3O8) 4,692 4,541 3,879 4,145 4,237 4,114 4,335 4,577 4,912 3,711 2,545 1,150 721 174 Underground 5

6 10 14 4

5 6

3 2

1 0

0 0

1 Open pit 0

0 0

0 0

0 0

0 0

0 0

0 0

0 In-Situ leaching 5

5 6

4 4

5 5

7 8

7 8

6 6

5 Other sources1 1

1 1

2 1

1 1

2 1

1 1

1 1

0 Total mines and sources 11 12 17 20 9

11 12 12 11 9

9 7

7 6

Other1 Underground Open pit In-Situ leaching Number of operating mines Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2006-19)

Total mine production E = Estimated data. W = Data withheld to avoid disclosure of individual company data.

Notes: Totals may not equal sum of components because of independent rounding. Table does not include byproduct production and sources.

1 Other includes, in various years, mine water, mill site cleanup and mill tailings, and well field restoration as sources of uranium.

Activity at U.S. mills and in-situ-leach plants 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 Ore from underground mines and stockpiles fed to mills 1 W

0 W

W W

W W

W W

0 0

0 0

W Other feed materials 2 W

W W

W W

W W

W W

W W

W W

W Total mill feed W

W W

W W

W W

W W

W W

W W

W (thousand pounds U3O8)

W W

W W

W W

W W

W W

W W

W W

(thousand pounds U3O8)

W W

W W

W W

W W

W W

W W

W W

(thousand pounds U3O8) 4,106 4,534 3,902 3,708 4,228 3,991 4,146 4,659 4,891 3,343 2,916 2,443 1,647 174 (thousand pounds U3O8) 3,838 4,050 4,130 3,620 5,137 4,000 3,911 4,655 4,593 4,023 3,018 2,277 1,489 190 Deliveries (thousand pounds U3O8) 3,786 3,602 3,656 2,044 2,684 2,870 3,630 4,447 4,746 3,634 2,691 1,254 1,541 W

Weighted-average price (dollars per pound U3O8) 28.98 42.11 43.81 36.61 37.59 52.36 49.63 44.65 39.17 42.86 38.22 41.34 32.51 W

Total uranium concentrate shipped from U.S. mills and in-situ-leach plants Estimated contained U3O8 (thousand pounds)

Uranium concentrate produced at U.S. mills Uranium concentrate produced at U.S. in-situ-leach plants Total uranium concentrate production Notes: Totals may not equal sum of components because of independent rounding.

Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2005-18), and Form EIA-858, Uranium Marketing Annual Survey (2006-19)

Total uranium concentrate sales by U.S. producers 3 E = Estimated data. W = Data withheld to avoid disclosure of individual company data.

1 Uranium ore fed to mills in any year can include ore mined and shipped to a mill during the same year, ore that was mined during a previous year and later shipped from mine-site stockpiles, ore obtained from drawdowns of stockpiles maintained at a mill site, or a combination of these options.

2 Includes for various years uranium from mill cleanup, mine water, tailings water, and other materials.

3 Sales of U.S-origin uranium only.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 7

Table 4. U.S. uranium mills and heap leach facilities by owner, location, capacity, and operating status at end of the year, 2016-19 Capacity (short tons of ore per day) 2016 2017 2018 2019 Anfield Resources Shootaring Canyon Uranium Mill Garfield, Utah 750 standby standby standby standby EFR White Mesa LLC White Mesa Mill San Juan, Utah 2,000 operating-processing alternate feed operating-processing alternate feed operating-processing alternate feed standby Energy Fuels Wyoming Inc Sheep Mountain Fremont, Wyoming 725 undeveloped undeveloped undeveloped undeveloped Kennecott Uranium Company/Wyoming Coal Resource Company Sweetwater Uranium Project Sweetwater, Wyoming 3,000 standby standby standby standby Total Capacity:

6,475 Notes: Capacity for 2018. An operating status of Operating indicates the mill usually was producing uranium concentrate at the end of the period.

Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2016-19)

- = No data reported.

1 Heap leach solutions: The separation, or dissolving-out from mined rock, of the soluble uranium constituents by the natural action of percolating a prepared chemical solution through mounded (heaped) rock material. The mounded material usually contains low grade mineralized material and waste rock, which are produced from open pit or underground mines. The solutions are collected after percolation is completed and processed to recover the valued components.

