ML21075A224

From kanterella
Jump to navigation Jump to search
DC-2021-01 Draft Written Comments
ML21075A224
Person / Time
Site: Diablo Canyon  
Issue date: 02/12/2021
From: Greg Werner
Operations Branch IV
To:
Pacific Gas & Electric Co
References
Download: ML21075A224 (27)


Text

The first set of data is for the draft exam review and the second set of data with all Sat questions is the final product as given.

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9

1. LOK 2. LOD 6

7 Ans Letter CFR 8

Q#

(F/H)

(1-5) stem focus cueing T/F cred dist partial job link minutia

  1. /

units back-ward K/A SRO-only B/M/N U/E/S A/B/C/

D 55.41 55.43 Explanation General Comments

1. LOD is 1, 2, 3, 4, 5 (no in between in NUREG)
2. Be careful with Graphics (FAQ discourages use) 8 questions on this exam with them and a few were not required
3. Be careful with Tier 1 and Tier 2 questions. Most of the time you can separate the two out in the stem of the question by how you ask the question (see below for details) 1 H

3 N

S B

7 2

F 3

N S

B 7

3 F

2 N

E A

10 Distracter wording for part 1) should be 1) are all or 1) are NOT all. This may cue a leter question for PZR level instruments.

Licensee going to write new or get bank question 4

F 2

N S

D 2

5 H

3 N

S D

10 6

F 3

N S

C 5

7 F

3 N

S C

8 8

H 3

B S

B 7

2016 NRC 9

H 3

B S

D 7

10 H

3 B

S B

11 2016 NRC 11 F

2 B

E A

5 would be better to expand A into other distracters to include how much decay heat (4% power) and when (30 minutes from trip). This is the fundamental design flow and setup for AFW. These may not be exactly your numbers but you get the point. Licensee going to fix distracter D.

3. Psychometric Flaws
4. Job Content Flaws
5. Other a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 12 H

2 B

U B

5 2012 NRC.

C and D are not credible. When would a pipe receive steam/water and its temp go down? Also, this question is not the spirit of the KA.

It is wanting to know how sensors and detectors are affected by a vapor space event (ie the ref leg heats up, flashes, affects the indicated level). Other KAs address this topic quite well.

Licensee will fix this.

13 F

2 N

E A

7 Distracters B2 and D2 are not credible. There is no info in the stem on loss of power. Also, this question does not meet the spirit of the KA. What sump level instrument do you monitor during a SBLOCA? It isn't the two you have in this question because they fail. You could just ask which sump level do you monitor ? A. LR-XX B. LR-YY C. LR-60 D LR-61.

Licensee will make suggested fixes.

14 F

2 N

E A

5 this is an fundamental question not higher order. Change worksheet. Also, you can put the LOD number in the space where you have the X for Mem/Fund and it saves time and space.

15 F

2 B

S C

7 2012 NRC a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 16 H

2 N

E C

5 stem could be trimmed down to

.the following indications below (get rid of seal 2 and same on all RCPs). Second, the name on the tag and valve in the display picture do not match the name of HCV-142 in the stem. Only one can be correct. To simplify this question, use A. clockwise to increase seal injection flow B.

clockwise to lower seal DP C.

counterclockwise to lower seal DP D. counterclockwise to increase seal injection flow. D is now correct. Simple 1 X 4 and straight-forward. Licensee will make suggested fixes.

17 F

2 B

E A

2 NRC 2009.

If OE for DC is vortexing then ask vortexing question not cavitation.

Also, is there a cav. pump on any scenarios? Licensee will make it a vortexting question to match OE.

18 H

2 N

U C

7 KA mismatch. Where is the malfunction for the PZR PCS?

Also, this is really a power supply question as written for part 1. For part 2 it is testing the interlock at 17%. Licensee will make repairs so that it is a malfunction not ps question.

