Westinghouse Electric Company, NRC Form 591S Part 1, Inspection Report 07109297/2021201
ML21131A031
Person / Time
Site: 07109297, 07100708
Issue date: 03/22/2021
From: Earl Love
NRC/NMSS/DFM/IOB
To: Stilwell W
Westinghouse
ECLove NMSS/DFM/IOB 301.415.7011
References
IR 2021201
Download: ML21131A031 (8)


Text

INSPECTOR NOTES COVER SHEET Licensee/Certificate Holder (name and address)

Westinghouse Electric Company, LLC (WEC)

Nuclear Fuel (NF)

Columbia Fuel Site (CFS) 5801 Bluff Road Hopkins, SC 29061 Licensee/Certificate Holder contact and phone number Wes Stilwell, NF Transport Director (803) 647-3438 Docket No.

07100708 Inspection Report No.

071-09297/2021-201 Inspection Dates(s)

January 25-28, 2021 / Exit date: March 20, 2021 Inspection Location(s)

Newington Components Manufacturing (NCM), Newington, NH Inspectors Earl Love, Team Leader, Senior Transportation and Storage Safety Inspector Marlone Davis, Senior Transportation and Storage Safety Inspector Jeremy Tapp, Transportation and Storage Safety Inspector Azmi Djapari, Transportation and Storage Safety Inspector (In Training)

Summary of Findings and Actions The inspection assessed the adequacy of NFs activities regarding the manufacture of the Traveller STD packagings accordance with the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 71, Packaging and Transportation of Radioactive Material, the applicable Certificate of Compliance (CoC), No. 71-9297, Revision 13, Packaging Safety Analysis Report, Revision 15, and WEC conformance to NRC-approved quality assurance program (QAP).

This was a first-time inspection of fabrication, assembly, and test activities for the manufacture of a Part 71 packaging at WECs NCM facility located in Newington, NH. The design activities for the standard Traveller Safety Analysis Report, current Revision 15, are performed by WECs CFS, NF division, located in Hopkins, SC in accordance with WEC QAP requirements.

On January 26, 2021, the NRC inspection team discussed the scope of the inspection with Mr. Wes Stilwell, NF Transport Director, James Dunn, Quality Assurance Manager, NCM, and other members of WEC NCM Operations management and technical staff. On March 20, 2021, the NRC inspection team presented the final inspection results, and observations to Wes Stilwell, NF Transport Director, Hopkins, SC. No findings were identified.

Lead Inspector Signature/Date 4/30/2021 Inspector Notes Approval Branch Chief Signature/Date 5/5/2021

=

Background===

WEC LLC, based in Pittsburgh, PA, holds Part 71 QAP Approval No. 71-0708, Revision 9. The QAP authorizes activities at the corporate office in Pittsburgh, WECs CFS, Hopkins, SC, and at the WEC NCM facility located in Newington, NH. All Part 71 quality assurance and CoC activities take place at WECs CFS facility. WEC NF is the Part 71 CoC holder (No. 71-9297) for Traveller packages. The Traveller is a shipping package designed to transport enriched commercial grade uranium fuel assemblies or rods. It carries several types of pressurized water reactor (PWR) fuel assemblies. There are three packaging variants in the Traveller family:

Traveller Standard, Traveller XL, and Traveller VVER. In April 2020, NF issued a contract to its WEC subsidiary NCM, for the manufacture of 50 Traveller Standard (STD) fuel shipping packagings.

Inspection Purpose The inspection assessed the adequacy of NFs activities with regard to the manufacture of the Traveller STD packagings accordance with the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 71, Packaging and Transportation of Radioactive Material, CoC No. 71-9297, Revision 13, Packaging Safety Analysis Report (PSAR), Revision 15, and WEC conformance to NRC-approved QAP.

