ML20356A013

From kanterella
Jump to navigation Jump to search
OEDO-20-00413, 2.206 Petition-Beyond Nuclear - GE Mark I Hardened Vents - E-mail to Petitioner - PRB Initial Assessment - December 18, 2020
ML20356A013
Person / Time
Issue date: 12/18/2020
From: Perry Buckberg
NRC/NRR/DORL/LPL4
To: Gunter P
Beyond Nuclear
Buckberg P
Shared Package
ML20294A090 List:
References
2.206, EPID L-2020-CRS-0003, OEDO-20-00413
Download: ML20356A013 (5)


Text

From:

Buckberg, Perry To:

Paul Gunter Cc:

Mark Leyse; kevin@beyondnuclear.org

Subject:

2.206 Petition Initial Assessment - GE Mark I BWR hardened vent system Date:

Friday, December 18, 2020 4:42:00 PM

Paul,

The Petition Review Board (PRB) has completed its initial assessment of the petition you submitted on October 16, 2020. Your petition requested that the U.S. Nuclear Regulatory Commission (NRC) take enforcement action against licensees of all Boiling Water Reactors (BWRs) with Mark I containment systems in the form of a suspension of operating licenses until all hardened containment vent systems (HCVSs) are replaced. The basis of your petition is that the hardened containment vent (HCV) requirements in NRC Order EA 109 did not account for the thermal energy produced by chemical reactions that would occur during a severe accident (SA) and, therefore, would not prevent a BWR Mark I primary containment from failing in an SA. The petition includes various SA phenomena that could cause higher flow than what the HCV is designed to pass.

The PRB performed its initial assessment to determine whether the petition meets the applicable acceptance criteria in NRCs Management Directive MD 8.11, Review Process for 10 CFR 2.206 Petitions, and its associated Handbook (DH) 8.11,Section III.C.1 (Agencywide Documents Access and Management System (ADAMS) Accession number ML18296A043). The PRBs initial assessment is that in issuing NRC Order EA 13-109 and since, the NRC did consider and/or analyze and document the SA conditions included in your petition.

The objective of the HCV is not to be able to be used by itself to prevent containment failure. Instead, the HCV is one of a range of tools that the operators could use to prevent or mitigate an environmental release. This is documented as shown below in NRC Order EA 13-109 in Section II:

On March 12, 2012, the NRC issued Order EA-12-050 requiring the Licensees identified in to this Order to implement requirements for a reliable hardened containment venting system (HCVS) for Mark I and Mark II containments. Order EA-12-050 required licensees of BWR facilities with Mark I and Mark II containments to install a reliable HCVS to support strategies for controlling containment pressure and preventing core damage following an event that causes a loss of heat removal systems (e.g., an extended loss of electrical power).

The requirements in this Order, in addition to providing a reliable HCVS to assist in preventing core damage when heat removal capability is lost (the purpose of EA-12-050), will ensure that venting functions are also available during severe accident conditions. Severe accident conditions include the elevated temperatures, pressures, radiation levels, and combustible gas concentrations, such as hydrogen and carbon monoxide, associated with accidents involving extensive core damage, including accidents involving a breach of the reactor vessel by molten core debris.

Ensuring that the venting functions are available under severe accident conditions will support the strategies in the Mark I and Mark II severe accident management guidelines for the protection or recovery of the containment, which serves as a barrier to the release of radioactive materials.

This Order will ensure that this additional severe accident venting capability is provided while also achieving, with minimal delays, the purpose of EA-12-050 - to provide a reliable HCVS to control containment pressure and prevent core damage following the loss of heat removal functions.

For accidents that are beyond the design basis, the operator would use the SA management guidelines (SAMGs) to prevent or mitigate a release. SAMGs include lists of equipment that the operator could use. The operator would decide what equipment to use based on its availability and its potential effect on an environmental release.

