Advanced Reactors GEIS Docs - TRISO Particles: the Most Robust Nuclear Fuel on Earth (DOE 2019)
ML21140A413
Person / Time
Issue date: 05/20/2021
From:
NRC
To:
NRC/NMSS/DREFS
References
Download: ML21140A413 (7)


Text

From:

Dozier, Tami Sent:

Thursday, May 20, 2021 4:34 PM To:

AdvancedReactors-GEISDocsPEm Resource

Subject:

TRISO Particles: The Most Robust Nuclear Fuel on Earth (DOE 2019)

Attachments:

DOE 2019 TRISO Particles.pdf

Hearing Identifier:

AdvancedReactors_GEIS_Public Email Number:

18 Mail Envelope Properties (BY3PR09MB7585DA4975FB97A3C4959F7EF42A9)

Subject:

TRISO Particles: The Most Robust Nuclear Fuel on Earth (DOE 2019)

Sent Date:

5/20/2021 4:33:51 PM Received Date:

5/20/2021 4:33:54 PM From:

Dozier, Tami Created By:

Tamsen.Dozier@nrc.gov Recipients:

"AdvancedReactors-GEISDocsPEm Resource"

<AdvancedReactors-GEISDocsNPR.Resource3@nrc.gov>

Tracking Status: None Post Office:

BY3PR09MB7585.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 3

5/20/2021 4:33:54 PM DOE 2019 TRISO Particles.pdf 467444 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

TRISO Particles: The Most Robust Nuclear Fuel on Earth l Department of Energy https://www.energy.gov/ne/articles/triso-particles-most-robust-nuclear-fuel-earth[11/30/2020 2:17:51 PM]

Office of NUCLEAR ENERGY National Labs Energy.gov Offices ne Home Reactor Technologies Reactor Technologies Reactor Technologies Home Light Water Reactors Advanced Reactors Advanced Reactor Demonstration Program Versatile Test Reactor Small Modular Reactors Initiatives Initiatives Initiatives Home Fuel Cycle Technologies Fuel Cycle Technologies Fuel Cycle Technologies Home Fuel Cycle Research & Development Nuclear Fuels Storage & Transportation Planning Project Systems Engineering and Integration Uranium Management and Policy Used Fuel Disposition Research & Development International Nuclear Energy Policy and Cooperation International Nuclear Energy Policy and Cooperation International Nuclear Energy Policy and Cooperation Home Bilateral Cooperation Multilateral Cooperation International Commercial Activities Nuclear Facility Operations Nuclear Facility Operations Nuclear Facility Operations Home Idaho Operations Office Facilities Management Resumption of Transient Testing Advanced Modeling & Simulation Advanced Modeling & Simulation Advanced Modeling & Simulation Home Predictive Simulation Nuclear Fuels Advanced Nuclear Reactors Nuclear Energy University Program Nuclear Energy Enabling Technologies Nuclear Energy Enabling Technologies Nuclear Energy Enabling Technologies Home Mission Benefits Crosscutting Technology Development Office of Nuclear Energy TRISO Particles: The Most Robust Nuclear Fuel on Earth JULY 9, 2019 Home >> TRISO Particles: The Most Robust Nuclear Fuel on Earth TRISO particles cannot melt in a reactor and can withstand extreme temperatures well beyond the threshold of current nuclear fuels.

About Us Search Energy.gov

TRISO Particles: The Most Robust Nuclear Fuel on Earth l Department of Energy https://www.energy.gov/ne/articles/triso-particles-most-robust-nuclear-fuel-earth[11/30/2020 2:17:51 PM]

Reactor Materials Advanced Sensors and Instrumentation Proliferation and Terrorism Risk Assessment Advanced Methods for Manufacturing Space Power Systems Space Power Systems Space Power Systems Home Space Nuclear Mission History Spent Fuel and Waste Disposition Tribal Working Group Gateway for Accelerated Innovation in Nuclear (GAIN)

Funding Opportunities NICE Future Information Resources Information Resources Information Resources Home Multimedia Resources Newsletter STEM Resources Document Library Careers Events Theres a lot of buzz around advanced nuclear.

These technologies are going to completely change the way we think about nuclear reactors.

More than 70 projects are underway in the United States with new designs that are expected to be more economical to build and operate.

Some of them will require a new fuel thats tough enough handle the higher operating temperatures of these advanced reactors.

