Louisiana Energy Services, LLC, Dba Urenco USA, Semi-Annual Radiological Effluent Release Report for July 1, 2020 Through December 31, 2020
ML21064A153
Person / Time
Site: 07003103
Issue date: 02/25/2021
From: Lorskulsint P
Louisiana Energy Services, URENCO USA
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
LES-21-030-NRC
Download: ML21064A153 (10)


Text

2/25/2021 LES-21-030-NRC ATTN: Document Control Desk Director Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Louisiana Energy Services, LLC NRC Docket No. 70-3103

  • ~?-~

Emchment Facility

Subject:

Semi-Annual Radiological Effluent Release Report for July 1, 2020 through December 31, 2020 Pursuant to 10 CFR 70.59, Louisiana Energy Services, LLC, also dba URENCO USA, herewith submits the subject report. Enclosure 1 specifies the quantities released of licensed principal radionuclides in liquid or gaseous form, to uncontrolled areas Should there be any questions regarding this submittal, please contact Wyatt Padgett, Licensing and Performance Assessment Manager at 575-394-5257.

Respectfully, D1g1tally s,grnid by P Paul L.orskul<mt Dau, 2021 0225 16 01 36--07'00' Paul Lorskulsint Compliance Manager

Enclosure:

1. Semi-Annual Radiological Effluent Release Report for July 1, 2020 through December 31, 2020 Loulalane Energy Services, LLC UUSA I P O Box 1789 I Eunice I New MeXJCO I 88231 I USA T +1 (575) 394 4648 I W www uusa urenco com C 2021 loUISl!lne Energy Service6, LLC 1

LES-21-030-NRC CC:

USNRC Region 11 RidsRgn2MailCenter@nrc.gov Kevin Ramsey, Project Manager - UUSA U.S. Nuclear Regulatory Commission Kevin.Ramsey@nrc.gov Louisiana E.--gy Services, LLC UUSA I P O Box 1789 I Eunice I New MeXJCO I 88231 I USA T +1 (575) 3!M 4846 I W www uuaa urenco com

=

2021 Lou111111na Energy SeMCM, LLC 2

  • u~

Enrichment Facdrty

LES-21-030-NRC USA The~

Enrichment Facllrty ENCLOSURE 1 Semi-Annual Radiological Effluent Release Report for July 1, 2020 through December 31, 2020 Louisiana Energy &trtlcea, UC UUSA J P O Box 1769 I Eurnce I New Mexico I 88231 J USA T +1 (575) 394 4646 J W www UU88 urenco com Cl 2021 Lou1S18118 Energy Services, LLC 1

URENCO USA: Report of Radioactivity In Effluents: Liquid & Air: July 2020 - December 2020 There were no releases to the public during the reporting period that exceeded regulatory requirements, and detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentration dose.

In liquid effluent, the concentrations of isotopic uranium were erther below the Minimum Detectable Concentration (MDC) or less than 10% of values listed m 10 CFR 20, Appendix B, Table 3, "Releases to Sewers" (Table 1-1).

In gaseous effluent, the gross uranium actIvrty was either below the Minimum Detectable Activity (MDA) or less than 10% of values listed in 10 CFR 20, Appendix B, Table 2, "Effluent Concentrations - Class D Air" for U234, U235, and U238 The concentrations of isotopic uranium m gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less than 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20 1101 ( d), as described in NRC Regulatory Guide 4.20 "Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors" Revision 1 dated Apnl 2012.

UST OF TABLES Table No.

1-1 1-2 1-3 1-4 1-5 1-6 Tltle Lift Station 1 Wastewater Effluent - Radionuclides Quarters 3 & 4, 2020 Separations Building Module-1001 (SBM 1001) Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2020 Separations Building Module-1003 (SBM 1003) Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA 1 & 1003-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2020 Separations Building Module-1005 (SBM 1005) Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA 1 & 1005-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2020 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 & 1100-562-1 MA2 - Gross Alpha &

Gross Beta, and Radionuclides Quarters 3 & 4, 2020 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA 1 & 1100-562-2MA2 - Gross Alpha &

Gross Beta, and Rad1onuclides Quarters 3 & 4, 2020

TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides, Quarters 3 & 4, 2020 URENCO USA Lea County, New Mexico Sample Total Resuts Coooting Total Quantity

