From:

Shea, James Sent:

Tuesday, April 13, 2021 8:51 AM To:

Schichlein, Lisa (GE Power Portfolio); GEH-BWRX-300DocsPEm Resource Cc:

Wadkins, George (GE Power Portfolio); Schiller, Alina; Dudek, Michael; Cranston, Greg; Wittick, Brian; Li, Chang

Subject:

Verification of the GEH BWRX-300 LTR NEDC-33911P-A, Revision 1, BWRX-300 Containment Performance Attachments:

NRC 896 A TR Verification GEH BWRX-300 LTR NEDC-33911P-A Containment Performance.pdf Lisa, In a Letter dated April 7, 2021 (NRC Verification Letter ADAMS ML21098A151 linked below),

the staff has verified that the submitted -A version is acceptable and is approved for referencing in future licensing applications for the BWRX-300 to the extent specified and under the limitations delineated. In addition the signed NRC LTR Verification Form 896 is attached.

View ADAMS Properties ML21098A151 Open ADAMS Document (NRC Staff Verification Letter for GEH LTR NEDC-33911P-A, Revision 1 BWRX-300 Containment Performance)

Also The Public -A version will be linked on the NRC BWRX-300 public website.

https://www.nrc.gov/reactors/new-reactors/smr/bwrx-300.html James Shea Senior Project Manager phone: (301)415-1388 james.shea@nrc.gov U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Mail Stop O-7D21 Washington, DC, 20555-0001

Hearing Identifier:

GEH_BWRX300_Docs_Public Email Number:

3 Mail Envelope Properties (DM8PR09MB6901D46A3C4ECE77550057F6944F9)

Subject:

Verification of the GEH BWRX-300 LTR NEDC-33911P-A, Revision 1, BWRX-300 Containment Performance Sent Date:

4/13/2021 8:51:19 AM Received Date:

4/13/2021 8:51:29 AM From:

Shea, James Created By:

James.Shea@nrc.gov Recipients:

"Wadkins, George (GE Power Portfolio)" <George.Wadkins@ge.com>

Tracking Status: None "Schiller, Alina" <Alina.Schiller@nrc.gov>

Tracking Status: None "Dudek, Michael" <Michael.Dudek@nrc.gov>

Tracking Status: None "Cranston, Greg" <Gregory.Cranston@nrc.gov>

Tracking Status: None "Wittick, Brian" <Brian.Wittick@nrc.gov>

Tracking Status: None "Li, Chang" <Chang.Li@nrc.gov>

Tracking Status: None "Schichlein, Lisa (GE Power Portfolio)" <lisa.schichlein@ge.com>

Tracking Status: None "GEH-BWRX-300DocsPEm Resource" <GEH-BWRX-300DocsPEm.Resource@nrc.gov>

Tracking Status: None Post Office:

DM8PR09MB6901.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1514 4/13/2021 8:51:29 AM NRC 896 A TR Verification GEH BWRX-300 LTR NEDC-33911P-A Containment Performance.pdf 1314032 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

NRC FORM 896 (01-2021)

-A Topical Report Verification U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 896 (01-2021)

Page 1 of 1 Topical Report Information Report Number:

NEDC-33911P-A, REVISION 1

Title:

BWRX-300 CONTAINMENT PERFORMANCE ADAMS Accession Number:

PKG ML21076B028 EPID:

EPID: L-2020-TOP-0015 Docket Number:

99900003 (GEH Wilmington)

Review Information Office/Division/

Branch:

NRR/DSS/SCPB Lead Reviewers Project Manager:

James Shea Reviewers:

Chang Li, Lead Angelo Stubbs, Second Lead Staff Verification Determination ADAMS Accession Numbers for this Review Package: ML E-mail: ML This Form: ML

The NRC staff has determined that the topical report is acceptable to the extent delineated in the NRC staff's safety evaluation dated:

March 12, 2021 ADAMS Accession No.: ML21008A370 Based on its review of the changes documented in the topical report, the NRC staff has determined that the -

A report is not acceptable for referencing in licensing actions.

Basis for Denial:

Approvals Technical Branch Chief Projects Branch Chief Brian D. Wittick Digitally signed by Brian D. Wittick Date: 2021.03.31 16:41:16 -04'00' Michael I. Dudek Digitally signed by Michael I. Dudek Date: 2021.04.07 15:58:18 -04'00'