To explore potential enhancements to measures for preventing and mitigating a release, the NRC performed a study documented in NUREG-2206 which was issued in March 2018 (ADAMS ML18065A048). The study applied the NRCs MELCOR code to simulate accident progression and source term for a range of SA scenarios. The MELCOR code includes models for SA phenomena that could contribute to containment pressurization including the following:

Steam oxidation of zirconium and steel producing hydrogen and heat Steam oxidation of boron carbide producing heat, hydrogen, and carbon monoxide Reflooding of an uncovered core producing steam Core debris relocation into residual water in the reactor vessel lower plenum producing steam Core debris relocation onto the containment floor producing steam, hydrogen, and carbon monoxide by corium-concrete interaction

The study considered a range of mitigation strategies including severe accident water addition (SAWA) and severe accident water management (SAWM) and venting with the HCV. The study demonstrated that the HCV was a beneficial part of strategies for preventing and mitigating releases and concluded that additional regulatory requirements were not justified.

The staff is aware of the potential for re-criticality as a result of relocation of control rods from the core and reflooding the core with un-borated water. However, the staff does not believe that this issue affects the conclusions of the NUREG-2206 study, because of 1) the limited time period for simultaneously having relocated control rods and intact fuel assemblies and 2) the limited likelihood having a core-wide occurrence of relocated control rods and intact fuel assemblies. NRC GSI 155 "Generic Concerns Arising from TMI-2 Cleanup" Rev. 3 (ADAMS ML11353A382) considers the potential for recriticality in BWRs during SA conditions on page 3.155-5. Recriticality would require a core reflood occurring specifically after all control rods have melted but prior to the occurrence of significant fuel rod melting. This is a very narrow window in a SA event of which operators are aware.

Due to the extreme unlikelihood of a recriticality event occurring, the event was not explicitly modeled in the analysis documented in SECY-12-0157 that supported the basis for the SA

capabilities of the HCVS. Similarly, because of the very remote chance of a recriticality event, the EA-13-109 Attachment 2, Section 1.2.1 requirement that HCVS be designed for 1% of licensed thermal power does not consider such an event.

For a petition to be accepted under the DH 8.11 acceptance criteria in Section III.C.1(b)(ii),

the initial criterion and one of three circumstances need to apply. Therefore, because your petition meets the DH 8.11 acceptance criteria in Section III.C.1(b)(ii) The issues raised have previously been the subject of a facility-specific or generic NRC staff review. but none of the additional Section III.C.1(b)(ii) circumstances apply, the PRBs initial assessment is to not accept your petition for review.

I offer you the opportunity to clarify or supplement your petition in a public meeting with the PRB. If you decide to take advantage of this opportunity, the meeting with the PRB would be conducted consistent with the format described in MD 8.11 Section III.F. The PRB will consider your statements and information presented at the meeting, along with the original petition, in making its final determination on whether to accept your petition for review.

Please indicate by December 30, 2020, whether you wish to have this public meeting.

If you have any questions regarding this e-mail, please feel free to contact me at perry.buckberg@nrc.gov.

Thanks, Perry Buckberg Senior Project Manager / Agency 2.206 Petition Coordinator U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation office: (301)415-1383 perry.buckberg@nrc.gov Mail StopO-8B1a, Washington, DC, 20555-0001

Petition Information NRC Response III.C.

The Vents the NRC Requires Would Not Prevent a BWR Mark I Primary Containment from Failing in a SA Order EA-13-109 requires installation of reliable HCVs that will not only assist in preventing core damage when heat removal capability is lost, but will also function in SA conditions (i.e., when core damage has occurred). The objective of the HCV is not to be able to be used by itself to prevent containment failure. Instead, the HCV is one of a range of tools that the operators could use to prevent or mitigate an environmental release. Order EA-13-109 venting upgrades are intended to increase confidence in maintaining the containment function following core damage events.

III.C.1.