% of Table 3 of Appendll< B to Tfme Uncettalnty FloW" Released 10 CFR 20 ValtJel..Monthly Period (days)

(JJCi/ml)

(µCUml)

(gal/day)

(Cl)

Average Release to Sewer&

Lift Station 1 - Jul - December 2020 Uranium - 233/234 3.00E-11 Result 2.20E-10 13,000 Below LLD Result Below LLD Uranium - 235/236 11/2/20 0954 07/01/20 -

183 0.00E+00 Result 12/31/20 0.00E+00 13,000 Below LLD Result Below LLD Uranium - 238 1.00E-11 Result 5.00E-11 13,000 Below LLD Result Below LLD Lift Station 1 Duplicate - July - December 2020 Uranium - 233/234 3.00E-11 Result 1.90E-10 13,000 Below LLD Result Below LLD Uranium - 235/236 11102/20 07/01/20 -

183 0.00E+00 Result 0956 12/31/20 0.00E+OO 13,000 Below LLD Result Below LLD Uranium - 238 800E-11 2.00E-11 Result 13,000 Below LLD Result Below LLD Notes:

1.
  • = Table 3.4-4 'Anticipated Normal Plant Water Consumption" from the Environmental Report, Rev. 19, lists "Total Personnel Water Use" as approximately 13,000 gallons per day.
2.

µCi/ml = microCuries per milliliter.

3.

Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs, NM.

4.

Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.09E-9 µCi/ml.

USA The National Enrichment Facility

TABLE 1-2 Separations Building Module-1001 (SBM 1001 ): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2020 URENCO USA Lea County, New Mexico.

1001-562-1 MA1 10015621MA1 070120 08/03/20 7 /1 /20 - 8/3/20 3.52E-17 9.69E-17 6.76E-08 5.65E+05

<MDA

<MDA 10015621MA1 080320 09/01/20 8/3/20 - 9/1/20 5.88E-17 1.62E-16 6.76E-08 4.18E+05

<MDA

<MDA 10015621MA1 090120 10/01/20 9/1/20 - 10/1/20 Gross 0.OOE+OO 1.65E-16 0.OOE+OO 5.33E+05

<MDA

<MDA 10015621MA1100120 11/04/20 10/1/20 - 11/4/20 Alpha 1.B0E-16 2.39E-16 9.91E-08 6.13E+05

<MDA

<MDA 10015621MA1110420 12/01/20 11 /4/20 - 12/1 /20 6.32E-17 1.74E-16 6.76E-08 4.87E+05

<MDA

<MDA 10015621MA1 120120 01/04/21 12/1/20 - 1/4/21 0.00E+00 1.44E-16 0.00E+00 5.84E+05

<MDA

<MDA 10015621MA1 070120 08/03/20 7/1/20 - 8/3/20 2.31E-15 1.93E-15 1.38E-06 5.65E+05 0.00 0.08%

10015621MA1 080320 09/01/20 8/3/20 - 9/1/2Cr 4.86E-15 3.22E-15 1.47E-06 4.18E+05 0.00 0.1 6%

10015621MA1 090120 10/01/20 9/1 /20 - 10/1/20 Gross 6.40E-15 3.27E-15 1.60E-06 5.33E+05 0.00 0.21%

10015621MA1100120 11/04/20 10/1/20 - 11/4/20 Beta 6.90E-15 4.76E-15 1.46E-06 6.13E+05 0.00 0.23%

10015621MA1110420 12/01/20 11/4/20 - 12/1/20 4.14E-15 3.46E-15 1.38E-06 4.87E+05 0.00 0.14%

10015621MA1 120120 01/04/21 12/1/20 - 1/4/21 4.16E-15 2.87E-15 1.46E-06 5.84E+05 0.00 0.1 4%

1001-562-1MA2 10015621MA2 070120 08/03/20 7 /1 /20 - 8/3/20 5.37E-17 1.48E-16 6.76E-08 4.61E+05

<MDA

<MDA 10015621MA2 080320 09/01/20 8/3/20 - 9/1 /20 5.88E-17 1.62E-16 6.76E-08 4.18E+05

<MDA

<MDA 10015621MA2 090120 10/01/20 9/1 /20 - 10/1 /20 Gross 2.62E-17 1.62E-16 6.76E-08 4.39E+05