19 F

2 N

E C

6 What makes the 100 foot level credible? Affects A1 and B1.

Licensee will add credibility to explanation for 100 ft level. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 20 F

1 N

U A

6 Cueing. You have bullet info for blocking SI circuits complete in the stem and answer is prevent unblocking SI. Easy fix is to remove the "maintaining RCS pressure less than 1865 psig" from the stem and put the actual KA words "cycling HPI/PORV" in the stem and answer A would be to control pressure < 1865 psig.

Also minimize subcooling is not credible for C. Could put something like stabilize RCS temperature? Licensee will make repairs to eliminate cueing.

21 F

3 B

E D

5 2016 NRC Cut/paste error on answer D in lower section. Text is incorrect.

22 H

3 M

S C

7 23 H

3 M

E A

7 Are the labels on the picture the actual labels on the panels?

Distracter B is not credible w/o other stem conditions to give it credibility. Worksheet correct answer discussion needs work (drops to zero amps....). Licensee is working on this one.

24 F

2 N

U B

10 Ka mismatch How is this meeting the KA for operate/monitor ASW service water TEMPS? License will come up with panels and instruments used to monitor this since is sea water temp basically.

25 H

3 B

E C

7 2016 NRC Change C distracter to remains the same for fail as is valve credibility. Licensee will make the suggested change to C.

26 H

3 N

S C

5 a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 27 H

2 B

S B

10 NRC 2011 REFERENCE NEEDED 28 F

2 N

S D

10 29 H

2 N

S A

5 30 H

3 N

E A

7 NUREG states to avoid adding other equipment into the topic/question when possible. If you just ask the PS for the BAMU pumps you will have it. You could do a Unit 1 and Unit 2 table with BA1-1 and BA 1-2 being A. F and G or B. G and H and BA 2-1 and BA-2-2 being C. F and H or D. G and F and whatever combos you use make sure only one is correct.

With the question you have and only two pumps it doesn't seem credible to have both BAMU pumps (see B and C distracters) with a loss of one safety bus.

Licensee is making suggested changes.

31 H

2 N

E A

10 Licensee will make mods to the stem.

32 H

3 N

E C

5 Need according "to" the entry conditions (missing to) in the stem. You have written this as a Tier 1 but you might be able to write it as a Tier 2 by having a surveillance going on and ECCS header ruptures (ie what do you see and how do you mitigate this condition?). Licensee says it is not reasonable to make that change for this KA so they will add verbiage that this KA must be written to include LOCA for ECCS header evaluation. No KA change, accept as is. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 33 H

2 B

E D

7 NRC 2018 If D is correct you have to mark it correct in the worksheet. All four choices are INCORRECT as marked in the worksheet.

Licensee will fix this issue.

34 F

3 N

E C

7 A1 and B1 are not credible. I would suggest this:

A. prevent flashing in CCW piping during LBLOCA only B. prevent flashing in CFCU during LBLOCA only C. prevent water hammer in CCW piping during LBLOCA coincident with LOSP D. prevent water hammer in CFCU during LBLOCA coincident with LOSP. Answer is C. Licensee will make repairs by removing A1 and B1 and using more credible setup as suggested.

35 H

1 B

U A

7 2014 NRC LOD=1. It is a PORV, it relieves pressure. You could ask what is the SP (415psig and one or both open, or 435 and one or both open). Could ask what is logic for press instruments. Licensee will make repairs as suggested.

36 H

3 B

S A

7 2016 NRC 37 H

3 B

E C

7 2016 NRC The PZR level channels are used in a previous question-overlap-use a different RPS circuit to base this question. Licensee looking at new question for Q3. Will check overlap then.

38 H

3 N

S A

7 39 H

3 M

S C

7 a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 40 F

2 N

E B

7 1 is not credible. To better serve the KA on the isolation, use RM-12 and RM-44 as your RM choices and close different sets of valves (purge exh and purge supply). That creates a balanced 2 X 2. Licensee will make suggested repairs.