Owner Mill and heap leach1 facility name County, State (existing and planned locations)

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 8

Table 5. U.S. uranium in-situ leach plants by owner, location, capacity, and operating status at end of the year, 2016-19 2016 2017 2018 2019 AUC LLC Reno Creek Campbell, Wyoming 2,000,000 partially permitted and licensed partially permitted and licensed partially permitted and licensed partially permitted and licensed Azarga Uranium Corp Dewey Burdock Project Fall River and Custer, South Dakota 1,000,000 partially permitted and licensed partially permitted and licensed partially permitted and licensed partially permitted and licensed Cameco Crow Butte Operation Dawes, Nebraska 1,000,000 operating operating operating standby Hydro Resources, Inc.

Church Rock McKinley, New Mexico 1,000,000 partially permitted and licensed partially permitted and licensed partially permitted and licensed partially permitted and licensed Hydro Resources, Inc.

Crownpoint McKinley, New Mexico 1,000,000 partially permitted and licensed partially permitted and licensed partially permitted and licensed partially permitted and licensed Lost Creek ISR LLC Lost Creek Project Sweetwater, Wyoming 2,000,000 operating operating operating operating Mestena Uranium LLC Alta Mesa Project Brooks, Texas 1,500,000 standby standby standby standby Power Resources Inc., dba Cameco Resources Smith Ranch-Highland Operation Converse, Wyoming 5,500,000 operating operating operating operating South Texas Mining Venture Hobson ISR Plant Karnes, Texas 1,000,000 standby standby standby standby South Texas Mining Venture La Palangana Duval, Texas 1,000,000 standby standby standby standby Strata Energy Inc Ross CPP Crook, Wyoming 375,000 operating operating operating standby URI, Inc.

Kingsville Dome Kleberg, Texas 1,000,000 restoration restoration restoration restoration URI, Inc.

Rosita Duval, Texas 1,000,000 reclamation reclamation reclamation reclamation URI, Inc.

Vasquez Duval, Texas 800,000 restoration restoration restoration restoration Uranerz Energy Corporation Nichols Ranch ISR Project Johnson and Campbell, Wyoming 2,000,000 operating operating operating operating Uranium Energy Corp.

Goliad ISR Uranium Project Goliad, Texas 1,000,000 permitted and licensed permitted and licensed permitted and licensed permitted and licensed Uranium One Americas, Inc.

Jab and Antelope Sweetwater, Wyoming 2,000,000 developing developing developing developing Uranium One Americas, Inc.

Moore Ranch Campbell, Wyoming 500,000 permitted and licensed permitted and licensed permitted and licensed permitted and licensed Uranium One USA, Inc.

Willow Creek Project (Christensen Ranch and Irigaray)

Campbell and Johnson, Wyoming 1,300,000 standby operating operating standby Total Production Capacity:

26,975,000

- = No data reported.

Notes: Production capacity for 2018. An operating status of Operating indicates the in-situ-leach plant usually was producing uranium concentrate at the end of the period. Hobson ISR Plant processes uranium concentrate that came from La Palangana. Hobson and La Palangana are part of the same project. ISR stands for in-situ recovery. Christensen Ranch and Irigaray are part of the Willow Creek Project. Uranerz Energy has a tolling arrangement with Cameco Resources. Uranium is first processed at the Nichols Ranch plant and then transported to the Smith Ranch-Highland Operation plant for final processing into Uranerzs uranium concentrate. CPP stands for central processing plant.

Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2016-19)

In-situ leach plant owner In-situ leach plant name County, State (existing and planned locations)

Production capacity (pounds U3O8 per year)

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 9

Table 6. Employment in the U.S. uranium production industry by category, 2006-19 person-years Year Exploration Mining Milling Processing Reclamation Total 2006 188 121 W

W 155 755 2007 375 378 107 216 155 1,231 2008 457 558 W

W 154 1,563 2009 175 441 W

W 162 1,096 2010 211 400 W

W 125 1,073 2011 208 462 W

W 102 1,191 2012 161 462 W

W 179 1,196 2013 149 392 W

W 199 1,156 2014 86 246 W

W 161 787 2015 58 251 W

W 116 625 2016 38 255 W

W 98 560 2017 50 136 W

W 100 424 2018 27 110 W

W 138 372 2019 40 48 W

W 110 265 W = Data withheld to avoid disclosure of individual company data.

