Text
NRC FORM
592M
U.S.
NUCLEARREGULATORY
COMMISSION
(10-2020)
w
(
Materials
Inspection
Record
1.Licensee
Name:
2.DocketNumber(s):
3.License
Number(s)
Internal
Med.
Associates
ofMt.Clemens030-33050
21-26470-01
4.ReportNumber(s):
5.Date(s)
ofInspection:
2021-001
January
22,2021
6.inspector(s):
7.ProgramCode(s):
8.Priority:9.inspection
Guidance
Used:
RyanCraffey
02201
5
10.Licensee
Contact
Name(s):
11.Licensee
E-mailAddress:
12.Licensee
Telephone
Number(s):
Shelli
Kritzman,
MS
- RSO
mkritzman@mpcphysics.com
734-662-3197
13.Inspection
Type: O Initial14.Locations
Inspected:
15.NextInspection
Date(MM/DD/YYYY):
2 Routine
2 Announced 2
MainOffice
O
Field
Office
gppqg
2 NormalQ Extended
Q Non-RoutineQ UnannouncedQ Temporary
JobSite2
Remote
Q ReducedO Nochange
16.ScopeandObservations:
Thiswasanannounced
routine
inspection,
conducted
remotely,of aprivately-owned
cardiology
practice
authorized
tousebyproduct
material
fordiagnostic
medical
purposes
atits
facility
inMount Clemens,Michigan.
Atthetimeof
theinspection,
onepart-time
nuclear
medicine
technologist
performed up tofive
procedures perday(cardiac
stress
tests
andonrare
occasion
aMUGAstudy)
onMondays
andTuesdays,and
every other
Thursday.
Thelicensee
usedonlyunit
dosesofradiopharmaceuticals
andretained
theservices
ofaconsulting
medical
physicist
tofulfill
the
duties
ofRSO,calibrate
its
survey
instruments,
andaudit
theradiation
safetyprogram
quarterly.
PERFORMANCE
OBSERVATIONS
Using
avideo
teleconference
platform,
thelicensee's
RSOprovided
theinspector
with
awalk-through
oftheclinic
at
133SouthMainStreet
inMountClemens,
including
areview
ofequipment
andlicensed
material
present.
The
facility
appeared
tobeadequately
posted
andall
material
appeared
tobeadequately
secured. The
inspector
observed
theRSOperform
survey
instrument
checks,
dosecalibrator
quality
control
checks,
andsealed
source leak
testing.
Theinspector
alsoobserved
thelicensee's
nuclear
medicine
technologist
perform
demonstrations
of
package
receipt,
dosepreparation,
radioactive
wastehandling,
andareasurveys.
Atthedirection
ofthe
inspector,
thetechnologist
performed
additional
surveys
inrestricted
andunrestricted
areas
ofthefacility.
Noevidence
of
residual
contamination
orexposures
tomembersofthepublic
inexcessofregulatory
limits
werenoted
fromany of
these
surveys.
Theinspector
alsointerviewed
theRSO,technologist,
andthelicensee's
office
manager
todiscuss
thestatus
oftheprogram
andavariety
ofradiation
safety
topics.
Through
these
discussions
andthe
aforementioned
observations,
thelicensee's
staff
demonstrated
proficiency
inALARApractices
andathorough
understanding
oflicensee
procedures,
regulatory
limits
andother
NRCrequirements.
Theinspector
alsoreviewed
aselection
ofrecords,
including
quarterly
consultant
audits,
documentation
ofvarious
surveys
andinstrument
quality
assurance
checks,
sealed
source
inventories
andleak
testresults,
dose
administration
records,
andpersonnel
dosimetry
reports.
Noviolations
ofNRCrequirements
wereidentified
asaresult
ofthis
inspection.
NRCForm592M(10-2020)