November 5, 2020 Mr. Jacob Clos Quality Assurance Manager Fisher Controls International, LLC 1702 South 12th Avenue Marshalltown, IA 50158
SUBJECT:
FISHER CONTROLS INTERNATIONAL, LLCS RESPONSE TO THE U.S.
NUCLEAR REGULATORY COMMISSION INSPECTION REPORT NO.
99900105/2019-201 AND NOTICE OF NONCONFORMANCE
Dear Mr. Clos:
Thank you for your October 21, 2020 (Agencywide Documents Access and Management System (ADAMS) No. ML20300A320), letter in response to the revised Notice of Nonconformances (NONs) that were discussed in the U.S. Nuclear Regulatory Commissions (NRC) letter dated September 21, 2020 (ADAMS Accession No. ML20063M612). We have reviewed your letter and found it to be responsive to the revised NONs documented in the September 21, 2020 letter. We have no further questions or comments at this time and may review the implementation of your corrective actions during a future NRC staff inspection to determine whether full compliance has been achieved and maintained. Please contact Mr.
Yamir Diaz-Castillo at 301-415-2228 or via electronic mail at Yamir.Diaz-Castillo@nrc.gov, if you have any questions or need assistance regarding this matter.
Sincerely, Kerri A. Kavanagh, Chief /RA/
Quality Assurance and Vendor Inspection Branch Division of Reactor Oversight Office of Nuclear Reactor Regulation Docket No.: 99900105
ML20310A282 *via email NRR-002 OFFICE NRR/DRO/IQVB NRR/DRO/IQVB NAME YDiaz-Castillo*
KKavanagh*
DATE 11/05/2020 11/05/2020