Tennessee Valley Authority, Sequoyah Nuclear Plant, P.O. Box 2000, Soddy Daisy, TN 37384 February 15, 2021 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001

Subject:

Sequoyah Nuclear Plant, Annual Water Withdrawal Report 2020 Attached is the annual water withdrawal report for CY 2020 for Sequoyah Nuclear Plant.

Respectfully, Travis R. Markum Environmental Scientist

State of Tennessee DEPARTMENT OF ENVIRONMENT AND CONSERVATION Division of Water Resources William R Snodgrass Tennessee Tower 312 Rosa L. Parks Avenue, 11 th Floor Nashville, Tennessee 37243 WATER WITHDRAWAL REGISTRATION In accordance with the provisions of Tennessee Code Annotated Section 69-7-301 et seq., the Water Resources Information Act, this registration is required for anyone withdrawing an average of I 0,000 gallons or more of water per day.

See attached instructions.

PART A. FACILITY & CONTACT INFORMATION

1.

Water Withdrawal Registration No.:

628

~~-----

2.

Water User:

TVA - Sequoyah Nuclear Plant Mailing Address: p o Box 2000 OPS 5N-SON Type:

Thermal Plant (Nuclear)

City:

Soddy Daisy State: TN Zip:

37384 County:

Hamilton

3.

Location (if different from mailing address):

Street Address:

Sequoyah Access Road City:

Soddy - Daisy State: _TI!___ Zip:

37379 County:

Hamilton

4.

Number of employees at location:

1069

5.

Indicate the contact individual for water withdrawal information:

Title:

Environmental Scientist (Compliance)

Name:

Travis Markum email:

trmarkum@tva.gov Phone:

423-843-6714 Fax: n/a PART B. WATER USE REPORTING PERIOD

6.

Year:

2020

7.

(Check One):

New Operation

_X_ Renewal

8.

List any water problems you have experienced in-the last reporting period:

N/A

9.

Classifications of Water Use (Enter Percentage of Total use-Total must equal 100%):

a) Domestic water use (drinking, human consumption and general sanitation uses) b) Institutional or other general uses (lawn watering, laundry) c) Irrigation of crops, pastures and nursery stock d) livestock watering (includes feed lots, dairy sanitation and fish farming) e) navigation (lock usage and flow augmentation for navigation) 100 f) thermoelectric power production, including cooling purposes (excludes hydroelectric) g) recreational use, park use, golf course irrigation, water park use h) industrial uses include manufacturing, food processing, washing, and cooling i) hydroelectric power generation (provided none ofit is used consumptively) j) mining (milling or where water is used to wash or process an ore) k) dewatering (mining, quarry rock production, other operations where water is withdrawn)

I) any other use not defined above. Describe:

100 Total (Must equal 100%)

CN-1226 (Rev. 05-15)

RDA2853

WATER WITHDRAWAL INFORMATION Year: ~2=0=2~0 __ Water Withdrawal Registration Number (From Part A, Line 1):

628 Company Name:

TVA-Sequoyah Nuclear Plant Copy this page and submit a completed page for each withdrawal site. See attached instructions.

Part C. Water Withdrawals Source Point ID Number:

N/A Source Point Name:

TN River (ERCW)

Source Type: (G, S, or P): -~-----

County:

Hamilton River Mile: _4~8~4~.8~5~---------

Latitude:

35 32 Longitude: 85 13 Datum (NAD 27 or NAD 83): NAO 27 Map:

NA

~

On File Attached B

Method of Measure (A, B, C, D, or E):

JAN Total Withdrawals:

_ 1,_07_2 ____ MG FEB Total Withdrawals:

--'-1-'-"0=0-=-3 ____ MG MAR Total Withdrawals: _ 1~,_07_7 ____ MG APR Total Withdrawals:

1 018 MG

-~------

MAY Total Withdrawals: -~1 ~15=7~ ___ MG JUNE Total Withdrawals:

1,161 MG JULY Total Withdrawals: __ 1~,2_2_4 ____ MG AUG Total Withdrawals: __ 1-'-'=28=7 ____ MG SEPT Total Withdrawals:

1,220 MG OCT Total Withdrawals: -~1,~1_67 ____ MG NOV Total Withdrawals: ---'-1 =0-=-81-'-___ MG DEC Total Withdrawals: -~1,~0_83 ____ MG

10. Total Annual Withdrawals: _ 13~,_35_0 ____ MG
11. Total# Days Water Withdrawn in Year:

366 Part D. Water Discharge (if applicable)

Discharge Point ID Number: __ 1_1_7 __ _

Discharge Point Name:

TN River (ERCW Backwash)

NPDES Permit No.:

TN0026450 County:

Hamilton River Mile: _ 4~8~4~.8~5~-------

Latitude:

35 32 Longitude:

85 13 Datum: NAD 27 or 83:

NAO 27 Map on file or attached: -~O~o~E-ile _____ _

Method of Measure (A, B, C, D, or E):

