March 12, 2021 Ms. Michelle Catts Senior Vice President, Nuclear Programs GE-Hitachi Nuclear Energy Americas, LLC P.O. Box 780, M/C A-18 Wilmington, NC 28402

SUBJECT:

FINAL SAFETY EVALUATION FOR GE-HITACHI LICENSING TOPICAL REPORT NEDC-33911P, REVISION 0, SUPPLEMENT 1, BWRX-300 CONTAINMENT PERFORMANCE

Dear Ms. Catts:

By letter dated March 31, 2020, GE-Hitachi Nuclear Energy Americas, LLC (GEH), submitted Licensing Topical Report (LTR) NEDC-33911P, Revision 0, BWRX-300 Containment Performance (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20091S340), to the U.S. Nuclear Regulatory Commission (NRC) staff for review and approval in support of a future licensing application for the GEH small modular reactor (SMR) under Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities, or Part 52, Licenses, Certifications, and Approvals for Nuclear Power Plants. By letter dated September 4, 2020 (ADAMS Accession No. ML20248H570), GEH submitted Revision 0, Supplement 1 of the LTR.

The NRC staff has found LTR NEDC-33911P, Revision 0, as updated by the September 4, 2020, supplement, to be acceptable for referencing in licensing applications for the GEH SMR design to the extent specified in the enclosed safety evaluation (SE). The SE defines the basis for acceptance of the LTR. In addition, on March 1, 2021 (ADAMS Accession No. ML21049A340), the Advisory Committee on Reactor Safeguards concluded that the staffs SE for LTR NEDC-33911P, Revision 0, Supplement 1, with the limitations and conditions imposed, is appropriate and should be issued.

In accordance with the guidance provided on the NRCs LTR website (http://www.nrc.gov/about-nrc/regulatory/licensing/topical-reports.html), the NRC requests that GEH publish an accepted version of this LTR within three months of receipt of this letter. The accepted version shall incorporate this letter and the enclosed SE after the title page. Also, it must contain in its appendices historical review information, such as requests for additional information, accepted responses, and the actual revised pages (showing revision bars) that were included as part of NEDC-33911P Revision 0, Supplement 1. The accepted version shall include an "-A" (designated accepted) following the report identification symbol.

If the NRCs criteria or regulations change so that its conclusion in this letter (that the LTR is acceptable) is invalidated, GEH and/or an applicant referencing the LTR will be expected to revise and resubmit its respective documentation or submit justification for the continued applicability of the LTR without revision of the respective documentation.

If you have any questions or comments concerning this matter, I can be reached via e-mail at James.Shea@nrc.gov.

Sincerely,

/RA/

James J. Shea, Senior Project Manager New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation Docket No.: 99900003

Enclosure:

Safety Evaluation cc: Listserv

PKG: ML21070A352 LTR: ML21070A353 SE: ML21008A371(Public)

SE: ML21008A370 (Non-Public)

NRR-106 OFFICE DNRL/NRLB:PM DNRL/NRLB:LA DNRL/NRLB:PM DNRL/NRLB: BC NAME ASchiller SGreen JShea MDudek DATE 03/09/2021 03/09/2021 03/09/2021 03/12/2021