Enter TRISO fuelthe most robust nuclear fuel on earth.

What is TRISO Fuel?

TRISO stands for TRi-structural ISOtropic particle fuel.

Each TRISO particle is made up of a uranium, carbon and oxygen fuel kernel. The kernel is encapsulated by three layers of carbon-and ceramic-based materials that prevent the release of radioactive fission products.

The particles are incredibly small (about the size of a poppy seed) and very robust.

They can be fabricated into cylindrical pellets or billiard ball-sized spheres called pebbles for use in either high temperature gas or molten salt-cooled reactors.

TRISO fuels are structurally more resistant to neutron irradiation, corrosion, oxidation and high temperatures (the factors that most impact fuel performance) than traditional reactor fuels.

Each particle acts as its own containment system thanks to its triple-coated layers. This allows them to retain fission products under all reactor conditions.

Search Energy.Gov Search

TRISO Particles: The Most Robust Nuclear Fuel on Earth l Department of Energy https://www.energy.gov/ne/articles/triso-particles-most-robust-nuclear-fuel-earth[11/30/2020 2:17:51 PM]

Simply put, TRISO particles cannot melt in a reactor and can withstand extreme temperatures that are well beyond the threshold of current nuclear fuels.

Robust TRISO Fuel Research TRISO fuel was first developed in the United States and United Kingdom in the 1960s with uranium dioxide fuel. In 2002, the Department of Energy (DOE) focused on improving TRISO fuel using uranium oxycarbide fuel kernels and enhancing its irradiation performance and manufacturing methods in order to further develop advanced high-temperature gas reactors.

In 2009, this improved TRISO fuel set an international record by achieving a 19% maximum burnup during a three-year test at Idaho

TRISO Particles: The Most Robust Nuclear Fuel on Earth l Department of Energy https://www.energy.gov/ne/articles/triso-particles-most-robust-nuclear-fuel-earth[11/30/2020 2:17:51 PM]

National Laboratory (INL). This is nearly double the previous mark set by the Germans in the 1980s and is three times the burnup that current light-water fuels can achievedemonstrating its long-life capability.

The irradiated fuel was then exposed to more than 300 hours0.00347 days <br />0.0833 hours <br />4.960317e-4 weeks <br />1.1415e-4 months <br /> of testing at temperatures up to 1800° Celsius (more than 3,000° Fahrenheit). These tests exceeded the predicted worst-case accident conditions for high-temperature gas reactors and showed no to minimal damage of the particles with full fission product retention.

Continued TRISO fuel qualification testing is currently underway at INL. With support from DOE, the Electric Power Research Institute worked with INL and industry stakeholders to submit a licensing topical report to the U.S. Nuclear Regulatory Commission (NRC) for official review. Future test results will be submitted to the NRC for licensing TRISO fuel and reactor vendors.

What's Next?

TRISO fuel testing is gaining a lot of interest from the advanced reactor community. Some reactor vendors such as X-energy and Kairos Power, along with the Department of Defense, are planning to use TRISO fuel for their designsincluding some small modular and micro-reactor concepts.

DOE is also supporting X-energys efforts to design and submit a NRC license application for a new fabrication facility. The project would ultimately use high assay low enriched uranium to produce the TRISO fuel pellets and pebbles for future high-temperature gas and molten salt reactors.

Learn More

TRISO Particles: The Most Robust Nuclear Fuel on Earth l Department of Energy https://www.energy.gov/ne/articles/triso-particles-most-robust-nuclear-fuel-earth[11/30/2020 2:17:51 PM]

TRISO fuel research is supported through the Office of Nuclear Energys Advanced Reactor Technologies (ART) program. ART sponsors collaborative efforts with universities and industry partners to accelerate research on various advanced reactor designs.

Follow us on Facebook, Twitter and LinkedIn Web Policies

  • Privacy
  • No Fear Act Whistleblower Protection
  • Information Quality Open Gov Accessibility OFFICE of NUCLEAR ENERGY 1000 Independence Ave. SW Washington DC 20585 202-586-5000

An office of ABOUT NE Careers &

Internships Initiatives Contact Us ENERGY.GOV RESOURCES Budget &

Performance Directives, Delegations &

Requirements FOIA Inspector General Privacy Program Small Business Staff &

Contractor Resources FEDERAL GOVERNMENT The White House USA.gov