B JAN Total Discharge:

FEB Total Discharge:

MAR Total Discharge:

APR Total Discharge:

MAY Total Discharge:

JUNE Total Discharge:

JULY Total Discharge:

AUG Total Discharge:

SEPT Total Discharge:

OCT Total Discharge:

NOV Total Discharge:

DEC Total Discharge:

-~0-~42_5~8 ___ MG 0.4258 MG 0.4258 MG

~ 0~.4=2=5-=-8 ___ MG 0.4258 MG 0.4258 MG

-~0-~42_5~8 ___ MG

--=-0'-'.4=25-=..c8~ __ MG

~~4-2~S~

B ___ MG

_ 0=*~42=5=8~ __ MG

--=-0'-'.4=25""8"---__ MG 0.4258 MG

17. Total Annual Discharges: _5_.1_1 ___ MG
12. Grand Total Water Withdrawals:

~5-=-96=*=2~72~ __ MG 18. Grand Total Discharges:

_6_34~,_81_5 __ MG

13. Grand Total# Days Water Withdrawn in Year:

366

14. Average Daily Water Withdrawals:

37 MGD

15. Maximum Day Water Withdrawal:

--'-43"--_____ MG

16. Maximum Day Water Withdrawal occurred in this month:

September Part E. Signature I certify, under penalty of law, including but not limited to penalties for perjury, that this document and all attachments were prepared by me, or under my direction or supervision; that all of the submitted information is to the best ofmy knowledge and belief true, accurate, and complete; and that I am lawfully present in the United States as a US. citizen or a qualified alien as defined in 8 U.S.C. § 1641(b). As specified in Tennessee Code Annotated Section 39-16-702(aX4), this declaration is made under penalty of perjury. I understand that the penalties for providing false information and making false or fraudulent statements or representations include revocation in a fine, permit or license, civil penalties, and/or criminal prosecution resulting in a fine, imprisonment or both.

Date:

"2-. /1t /z 0 z,

19. P,int Name, Thomas B. Marahall

~

Tit!"

Site Vice Pcesidenl

20. Signature: ~= ~ ~~~~~~~---------

~

CN-1226 (Rev 05-15)

RDA 2853

WATER WITHDRAWAL INFORMATION Year: 2020 Water Withdrawal Registration Number (From Part A, Line 1):

628 Company Name:

TV A - Sequoyah Nuclear Plant Copy this page and submit a completed page for each withdrawal site. See attached instructions.

Part C. Water Withdrawals Source Point ID Number:

N/A Source Point Name:

TN River (CCW)

Source Type: (G, S, or P): -~-----

County:

Hamilton River Mile: _4~8~5~.2~---------

Latitude:

35 33 Longitude: 85 13 Datum (NAO 27 or NAO 83):

NAO 27 Map:

NA

~

On File Method of Measure (A, B, C, D, or E):

Attached B

JAN Total Withdrawals:

50,086 MG FEB Total Withdrawals:

46,855 MG MAR Total Withdrawals: __

50~,_08_6 ____ MG APR Total Withdrawals:

39 853 MG

-~------

MAY Total Withdrawals: -=5=0,=0=8=6 ____ MG JUNE Total Withdrawals:

48,470 MG JULY Total Withdrawals:

50,086 MG AUG Total Withdrawals:

50 086 SEPT Total Withdrawals:

48 470 OCT Total Withdrawals:

50 086 NOV Total Withdrawals:

48,470 DEC Total Withdrawals:

50,086 MG MG MG MG MG

10. Total Annual Withdrawals: _ 5_82_,_72_2 ___ MG
11. Total# Days Water Withdrawn in Year:

366 Part D. Water Discharge (if applicable)

Discharge Point ID Number: __

1_1_6 __ _

Discharge Point Name:

TN River (CCW Backwash)

NPDES Permit No.:

TN0026450 County:

Hamilton River Mile: _ 4~8~5~.2~--------

Latitude:

35 33 Longitude:

85 13 Datum: NAO 27 or 83: --"""N-'-A--'D"---2-'-7 ___ _

Map on file or attached:

-~0~~E=ile _____ _

Method of Measure (A, B, C, D, or E):

B JAN Total Discharge:

FEB Total Discharge:

MAR Total Discharge:

APR Total Discharge:

MAY Total Discharge:

JUNE Total Discharge:

JULY Total Discharge:

AUG Total Discharge:

SEPT Total Discharge:

OCT Total Discharge:

NOV Total Discharge:

DEC Total Discharge:

-=0."-'-18=2=5'---__ MG 0.1825 MG 0.1825 MG

---"0"-.1'-=8=2-=-5 ___ MG 0.1825 MG 0.1825 MG

-=o*c..c18=2=5 ___ MG

---=-0'-'.1-=-82=5"----__ MG 0=*~18=2=5'---__ MG

---=-0'-'.1-=-82=5"------ MG 0.1825 MG

17. Total Annual Discharges: _2_._19 ___ MG
12. Grand Total Water Withdrawals:

_5_9_6~,2_7_2 ___ MG 18. Grand Total Discharges:

