1 Allen, William From:
Plate, Nicholas S CIV USN NNPP (USA) <nicholas.plate@navy.mil>
Sent:
Monday, April 5, 2021 1:34 PM To:
Allen, William Cc:
Subject:
[External_Sender] RE: Nav D2g ThermalDiffusivityCompletedResponse:
Thereisatypographicalerrorforthestatedunitforthermaldiffusivity.Thestatedunitisft2/s.Theunitshouldstate ft2/hrinaccordancewiththeASMEBPVCreferencefromwherevaluesaresourced.Thetypographicalerroris applicabletoTableA2.22(sheets10,11,&12)andTableA31.However,thereisnotechnicalimpactsincethethermal diffusivityvalueswereappliedwiththecorrectunit(ft2/hr).TheonlySARPcalculationwhichappliesthermaldiffusivity valuesisonTableA31tocalculatethecorrespondingspecificheatforthematerials(seeNote3).Wewillcorrectthe typographicalerroronaroutinebasis.
Wecanprovideameetingsummary(similartoModel1corebarrelSARPmeetingsummary)inthenextdayortwoto capture/documentthediscussionaboveifyouneeditforyourSER-justletmeknowandIllgetthatballrolling.
- Thanks, Nick
NuclearEngineer NavalReactors-ReactorServicingDivision 2027816034(work) 2026647388(cell)
From:Plate,NicholasSCIVUSNNNPP(USA)
Sent:Monday,April5,20219:31AM To:'William.Allen@nrc.gov'<William.Allen@nrc.gov>
Subject:
RE:NavD2g
ChrisThanksforpointingthisouttous.ThesubjectvaluesarereferencedfromtheASMEBPVC,asnotedinTable A2.22,withunitsofft2/hr.Itappearswehaveeditoriallabelerrorsforthesevaluesstatingft2/s,butwealsoneedto confirmthatwedidntincorrectlyapplythesevalues/unitsinanyoftheanalyses.Wellhaveacompleteresponseto youbylatertodayortomorrow,andthenwecandiscusshowtodocumentthecorrection.
Onaseparatetopic,IhavetheM140CoCrenewalrequestandassociatedSARPrevisionsreadyfordropoff.Pleaselet meknowadate/timethatworksbestforyou.
- Thanks, Nick
NuclearEngineer NavalReactors-ReactorServicingDivision 2027816034(work) 2026647388(cell)
2
From:Allen,William<William.Allen@nrc.gov>
Sent:Saturday,April3,202110:34PM To:Plate,NicholasSCIVUSNNNPP(USA)<nicholas.plate@navy.mil>
Subject:
[NonDoDSource]FW:NavD2g
- Nick,
Afterreviewingtheemailstringbelow,pleasereachouttothefolksinPittsburghanddetermineifthereisa typographicalerrorinSARTableA31.
Thanks,Chris
From:Ahn,Tae<Tae.Ahn@nrc.gov>
Sent:Tuesday,March30,202112:30PM To:Borowsky,Joseph<Joseph.Borowsky@nrc.gov>;Allen,William<William.Allen@nrc.gov>
Subject:
RE:NavD2g
I agree with you, Joe, with hour. Thanks.
From:Borowsky,Joseph<Joseph.Borowsky@nrc.gov>
Sent:Tuesday,March30,202112:08PM To:Ahn,Tae<Tae.Ahn@nrc.gov>;Allen,William<William.Allen@nrc.gov>
Subject:
RE:NavD2g
IputtheSARbackinthesafebeforeyousentyouremail.Letsjustsaythatametalsthermaldiffusivityisontheorder of0.5ft2/hr(accordingtomyreferencebooks).However,theSARtablewouldlistitas0.5ft2/sec.Ithinkitisatypo withtheunits.Theapplicantcanconfirmifthatisthecaseornot.
From:Ahn,Tae<Tae.Ahn@nrc.gov>
Sent:Tuesday,March30,202112:01PM To:Borowsky,Joseph<Joseph.Borowsky@nrc.gov>;Allen,William<William.Allen@nrc.gov>
Subject:
RE:NavD2g
Joe, if the thermal diffusivity is classified, I will go to NRC to confirm. If it is not classified, could you tell me that value to me? I guess you already confirmed it, pretty easily. Please let me know. Thanks. Tae From:Borowsky,Joseph<Joseph.Borowsky@nrc.gov>
Sent:Tuesday,March30,202111:53AM To:Allen,William<William.Allen@nrc.gov>
Cc:Ahn,Tae<Tae.Ahn@nrc.gov>
Subject:
NavD2g
- HiChris,
ImessentiallyfinishedwithmySERfortheD2g,whichwaspreviouslycertified.Itappearsthereisanincorrectunitin TableA31forthermaldiffusivityofthemetals.Aspotcheckofthevalue(i.e.,thenumberinthetable)appearstobe reasonableiftheunitwaschangedtoaperhourbasis.InthematerialpropertysectionmySERcurrentlywilljustsay thatthepackagewaspreviouslyreviewed.However,inyourphonecallswiththeapplicantitmaybebesttoaskthemif
3 thereisatypoinSARTableA31forthethermaldiffusivityunit.Itappearsthatpropertywasnotexplicitlyusedinthe thermalanalyses.
Thanks.