PublicMeetingwithHoltec HISTORMUMAXStorageSystem AmendmentNo.3 December15,2020

Agenda

  • WelcomeandIntroduction
  • TechnicalIssues
  • PublicComments
  • Conclusion 2

=

Background===

  • InUMAXAmendmentNo.3,Holtec proposedtoincludeTNs24PT1DSCas anapprovedcanistertobestoredwithin Holtecs HISTORMUMAXStorage System.
  • StaffsreviewfocusesonHoltec demonstratingsafetyoftheUMAX storagesystem 3

TechnicalIssues 4

Issue #1 Certificate of Compliance Boundary

  • Holtec proposedcertificateofcompliance (CoC)boundariesinitsresponsestoRAI26 andRAI28(ML20002A300)

TheboundaryoftheHISTORMUMAXlicensebegins whenthecanisterisalreadyloadedandstagedinthe NUHOMStransfercaskandtransferbeginstothe HITRACtransfercask.

Fortheunloadingprocess,theboundaryofthe HISTORMUMAXlicenseiswithremovaloftheDSC fromtheHISTORMUMAXtransfercask.

5

Certificate of Compliance Boundary

  • TheproposedCoC boundariesshouldbe clearandspecific.
  • Theunloadingprocessseemstoimplya transferbacktotheTNNUHOMS.
  • ClearCoC boundaryisimportantforthe stafftomakeitsregulatoryfindings.

6

Certificate of Compliance Boundary

  • StaffseekstodefineCoC boundaryby specifyingclearandspecifictransition pointsandunderstandtheimplications forthesedefinedtransitionpoints.

7

Issue #2 Canister Service Time

  • NRCsRAI27askedabouttherestriction inUMAXFSARthat24PT1DSCcanisters inuseforlongerthan20yearsarenot permittedtobestoredinUMAXsystem.

InresponsetoRAI27(ML20002A300),

Holtec explainedthatthecanisterin storagegreaterthan20yearswillbe removedfromserviceorarenewal applicationwillbesubmitted.

8

Canister Service Time

  • Theservicelifeofthecanisterinthe UMAXstoragesystemiscontrolledonly byUMAXCoC.
  • Clarityofthecanistersallowableservice lifeisimportantforthestafftomakeits regulatoryfindings.
  • Itisnotclearhowthe20yearsis counted.

9

Canister Service Time

  • Staffseekstounderstandtheproposed language;canisterinservicegreater than20yearsasalicenseconditionor TS,whicheverisappropriate.

10

PublicComments 11

Pleasecompletetheonline publicfeedbackform 12