<MDA

<MDA 10015621MA2 100120 11/4/20 10/1 /20 - 11 /4/20 Alpha

-3.37E-17 1.39E-16 6.76E-08 5.06E+05

<MDA

<MDA 10015621MA2110420 12/01/20 11 /4/20 - 12/1 /20 2.62E-16 1.77E-16 1.40E-07 3.99E+05 1.05E-10 0.01%

10015621MA2 120120 01/04/21 12/1/20 - 1/4/21 5.16E-17 1.42E-16 6.76E-08 4.82E+05

<MDA

<MDA 10015621MA2 070120 08/03/20 7/1/20- 8/3/20 3.33E-15 2.94E-15 1.36E-06 4.61E+05 1.53E-09 0.11%

10015621MA2 080320 09/01/20 8/3/20 - 9/ 1/20 4.86E-1 5 3.22E-15 1.47E-06 4.18E+05 2.03E-09 0.16%

10015621MA2 090120 10/01/20 9/1 /20 - 10/1 /20 Gross 3.64E-1 5 3.22E-15 1.48E-06 4.39E+05 1.60E-09 0.12%

10015621MA2 100120 11/4/20 10/1/20 - 11/4/20 Beta 3.36E-15 2.76E-15 1.74E-06 5.06E+05 1.?0E-09 0.11 %

10015621 MA2 110420 12/01/20 11 /4/20 - 12/1 /20 5.32E-15 3.52E-15 1.47E-06 3.99E+05 2.12E-09 0.18%

10015621MA2 120120 01/04/21 12/1/20 - 1/4/21 4.27E-15 2.82E-15 1.47E-06 4.82E+05 2.06E-09 0.14%

1001-562-1MA1 U-233/234 2.61E-16 1.44E-16 1.45E-16 1.12E-16 0.00 0.009%

U-235/236 3Qtr.

10/1/2020 7 /1 /20-10/4/20 4.60E-17 7.83E-17 7.83E-17 1.38E-16 1.52E+06

<MDC

<MDC U-238 2.35E-16 1.34E-16 1.35E-16 8.88E-17 0.00 0.008%

U-233/234 3.05E-16 1.79E-16 1.B0E-16 1.69E-16 0.00 0.010%

U-235/236 4Qtr.

1/4/2021 10/4/20-1 /4/21 8.50E-17 1.11E-16 1.12E-16 1.70E-16 1.68E+06

<MDC

<MDC U-238 2.02E-16 1.36E-16 1.37E-16 9.54E-17 0.00 0.007%

1001-562-1 MA2 U-233/234 1.60E-16 7.1 2E-17 7.21E-17 3.70E-17 0.00 0.005%

U-235/236 J~r.

10/1/2020 7/1/20-10/4/20 2.70E-17 3.27E-17 3.27E-17 3.99E-17 1.32E+06

<MDC

<MDC U-238 1.58E-16 7.09E-17 7.18E-17 4.05E-17 0.00 0.005%

U-233/234 2.82E-16 1.04E-16 1.05E-16 5.0?E-17 0.00 0.009%

U-235/236 4 Qtr 1/4/2021 10/4/20-1/4/21 1.05E-16 6.98E-17 7.02E-17 5.82E-17 1.39E+06 0.00 0.004%

U-238 1.92E-16 8.67E-17 8.77E-17 6.36E-17 0.00 0.006%

Notes: None USA The National EnrlChmont Facility

TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA 1 &

1003-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2020 URENCO USA Lea County, New Mexico 1003-562-1 MA 1 10035621MA1 070120 09/01/20 7/1/20 - 9/1/20 8.81E-17 7.91E-17 1.17E-07 9.70E+05 8.54E-11 10035621MA1 090120 10/01/20 9/1 /20

  • 10/1 /20 1.82E-16 1.63E-16 1.17E-07 4.71E+05 8.56E-11 10035621MA1 100120 11/04/20 10/1 /20 - 11 /4/20 Gross 5.54E-17 1.52E-16 Alpha 6.76E-08 1.41 E+04