41 F

2 N

E B

10 written as Tier 1 question. Easy to fix. Could ask how is RHR (ECCS) connected to CSS? A. upstream of 9001A/B B. downstream of 9001A/B C. suction of CSS pumps D. downstream of 9003A/B answer B. Licensee has easy fix for this one.

42 H

3 B

S C

7 NRC 2018 43 H

2 B

S B

5 NRC 2018 44 H

2 N

U B

7 C and D not credible (could use dp or inst failure). Also, if we have this type of failure on scenarios then we shouldn't use graphics on this topic. Licensee will make the trend down to be different than scenarios as use dp for C1 and D1.

45 H

2 N

E D

10 Distracter credibility. For distracter B is it no flow because MFW or AFW level control valves will

...A is not credible either. How could a safety system not work (AFW) for the SG when the non-safety (MFW) does? Is this a failure on the op test? Licensee will make repairs by using the AFW flow control valves and median select mode in the question. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 46 H

2 B

E B

7 2019 NRC I had to use a mag glass to read the labels. Are you giving them a bigger picture of this? It isn't needed anyway and NRC FAQ discourages frequent use of graphics on the written exam.Why not just ask which if the following switchyard breakers can be operated from the control room?

A. B. C. D. and pick only one that can be and three that can't be operated but maybe they can be monitored. Licensee agreed to fix to something more straightforward with breakers than can/can't be operated from CR that are switchyard breakers.

47 F

2 B

S B

8 2019 NRC 48 H

2 B

U B

10 2018 NRC This question appears to be reverse logic. The KA is predict impact ON DC Electrical from the ground and you really ask what bus are the three loads in the stem located (either D or E). To ask it in the forward direction, you should ask something like (keep stem same up to asking the question)

"What is the impact on the DC electrical system?" And your choices should be A) Dispatch operator to check that C/P breaker 72-1233..... tripped B)

Dispatch operator to check that C/P breaker xx-yyyyy (the E CP BKR) tripped C)

Trip the reactor then trip the three loads in the stem D) Continue in AR while tripping the 4kv bus feeder breaker You also need power in the stem of the question. Also your writeup is inconsistent with what loads are on D and E. Look at A and C...Loads are on (D or E)...Licensee will make suggested repairs. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 49 H

3 B

E A

7 Licensee doesn't really have a blackout sequencer and this question is a LOCA interrupted with a LOSP not an SBO event (so it doesn't really fit the KA).

Also, the question could just ask for what is the sequence of loads for a blackout on the EDG when power is returned to the safety bus by the EDG? Licensee would like to write a new question with a different KA. Agreed.

50 F

2 B

S B

8 2012 NRC 51 H

3 B

S D

11 2018 NRC 52 F

2 B

S A

7 2016 NRC 53 H

2 N

E D

10 This is a Tier 1 question as written, not Tier 2. Could ask where certain valves can be operated (what panels) and any special switches (such as local/remote, etc) or two handed ops required? Licensee will make suggested changes.

54 H

2 B

S B

5 2018 NRC 55 F

3 N

E B

11 This is Tier 2 as written. Easy fix is just ask what does the alarm sound like and who activates the alarm when needed (containment evac procedure could be put in stem but don't put an event in the stem). Licensee agrees and will make the suggested change. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 56 H

3 N

E A

7 This is a Tier 2 question but KA is imposible to write with valid alarms and not be just a system question. You don't need the graphics though. Graphics are discouraged IAW FAQ on NRC website except where necessary.

You could have in the stem that Containment pressure is 19 psig on all four channels. How would you verify that these are correct?

Need to document in the discussion that hard to write as Tier 2 but graphic not needed in either case.

57 H

2 B

S C

2 58 F

2 N

E C

7 minor edits to remove slight cueing. Need to remove "in the" from the stem and put "in the" for A2 and C2 and for B2 and D2 put "at the". One is a panel and one is a room.

