ML21088A428
| ML21088A428 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 03/29/2021 |
| From: | Lippard G Dominion Energy South Carolina |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| 21-101 | |
| Download: ML21088A428 (1) | |
Text
V.C. Summer Nuclear Station Bradham Blvd & Hwy 215, Jenkinsville, SC 29065 Mailing Address:
P.O. Box 88, Jenkinsville, SC 29065 Dominion Energy.com Attn: Document Control Desk March 29, 2021 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 DOMINION ENERGY SOUTH CAROLINA (DESC)
VIRGIL C. SUMMER NUCLEAR STATION (VCSNS) UNIT 1 SPECIAL REPORT 2021-001
!ij; Dominion
~
Energy Serial No. 21 -101 VCS UC/HK/Rev 0 Docket No. 50-395 License No. NPF-12 INOPERABLE LOOSE-PART MONITORING SYSTEM CHANNEL Dominion Energy South Carolina, Inc. (DESC) is submitting this Special Report 2021 -
001 pursuant to the requirements of Technical Specifications (TS) 3.3.3.10 Action a and TS 6.9.2. This special report is required by VCSNS TS because Loose Part Monitoring System (LPMS) Channel 8 has been inoperable for greater than 30 days.
LPMS Channel 8, monitoring Steam Generator (SG) "C," was declared inoperable on February 24, 2021 due to erratic operation, ostensibly caused by an intermittent connection in the Channel 8 signal transducer (IAT00758) circuit. Channel 8 has been disabled in LPMS. However, SG "C" LPMS Channel 9 continues to monitor SG "C" for loose parts, only without Channel 8 coincidence. Loss of dual channel coincidence merely reduces one aspect of the false alarm filtering functionality. The failed transducer (IAT00758) is scheduled for repair or replacement during Refuel 26 in Fall 2021.
Should you have any questions, please call Michael S. Moore at (803) 345-4752.
Sincerely,
~~
George A. Lippard Site Vice President V.C. Summer Nuclear Station Commitments contained in this letter: None cc:
G. J. Lindamood - Santee Cooper L. Dudes - NRC Region II V. Thomas - NRC Project Manager NRC Resident Inspector