<MDA 10035621 MA 1 110420 12/01/20 11 /4/20 - 12/1 /20 O.OOE+OO 1.79E-16 O.OOE+OO 3.51 E+05

<MDA 10035621MA1 120120 01/04/21 12/1/20 - 1/4/21

-2.98E-17 1.43E-16 1.27E-10 5.49E+05

<MDA 10035621MA1 070120

.09/01/20 7/1/20- 9/1/20

,1.59E-15 1.57E-i5 1.32E-06 9.70E+05 1.54E-09 10035621MA1 090120 10/01/20

, 9/1/20 - 10/1/20 3i40E-15 3.25E-15 1.40E-06 4.71E+05 1.60E*09 10035621MA1 100120 11/04/20 10/1 /20 - 11 /4/20 Gross 3.82E-15 3.03E-15 1.40E-06 Beta 1.41E+04 5.39E-11 10035621 MA 1 110420 12/01/20 11 /4/20 - 12/1120 4.85E-15 3.56E-15 1.50E-06 3.51 E+05 1.70E-09 10035621MA1120120 01/04/21 12/1/20 - 1/4/21 3.58E-15 2.85E-15 1.51E-06 5.49E+05 1.96E-09 1003-562-1 MA2 10035621MA2 070120 09/01/20 7/1/20- 9/1/20 1.64E-17 1.01Es16 6.76E-08 1.01E+06

<MDA 10035621MA2 090120 10/01/20 9/1 /20 - 1 0/1 /20 2.43E-16 1..65E-16 1.40E-07 5.17E+05 1.26E-10 10035621MA2 100120 11/4/20 10/1/20 - 11/4/20 Gross 2.15E-16 1.45E-16 1.40E-07 5.76E+05 1.24E-10 Alpha 10035621 MA2 110420 12/01/20 11 /4/20 - 12/1 /20 1.32E-16 1.82E-16 1.17E-07 4.66E+05

<MDA 10035621 MA2 120120 01/04/21 12/1/20- 1/4/21 4.97E-17 1.37E-16 6.76E-08 6.03E+05

<MDA 10035621MA2 070120 09/01/20 7/1/20 - 9/1/20,

2.28E-15 2.01E-15 1.48E-06*

1.01E+06 2.29E-09 10035621MA2 090120 10/01/20 9/1/20 - 10/1/20 3.92E-15 3.27E-15 1.38E-06 5.17E+05 2.03E-09 10035621MA2 100120 11/4/20 10/1/20 - 11/4/20 Gross 3.46E-15 2.89E-15 1.38E-06 Beta 5.76E+05 1.99E-09 10035621MA2110420 12/01/20 11/4/20 - 12/1/20 3.71E-15 3.63E-15 1.46E-06 4.66E+05 1.73E-09 10035621MA2 120120 01/04/21 12/1/20 - 1/4/21 5.82E-15 2.72E-15 1.65E-06 1003-562-1 MA1 U-2331234 1.70E-16 7.35E-17 7.45E-17 4.91E-17 0.00 U-2351236 3Qtr.

10/1/2020 7.' /1/20-10/4/20 6.13E-17 4.82E-17 4.84E-17 4.40E-17 1.44E+06 0.00 U-238 1.82E-16 7.47E-17 7.58E-17 3.90E-17 0.00 U-233/234 1.44E-16 9.59E-17 9.65E-17 7.96E-17 0.00 U-235/236 4 Qtr 1/4/2021 10/4/20-1/4/21

-6.36E-18 3.77E-17 3.77E-17 8.94E-17 9.14E+05

<MDC U-238 2.09E-16 1.1 4E-16 1.1 5E-16 6.30E-17 0.00 1003-562-1MA2 U-233/234 8.00E-17 5.67E-17 0.00 U-235/236 3Qtr.

  • 10/1/2020 7/1/20-10/4/20 5.18E-17 5.20E-17 6.36E-17 1.52E+06

<MDC U-238

  • 1.29E-16 6.81E-17 6.87E-17 5.14E-17 0.00 U-233/234 2.08E-16 7.82E-17 7.96E-17 3.00E-17 0.00 U-235/236 4 Qtr 1/4/2021 10/4/20-1 /4/21 2.66E-17 3.49E-17 3.49E-17 5.33E-17 1.64E+06

<MDC U-238 1.47E-16 6.58E-17 6.66E-17 3.76E-17 0.00 0.00%

0.01%

<MDA

<MDA

<MDA 0.05%

0.1 1%

0.13%

0.16%

0.12%

<MDA 0.008%

0.007%

<MDA

<MDA 0.076%

0.131%

0.115%

0.124%

0.194%

0.006%

0.002%

0.006%

0.005%

<MDC 0.007%

0;006%

<MDC.