_,6..,.3ci4,=8.....,15"---_ MG

13. Grand Total# Days Water Withdrawn in Year:

366

14. Average Daily Water Withdrawals: --~1=5=9-2 ___ MGD
15. Maximum Day Water Withdrawal:

1,616 MG

16. Maximum Day Water Withdrawal occurred in this month:

August Part E. Signature I certify, under penalty of law, including but not limited to penalties for perjury, that this document and all attachments were prepared by me, or under my direction or supervision; that all of the submitted information is to the best of my knowledge and belief true, accurate, and complete; and that I am lawfully present in the United States as a U.S. citizen or a qualified alien as defined in 8 U.S.C. § 1641 (b ). As specified in Tennessee Code Annotated Section 39-16-702(aX4), this declaration is made under penalty of perjury. I understand that the penalties for providing false information and making false or fraudulent statements or representations include revocation in a fine, permit or license, civil penalties, and/or criminal prosecution resulting in a fine, imprisonment or both.

Date:

1,. / fl /z,o z. I

19. Print Name:

Thomas B. Marshall

20. Signature:

~

CN-1226 (Rev. 05-15)~

~

Title:

Site Vice President RDA2853

WATER WITHDRAWAL INFORMATION Year: 2020 Water Withdrawal Registration Number (From Part A, Line I):

628 Company Name: TVA - Sequoyah Nuclear Plant Copy this page and submit a completed page for each withdrawal site. See attached instructions.

Part C. Water Withdrawals Source Point ID Number: N/A Source Point Name: N/A Source Type: (G, S, or P): _N_/_A _____ _

County: _N_/_A __________ _

River Mile: N/A Latitude:

N/A Longitude: _N_IA __________

Datum (NAO 27 or NAO 83): _N_/A ___

Map:

X NA On File Attached Method of Measure (A, B, C, D, or E):

N/A JAN Total Withdrawals:

FEB Total Withdrawals:

MAR Total Withdrawals:

APR Total Withdrawals:

MAY Total Withdrawals:

JUNE Total Withdrawals:

JULY Total Withdrawals:

AUG Total Withdrawals:

SEPT Total Withdrawals:

OCT Total Withdrawals:

NOV Total Withdrawals:

DEC Total Withdrawals:

N/A N/A N/A N/A N/A N/A N/A N/A -------

N/A N/A N/A N/A MG MG MG MG MG MG MG MG MG MG MG MG

10. Total Annual Withdrawals:

NIA MG

11. Total# Days Water Withdrawn in Year:

366 Part D. Water Discharge (if applicable)

Discharge Point ID Number: _1_0_1 ___ _

Discharge Point Name: TN River (Diffuser Pond)

NPDES Permit No.: TN0026450 County:

_H_a_m_i_lt_on ________ _

River Mile: 483.65 Latitude:

35 -1 2 35 Longitude:

_8_5_-__5_-_1_4 _______

Datum: NAO 27 or 83: NAD 27 Map on file or attached:

on File Method of Measure (A, B, C, D, or E):

E JAN Total Discharge:

53,849 FEB Total Discharge:

50,899 MAR Total Discharge:

54,010 APR Total Discharge:

39,527 MAY Total Discharge:

55,024 JUNE Total Discharge:

52,639 JULY Total Discharge:

54,184 AUG Total Discharge:

57,190 SEPT Total Discharge:

54,817 OCT Total Discharge:

55,075 NOV Total Discharge:

53,225 DEC Total Discharge:

54,367

17. Total Annual Discharges:

634,807

12. Grand Total Water Withdrawals:

_5_9_6~,2_7_2 ___ MG 18. Grand Total Discharges:

634,815

13. Grand Total# Days Water Withdrawn in Year:

_3_66 __

14. Average Daily Water Withdrawals:

MGD N/A

15. Maximum Day Water Withdrawal:

N/A


MG

16. Maximum Day Water Withdrawal occurred in this month:

N/A Part E. Signature MG MG MG MG MG MG MG MG MG MG MG MG MG MG I certify, under penalty of law, including but not limited to penalties for perjury, that this document and all attachments were prepared by me, or under my direction or supervision; that all of the submitted information is to the best of my knowledge and belief true, accurate, and complete; and that I am lawfully present in the United States as a U.S. citizen or a qualified alien as defined in 8 U.S.C. § 164 I (b ). As specified in Tennessee Code Annotated Section 39-16-702(aX4 ), this declaration is made under penalty of perjury. I understand that the penalties for providing false information and making false or fraudulent statements or representations include revocation in a fine, permit or license, civil penalties, and/or criminal prosecution resulting in a fine, imprisonment or both.

Date:

2-/ 11./ 2-o-Z. I

19. Print Name:

Thomas B. Marshall

20. Signature:

~~

CN-1226(Rev. 05-1~

=£2

Title:

Site Vice President RDA2853