Primary Inspection Procedures/Guidance Documents

  • IP-86001, "Design, Fabrication, Testing, and Maintenance of Transportation Packagings"
  • NUREG/CR-6314, "Quality Assurance Inspections for Shipping and Storage Containers"
  • NUREG/CR-6407, "Classification of Transportation Packaging and Dry Spent Fuel Storage System Components According to Importance to Safety"

INSPECTOR NOTES: APPLICABLE SECTIONS FROM IP 86001 WERE PERFORMED DURING THE INSPECTION WITH RESULTS DOCUMENTED BELOW UNDER THE BASIC HEADINGS OUTLINED IN NUREG-6314 Management Controls Quality Assurance Policy The NRC inspection team reviewed NCM Operations, Quality Assurance Manual (QAM) and associated implementing procedures to verify how NCM used their QAM and written procedures to fabricate and control activities related to the Standard (STD) Travellers transportation package CoC No. 71-9297, Revision 15, and associated PSAR, Revision 15. The NCM Operations QAP document is QAM-WEC-NEW-001, Quality Assurance Manual, Revision 7, which also includes various implementing procedures. The team reviewed the QAM to determine if the document clearly defined and documented the quality program authorities and responsibilities and that the quality assurance organization functioned as an independent group.

The team reviewed how WEC used a graded approached to identify Important-to-Safety (ITS) components and how WEC applied this graded quality level to procurement documents for NCM use in fabrication. The team also reviewed a sample of personnel qualifications and indoctrination training records in accordance with NCMs implementing policies and procedure PP-02-01, Indoctrination and Training, Revision 6.

The team assessed that NCM had a program and implementing procedures in place and were effective in conducting fabrication activities in accordance with CoC 71-9297 radioactive material transportation package model for the STD Traveller. The team verified that NCM clearly defined and documented the quality assurance program authorities and responsibilities and the quality assurance organization functioned as an independent group. The team assessed that WECs CFS component safety classification list for the STD Traveller appropriately identified and classified those components used to fabricate the packaging components in accordance with implementing procedures. Additionally, the personnel qualifications, and indoctrination training were also in accordance with implementing procedures.

Nonconformance and Corrective Action Controls The team reviewed NCMs nonconformance program to assess the effectiveness of measures established to control materials, parts, components, and services that have been identified by NCM as not conforming to specified requirements. The team also reviewed the corrective action program (CAP) used at NCM to assess the effectiveness of the measures established to identify and correct issues, and if required, prevent recurrence.

The team reviewed the following NCM procedures and WEC corporate quality procedure applicable to NCM:

PP-15-01 Quality Notifications, Revision 13 PP-15-02 Supplier Deviation of Contract Requirements (SDCR), Revision 8 W2-5.1-101 Westinghouse CAP Procedure, Revision 7.1 The team assessed that the quality procedures provided adequate guidance for the processing of nonconforming items and corrective actions. The team reviewed a selection of both quality notifications (QNs) and issue reports (IRs) issued for Traveller fabrication activities performed at NCM. The team also reviewed a selection of SDCRs for deviations documented by suppliers of

Traveller components and evaluated by NCM. The selection of QNs consisted of those with different dispositions such as use-as-is and repair. The team assessed that for the ten QNs and three SDCRs reviewed, they had been appropriately dispositioned, and contained adequate technical justification, as applicable. In addition, Westinghouse design engineering reviewed, and approved the technical justification when a nonconforming condition violated NCM design requirements, as required.

The team discussed the CAP and the associated controls with NCM and reviewed a sample of six IRs related to the Traveller project and internal audits performed at NCM. The team assessed that they had been adequately documented, and the corrective actions taken were adequate and performed in a timeframe commensurate with the safety significance of the issue, when possible.