0.004%

0.007%

<MDC 0.005%

Notes: 1003-562-MA2 monitor was in override on 08/03/2020 due to monitor not displaying stack flow or stack volume.

Neither filter in 1003 was collected on 08/03/2020.

USA The National Enrichment Facility

TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 &

1005-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2020 URENCO USA Lea County, New Mexico 1005-562-1MA1 10055621MA1 070120 08/03/20 7/1/20 - 8/3/20 5.41E-17 1.49E-16 6.76E-08 1.04E+06

.:;MDA 10055621 MA 1 080320 09/01/20 8/3/20 - 9/ 1 /20 O.OOE+OO 1.71E-16 O.OOE+OO 8.97E+05

<MDA 10055621MA1 090120 10/01/20 9/1/20 - 10/1/20 Gross 6.04E-17 1.66E-16 6.76E-08 9.51E+05

<MDA 10055621 MA 1 100120 11/04/20 10/1 /20 - 11 /4/20 Alpha 5.41E-17 1.49E-16 6.76E-08 1.08E+06

<MDA 10055621 MA 1 110420 12/01/20 11 /4/20 - 12/1 /20 2.12E-16 1.91E-16 1.17E-07 8.52E+05 1.81E-10 10055621 MA 1 120120 01/04/21 12/1/20 - 1/4/21 O.OOE+OO 1.45E-16 O.OOE+OO 1.06E+06

<MDA 10055621MA1 070120 08/03/20.

7/1 /20 - 8/3/20 "3.91E-15 2.96E-15 1.42E-06 1.04E+06 4.0BE-09 10055621MA1 080320 09/01/20 8/3/20 - 9/ 1 /20 4.49E-15 3.39E-15 1.42E-06 8.97E+05 4.03E-09 10055621 MA 1 090120 10/01/20 9/1/20 - 10/1/20 Gross 4.58E-15 3.30E-15 1.44E-06 9.51E+05 4.36E-09 10055621MA1 100120 11/04/20 10/1 /20 - 11 /4/20 Beta 2.98E-15 2.96E-15 1.32E-06 1.08E+06 3.24E-09 10055621 MA 1 110420 12/01/20 11 /4/20 - 12/1 /20 3.83E-15 3.79E-15 1.32E-06 8.52E+05 3.26E-09 10055621MA1 120120 01/04/21 12/1/20 - 1/4/21 4.37E-15 2.89E-15 1.47E-06 1.06E+06 4.62E-09 1005-562-1 MA2 10055621 MA2 070120 08/03/20 7/1/20 - 8/3/20

-4.06E-17 1.68E-16 6.76E-08 1.06E+06

<MDA 10055621 MA2 080320 09/01/20 8/3/20 - 9/ 1 /20 7.02E-17 1.93E-16 6.76E-08 9.08E+05

<MDA 10055621MA2 090120 10/01/20 9/1 /20 - 10/1 /20 Gross 6.84E-17 1.88E-16 6.76E-08 9.67E+05

<MDA 10055621 MA2 100120 11/04/20 10/1 /20 - 11 /4/20 Alpha O.OOE+OO 1.66E-16 O.OOE+OO 1.11E+06

<MDA 10055621 MA2 110420 12/01/20 11 /4/20 - 12/1 /20 O.OOE+OO 2.05E-16 O.OOE+OO 8.71E+05

<MDA 10055621MA2 120120 01/04/21 12/1/20 - 1/4/21 O.OOE+OO 1.62E-16 O.OOE+OO 1.09E+06

<MDA 10055621MA2 070120 08/03/20 7/1/20 - 8/3/20 4.68E-15 3.33E-15 1.79E-06 1.06E+06 4,96E-09 10055621 MA2 080320 09/01/20 813120 - 9/ 1 /20 5.08E-15 3.84E-15 1.42E-06 9.08E+05 4.61E-09 10055621MA2 090120 10/01/20 9/1 /20 - 10/1 /20 Gross 6.37E-15 3.74E-15 1.53E-06 9.67E+05 6.16E-09 10055621 MA2 100120 11/04/20 10/1/20 - 11/4/20 Beta 4.37E-15 3.30E-15 1.42E-06 1.11 E+06 4.83E-09 10055621 MA2 110420 12/01/20 11 /4/20 - 12/1 /20 9.00E-15 4.0BE-15 1.67E-06 8.71E+05 7.83E-09 10055621 MA2 120120 01/04/21 12/1/20 - 1/4/21 5.47E-15 3.22E-15 1.53E-06 1.09E+06 5.98E-09 MDC

