Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Pre-Application Meeting March 10, 2021

Purpose of Topical

  • Staff seeks to understand the purpose of the topical

- Define a framework for implementing a method to establish the fuel qualification specifications? Or

- Establish the actual method for determining fuel qualification specifications? Or

- Both?

Framework for Implementation Staff is seeking to understand the following:

- TS and FSAR requirements for defining the method, which aspects are in the topical, which are in FSAR, change process, etc.

- Qualification report, more information on what is in it, when is it to be submitted?

- Performance/acceptance criteria (i.e. dose rate points), should be specified in the Topical Report and fixed for a single cask and for both transfer and storage, and needs to be able to represent the storage system in terms of 10 CFR 72.236(d)

- Consideration for allowable changes to the design (dimensions, materials) and extent of changes that can be made such that representative source and performance/acceptance criteria continue to be applicable

- Listing of the specific demonstration calculations that will be provided using the representative source(s) and the performance/acceptance criteria in terms of 10 CFR 72.236(d)

Topical as a Method Without more explicit definitions and requirements, this topical may not gain the efficiencies sought:

The topical has guidelines rather than requirements for many aspects of source term and shielding calculations If not explicitly defined, upon implementation, staff will need to determine if the FSAR method conforms to topical guidelines level of staff effort will be similar to current amendment reviews Current information is mostly related to source term determination, the staff is seeking to understand information on shielding evaluations:

Examples are (not limited to): Code/cross sections, tally structure, how various sources are treated/combined (secondary gamma, neutron from sub-critical multiplication, non-fuel hardware), method for calculating overall dose (response function, etc.), fuel representation (explicit or homogenized), material properties, treatment of damaged fuel, etc.

The staff is seeking to understand a well-defined area of applicability Specific assemblies and fuel characteristics and conditions the method is applicable for, examples: fuel assembly types, non-fuel hardware, axial blankets, assemblies with or without steel replacement rods, overall limitations on burnup/cooling time (e.g., high burn-up fuel) based on method limitations etc.