ML21097A046

From kanterella
Jump to navigation Jump to search
M210413: Slides - Sell - Regulatory Preparedness for Advanced Reactors - ARDP Perspective
ML21097A046
Person / Time
Issue date: 04/13/2021
From:
NRC/OCM
To:
Shared Package
ML21026A016 List:
References
M210413
Download: ML21097A046 (5)


Text

© 2021 X Energy, LLC, All Rights Reserved 1

© 2020 X Energy LLC, all rights reserved 1

Regulatory Preparedness for Advanced Reactors - ARDP Perspective J. Clay Sell Chief Executive Officer, X Energy, LLC April 13, 2021

© 2021 X Energy, LLC, All Rights Reserved 2

The Xe-100 Leverages Proven Technology With Novel Integration 1944 ORNL USA 1966-1975 Dragon UK 1966-1974 Peach Bottom USA 1967-1988 AVR Germany 1967-1988 Fort St. Vrain USA 1986-1989 THTR Germany 1998-Present HTTR Japan 2000-Present HTR-10 China 2005 - Present USA USA 2009 - Present The Xe-100 represents continuous innovation to improve safety and economics with a focus on simplicity, reliability, and flexibility The Xe-100 leverages the significant regulatory interactions and operating experience of past advanced reactor designs Xe-100 fuel development leverages the U.S. DOE investment of +$700 million for development and testing of UCO TRISO coated particles Pebble Bed HTGRs

© 2021 X Energy, LLC, All Rights Reserved 3

NGNP Legacy Challenges and Resolutions Resolutions to all these challenges are in place and available for demonstration.

o Mechanistic Source Term o Functional Containment (Retention of Fission Products) o Licensing Basis Event Selection o Risk-informed Classification of Structures, Systems, and Components o Performance-based Emergency Planning and Preparedness Challenges for efficient and timely advanced reactor deployment.

o Alignment of expectations for PRA development through design and licensing o Security by Design o HALEU supply chain readiness

© 2021 X Energy, LLC, All Rights Reserved 4

Fuel Fabrication, Qualification and High Temperature Materials Fuel Fabrication and Production o X-energys TRISO-X commercial-scale fabrication capability is producing high-quality coated-particle fuel today.

Fuel Transportation o Versa-Pak 55 containers ready for finished-product transport.

Fuel Qualification & Performance o The Xe-100 benefits from the DOE Advanced Gas Reactor Fuel R&D program activities like the 2019 EPRI-sponsored TRISO fuel performance topical report & 2020 NRC safety evaluation.

High Temperature Materials o Final endorsement of ASME BPVC Section III, Division 5 standard for High Temperature Reactors will provide confidence in associated design and analysis results.

99.999% of Fission products Retained These 1mm particles retain 99.999% of the fission products

© 2021 X Energy, LLC, All Rights Reserved 5

© 2020 X Energy LLC, all rights reserved 5