~)

1005-562-1 MA 1 U-233/234 2.90E-16 1.0SE-16 1.07E-16 5.83E-17 0.00 U-235/236 3 Qtr.

10/1/2020 < 7 /1/20-10/4/20 8.17E-17 6.13E-17 6.16E-17 5.73E-17 2.89E+06 0.00 U-238 1.63E-16 7.92E-17 8.01E-17 6.26E-17 0.00 U-233/234 1.55E-16 1.0BE-16 1.09E-16 1.03E-16 0.00 U-235/236 4Qtr.

1/4/2021 10/4/20-1/4/21 O.OOE+OO 5.87E-17 5.87E-17 1.27E-16 2.99E+06

<MDC U-238 2.68E-16 1.38E-16 1.40E-16

8. 18E-17 0.00 1005-562-1 MA2 U-233/234 7 /1/20-10/4/20 L26E-16 6:74E-17 6.80E-17 5.31E-17 0.00 U-235/236 3 Qtr.

10/1/2020

-2.0SE-19 2.21E-17 2.21E-17 6.56E-17 2.93E+06

<MDC U-238 1.71E-16 7.71E-17 7.81E-17 4.74E-17 0.00 U-233/234 4.05E-1 6 1.21E-16 1.24E-16 4.06E-17 0.00 U-235/236 4 Qtr 1/4/2021 10/4/20-1 /4/21 4.01E-17 4.14E-17 4.15E-17 4.37E-17 3.07E+06

<MDC U-238 3.51E-16 1.12E-16 1.15E-16 4.44E-17 0.00 Notes: None USA The National Ennchment Facility

<MDA

.:;MDA

<MDA

<MDA 0.007%

<MDA 0.130%

0.150%

0.153%

0.099%

0.128%

0.146%

<MDA

<MDA

<MDA

<MDA

<MDA

<MDA 0.156%

0.169%

0.212%

0.146%

0.300%

0.182%

0.010%

0.003%

0.005%

0.005%

<MDC 0.009%

0.004%

<MDC 0.006%

0.014%

<MDC 0.012%

TABLE 1-5 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 &

1100-562-1MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2020 URENCO USA Lea County, New Mexico 1100-562-1 MA 1 11005621MA1 070120 11/04/20 7/1/20 - 11/4/20 2.94E-17 3.91E-17 1.40E-07 4.37E+06

<MDA

<MDA 11005621 MA 1 110420 12/1/20 11/4/20 - 12/1/20 Gross 1.36E-16 1.81E-16 Alpha 9.91E-08 9.19E+05

<MDA

<MDA 11005621MA1120120 01/04/21 12/1/20- 1/4/21 1.58E-16 1.42E-16 1.17E-07 1.23E+06 1.95E-10 0.005%

11005621MA1 070120 11/04/20 7/1/20 - 11/4/20 9.79E-16 7.77E-16 1.62E-6 4.37E+06 4.27E-09 0.033%

11005621MA1 110420 12/1/20 11 /4/20 - 12/1 /20 Gross 4.52E-15 Beta 3.59E-15 1.40E-06 9.19E+05 4.16E-09 0.151%