59 H

2 B

U D

5 KA mismatch. No reference leg leak in the question.

60 H

3 B

S A

10 REFERENCE NEEDED 61 H

2 N

U B

11 KA mismatch-no detector type used in question. Licensee wil fix thi 62 H

3 N

S D

5 63 F

2 B

S D

12 2012 NRC 64 H

2 B

S A

5 2012 NRC 65 H

3 N

S A

5 66 F

2 B

S A

10 2016 NRC 67 F

2 N

U C

10 Non-credible distracters A, and B.

Licensee will replace A and B and adjust stem accordingly.

68 F

2 B

S D

12 69 F

2 B

S C

2 2016 NRC a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 70 F

2 N

S C

10 71 F

2 B

E A

10 Non credible distracter D and C is borderline. It would be better to have a 2 X 2 with when it is done and how or where is it documented? Licensee will update with when and where in a new 2 X 2.

72 H

2 B

S C

12 2016 NRC 73 F

2 N

E B

12 2 is not credible for the RO. We also already have something like this on the exam in another question. Licensee will develop new question with overlap in mind.

74 F

2 B

E D

Is it PAM1 or PAMS1? Need to be consistent in stem and discussion.

Put in CFR reference. Licensee will fix and make answer D Gamma Metrics to avoid overlap.

75 F

22 N

S B

10 a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 76 H

2 B

E B

5 2012 NRC This technically meets the KA for basis but it is really a fundamental design question not an SRO question on TS bases. Every RO has to know that two CCW pumps are required for the vital loop and adding the ASW pumps to the question is not desired per the NUREG unless you can't come up with anything else. This question will need to be modified and focus on CCW only.

Licensee will use TS and basis info (pull bank question from 141 exam that they already have).

77 H

2 N

S D

5 78 H

3 B

S C

5 2019 NRC 79 H

2 B

E C

5 2016 NRC The structure of each choice should be procedure selection first, then aux info after that to balance the choices. Answer C needs a comma after Salt Water in procedure title to match D.

80 H

2 N

E A

2 Need to add voltage/grid disturbance to stem to lock in KA (doesn't affect question however).

81 H

2 B

S B

5 2018 NRC a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 82 H

3 B

U C

5 2012 NRC Unsat for two non-credible distracters. For distracter B the plant trips is in the stem so it is not credible to have in the distracter that RTR is not needed (wording also is confusing because it implies it was entered but does not need to be completed but that isn't clear in the choices or stem that it was entered). Distracter D is not credible because this would mean that nothing is done to fight the tube rupture. Two other items, RM-15 in the stem might help with another question so we need to look at that. Also, there is another question on use of AOP/EOPs (Q99) so we need to change that question since this KA is specific for this topic to prevent overlap.

Licensee will make suggested repairs and compare overlap with Q99 to ensure none exists.

83 H

2 N

E D

1 Too easy as written. Here is a suggested writeup:

A. Make declaration at 1115 based on time of receipt of initial fire alarm B. Make the declaration st 1117 based on time of confirmation of fire C. Make the declaration at 1107 based on start of EAL review at 1105 D. Make the declaration at 1107 based on the report at 1107.

Licensee would like to write a new question on this topic.

84 H

2 B

S D

2 2016 NRC 85 H

3 N

S A

5 86 H

3 N

S C

5 a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 87 H

3 B

U B

3 Cueing from stem to answer. LCO 3.5.2 ECCS-Operating in stem and ECCS and LCO 3.5.2 in answer B. Licensee will remove 3.5.2 from the stem and adjust to remove cueing.

88 H

3 B

E D

3 2014 NRC Need to structure all choices the same Distracter A.

should start with "direct", Answer D should start with "direct," For distracter C remove the word "possibly". For answer D, start with "direct the operator to place a second CCW HX in service to comply with LCO 3.7.9 (or the actual procedure used to do this would be better here) to prevent exceeding CCW........" Licensee will make suggested changes.

89 F

2 N

U B

2 RO knowledge to know that in LBLOCA, AFW doesn't help you.

Throw that out and you have the answer. Again, what is the bases for AFW (capacities, decay heat, flow, how many SG's must it cool, what water level it is supposed to maintain. Licensee will incorporate TS into the question to fix these items.

