ML20330A189

From kanterella
Jump to navigation Jump to search
Request for Information for an NRC Post-Approval Site Inspection for License Renewal; Inspection Report 05000374/2021010
ML20330A189
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 11/25/2020
From: Ann Marie Stone
NRC/RGN-III/DRS/EB1
To: Bryan Hanson
Exelon Generation Co, Exelon Nuclear
References
IR 2021010
Download: ML20330A189 (5)


See also: IR 05000374/2021010

Text

November 25, 2020

Mr. Bryan C. Hanson

Senior VP, Exelon Generation Company, LLC

President and CNO, Exelon Nuclear

4300 Winfield Road

Warrenville, IL 60555

SUBJECT: LASALLE COUNTY STATION, UNIT 2; REQUEST FOR INFORMATION FOR

AN NRC POST-APPROVAL SITE INSPECTION FOR LICENSE RENEWAL;

INSPECTION REPORT 05000374/2021010

Dear Mr. Hanson

On February 22, 2021, the U.S. Nuclear Regulatory Commission (NRC) will begin a

Post-Approval Site Inspection for License Renewal at your LaSalle County Station, Unit 2. This

inspection will be performed in accordance with NRC Inspection Procedure (IP) 71003. This

inspection will focus on outage related activities to verify license conditions added as part of

your renewed license and a sample of license renewal commitments have been implemented.

In order to minimize the inspection impact on the site and to ensure a productive inspection for

both parties, we have enclosed a request for information needed for the inspection. Insofar as

possible, this information should be provided electronically to the inspector. The information

request has been divided into two groups:

  • The first group lists information necessary for our initial inspection scoping and

in-office preparation activities. During the in-office preparation activities, the inspector

will identify as much as possible the information and activities to be reviewed during

the inspection. This information should be provided to the inspector by

February 1, 2021.

  • The second group includes the additional information required for the inspector to

review the selected activities. This information should be available to the inspector

on-site on February 22, 2021. It is also requested that corrective action documents

and/or questions developed during the inspection be provided to the inspector as the

documents are generated.

We understand that our primary contact for this inspection is Mr. J. Greenblott, of your

organization. If there are any questions about the material requested in the enclosure, please

contact the inspector.

B. Hanson -2-

This letter does not contain new or amended information collection requirements subject to the

Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection

requirements were approved by the Office of Management and Budget, Control

Number 3150-0011. The NRC may not conduct or sponsor, and a person is not required to

respond to, a request for information or an information collection requirement unless the

requesting document displays a currently valid Office of Management and Budget Control

Number.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public

Inspections, Exemptions, Requests for Withholding, of the NRC's "Rules of Practice," a copy of

this letter, its enclosure, and your response (if any) will be available electronically for public

inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS)

component of the NRC's Agencywide Documents Access and Management System (ADAMS).

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the

Public Electronic Reading Room).

Sincerely,

/RA/

Ann Marie Stone, Chief

Engineering Branch 1

Division of Reactor Safety

Docket No. 50-374

License No. NPF-18

Enclosure:

Document Request for Post-Approval

Site Inspection for License Renewal

cc: Distribution via LISTSERV

B. Hanson -3-

Letter to Bryan C. Hanson from Ann Marie Stone dated November 25, 2020.

SUBJECT: LASALLE COUNTY STATION, UNIT 2; REQUEST FOR INFORMATION FOR

AN NRC POST-APPROVAL SITE INSPECTION FOR LICENSE RENEWAL;

INSPECTION REPORT 05000374/2021010

DISTRIBUTION:

Jessie Quichocho

Richard Skokowski

RidsNrrDorlLpl3

RidsNrrPMLaSalle Resource

RidsNrrDroIrib Resource

John Giessner

Kenneth OBrien

Jamnes Cameron

Allan Barker

DRPIII

DRSIII

ADAMS Accession Number: ML20330A189

Publicly Available Non-Publicly Available Sensitive Non-Sensitive

OFFICE RIII RIII

NAME MHolmberg:mb via AStone via e-mail

e-mail

DATE 11/18/2020 11/25/2020

OFFICIAL RECORD COPY

DOCUMENT REQUEST FOR POST-APPROVAL SITE INSPECTION FOR LICENSE RENEWAL

Inspection Report: 05000374/2021010

Inspection Dates: February 22, 2021 - March 5, 2021

Inspection Procedure: IP 71003 Post-Approval Site Inspection for License

Renewal

Inspector: Mr. Mel Holmberg

630-457-6669

Mel.Holmberg@nrc.gov

I. Information Requested Prior to the On-Site Inspection Week

The following information is requested by February 1, 2021, or sooner, to facilitate

inspection preparation. If you have any questions regarding this information, please call

the inspector leader as soon as possible. Please provide the information electronically

in pdf files, Excel, or other searchable formats, preferably on some portable electronic

media (e.g., sharefile folders, CD-ROM, DVD, etc.). The portable electronic media

should contain descriptive names and be indexed to facilitate ease of use. Information

in lists should contain enough information to be easily understood by someone who

has knowledge of light water reactor technology.

1. Provide a list of your license renewal commitments with an approximate completion

status of each.

2. Provide a list of your Aging Management Programs (AMPs), copies of the program

basis documents for each, and a listing of the implementing procedures and action

tracking items for each.

3. For AMPs that are one-time inspection programs, provide a list of work order

numbers for inspections that have been completed. This may be incorporated with

the previous item and should include identification of the inspected component.

4. Provide a list of the one-time inspections credited for license renewal that will be

completed during your outage. This list should include at least the system,

component, work order number, and type of inspection.

5. Provide a list of other planned inspections, which will be conducted during the

outage, that are credited for license renewal. Of particular interest are those that

include areas generally inaccessible at power (e.g., tank internal inspections, drywell

liner inspections and containment coating inspections). Include work order numbers

where applicable.

6. Provide an outage schedule, sufficiently detailed as to list the work orders noted in

Items 4 and 5.

7. Provide current management and license renewal organizational charts.

Enclosure

DOCUMENT REQUEST FOR POST-APPROVAL SITE INSPECTION FOR LICENSE RENEWAL

8. Provide electronic copies of Updated Final Safety Analysis Report, Technical

Specifications, Technical Specifications Bases, and Technical Requirements Manual.

9. Provide copies of any internal/external self-assessments, license renewal program

health reports, and associated corrective action documents generated in preparation

for the inspection.

10. Provide a list of corrective action records (with descriptions) associated with license

renewal aging management inspections or programs that have been issued since

approval of the Unit 2 renewed operating license.

11. Provide a copy of AMPs updated (e.g. revised) or new AMPs established since the

issuance of the Unit 2 renewed operating license (if any) and copies of the program

basis documents for each and associated commitment change documents,

10 CFR 50.59 Evaluations or Screenings for each.

II. Information Requested to be Available When the Inspector Arrives On-Site

on February 22, 2021

1. Copies of the work orders and corrective action records requested during the

preparation week. This will include work orders of inspections to be observed

and completed work orders to be reviewed by the inspector.

2. Contact information for the Outage Control Center to facilitate inspector

observation of the selected work orders.

3. Documentation demonstrating completion of license renewal commitments which

are complete as of the inspection date. For example, this may be in the form of a

binder for each commitment which includes the implementing documentation and

references.

III. Information Requested to be Provided Throughout the Inspection

1. Copies of any corrective action documents generated as a result of the

inspectors questions or queries during this inspection.

2. Copies of the list of questions submitted by the inspector and the status/resolution

of the information requested (provide daily during the inspection).

If you have questions regarding the information requested, please contact the inspector.

2