Proposed Rule to Incorporate by Reference the 2019 and 2020 Editions of ASME Codes into 10 CFR 50.55a May 6, 2021 ADAMS Accession No. ML21116A030
2 Agenda
- Purpose and Overview
- ASME Section III and XI (Quality Assurance)
- Open Discussion
3 Purpose and Overview Victoria Huckabay Division of Rulemaking, Environmental, and Financial Support Office of Nuclear Material Safety and Safeguards
Purpose of Meeting
- Brief status of the ongoing rulemaking
- NRC staffs position regarding incorporation by reference of the ASME 2019 and 2020 Code Editions
- NRC will consider information and perspectives discussed today when developing the final rule, but comments must be submitted in writing through the methods described in the Federal Register notice to receive formal consideration in the rulemaking 4
CS1
Slide 4 CS1 This should be stronger. I suggest "but comments must be submitted in writing through the methods described in the Federal Register notice to receive formal consideration in the rulemaking."
Clark, Sheldon, 4/29/2021
Submitting Comments
- Federal Rulemaking Website: Go to https://www.regulations.gov and search for Docket ID NRC-2018-0290.
- Email comments to:
Rulemaking.Comments@nrc.gov. If you do not receive an automatic email reply confirming receipt, then contact us at 301-415-1677.
5
Current Rulemaking
- Proposed rule to incorporate by reference the 2019 Edition of the ASME Boiler and Pressure Vessel and the 2020 Edition of the ASME OM Code was published in the Federal Register on March 26, 2021 (86 FR 16087)
(RIN 3150-AK22, Docket ID NRC-2018-0290) 6
Rulemaking Process 7
Final Rule Proposed Rule Regulatory (Technical)
Basis Identify need for rulemaking It has been NRCs practice to use ASME codes to establish requirements for nuclear power plants.
- Foundation of effective rulemaking
- Draft rule text
- Public meeting
- 60 day public comment period
- Final rule text Opportunities for public participation 7
IBR 2019 - 2020 Editions
Timeline -
Edition/Addenda Rulemakings Publication Year ASME BPV Code ASME OM NRC Proposed Rule NRC Final Rule 2005 2005 Addenda 2005 Addenda 2006 2006 Addenda 2006 Addenda 2007 2007 Edition 72 FR 16731 (4/5/2007) 2008 2008 Addenda 73 FR 52730 (9/10/2008) 2009 2009 Addenda 2009 Edition 2010 2010 Edition 75 FR 24324 (5/4/2010) 2011 2011 Addenda 2011 Addenda 76 FR 36232 (6/21/2011) 2012 2012 Edition 2013 2013 Edition 2014 2015 2015 Edition 2015 Edition 80 FR 56820 (9/18/2015) 2016 2017 2017 Edition 2017 Edition 82 FR 32934 (7/18/2017) 2018 83 FR 56156 (11/9/2018) 2019 2019 Edition 2020 2020 Edition 86 FR 16087 (3/26/2021) 85 FR 26540 (5/4/2020)*
2021 2022 Target: June 2022 9
- Correction Notice was published in 85 FR 34087 (6/3/2020)
Scope of ASME 2019-2020 Editions Rulemaking
- One new condition being considered
- Five* revised conditions being considered
- One new condition being considered
- Amending seven* existing conditions being considered 9
- Includes revisions to Quality Assurance conditions
Scope of ASME 2019-2020 Editions Rulemaking (contd)
- One new condition being considered
- Amending seven existing conditions being considered
- One condition is being considered for removal
- Incorporate by reference the 2011 Addenda to ASME NQA-1-2008 (ASME NQA-1b-2011), and the 2012 and 2015 Editions of ASME NQA-1
- Amending one condition on Section III rules and one condition on Section XI rules being considered 10
ASME 2019-2020 Editions RulemakingSchedule
- Proposed rule published in the Federal Register on March 26, 2021 (86 FR 16087) day public comment period ends on May 25, 2021
- NRC will consider public comments submitted on the docket
- Docket ID: NRC-2018-0290
- Target date to publish final rule in the Federal Register: June 30, 2022 11
12 ASME Section III Conditions under Consideration Dr. Chakrapani Basavaraju Division of Engineering and External Hazards Office of Nuclear Reactor Regulation
- Section III Condition: Preservice Inspection of Steam Generator Tubes. Applicants or licensees applying the provisions of NB-5283 and NB-5360 in the 2019 Edition of Section III, must apply paragraphs (b)(1)(xiii)(A) through (B) of this section.