Note: Totals may not equal sum of components because of independent rounding. A large, one-time reclamation project needed to be withheld and was not included in 2016 data.

Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2006-19)

Figure 3. Employment in the U.S. uranium production industry by category, 2005-18 person-years

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 10 Table 7. Employment in the U.S. uranium production industry by state, 2006-19 person-years Table 8. U.S. uranium expenditures, 2006-19 million dollars Year Drilling 1 Production 2 Land and other 3 Total expenditures total land land exploration reclamation and other 2006 40.1 65.9 115.2 41.0 23.3 50.9 221.2 2007 67.5 90.4 178.2 77.7 50.3 50.2 336.2 2008 81.9 221.2 164.4 65.2 50.2 49.1 467.6 2009 35.4 141.0 104.0 17.3 24.2 62.4 280.5 2010 44.6 133.3 99.5 20.2 34.5 44.7 277.3 2011 53.6 168.8 96.8 19.6 43.5 33.7 319.2 2012 66.6 186.9 99.4 16.8 33.3 49.3 352.9 2013 49.9 168.2 90.6 14.6 21.6 54.4 308.7 2014 28.2 137.6 74.0 11.6 10.7 51.7 239.7 2015 28.7 118.5 76.2 12.1 4.7 59.4 223.5 2016 22.3 98.0 49.6 9.9 2.5 37.2 169.9 2017 4.0 78.3 40.2 8.9 3.7 27.7 122.5 2018 W

65.9 W

W W

W 108.8 2019 W

38.0 W

W W

W 81.0 NA = Not available. W = Data withheld to avoid disclosure of individual company data.

1 Drilling: All expenditures directly associated with exploration and development drilling.

2 Production: All expenditures for mining, milling, processing of uranium, and facility expense.

3 Land and other: All expenditures for land; geological research; geochemical and geophysical surveys; costs incurred by field personnel in the course of exploration, reclamation, and restoration work; and overhead and administrative charges directly associated with supervising and supporting field activities.

Notes: Expenditures are in nominal U.S. dollars. Totals may not equal sum of components because of independent rounding.

Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2006-19)

State(s) 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 Wyoming 195 245 301 308 348 424 512 531 416 343 323 245 197 146 Colorado and Texas 263 557 696 340 292 331 248 198 105 79 61 46 54 44 Nebraska and New Mexico 160 149 160 159 134 127 W

W W

W W

56 36 48 Arizona, Utah, and Washington 120 245 360 273 281 W

W W

W W

W W

W W

Alaska, Michigan, Nevada, and South Dakota 16 25 30 W

W W

W W

0 0

0 W

W W

California, Montana, North Dakota, Oklahoma, Oregon, Utah, and Virginia 0

9 17 W

W W

W W

W W

W W

W W

Total 755 1,231 1,563 1,096 1,073 1,191 1,196 1,156 787 625 560 424 372 265 Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2006-19).

W = Data withheld to avoid disclosure of individual company data.

Note: Totals may not equal sum of components because of independent rounding.

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 11 Figure 4. U.S. uranium expenditures, 2006-19 million dollars

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 12 Table 9. Summary production statistics of the U.S. uranium industry, 1996-2019 Exploration and development surface drililng Exploration and development drilling expenditures 1 Mine production of uranium Uranium concentrate production Uranium concentrate shipments Employment Year (million feet)

(million dollars) (million pounds U3O8)

(million pounds U3O8)

(million pounds U3O8)

(person-years) 1996 3.0 7.2 4.7 6.3 6.0 1,118 1997 4.9 20.0 4.7 5.6 5.8 1,097 1998 4.6 18.1 4.8 4.7 4.9 1,120 1999 2.5 7.9 4.5 4.6 5.5 848 2000 1.0 5.6 3.1 4.0 3.2 627 2001 0.7 2.7 2.6 2.6 2.2 423 2002 W