The team reviewed CAP IR-2020-13749, written to address use of commercial weld material on assemblies designated as ITS-A. The team assessed NCMs corrective and preventive actions, and resolution and closure. Overall, the team concluded that NCM conducted adequate testing/analysis (weld wire and welded samples) to provide reasonable assurance that the welding materials provided were of the appropriate AWS classification and that chemical analysis results of destructively tested production welds and X-Ray Fluorescence (XRF) testing were compliant with ASME Section IX. The team determined that the weld wire CAP adequately addressed the issue and was properly closed and that NCM fully implemented its QA program (QAM-WEC-NEW-001, Revision 07, dated 12/06/2019) in the area of corrective action. Refer to Fabrication and Assembly Controls that describes the teams assessment of NCMs weld wire testing to address use of commercial weld material on assemblies designated as ITS-A.

The team concluded that NCM had an adequate nonconformance control and CAP in place to identify, track and resolve quality related deficiencies and deviations.

Part 21 Requirements The team reviewed program controls for 10 CFR Part 21, "Reporting of Defects and Noncompliances," including W2-5.1-201, "Identification and Reporting of Conditions Adverse to Nuclear Safety," Revision 2.0. The team verified that the corporate Westinghouse procedure implemented at NCM met the requirements of the Part 21 regulations and takes responsibility for the reporting requirements, if necessary. There were no closed or open Part 21 reports related to the Traveller work. The team noted no concerns regarding 10 CFR Part 21 program controls or implementation at NCM.

Audit Program The team reviewed the internal audit program as defined in Westinghouse corporate quality procedure W2-4.2-101, Internal Quality Assurance Audits, Revision 4.0 implemented at NCM.

This was to verify that the program was comprehensive and that audits were scheduled and conducted periodically in accordance with approved procedures by trained and qualified audit personnel who documented the audit results and followed up deficient areas via the CAP. The team also reviewed the qualifications of a selection of audit team leaders and members to determine if they were qualified in accordance with QA-2.8, Qualification of Audit Personnel, Revision 1.1, as required.

The team reviewed the internal audit schedules for NCM since 2016 and noted that internal audits of all aspects of NCMs quality program were audited annually by Westinghouse

corporate. The team also reviewed the internal audits performed in 2019 and 2020 to verify that they were conducted in accordance with the approved quality procedure. The team determined that for the internal audit reports and checklists reviewed, the audits were adequate and performed by those independent of the areas being audited, reviewed a representative sample of NCMs activities in the area being audited, and the audit reports were written in a timely manner. The team also noted that the 2021 audit plan scheduled NCM for an audit of all applicable quality areas. For the auditor training records that were reviewed, all were trained and qualified as required by the approved procedure.

The team determined that for the NCM audits reviewed, they were comprehensive in nature and identified issues to correct and improve the QAP. Overall, the team assessed that the internal audit program was adequately implemented at NCM by performing audits with trained and qualified personnel of all applicable aspects of the quality assurance program.

Fabrication Controls Material Procurement The team reviewed NCM Operation processes and procedures that addresses material procurement, including traceability and receipt inspection of all material used in fabrication of the STD Traveller radioactive transportation package. The team reviewed selected drawings, records and interviewed personnel to verify that the procurement specifications for materials, fabrication, inspection, and services performed at NCM met the design and procurement requirements of the STD Traveller components. The team selected the clamshell assembly, poison plates, ceramic paper shock mount cover, and hinge pins based on their ITS classification. The team reviewed the following design documents, purchase orders (POs),

specifications and NCMs policies and procedures:

PDSHIP05, Traveller Shipping Package Specification, Revision 8, PDSHIP04, Traveller Specification for Neutron Poison, Revision 4, PO 4500786398 PP-04-01, Procurement Document Control, Revision 22 PP-04-03, Shelf Life Program, Revision 4 PP-08-01, Goods Receipt Slip, Revision 14 PP-08-06, Identification and Control of Items, Revision 3 Drawing 10006E67H12, H14, H15, H20, and H21, Clamshell Assembly Drawing 10006E90H18, Poison Plate Drawing 10007E02H01, Hinge Pin Drawing 10006E69, Ceramic Paper Overall, the team assessed that NCM had adequate control of the procurement process for the ITS Category A and B components reviewed. The team determined that NCM controlled procurement of ITS components consistent with design and procurement requirements and their implementing procedures. The team assessed that NCM had adequate controls of material traceability, procurement, and receipt inspection. The team also determined that the purchase orders were adequate and specified the applicable criteria and requirements including Part 21.