90 H

2 N

E C

2 Easily challengeable as written.

Using the word "may" in NRC questions is highly discouraged in NUREG for this reason. Use values not lines available. Split the toggles between operable and inoperable. This is what the SRO has to know. Not operable or may remain operable. Licensee will make suggested repairs with values. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 91 H

3 M

U D

Reverse Logic-This KA is the effect of Core Damage ON the ITM system, not the converse (ie use ITMs to assess Core damage). Need to see parent to see how modified. I would recommend using the SAMG for two choices because with core damage what is the ability to use the ITM will come into play in the SAMG entry criteria. A disfigured core will impact at least a portion of the ITM system. Licensee is working on this one with SAMG entry as possibility.

92 F

2 B

E B

7 2016 NRC I believe that "Z-Z tape indicates full down" is correct, not "Z-Z tape indicates the full down" 93 H

2 B

S A

4 2018 NRC 94 H

3 N

S B

2 REFERENCE NEEDED 95 F

2 B

E B

7 2016 NRC Item 1 is not credible for the SRO. Also in item 2 using the exact words from the procedure are discouraged in questions per NUREG because it demonstrates rote memorization versus applied learning. Licensee will make suggested repairs.

96 F

3 N

E A

10 C and D are not a good fit for this question. You could use a pink tage or you could you use Open-Neutral or Open-mid position for a distracter (I am just asking here to help). Licensee will look at changes to this one. a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 97 F

2 N

E D

10 Part 1 of all four choices in not credible (from the stem),

especially for the SRO exam.

Makes the question too easy also.

For part 2 you only need to say "T/S activities with high risk" to remove extra focus and not cue to higher authority for approval.

Licensee will adjust stem wording and distracter wording to correct these issues as discussed.

98 F

2 B

S A

3 2018 NRC 99 F

3 N

E C

5 This question as written is already covered in another question (Q82) and this KA does not ask about AOPs so we need to center this question on something different to prevent overlap with Q82.

Licensee looking at this wrt overlap.

100 H

3 N

S C

5 Results Table RO LOK -H 42 56 Avg RO LOD 2.61 Flaws 10 CFR Distribution RO LOK-F 33 AVG SRO LOD 2.44 Stem focus 0

41(b)1 0

43(b)1 1 SRO LOK - H 18 Overall LOD 2.57 Cues 0

41(b)2 4

43(b)2 5 SRO LOK - F 7

T/F 0

41(b)3 0

43(b)3 3 Cred Dist 0

41(b)4 0

43(b)4 1 RO Bank 35 46.67 SRO Bank 12 48 Partial 0

41(b)5 15 43(b)5 10 RO Mod 3

4 SRO Mod 1

4 job link 0

41(b)6 2

43(b)6 0 RO New 37 49.33 SRO New 12 48 units 0

41(b)7 26 43(b)7 2 minutia 0

41(b)8 3

Total Bank 47 47 backward 0

41(b)9 0

Total Mod 4

4 KA 0

41(b)10 16 Total New 49 49 SRO-only 0

41(b)11 4

LOD = 1 2

41(b)12 4

RO Sat 37 49.33 SRO Sat 10 40 41(b)13 0

RO Unsat 10 13.33 SRO Unsat 4

16 Answer Dist ( in %)

41(b)14 0 a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 RO Edit 28 37.33 SRO Edit 11 44 RO-A 21 SRO-A 5

RO-B 20 SRO-B 7

Total Sat 47 47 Total Unsat 14 14 RO-C 20 SRO-C 7

Total Edit 39 39 RO-D 14 SRO-D 6 a Rev 3

Question Overlap with the Previous Two NRC Exams QA form ES-401-6 item 4 requires 4 or less questions on RO exam from previous two NRC exams, SRO portion two or less questions from previous two NRC exams*

  • if this is exceeded, the region shall call NRR to explain why/reasons.

