2 protection office at the beginning of June 2016. Since that time, no SNMs have been used or stored in this room.
- 3. Current status of radioactive material in Room 9 Dr. Jovanovic transferred his authorization for using radioactive materials in Room 9 to Dr. Flaska in February 2016 due to Dr. Jovanovics pending departure from the University. Two of Dr. Jovanovics former graduate students worked as radiation worker in this room under Dr. Flaskas authorization until June 2016. By that time, all SNMs in Room 9 were transferred back to the storage location at the RSEC, and the small quantity of waste with potential uranium contamination was removed and disposed of by the radiation protection office. Since none of the SNM sources used in Room 9 was disposed of or transferred to a different licensee, the NRC form 314, Certificate of Disposition of Material is not required for the decommissioning of this room.
As the current authorized PI for Room 9, Dr. Flaska has been only using sealed radioactive sources that are licensed under the Universitys broad scope License PA-100 in this room. Currently one sealed (0.18 mCi) and one sealed (0.05 mCi) are stored and used in this room.
- 4. Decommissioning Room 9 for the use of dispersible radioactive materials A decommissioning survey of Room 9 for the use of dispersible radioactive materials including SNMs was conducted by the radiation protection office in December 2018. A brief summary of the decommissioning report is given below. The full report is attached as the Enclosure 2 to this request.
As mentioned above, Room 9 has been authorized to Dr. Jovanovic (2012 - 2016) and Dr. Flaska (2016 - present) for the use of radioactive materials. Dr. Jovanovic terminated his use of radioactive materials including SNMs in this room by the end of May 2016. As the currently authorized PI, Dr.
Flaska has been only using sealed sources that are licensed under the Universitys broad scope License PA-100 in this room.
Prior to the decommissioning survey, all dispersible radioactive materials including SNMs were removed from Room 9. Small quantities of waste with potential uranium contamination, including paper towels, gloves and HEPA filters were properly removed and disposed of by the radiation protection office. No radioactive waste was generated during the decommissioning survey.
The experimental chamber used for the LIBS was cleaned and surveyed by a hand-held alpha probe after each use of radioactive material. Before the vacuum chamber was released for unrestricted use, it was surveyed by the radiation protection office using both portable survey instruments and smears analyzed by liquid scintillation counting. No contamination was detected by either survey technique. Room 9 was also routinely surveyed by the radiation protection office before the decommissioning survey was conducted. Any contamination identified during a routine survey would be cleaned and resurveyed in accordance with University policy. Based on the contamination survey history of this room, no contamination was ever detected in this room.
Calibrated hand-held survey instruments - one with a Geiger-Muller (GM) probe and one with an alpha-sensitive scintillation probe - were used during the decommissioning survey. More than 40 smear wipes were collected and counted by a calibrated liquid scintillation counter for removable contamination detection. Neither fixed nor removable contamination was detected. In addition, the radiation level in this room was measured and found to be no greater than ambient,
3 background levels. The two sealed sources (
) in this room were relocated as needed during the survey.
As a conclusion, Room 9 has been properly surveyed and decommissioned for the use of dispersible radioactive materials including SNMs. It will be suitable to be released for unrestricted use in accordance 10 CFR Part 20 Subpart E after the sealed sources (
) are removed from this room.
- 5. Timeline for the decommissioning of Room 9 and the Hammond Building Room 9 has been authorized for the use of both byproduct radioactive materials under the State broad scope License PA-100 and SNMs under the NRC License SNM-95. Two sealed sources licensed under the License PA-100 are currently stored and used in this room. Thus, a multiple-step process would be involved in the decommissioning of Room 9 at Hammond Building. A tentative timeline for the decommissioning process is suggested below:
- i. Room 9 was decommissioned for the use of dispersible radioactive materials including SNMs in December 2018 according to internal, Penn State University EHS procedures.
ii. A License amendment request to remove the Hammond Building from License SNM-95 is submitted to the NRC for review in September 2020.
iii. Sealed sources (
) that are currently present in Room 9 are relocated from Room 9 to Dr. Flaskas new lab in a different building (Hallowell) when it is ready for use.
A close-out survey of Room 9 will be conducted after the sealed sources are relocated.
This might take place in next two to three months upon the completion of the renovation of the lab at Hallowell Building.
iv. NRC approval of the license amendment request submitted in item ii is received around the beginning of December 2020.
- v. The radiation protection office submits a building decommissioning report for the Hammond Building to the Pennsylvania Department of Environmental Protection (PA DEP) for review. The scope of the report will include all labs in the building that were previously authorized for radioactive material work. Meanwhile the University will schedule a confirmatory survey with the PA DEP Decommissioning Office to complete the decommissioning process for this building.
vi. The building will be released for unrestricted use by the PA DEP after it is confirmed to meet the release criteria for unrestricted use.
- 6. Conclusion SNMs were stored and used in Room 9 from October 2014 to May 2016. All SNMs stored or used in this room were transported back to the storage location at the RSEC by the end of May 2016. No SNM is currently stored or used in any room of the Hammond Building.
Based on the decommissioning timeline above, Room 9 and the Hammond Building must be removed from the Universitys License SNM-95 before the next step in the building decommissioning process can be initiated. Moreover, the decommissioning survey of Room 9 indicted that no fixed or removable contamination was present in this room, and it will be suitable to be released for unrestricted use when the sealed non-SNM sources are removed. Therefore, the University requests to amend the License SNM-95 to remove the Hammond Building.
4 With the approval for the removal of the Hammond Building from the License SNM-95, the University will update its Decommissioning Funding Plan (DFP) dated December 12, 2019 accordingly to reflect the change of the Place of Use in its next DFP submittal.
References:
- a. License Amendment Request Letter Dated February 4, 2014
- b. Letter for Approval of Amendment 5 Dated September 18, 2014
- c. Submittal of Decommissioning Funding Plan for License SNM-95 Dated December 12, 2019