ML21012A059

From kanterella
Jump to navigation Jump to search
Information Request for the Cyber-Seruity Full Implementation Inspection, Notification to Perform Inspection 05000315/2021401; 05000316/2021401
ML21012A059
Person / Time
Site: Cook  
(DPR-058, DPR-074)
Issue date: 01/12/2021
From: Hausman G
Engineering Branch 3
To: Gebbie J
Indiana Michigan Power Co
References
IR 2021401
Download: ML21012A059 (8)


See also: IR 05000315/2021401

Text

January 12, 2021

Mr. Joel P. Gebbie

Senior VP and Chief Nuclear Officer

Indiana Michigan Power Company

Nuclear Generation Group

One Cook Place

Bridgman, MI 49106

SUBJECT: DONALD C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2

INFORMATION REQUEST FOR THE CYBER-SECURITY FULL

IMPLEMENTATION INSPECTION, NOTIFICATION TO PERFORM

INSPECTION 05000315/2021401; 05000316/2021401

Dear Mr. Gebbie:

On November 19, 2019, the U.S. Nuclear Regulatory Commission (NRC) provided the

Donald C. Cook Nuclear Power Plant, Units 1 and 2, an Information Request for the

Cyber-Security Full Implementation Inspection and Notification to Perform Inspection

05000315/2020410; 05000316/2020410 (ML19323F427). The onsite portion of this inspection

was to take place during the weeks of March 30, 2020, and April 13, 2020. However, because

of the coronavirus pandemic (COVID-19) and potential related health concerns, the inspection

was delayed by the NRC.

Based on discussions with your staff for an acceptable date to perform this inspection, the NRC

has rescheduled this inspection. The onsite portion of the inspection will take place during the

weeks of June 7 and June 21, 2021. The inspection will be performed in accordance with

Inspection Procedure 71130.10P Cyber-Security, issued May 15, 2017, at your

Donald C. Cook Nuclear Power Plant, Units 1 and 2. The inspection will be performed to

evaluate and verify your ability to meet full implementation requirements of the NRCs

Cyber-Security Rule, Title 10 of the Code of Federal Regulations, Part 73, Section 54,

Protection of Digital Computer and Communication Systems and Networks.

Experience has shown that these inspections are extremely resource intensive, both for the

NRC inspectors and the licensee staff. In order to minimize the inspection impact on the site

and to ensure a productive inspection for both parties, the November 19, 2019, letter

(ML19323F427) enclosed a request for documents needed for the inspection. These

documents were divided into four groups.

The first group specified information necessary to assist the inspection team in choosing

the focus areas (i.e., sample set) to be inspected by the Cyber-Security Inspection

Procedure. This information and the specific items to be reviewed have been previously

provided to the regional office.

The second group of additional requested documents will assist the inspection team in

the evaluation of the critical systems and critical digital assets, defensive architecture,

and the areas of your plants Cyber-Security Program selected for the Cyber-Security

J. Gebbie

2

Inspection. This information and the specific items to be reviewed have been previously

provided to the regional office.

The third group of requested documents consists of those items that the inspection team

will review, or need access to, during the inspection. Please have this information

available by the first day of the onsite inspection, June 7, 2021.

The fourth group of information is necessary to aid the inspection team in tracking issues

identified as a result of the inspection. It is requested that this information be provided to

the lead inspector as the information is generated during the inspection. It is important

that all of these documents are up to date and complete in order to minimize the number

of additional documents requested during the preparation and/or the onsite portions of

the inspection.

The lead inspector for this inspection is George M. Hausman. We understand that our

regulatory contact for this inspection is Kristen M. Harper of your organization. If there are any

questions about the inspection or the material requested, please contact the lead inspector at

630-829-9743 or via e-mail at George.Hausman@nrc.gov.

This letter does not contain new or amended information collection requirements subject to the

Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection

requirements were approved by the Office of Management and Budget, Control

Number 3150-0011. The NRC may not conduct or sponsor, and a person is not required to

respond to, a request for information or an information collection requirement unless the

requesting document displays a currently valid Office of Management and Budget Control

Number.

This letter and its enclosure will be made available for public inspection and copying at

http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in

accordance with Title 10 of the Code of Federal Regulations, Part 2.390, Public Inspections,

Exemptions, Requests for Withholding.

Sincerely,

/RA/

George M. Hausman, Senior Reactor Inspector

Engineering Branch 3

Division of Reactor Safety

Docket Nos. 50-315; 50-316

License Nos. DPR-58; DPR-74

Enclosure:

Document Request for Cyber-Security

Inspection

cc: Distribution via LISTSERV

J. Gebbie

3

Letter to Joel P. Gebbie from George M. Hausman dated January 12, 2021.

