May 19, 2021 Mr. Peter Hastings Vice President, Regulatory Affairs and Quality Kairos Power LLC 707 W Tower Ave Alameda, CA 94501

SUBJECT:

SUMMARY

OF TELECONFERENCE HELD ON APRIL 6, 2021, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND KAIROS POWER, LLC, TO DISCUSS REVISION 1 OF KP-TR-007-NP QUALITY ASSURANCE PROGRAM FOR THE KAIROS FLOURIDE SALT-COOLED HIGH TEMPERATURE REACTOR TOPICAL REPORT

Dear Mr. Hastings:

On April 6, 2021, the U.S. Nuclear Regulatory Commission (NRC) and representatives of Kairos Power, LLC (Kairos) held a teleconference to discuss the NRC staffs clarification questions pertaining to Revision 1 of Quality Assurance Program for the Kairos Power Flouride Salt-Cooled High Temperature Reactor Topical Report (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML21071A081).

to this letter includes a listing of the participants and Enclosure 2 provides a summary of the key points discussed in the conference call. Kairos had an opportunity to comment on this summary.

If you have any questions, please contact me by telephone at 301-415-2946 or via e-mail at samuel.cuadradodejesus@nrc.gov.

Sincerely, Samuel Cuadrado, Project Manager Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No. 99902069

Enclosures:

1. List of Participants
2. Summary of the Teleconference

ML21138A815 NRC-001 OFFICE NRR/DANU/UARL/PM NRR/DANU/UARL/LA NRR/DANU/UARL/BC NRR/DANU/UARL/PM NAME SCuadrado SLent BBeasley SCuadrado DATE 4/28/2021 5/18/2021 5/19/2021 5/19/2021

Enclosure 1 LIST OF PARTICIPANTS NAME ORGANIZATION John Price Kairos Power LLC Jonathan Ortega-Luciano U.S. Nuclear Regulatory Commission (NRC)

Stu Magruder NRC Paul Prescott NRC Samuel Cuadrado NRC

Enclosure 2

SUMMARY

OF TELECONFERENCE HELD ON APRIL 6, 2021, BETWEEN THE U.S. NUCLEAR REGULATORY COMISSION AND KAIROS POWER, LLC TO DISCUSS REVISION 1 OF KP-TR-007-NP QUALITY ASSURANCE PROGRAM FOR THE KAIROS FLOURIDE SALT-COOLED HIGH TEMPERATURE REACTOR TOPICAL REPORT The objective of the meeting was for the U.S. Nuclear Regulatory Commission (NRC) staff to obtain clarification on changes made to Revision 1 of Kairos Power, LLCs (Kairos) Quality Assurance Program (QAP) Topical Report (TR) Quality Assurance Program for the Kairos Power Flouride Salt-Cooled High Temperature Reactor Topical Report dated March 31, 2021 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML21071A081).

The NRC staff noted that the first sentence of the second paragraph in Section 1.2.5 of the QAP TR (page 11), may need some corrections as it was difficult to read. Kairos agreed with the staffs observation and stated that it will revise the sentence to make it clearer.

The staff noted that the International Laboratory Accreditation Cooperation (ILAC) conditions listed on Section 7.2 (pages 27-28) of the QAP TR are not in alignment with Revision 1, of Nuclear Energy Institute (NEI)14-05A, Guidelines for the Use of Accreditation in Lieu of Commercial Grade Surveys for Procurement of Laboratory Calibration and Test Services, as approved by the staff final safety evaluation dated November 23, 2020 (ADAMS Accession No. ML20322A019). The staff stated that for Kairos to be able to use the provision of NEI 14-05A, Revision 1, which endorses the use of ISO [International Standards Organization] 17025 (2017),

its QAP description must contain all the conditions listed in NEI 14-05A. Kairos stated that they will revise Section 7.2 of the QAP TR to align with its QAP commitment and ILAC conditions with those in Revision 1, of NEI 14-05A. Kairos also stated that it plans to incorporate the changes discussed during the meeting in a Revision 2 of the QAP TR to be submitted to the staff within a few weeks.