The NRCs Explanation of the Basis for the Capacity of the Vents Required by Order EA 109 does not address SA chemical reactions as sources of heat addition In NUREG 2206, the NRC considered all the phases of SAs from heat up of the core to fuel degradation and debris relocation to the lower plenum and finally failure of the reactor lower head. NUREG 2206 assumed that the HCVS required by Order EA-13-109 was in place. In considering all phases of a SA, by definition NUREG 2206 explicitly discusses hydrogen generation and molten core concrete interactions that result from core degradation in a SA. Section 3 of NUREG-2206 provides a detailed discussion of the plant model including the boundary conditions (e.g., operator control, severe accident water addition) and run matrix and the results of accident progression (see Figure 3-14 for snapshots of core degradation process until lower head failure). For example, Table 3-4 contains the total hydrogen generation in the core and figure 3-16 shows the post core damage vent operation and containment pressure

response.

III.C.2.

The Thermal Energy Generated during the Flooding of a Melting-Down Reactor The MELCOR SA progression in NUREG-2206 considers all material oxidation processes including boron carbide (B4C) neutron absorber materials by steam and hydrogen generation upon failure of the control blade sheaths. The details of B4C model can be found in MELCOR Computer Code Manuals, Vol. 2: Reference Manual, Version 2.2.9541, SAND 2017-0876 O, Sandia National Laboratories, January 2017 (ADAMS Accession No. ML17040A420). This is discussed in Section 2.5 on page COR-RM-83 of the manual.

III.C.2.a.

Plant Workers Might Flood a BWR Core without Knowing Its Actual Condition NUREG 2206 considered a sensitivity calculation with water addition shortly after core heat up and prior to vessel breach when the water level reaches the bottom of active fuel. Core cooling led only to a delay in the timing of containment venting, but significantly reduced the amount of radionuclide release to the environment. This sensitivity calculation is discussed on pages 3-56 through 3-58.

III.C.3.

The Thermal Energy Generated if Molten Materials in the Reactor Relocate Downward and Vaporize Large Quantities of Water Relocation of debris to the lower plenum is explicitly modeled in the code calculations documented in NUREG 2206. This phenomena leads to transfer of energy from the hot debris to the water present in the lower plenum resulting in boiling off the water and in some cases to a pressure spike inside the RPV. However, the containment is successfully vented at primary containment pressure limit. An example of this phenomena can be found in Figure 3-10.

III.C.4.

The Fission Chain Reaction (Criticality) May Recommence During a BWR SA NRC GSI 155 "Generic Concerns Arising from TMI-2 Cleanup" Rev.

3 includes a potential for recriticality in BWRs during SA conditions on page 3.155-5. Recriticality would require a core reflood occurring specifically after all control rods have melted but prior to the occurrence of significant fuel rod melting. This is a very narrow window timewise that operators are aware of. Due to this extreme unlikelihood of a recriticality event occurring, the event was not explicitly modeled in the analysis documented in SECY-12-0157 that supported the basis for the SA capabilities of the HCVS including the EA-13-109, Attachment 2 Section 1.2.1 requirement that provides the requirement that the HCVS be designed for 1 percent of licensed thermal power. Subsequent analysis documented in NUREG 2206 and SECY 16-0041 modeled several SA scenarios and demonstrates that additional changes to the HCVS to accommodate a higher thermal power meet neither the adequate protection threshold or the cost justified substantial safety benefit requirements for ordering a change to the HCVS design.

III.C.5.

There Is No Guarantee the Vents the NRC Requires Would Prevent the Containment from Failing in a SA SECY 16-0041 Enclosure 1 (ADAMS ML16049A291) specifically looks at pressure and temperatures associated with SA phenomena and provides reasonable assurance that containment failure can be prevented when a SA occurs.

NUREG 2206 concludes that venting alone is not necessarily an adequate means to prevent containment failure as venting does not prevent other modes of containment failure (liner melt-through and over-temperature failure of the upper drywell head, bypass of the suppression pool and direct release of radioactivity to the environment). A combination of venting and water injection is required to prevent such failures.

Note: The requirement for an HCV is to provide an accident management tool for the operators to use in combination with other accident management tools (such as water addition) to prevent or mitigate a release during an accident that is beyond the design basis. Use of an HCV by itself may not be sufficient to prevent containment failure for an accident that is beyond the design basis.