Fabrication and Assembly During this inspection, the NRC inspection team observed fabrication and assembly activities associated with inspections and special processes (welding, examination) of a sample of 50

Traveller Standard (STD) fuel shipping packagings that were in various stages of production at the time of the inspection.

The NRC inspection team walked down that portion of the shop floor where NCM Operations was performing welding of Upper and Lower Outerpack Assemblies including Support Shelf Sub-assembly welding. For welding and nondestructive examination (NDE) activities, the team reviewed various production orders (shop travelers), visual examination (VT) reports and observed welding. Further, the NRC inspection team reviewed the detailed welding procedure, associated procedure qualification records, welder qualifications and the base metal and filler metal certified material test reports (CMTRs). The team observed NCM Operations quality inspectors as they performed in-process and final inspections to verify conformance of items to specified requirements. The team reviewed that persons performing in-process and final inspections were qualified and the inspection results, including deviations, were properly documented. Based on the limited sample of documents reviewed, the team determined that NCM Operations is implementing its policies and procedures associated with packaging manufacturing and inspection control. No findings were identified.

The team noted WEC self-identified that several production Fuel Traveller assemblies and sub-assemblies designated as ITS-A as having been welded using weld wire that was procured commercially and that the supplier who provided the weld material was not appropriately qualified as a supplier of ITS-A components. The team noted NCM incorrectly assumed that because certain parts for the applicable sub-assembly were class B that the weld wire did not need to be procured as ITS-A. Subsequently, the team assessed that NCM adequately conducted mechanical testing and chemical analysis of as-deposited weld samples, chemical analysis of the bare wire, and XRF testing of all accessible production welds of the affected assemblies and sub-assemblies to demonstrate as-laid weld, and remaining weld wire meet the chemistry and tensile requirements as initially invoked. Refer to Nonconformance and Corrective Action Controls that describes the teams assessment of NCMs corrective actions taken to address use of commercial weld material on assemblies designated as ITS-A.

The team determined that NCM Operations implemented its programs for documentation control, inspection, manufacturing control, control of special processes, control of measuring and test equipment, training, and nonconformance process in accordance with the applicable regulatory requirements of Appendix H to 10 CFR Part 71. Based on the limited sample of documents reviewed and activities observed, the inspection team also determined that NCM Operations is implementing its policies and procedures associated with these programs. No findings were identified.

Tools and Equipment The team reviewed selected measuring and test equipment (M&TE) including records and procedures to assure that equipment used in activities affecting quality were properly controlled and calibrated. The team reviewed NCM quality procedure PP-12-01, Measuring and Test Equipment Calibration and Issue, Revision 19, which prescribes activities and requirements concerning use of M&TE; that calibration occurs to national standards; performance of certain calibration activities; maintenance of records of various tools and equipment used; and actions to take when any piece of equipment is found out of calibration.

The team selected a sample of M&TE and reviewed the associated calibration records to determine if the equipment was calibrated as required by PP-12-01. The M&TE selected consisted of weld gages, steel rule, light meter, standardization coin, caliper, gage blocks, and ball set, in which each were found to be in calibration and had current calibration certificates, as

applicable. The team also selected a sample of M&TE Discrepancy Reports for review to determine whether M&TE found out of calibration, or discrepant, were adequately evaluated as required by PP-12-01.

The team concluded that the M&TE quality procedure being implemented at NCM provided adequate guidance for M&TE calibration and use, and NCM had adequately implemented M&TE calibration and discrepant equipment requirements.