11005621MA1120120 01/04/21 12/1/20 - 1/4/21 5.34E-15 2.82E-15 1.58E-06 1.23E+06 6.57E-09 0.178%

1100-562-1 MA2

' 11005621 MA2 070120 08/03/20 7/1/20 - 8/3/20 1.26E-16 1.68E-16 9.91E-08 1.05E+06

<MDA

<MDA 11005621 MA2 080320 09/01/20 8/3/20 - 9/1/20 8.13E-17 2.24E-16 6.76E-08 9.13E+05

<MDA

<MDA 11005621 MA2 090120 11/04/20 9/1 /20 - 11 /4/20 Gross

-6.44E-3.02E-16 2.12E+06 Alpha 17 9.91E-08

<MDA

<MDA 11005621 MA2 11 0420 12/01/20 11 /4/20 - 12/1 /20 1.36E-16 1.81E-16 9.91E-08 8.81E+05

<MDA

<MDA 11005621 MA2 120120 01/04/21 12/1/20 - 1/4/21 1.59E-16 1.43E-16 1.17E-07 1.18E+06 1.87E-10 0.005%

11006621MA2 070120 08/03/20 7/1/20

  • 8/3/20 6.09E-15 3.33E-15 1.56E-06 1.05E+06 6.39E-09 0.203%

11005621MA2 080320 09/01/20 8/3/20 - 9/1/20 7.84E-15 4.45E-15 1.55E-06 9.13E+05 7.16E-09 0.261%

11005621 MA2 090120 11/04/20 9/1/20 - 11/4/20 Gross 7.25E-15 6.02E-15 1.64E-06 2.12E+06 Beta 1.54E-08 0.242%

11005621 MA2 110420 12/01/20 11 /4/20 - 12/1 /20 4.30E-15 3.59E-15 1.38E-06 8.81 E+05 3.79E-09 0.143%

11005621MA2120120 01/04/21 12/1/20 - 1/4/21 3.76E-15 2.85E-15 1.42E-06 1.18E+06 4.42E-09 0.125%

1100-562-1 MA 1 U-233/234 1.26E-16,

4.60E-17 4.69E-17 2.60E-17 0.00 0.004%

U-235/236 1/4/2021 7/1/20-1/4/21 2.76E-17 2.36E-17 2.37E-17 2.33E-17 2.15E+6 0.00 0.001 %

U-238 1.59E-16 5.15E-17 5.27E-17 2.06E-17 0.00 0.005%

1100-562-1 MA2 U-233/234 1,02E-16 3.17E-17 3,25E-17 1.39E-17 0,003%

u;*2351235 10/1/2020 7/1/20-10/4/20 2,76E-17 1.<19E-17 1.90E-17 1.96E-17 4.09E+6 0.001%

  • U-238 8.69E-17 2.88E-17 2.95E-17 1.10E-17 0.003%

U-233/234 2.21E-16 9.33E-17 9.47E-17 6.11E-17 0.00 0.007%

U-235/236 4 Qtr 1/4/2021 10/4/20-1 /4/21 2.46E-17 3.98E-17 3.98E-17 6.85E-17 2.06E+6

<MDC

<MDC U-238 2.22E-16 9.26E-17 9.40E-17 5.53E-17 0.00 0.007%

Notes: None 1100-562-1 MA 1 Isotopic uranium results not reported for 03 2020. The single filter collected included 03 and 04 results due to the overlap of quarters on this filter. This was due to the redundant monitor, 1100-562-1 M2 being down (due to maintenance issues).

USA The National Enrichment Facility

TABLE 1-6 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-2MA 1 &

1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2020 URENCO USA Lea County, New Mexico 1100-562-2MA 1 11005622MA1 070120 08/03/20 7 /1 /20 - 8/3/20 1.32E-16 1.75E-16 9.91E-08 3.19E+07

<MDA

<MDA 11005622MA1 080320 10/01/20 8/3/20 - 10/1/20 Gross 1.46E-16 9.84E-17 5.87E+07 Alpha 1.40E-07 8.54E-09 0.005%

11005622MA 1 100120 01/04/21 10/1/20 - 1/4/21 8.36E-17 5.65E-17 1.40E-07 9.05E+07 7.57E-09 0.003%

11005622MA1 070120 08/03/20 7/1/20 - 8/3/20 4.84E-15 3.49E-15 1.44E-06 3.19E+07 1.54E-07 0.161%

11005622MA1 080320 10/01/20 8/3/20 - 10/1 /20 Gross 3.45E-15 Beta 1.96E-15 1.55E-06 5.87E+07 2.02E-07 0.115%

