ML21118A010
| ML21118A010 | |
| Person / Time | |
|---|---|
| Site: | Braidwood |
| Issue date: | 04/28/2021 |
| From: | Keenan J Exelon Generation Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21118A009 | List: |
| References | |
| BW210032 | |
| Download: ML21118A010 (2) | |
Text
Exelon Generation April 28, 2021 BW210032 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Braidwood Station, Units 1 and 2 Exelon Generation Company. LLC Braidwood Station 35100 South Route 53, Suite 84 Braceville, IL 60407-9619 10 CFR 50.55a Renewed Facility Operating License Nos. NPF-72 and NPF-77 NRG Docket Nos. STN 50-456 and STN 50-457
Subject:
Braidwood Station Fourth Ten-Year Interval lnservice Testing Program Plan, Revision 4 In accordance with the American Society of Mechanical Engineers (ASME) Operations and Maintenance of Nuclear Power Plants (OM Code), Subsection ISTA-3200, "Administrative Requirements," paragraph (a), attached for your information is a copy of Revision 4 of the Braidwood Station lnservice Testing (1ST) Program Plan for the fourth ten-year interval. The Braidwood Station fourth ten-year interval 1ST Program Plan complies with the requirements of the ASME OM Code 2012 Edition. The fourth ten-year interval began on July 29, 2018 and ends on July 28, 2028.
There are no regulatory commitments contained in this letter.
If you have any questions regarding this matter, please contact Mr. Kevin Lueshen, Regulatory Assurance Manager, at (815) 417-2800.
Sincerely, h P Di_g.. itally signed by Keen.an, John P.
Keen a n JO n ON: cn=Keenan, John P.
I
- Date: 2021.04.22 13:49:59 -05'00' John P. Keenan Site Vice President Braidwood Station
Attachment:
Braidwood Nuclear Power Station Units 1 and 2, lnservice Testing Program Fourth Ten Year Interval, Revision 4
cc:
NRC Regional Administrator, Region Ill NRC Senior Resident Inspector-Braidwood Station NRC Project Manager, NRR _; Braidwood and Byron Stations Illinois Emergency Management Agency-Division of Nuclear Safety