W 2.4 2.3 3.8 426 E2003 W

W 2.2 2.0 1.6 321 2004 1.2 10.6 2.5 2.3 2.3 420 2005 1.7 18.1 3.0 2.7 2.7 648 2006 2.7 40.1 4.7 4.1 3.8 755 2007 5.1 67.5 4.5 4.5 4.0 1,231 2008 5.1 81.9 3.9 3.9 4.1 1,563 2009 3.7 35.4 4.1 3.7 3.6 1,096 2010 4.9 44.6 4.2 4.2 5.1 1,073 2011 6.3 53.6 4.1 4.0 4.0 1,191 2012 7.2 66.6 4.3 4.1 3.9 1,196 2013 3.8 49.9 4.6 4.7 4.7 1,156 2014 1.3 28.2 4.9 4.9 4.6 787 2015 0.9 28.7 3.7 3.3 4.0 625 2016 0.8 22.3 2.5 2.9 3.0 560 2017 0.2 4.0 1.2 2.4 2.3 424 2018 W

W 0.7 1.6 1.5 372 2019 W

W 0.2 0.2 0.2 265 E = Estimated data, except for employment. W = Data withheld to avoid disclosure of individual company data.

1 Expenditures are in nominal U.S. dollars.

Note: The 2003 annual production and shipment amounts were estimated by rounding to the nearest 200,000 pounds to avoid disclosure of individual company data. A large, one-time reclamation project needed to be withheld and was not included in 2016 data.

Source: U.S. Energy Information Administration, 1996-2002 data taken from Uranium Industry Annual 2002 (May 2003), Table H1 and Table 2. 2003-2019 data from Form EIA-851A, Domestic Uranium Production Report (2003-19)

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 13 Figure 5. U.S. mine production of uranium, 1996-2019 million pounds U3O8 Figure 6. U.S. uranium concentrate production and shipments, 1996-2019 million pounds U3O8

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 14 Figure 7. Employment in the U.S. uranium production industry, 1996-2019 person-years

U.S. Energy Information Administration l 2019 Domestic Uranium Production Report 15 Table 10. Uranium reserve estimates at the end of 2018 and 2019 million pounds U3O8

$0 to $30 per pound

$0 to $50 per pound

$0 to $100 per pound

$0 to $30 per pound

$0 to $50 per pound

$0 to $100 per pound Properties with exploration completed, exploration continuing, and only assessment work W

W W

W W

W Properties under development for production and development drilling W

W W

W W

W Mines in production W

W W

W W

W Mines closed temporarily, closed permanently, and mined out W

W W

W W

W Total 43.0 174.4 353.2 31.2 206.0 388.8 In-situ leach mining W

127.6 W

W 159.1 W

Underground and open pit mining W

46.8 W

W 46.8 W

Total 43.0 174.4 353.2 31.2 206.0 388.8 Arizona, New Mexico, and Utah W

W W

W W

W Colorado, Nebraska, and Texas W

W W

W W

W Wyoming W

W W

W W

W Total 43.0 174.4 353.2 31.2 206.0 388.8 Source: U.S. Energy Information Administration, Form EIA-851A, Domestic Uranium Production Report (2018-19)

End of 2018 End of 2019 Forward Cost 2 1 These uranium reserve estimates cannot be compared with the much larger historical data set of uranium reserves that were published in the July 2010 report U.S. Uranium Reserves Estimates. Reserves, as reported here, do not necessarily imply compliance with U.S. or international government definitions for purposes of investment disclosure.

W = Data withheld to avoid disclosure of individual company data.

2 Forward Cost: The operating and capital costs still to be incurred in the production of uranium from in-place reserves. By using forward costing, estimates for reserves for ore deposits in differing geological settings and status of development can be aggregated and reported for selected cost categories.

Included are costs for labor, materials, power and fuel, royalties, payroll taxes, insurance, and applicable general and administrative costs. Excluded from forward cost estimates are prior expenditures, if any, incurred for property acquisition, exploration, mine development, and mill construction, as well as income taxes, profit, and the cost of money. Forward costs are neither the full costs of production nor the market price at which the uranium, when produced, might be sold.

Note: Totals may not equal sum of components because of independent rounding.

Uranium reserve estimates1 by mine and property status, mining method, and State(s)