SUBJECT: DONALD C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2

INFORMATION REQUEST FOR THE CYBER-SECURITY FULL

IMPLEMENTATION INSPECTION, NOTIFICATION TO PERFORM

INSPECTION 05000315/2021401; 05000316/2021401

DISTRIBUTION:

Jessie Quichocho

Richard Skokowski

RidsNrrDorlLpl3

RidsNrrPMDCCook Resource

RidsNrrDroIrib Resource

John Giessner

Kenneth OBrien

Jamnes Cameron

Allan Barker

DRPIII

DRSIII

ADAMS Accession Number: ML21012A059

Publicly Available

Non-Publicly Available

Sensitive

Non-Sensitive

OFFICE

RIII

NAME

GHausman:mb via

e-mail

DATE

01/12/2021

OFFICIAL RECORD COPY

DOCUMENT REQUEST FOR CYBER-SECURITY INSPECTION

Enclosure

Inspection Report: 05000315/2021401; 05000316/2021401

Inspection Dates:

Weeks of June 7, 2021, and June 21, 2021

Inspection Procedure:

71130.10P, Cyber-Security, Issue Date May 15, 2017

Reference:

Guidance Document for Development of the Request for

Information and Notification Letter for Full-Implementation of

the Cyber-Security Inspection, Issue Date October 26, 2017

(ML17156A215)

NRC Inspectors:

George M. Hausman, Lead

Jasmine A. Gilliam

630-829-9743

630-829-9831

George.Hausman@nrc.gov

Jasmine.Gilliam@nrc.gov

NRC Contractors:

Alan B. Konkal

Alexander R. Prada

561-989-0210

240-449-5791

Alan.Konkal@nrc.gov

Alexander.Prada@nrc.gov

Observer:

TBD

NSIR/DPCP/CSB

I

Information Requested for In-Office Preparation

The initial request for information (i.e., first Request for Information (RFI)) concentrates

on providing the inspection team with the general information necessary to select

appropriate components and Cyber-Security Program elements to develop a

site-specific inspection plan. The first RFI is used to identify the list of critical systems

(CSs) and critical digital assets (CDAs) plus operational and management security

control portions of the Cyber-Security Program to be chosen as the sample set

required to be inspected by the Cyber-Security Inspection Procedure. The first RFIs

requested information is specified below in Table RFI #1. The Table RFI #1

information has been previously provided to the regional office to facilitate the selection

of the specific items that will be reviewed during the onsite inspection weeks.

The inspection team has examined the returned documentation from the first RFI and

identified/selected specific systems and equipment (e.g., CSs/CDAs) to provide a more

focused follow-up request to develop the second RFI. The inspection team has

previously provided the specific systems and equipment list to your staff which

identified the specific systems and equipment that will be utilized to evaluate the

CSs/CDAs, defensive architecture, and the areas of the licensees CSP selected for the

Cyber-Security Inspection. All requests for this information shall follow the

Table RFI #1 and the guidance document referenced above.

DOCUMENT REQUEST FOR CYBER-SECURITY INSPECTION

2

The required Table RFI #1 information has been previously provided.

Table RFI #1

Reference Section 3, Paragraph Number/Title:

Items

1

List All Identified CSs and CDAs

All

2

List CDA Facility and Site EthernetTransmission Control

Protocol/Internet Protocol Based Local Area Networks (LANs) and

Identify Those LANs That Have Non-CDAs on Them

All

3

List CDA Facility and Site Non-Ethernet Transmission Control

Protocol/Internet Protocol Based LANs Including Those Industrial

Networks and Identify LANs That Have Non-CDAs on Them

All

4

Network Topology Diagrams (Be Sure to Include All Network Intrusion

Detection System and Security Information and Event Managements

(SIEM) for Emergency Preparedness (EP) Networks and Security

Level 3 and 4 Networks)

All

8

List All Network Security Boundary Devices for EP Networks and All

Network Security Boundary Devices for Levels 3 and 4

All

9

List CDA Wireless Industrial Networks

All

11 Network Intrusion Detection System Documentation for CSs That Have

CDAs Associated with Them

11.a.1)

11.a.2)

12 SIEM Documentation for CSs That Have CDAs Associated with Them

12.a.1)

12.a.2)

14 List EP and Security Onsite and Offsite Digital Communication Systems

All

25 Cyber-Security Assessment and Cyber-Security Incident Response

Teams

All

28 Copy of Current Cyber Security Plan and Copy of 50.54(p) Analysis to

Support Changes to That Plan

All

29 Copy of Any Licensee-Identified Violations and Associated Corrective

Action Program Documentation to Resolve Issue(s)

All

In addition to the above information, please ensure the following information has been

provided to the inspection team:

(1) Electronic copy of the Updated Finals Safety Analysis Report and technical

specifications.

(2) Name(s) and phone numbers for the regulatory and technical contacts.

(3) Current management and engineering organizational charts.