11005622MA 1 100120 01/04/21 10/1/20 - 1/4/21 1.56E-1 5 1.12E-15 1.44E-06 9.05E+07 1.41E-07 0.052%

1100-562-2MA2 11005622MA2 070120 08/03/20 7/1/20 - 8/3/20 5.63E-17 1.55E-16 6.76E-08 3.46E+07

<MDA

<MDA 11005622MA2 080320 09/01/20 8/3/20 - 9/1/20 2.87E-16 1.94E-16 1.40E-07 3.11E+07 8.93E-09 0.010%

11005622MA2 090120 10/01/20 9/1/20 - 10/1/20 Gross 7.63E-17 2.10E-16 6.76E-08 3.24E+07

<MDA

<MDA Alpha 11005622MA2 100120 11/04/20 10/1/20 - 11 /4/20 3.70E-16 4.92E-16 9.91E-08 3.54E+07

<MDA

<MDA 11005622MA2 110420 01/04/21 11/4/20 - 1/4/21 0.00E+00 2.13E-15 0.00E+00 5.12E+07

<MDA

<MDA 11005622MA2 070120 08/03/20 7/1/20 - 8/3/20 4.47E-15 3.08E-15 1.46E-06 3.46E+07 1.54E-07 0.1 49%

11005622MA2 080320 09/01/20 8/3/20 - 9/1 /20 5.11E-15 3.87E-15 1.42E-06 3.11 E+07 1.59E-07 0.170%

11005622MA2 090120 10/01/20 9/1 /20 - 10/1 /20 Gross 4.73E-15 Beta 4.18E-15 1.36E-06 3.24E+07 1.53E-07 0.158%

11005622MA2 100120 11/04/20 10/1/20 - 11 /4/20 2.34E-14 9.79E-15 1.71E-06 3.54E+07 8.29E-07 0.781 %

11005622MA2 110420 01/04/21 11/4/20 - 1/4/21 6.40E-14 4.24E-14 1.47E-06 3.28E-06 2.134%

1100-562-2MA 1 U-233/234 2.62E-16 9.06E-17 9.25E-17 4.48E-17 0.00 0.009%

U-235/236 3 Qtr.

10/1/2020 7 /1/20-10/4/20 4.14E-17 4.09E-17 4.10E-17 4.84E-1 7 9.05E+07

<MDC

<MDC U-238 1.60E-16 6.99E-17 7.0BE-17 3.91E-17 0.00 0.005%

U-233/234 3.20E-16 1.06E-16 1.09E-16 5.43E-17 000 0.011%

U-235/236 4 Qtr.

1/4/2021 10/4/20-1 /4/21 7.61E-17 5.71E-17 5.73E-17 5.33E-17 9.05E+07 0.00 0.0025%

U-238 2.58E-16 9.56E-17 9.73E-17 5.83E-17 0.00 0.009%

1100-562-2MA2 U-233/234 2.67E-16 1.04E-16 1.06E-16 7.96E-17 0.00 0.009%

U-235/236 3 Qtr.

10/1/2020 7/1/20-10/4/20 1.64E-17 3.12E-17 3.12E-17 5.77E-17 9.80E+07

<MDC

<MDC U-238 2.28E-16 9.11E-17 9.25E-17 4.24E-17 0.00 0.008%

U-233/234 2.17E-15 7.15E-16 7.32E-16 3.33E-16 0.00 0.072%

U-235/236 4 Qtr.

1/4/2021 10/4/20-1 /4/21 1.71E-16 2.37E-16 2.37E-16 3.60E-16 8.65E+07

<MDC

<MDC U-238 1.41E-15 5.68E-16 5.77E-16 2.91E-16 0.00 0.047%

Notes:

1100-562-2MA 1 080320 filter not pulled in September 2020 due to redundant monitor being out of service for maintenance issues.

1100-562-2MA2 110420 filter not pulled in December 2020 due to redundant monitor being out of service for maintenance issues.

1.

Ci = Curies

2.

µCi/ml = micro-Curies per milliliter.

3.

m* = cubic meters.

4.

MDA = minimum detectable activity.

5.

MDC= minimum detectable concentration.

6.

Quantity released is calculated if the result Equals or Exceeds MDA or MDC.

7.

Radionuclides analyzed using Procedure EPA 908.0 Modified by Eberline Analytical Corp of Oak Ridge, TN.

8.

Gross alpha and beta analyzed by URENCO USA per procedure EN-3-3030-01.