CURTISS...

WRIGHT Nuclear Division 2950 Birch Street Brea, CA 92821 T: 714.528.2301 L F* 714 528.0128 -

www.curtisswright.com/NuclearDivision November 18, 2020 (Revised 12~15-2020 *Remov,ed Customers: So/jet & KHNP)

NRC Document Control U.S-. Nuclear Regulatory Commission*

Was~irmton, DC* 20555--0001

Subject:

1 0CFR Part 21 ~otification ~or SF~1154 Hydniulic_ Fluid' Batch 17BLVS29,3

Reference:

CWND Enertech NRC 20-003 Report

  • _ -:(i) Name and address of the individual or individuals informing the Commission Loretta Anaya, Quality Assurance Manager 2950 Birch Street Brea, CA 9,2821 *

-(ii) Identification of the facility, the activity, or the basic component supplied for such facility or such act~vity within the United States which fails to compLy or contains defect.

Basic Component SF-1154 Hydraulic Fluid Batch Number 17BLVS293 provided by Enertech to the foll owing:

CUSTOMER*

SITE P.O.NO.

CW PROJECT Duke Energy Shearon Harris

'03053099 520342 Entergy Palisades 10563794 770275 Pacific Gas & Electric Diablo Canyon 3501188958 770287 Pacific Gas & Electric.

Diablo Canyon 3501189966 770288 Lumin.ant.

Comanche Peak 453278

  • 830681 First Energy Beaver Valley 45520464 830683 Entergy Grand Gulf 10531691 830689 Entergy_

Arkansas Nuclear One 10542924 830715 Entergy Palisades 10546655 830724 First Energy Perry 47806699

  • 83073Q TVA Watts Bar 4769368.

830780 TVA Watts Bar 4514608 830806 Duke Energy Shearon Harris 03083722 960103 Pacific Gas & Electric Diablo Canvon 3501204336 990253 Duke Enel"QV Shearon Harris 03097719 83.0821

-(iii) Identification of the firm constructing the facility or supplying the basic component

. which fqils to comply or contains a defect.

1

CURl1SS--

WRIGHT Nuclear Division 2950 Birch Street Brea, CA 92821 T: 714.528.2301 IF: 714.528.0128 www.curtisswnght.com/Nuclear01vis1on Supplied/Dedicated by:

Curtiss Wright Nuclear Division Brea Operations - Enertech 2950 Birch Street Brea, CA 92821 Manufactured by:

Momentive Batch Number 17BL VS293

-(iv) Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

Duke Energy, based on a 10CFR Part 21 notification from Lake Engineering, notified Enertech of the issue related to silicon fluid, Batch 17BL VS293. The potential defect identified in the Fluid to have opaque semi solid material. The fluid used in various snubbers. In snubbers, the semi-solid material could potentially block the bleed orifice and cause the snubber to lock up.

-(v) The date on which the information of such defect or failure to comply was obtained.

September 21, 2020

-(vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufacture or being manufactured for one or more facilities or activities subject to the regulations in this part.

CW Enertech procured (3) 200 kg (55-gallon drums) on December 18, 2017 Momentive Batch 17BLVS293. This was separated into smaller 5-gallon container and supplied to the following sites:

CUSTOMER*

SITE P.O.NO.

Duke Energy Shearon Harris 03053099 Entergy Palisades 10563794 Pacific Gas & Electric Diablo Canyon' 3501188958 Pacific Gas & Electric Diablo Canyon 3501189966 Luminant Comanche Peak 453278 First Energy Beaver Valley 45520464 Entergy Grand Gulf 10531691 Entergy Arkansas Nuclear One 10542924 Entergy Palisades 10546655 First Energy Perrv 47806699 TVA Watts Bar 4769368 2

CURliSS-WRIGHT Nuclear Division 2950 Birch Street Brea, CA 92821 T: 714 528.2301 IF: 714.528.0128 www.curtisswright com/Nu(?learDivision TVA

  • Watts Bar 4514608 Duke Energy Shearon Harris 03083722 Pacific Gas & Electric Diablo Canyon 3501204336 Duke Energy Shearon Harris 03097719

-(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time. that has been or will be taken to complete the action.

We understand the potential hazard in regards to the snubber-fluid, however Enertech no longer has any fluid remaining for thi$ batch. *we then informed our customers the fluid was reported to NRG and we are not able to test the fluid and cannot determine if the fluid will have any impact on the safety function of the snubber.

  • -(viii) Any advice related to the defect or failure to comply*about the facility, activity, or basic component that has beeh, is being, or will be given to purchasers or*licensees.

NIA..

-(ix) In the case of early site permit, the entities to whom an early site permit was

  • transferred.

N/A CWND Enertech c1,.1stomers noted herein were notified of their procurement requirements.

Regards, 7/2wik~

Loretta Anaya Quality Assurance Manager, 'Enertech' Nuclear Division Curtiss-Wright 2950 Birch Street, Brea, CA 92821 T: 714-528-2301;1856 ID: 714-982-1856 I F: 714-528-0128 IM: 562-371-5395 Janaya@curtisswdghtcom I www.curtisswnqht.com/NuctearDlyision..

3