RO overlap from previous two NRC exams (2019-01 AND 2020-02 EXAMS)

Q46 2019 Q47 2019 SRO overlap from the previous two NRC exams Q78 2019 Note: the previous two exams considered for overlap are the 2020-02 and 2019-01 NRC Exams

Questions Requiring References to Answer 6-10 questions rule of thumb on SRO portion of exam are allowed to be open reference, while the RO exam is generally none RO Questions that require hand-outs Q27 EOP ECA-1.1 APPENDIX G (1 page)

Q60 OP AP-7 Attachment 2 (1 page)

SRO Questions that require hand-outs Q94 ECG 7.4 (4 pages)

The first set of data is for the draft exam review and the second set of data with all Sat questions is the final product as given.

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9

1. LOK 2. LOD 6

7 Ans Letter CFR 8

Q#

(F/H)

(1-5) stem focus cueing T/F cred dist partial job link minutia

  1. /

units back-ward K/A SRO-only B/M/N U/E/S A/B/C/

D 55.41 55.43 Explanation With rev 3 of RO and SRO questions all questions were Sat 1

H 3

N S

B 7

2 F

3 N

S B

7 3

F 2

N S

A 10 4

F 2

N S

D 2

5 H

3 N

S D

10 6

F 3

N S

C 5

7 F

3 N

S C

8 8

H 3

B S

B 7

2016 NRC 9

H 3

B S

D 7

10 H

3 B

S B

11 2016 NRC 11 F

2 B

S A

5 2019 NRC 12 H

2 B

S B

5 2017 Callaway NRC.