(A) First provision. When applying the provisions of NB-5283 in the 2019 Edition of Section III, a full-length preservice examination of 100 percent of the steam generator tubing in each newly installed steam generator must be performed prior to plant startup.
Section III New Condition 13
- Section III Condition: Preservice Inspection of Steam Generator Tubes. (contd)
(B) Second provision. When applying the provisions of NB-5360 in the 2019 Edition of Section III, flaws revealed during preservice examination of steam generator tubing performed in accordance with paragraphs (b)(1)(xiii)(A) must be evaluated using the criteria in the design specifications.
Section III New Condition (contd) 14
- Section 50.55a(b)(1)(ii): Section III Condition: Weld leg dimensions
- Subparagraphs NB-3683.4(c)(1) and NB-3683.4(c)(2):
Condition Applicable to 1989 Addenda through the latest Edition.
- Note 11 to Table NC-3673.2(b)-1 and Note 11 to Table ND-3673.2(b)-1: Condition Applicable to 2011 Addenda through the latest Edition.
- Section 50.55a(b)(1)(iii): Section III, Condition: Seismic design of piping
- Applicable to 2006 Addenda through all Editions and addenda up to and including the latest Edition.
Section III Revised Conditions 15
- Section 50.55a(b)(1)(vii): Section III, Condition: Capacity certification and demonstration of function of incompressible-fluid pressure-relief valves
- Applicable to 2006 Addenda through all Editions and addenda up to and including the latest Edition.
- Section 50.55a(b)(1)(x): Section III Condition: Visual examination of bolts, studs, and nuts
- Provisions are applicable to 2017 and later Editions of Section III.
Section III Revised Conditions (contd) 16
17 ASME Section III and XI Conditions under Consideration (Quality Assurance)
Yamir Diaz-Castillo Division of Reactor Oversight Office of Nuclear Reactor Regulation
Revise§50.55a(b)(1)(iv)Section III Condition: Quality Assurance
- The NRC is proposing to revise this condition to allow use of the editions of NQA-1 that are both incorporated by reference in § 50.55a(a)(1)(v) and specified in either NCA-4000 or NCA-7000 of the 1989 or later editions of Section III. This will allow applicants and licensees to use the 2011 Addenda to ASME NQA-1-2008, "Quality Assurance Requirements for Nuclear Facility Applications (ASME NQA-1b-2011), and the 2012 and 2015 Edition of NQA-1 when using the 2019 and later Editions of Section III, which this rule is also incorporating by reference.
Section III Revised Condition 18
Revise§ CFR 50.55a(b)(2)(x)Section XI condition: Quality assurance The NRC is proposing to revise this condition to allow the use of the editions of NQA-1 that are both incorporated by reference in § 50.55a(a)(1)(v) and specified in Table IWA-1600-1 of the 1989 or later Editions of Section XI. In the 2019 Edition of ASME BPV Code,Section XI, Table IWA-1600-1 was updated to specify that licensees use the 1994 Edition or 2008 Edition through 2015 Editions of NQA-1 when using the 2019 Edition of Section XI. These revisions will allow licensees to use the 2011 Addenda to ASME NQA-1-2008, and the 2012 and 2015 Edition of NQA-1 when using the 2019 and later Editions of Section XI, which this rule is also incorporating by reference.
- The paragraph is also being revised to remove the reference to IWA-1400. This revision clarifies the condition because the editions of NQA-1 are referenced in Table IWA 1600-1 instead of IWA-1400.