Based on this information, the inspection team has previously identified and selected

the specific systems and equipment (e.g., CSs/CDAs) from the information requested

by Table RFI #1 and has previously submitted a list of specific systems and equipment

to your staff for the second RFI (i.e., Table RFI #2).

DOCUMENT REQUEST FOR CYBER-SECURITY INSPECTION

3

II

Additional Information Requested to Be Available Prior to Inspection

As stated above, in Section I of this enclosure, the inspection team examined the

returned documentation requested from Table RFI #1 and has previously submitted the

list of specific systems and equipment to your staff for the second RFI (i.e., RFI #2).

The second RFI requested additional information required to evaluate the CSs/CDAs,

defensive architecture, and the areas of the licensees CSP selected for the

Cyber-Security Inspection. The additional information requested for the specific

systems and equipment is identified in Table RFI #2. All requests for this information

shall follow the Table RFI #2 and the guidance document referenced above.

The Table RFI #2 information has previously been submitted on CD to the lead

inspector. If you have any questions regarding this information, please call the

inspection team leader as soon as possible.

Table RFI #2

Reference Section 3, Paragraph Number/Title:

Items

5

Plant Computer System Block Diagram (If Plant Computer System Is

Selected for Inspection)

All

6

Plant Security System Block Diagram (If Security Computer System Is

Selected for Inspection)

All

7

Systems That Are Distributed Block Diagrams (For Systems Selected

for Inspection)

All

10 Host-Based Intrusion Detection System Documentation (For CDAs for

Systems Selected for Inspection)

10.a.1)

10.a.2)

13 List All Maintenance and Test Equipment Used on CDAs for Systems

Selected for Inspection

All

15 Configuration Management

All

16 Supply Chain Management

16.b.

16.c.1)

16.c.5)

16.c.6)

17 Portable Media and Mobile Device Control

All

18 Software Management

All

20 Vendor Access and Monitoring

All

21 Work Control

All

22 Device Access and Key Control

All

23 Password/Authenticator Policy

All

24 User Account/Credential Policy

All

26 Corrective Actions Since Last U.S. Nuclear Regulatory Commission

Inspection

All

27 Cyber Security Assessments for Selected Systems

All

DOCUMENT REQUEST FOR CYBER-SECURITY INSPECTION

4

III

Information Requested to Be Available on First Day of Inspection

For the specific systems and equipment identified in this enclosuresSection II, provide

the following RFI (i.e., Table 1st Week Onsite) on CD by June 7, 2021, the first day of

the inspection. All requests for this information shall follow the Table 1st Week Onsite

and the guidance document referenced above.

Please provide five copies of each CD submitted (i.e., one for each

inspector/contractor). The preferred file format for all lists is a searchable Excel

spreadsheet file. These CDs should be indexed and hyper-linked to facilitate ease of

use. If you have any questions regarding this information, please call the inspection

team leader as soon as possible.

Table 1st Week Onsite

Reference Section 3, Paragraph Number/Title:

Items

10 Host-Based Intrusion Detection System Documentation for CDAs for

Systems Selected for Inspection

10.a.3)

thru

10.a.12)

11 Network Intrusion Detection System Documentation for CSs That Have

CDAs Associated with Them

11.a.3)

thru

11.a.15)

12 SIEM Documentation for CSs That Have CDAs Associated with Them

12.a.3)

thru

12.a.14)

16 Supply Chain Management

16.c.2)

16.c.3)

16.c.4)

19 Cyber-Security Event Notifications

All

29 Update to Licensee Identified Violations and Corrective Action Program

Actions Taken Since the Initial Request Was Made

All

In addition to the above information please provide the following:

(1) Copies of the following documents do not need to be solely available to the

inspection team as long as the inspectors have easy and unrestrained access to

them.

a. Original Final Safety Analysis Report Volumes;

b. Original Safety Evaluation Report and Supplements;

c. Final Safety Analysis Report Question and Answers;

d. Quality Assurance Plan;

e. Latest Individual Plant Examination/Probabilistic Risk Assessment Report; and

f.

Vendor Manuals.

DOCUMENT REQUEST FOR CYBER-SECURITY INSPECTION

5

(2) Assessment and Corrective Actions:

a. The most recent Cyber-Security Quality Assurance audit and/or

self-assessment; and

b. Corrective action documents (e.g., condition reports, including status of

corrective actions) generated as a result of the most recent Cyber-Security

Quality Assurance audit and/or self-assessment.

IV

Information Requested to Be Provided Throughout the Inspection

(1) Copies of any corrective action documents generated as a result of the inspection

teams questions or queries during the inspection.

(2) Copies of the list of questions submitted by the inspection team members and the

status/resolution of the information requested (provided daily during the inspection

to each inspection team member).

If you have any questions regarding the information requested, please contact the inspection

team leader.