13 F

2 N

S D

7 14 F

2 N

S A

5 15 F

2 B

S C

7 2012 NRC 16 H

2 N

S C

5 17 F

2 B

S D

2 2009 NRC 18 H

2 N

S A

7 19 F

2 N

S C

6 20 F

2 N

S A

10 21 F

3 B

S D

5 2016 NRC 22 H

3 M

S C

7 23 H

3 M

S A

7 24 F

2 N

S D

10 25 H

3 B

S D

7 2016 NRC 26 H

3 N

S C

5 27 H

2 B

S B

10 2011 NRC REFERENCE NEEDED

3. Psychometric Flaws
4. Job Content Flaws
5. Other a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 28 F

2 N

S D

10 29 H

2 N

S A

5 30 H

3 N

S A

7 31 H

2 N

S A

10 32 H

3 N

S C

5 33 H

2 B

S D

7 2018 NRC 34 F

3 N

S C

7 35 H

3 N

S A

7 36 H

3 B

S A

7 2016 NRC 37 H

3 B

S C

7 2016 NRC 38 H

3 N

S A

7 39 H

3 M

S C

7 40 F

2 N

S B

7 41 F

2 B

S D

10 2016 NRC 42 H

3 B

S C

7 2018 NRC 43 H

2 B

S B

5 2018 NRC 44 H

3 N

S C

7 45 H

2 N

S A

10 46 F

2 B

S A

7 2019 NRC 47 F

2 B

S B

8 2019 NRC 48 H

2 B

S C

10 2018 NRC 49 H

3 B

S D

7 2018 NRC 50 F

2 B

S B

8 2012 NRC 51 H

3 B

S D

11 2018 NRC 52 F

2 B

S A

7 2016 NRC 53 H

2 N

S C

10 54 H

2 B

S B

5 2018 NRC 55 F

3 N

S B

11 56 H

3 N

S B

7 57 H

2 N

S C

2 58 F

2 N

S C

7 59 H

3 N

S D

5 a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 60 H

3 B

S A

10 2018 NRC REFERENCE NEEDED 61 H

3 B

S D

11 2016 NRC 62 H

3 N

S D

5 63 F

2 B

S D

12 2012 NRC 64 H

2 B

S A

5 2012 NRC 65 H

3 N

S A

5 66 F

2 B

S A

10 2016 NRC 67 F

2 N

S B

10 68 F

2 B

S D

12 69 F

2 B

S C

2 2016 NRC 70 F

2 N

S C

10 71 F

2 B

S C

10 2018 NRC 72 H

2 B

S C

12 2016 NRC 73 F

2 B

S D

12 2020 NRC 74 F

2 M

S A

6 2016 NRC 75 F

2 N

S B

10 76 H

2 B

S C

5 2016 NRC 77 H

2 N

S D

5 78 H

3 B

S D

5 2019 NRC 79 H

2 B

S C

5 2016 NRC 80 H

2 N

S A

2 81 H

2 B

S B

5 2018 NRC 82 H

3 B

S B

5 2012 NRC 83 H

3 N

S B

1 84 H

2 B

S D

2 2016 NRC 85 H

3 N

S A

5 86 H

3 N

S C

5 87 H

3 B

S B

3 2019 NRC 88 H

3 B

S D

2 2014 NRC 89 F

3 N

S A

2 90 H

2 N

S B

2 91 H

3 N

S D

5 92 F

2 B

S B

7 2016 NRC.

93 H

2 B

S A

4 2018 NRC a Rev 3

ES-401 DC-2021-01 Written Examination Review Worksheet Form ES-401-9 94 H

3 N

S B

2 REFERENCE NEEDED 95 F

2 B

S B

7 2016 NRC 96 F

3 N

S A

10 97 F

2 N

S D

10 98 F

2 B

S A

4 2018 NRC 99 F

3 N

S A

5 100 H

3 N

S C

5 Results Table RO LOK -H 41 54.67 Avg RO LOD 2.43 Flaws 10 CFR Distribution RO LOK-F 34 AVG SRO LOD 2.52 Stem focus 0

41(b)1 0

43(b)1 1 SRO LOK - H 18 Overall LOD 2.45 Cues 0

41(b)2 4

43(b)2 6 SRO LOK - F 7

T/F 0

41(b)3 0

43(b)3 1 Cred Dist 0

41(b)4 0

43(b)4 2 RO Bank 34 45.33 SRO Bank 12 48 Partial 0

41(b)5 15 43(b)5 11 RO Mod 4

5.333 SRO Mod 0

0 job link 0

41(b)6 2

43(b)6 0 RO New 37 49.33 SRO New 13 52 units 0

41(b)7 26 43(b)7 2 minutia 0

41(b)8 3

Total Bank 46 46 backward 0

41(b)9 0

Total Mod 4

4 KA 0

41(b)10 17 Total New 50 50 SRO-only 0

41(b)11 4

LOD = 1 0

41(b)12 4

RO Sat 75 100 SRO Sat 25 100 41(b)13 0

RO Unsat 0

0 SRO Unsat 0

0 Answer Dist ( in %)

41(b)14 0

RO Edit 0

0 SRO Edit 0

0 RO-A 20 SRO-A 7

RO-B 15 SRO-B 8

Total Sat 100 100 Total Unsat 0

0 RO-C 21 SRO-C 4

Total Edit 0

0 RO-D 19 SRO-D 6 a Rev 3

Question Overlap with the Previous Two NRC Exams QA form ES-401-6 item 4 requires 4 or less questions on RO exam from previous two NRC exams, SRO portion two or less questions from previous two NRC exams*

  • if this is exceeded, the region shall call NRR to explain why/reasons.

RO overlap from previous two NRC exams (2019-01 AND 2020-02 EXAMS)

Q11 2019 Q46 2019 Q47 2019 Q73 2020 SRO overlap from the previous two NRC exams Q78 2019 Q87 2019 Note: the previous two exams considered for overlap are the 2020-02 and 2019-01 NRC Exams

Questions Requiring References to Answer 6-10 questions rule of thumb on SRO portion of exam are allowed to be open reference, while the RO exam is generally none RO Questions that require hand-outs Q27 EOP ECA-1.1 APPENDIX G (1 page)

Q60 OP AP-7 Attachment 2 (1 page)

SRO Questions that require hand-outs Q94 ECG 7.4 (4 pages)