Section XI Revised Condition (contd) 19
20 ASME Section XI Conditions under Consideration Keith Hoffman Division of New and Renewed Licenses Office of Nuclear Reactor Regulation
Section XI Revised Conditions
- Section 50.55a(b)(2)(xviii)Section XI condition: NDE personnel certification:
- NDE personnel certification based on results of PNNL research propose to provide options
- Level I - 175 hours0.00203 days <br />0.0486 hours <br />2.893519e-4 weeks <br />6.65875e-5 months <br /> experience, 125 experience/50 lab practice
- Level II - 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> experience, 400 experience/320 lab practice and successful completion of Appendix VIII, Supplement 2 detection and length sizing
- Section 50.55a(b)(2)(xxv)Section XI condition: Mitigation of defects by modification:
- Mitigation of defects by modification providing options for future examinations and eliminating some timing aspects 21 25
Section XI Revised Conditions (contd)
- Section 50.55a(b)(2)(xxvi)Section XI condition: Pressure testing Class 1, 2 and 3 mechanical joints:
- Proposing revision to Licensee defined leak check
- Section 50.55a(b)(2)(xxix)Section XI condition:
Nonmandatory Appendix R:
- Allow use of 2017/2019 Editions Supplement 2 without submittal of an alternative
- Section 50.55a(b)(2)(xxxii)Section XI condition:
Summary report submittal:
- Summary report submittal extended to 120 days 22 26
Section XI Revised Conditions (contd)
- Section 50.55a(b)(2)(xl)Section XI condition:
Prohibitions on use of IWB-3510.4(b):
- Considering the prohibition of use of IWB-3510.4(b),
IWC-3510.5(b), and Tables A-4200-1 and G-2110-1 23 27
- Section 50.55a(b)(2)(xliii)Section XI condition:
Regulatory Submittal Requirements
- Requires submittal to NRC of analysis performed in accordance with IWB-3720(a), A-4200(c), and G-2110(c)
Section XI New Condition 24
25 ASME OM Code Conditions under Consideration Robert Wolfgang Division of Engineering and External Hazards Office of Nuclear Reactor Regulation
Specific OM Items of Interest in Proposed Rulemaking
- Remove incorporation by reference of 2011 Addenda of ASME OM Code from 10 CFR 50.55a(1)(iv)(B)(2) and consequently remove condition on use of 2011 Addenda specified in 10 CFR 50.55a(b)(3)(vii) as well as reference to 2011 Addenda in 10 CFR 50.55a(b)(3)(ix).
- Remove incorporation by reference of 2015 Edition of ASME OM Code from 10 CFR 50.55a(a)(1)(iv)(C)(2) and the reference to 2015 Edition in 10 CFR 50.55a(b)(3)(vii) and 10 CFR 50.55a(b)(3)(ix).
26
Specific OM Items of Interest in Proposed Rulemaking
- Modify 10 CFR 50.55a(f)(4) to clarify relationship between 50.55a(f)(4) and (g)(4) regarding Inservice Testing (IST) or Inservice Inspection (ISI) programs for snubbers. Include a provision to clarify that for snubbers, inservice examination, testing and service life monitoring for IST or ISI program must meet inservice examination and testing requirements set forth in applicable ASME OM Code or ASME BPV Code,Section XI, as specified in 10 CFR 50.55a(b)(3)(v)(A) and (B).
27
Specific OM Items of Interest in Proposed Rulemaking
- In light of removal of IST Program Plan submittal requirement from 2020 Edition of ASME OM Code, add 10 CFR 50.55a(f)(7) to require nuclear power plant applicants and licensees to submit IST Plans and interim IST Plan updates related to pumps and valves, and IST Plans and interim Plan updates related to snubber examination and testing, to NRC.
- Consideration of proposed relaxation of the interval for position verification testing required in ISTC-3700 for valves that are not susceptible to stem-disk separation.
28
Specific OM Items of Interest in Proposed Rulemaking
- Amend 10 CFR 50.55a(b)(3)(iii) to change the applicability date to read "April 17, 2018" instead of "the date 12 months after April 17, 2017."
29
How to get involved?
30 To find information about Search for docket ID ASME 2019-2020 rulemaking NRC-2018-0290
How did we do?
- Link to NRC Public Meeting Feedback form:
31
Questions & Comments Victoria Huckabay, Project Manager Division of Rulemaking, Environmental, and Financial Support Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Email: Victoria.Huckabay@nrc.gov Phone: 301-415-1325 32 ASME 2019-2020 Rulemaking
Acronyms ADAMS Agencywide Documents Access and Management System ASME American Society of Mechanical Engineers BPV Boiler and Pressure Vessel CFR Code of Federal Regulations FR Federal Register IBR Incorporation by Reference ISI Inservice Inspection IST Inservice Testing NDE Non-destructive Evaluation NRC Nuclear Regulatory Commission OM Operation and Maintenance RIN Regulation Identifier Number 33