Summary of Westinghouse Electric Company 2020 Fuel Performance Update Closed Meeting
ML20301A441
Person / Time
Site: Westinghouse
Issue date: 11/19/2020
From: Ekaterina Lenning
Licensing Processes Branch
To: Dennis Morey
Licensing Processes Branch
Lenning E
Shared Package
ML20301A409 List:
References
EPID L-2020-LRO-0046
Download: ML20301A441 (3)


Text

November 19, 2020 MEMORANDUM TO:

Dennis C. Morey, Chief Licensing Processes Branch Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation FROM:

Ekaterina Lenning, Project Manager /RA/

Licensing Processes Branch Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF WESTINGHOUSE ELECTRIC COMPANY 2020 FUEL PERFORMANCE UPDATE CLOSED MEETING (EPID L-2020-LRO-0046)

On September 15, 2020, Westinghouse Electric Company (Westinghouse) held the 2020 Westinghouse Fuel Performance Update Meeting in a form of teleconference. Westinghouse presented proprietary information regarding Westinghouse fuel performance and its future plans.

Westinghouse provided updates on the pressurized water reactor (PWR) fuel performance and methods: - PWR licensing updates neutronics (qualification of the two-dimensional PARAGON2 transport code - topical report under review), thermal-hydraulics (COBRA-TF code update), AXIOM cladding (licensing plans, properties, performance data, future topical report submittal), changes in performance trends; - boiling water reactor (BWR) fuel performance and methods: debris leaker elimination initiative, Low Tin ZIRLOTM update, TRITON11TM fuel development, PRIME fuel; - accident tolerant fuel (ATF) program: EnCore fuel program, ADOPTTM fuel, chromium-coated cladding, licensing, high burnup/high enrichment activities. Additional topics of discussion were additive manufacturing (AM), Westinghouse AM nuclear fuel components, and reverse engineering development efforts. By letter dated September 14, 2020, Westinghouse submitted presentation slides (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20280A359).

The list of attendees is enclosed.

Enclosure:

List of Attendees CONTACT:

Ekaterina Lenning 301-415-3151

Enclosure ATTENDEES FOR THE SEPTEMBER 15, 2020, WESTINGHOUSE ELECTRIC COMPANY 2020 FUEL PERFORMANCE UPDATE CLOSED MEETING Attendees Organization Joe Donoghue Nuclear Regulatory Commission (NRC)

Gregory Suber NRC Robert Lukes NRC Scott Krepel NRC Mathew Panicker NRC Josh Whitman NRC Paul Clifford NRC Josh Whitman NRC Andrew Proffitt NRC Alice Chung NRC Diana Woodyatt NRC Jeremy Dean NRC Josh Kaizer NRC Paul Clifford NRC Andrew Proffitt NRC Ahsan Sallman NRC John Lehning NRC Lucas Kyriazidis NRC Shanlai Lu NRC Kevin Heller NRC Michelle Bales NRC Andrew Bielen NRC Kevin Ramsey NRC Dennis Morey NRC Ekaterina Lenning NRC Korey Hosack Westinghouse Electric Company (Westinghouse)

Jeffrey Bradfute Westinghouse Parvez Khambatta Westinghouse Nathaniel Mackereth Westinghouse Jeff Kobelak Westinghouse Duane Olinski Westinghouse Javier Romero Westinghouse Ann Marie DeLullo Westinghouse David Mitchell Westinghouse Paul Kerstig Westinghouse Andrew Bowman Westinghouse David Huegel Westinghouse Zeses Karoutas Westinghouse Yun Long Westinghouse Jonathan Wright Westinghouse

ML20301A409 (Package)

ADAMS Accession No.: ML20227A011 (Notice)

ADAMS Accession No.: ML20301A441 (Meeting Summary)

  • via e-mail OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA*

NRR/DSS/SFNB/BC*

NRR/DORL/LLPB/BC*

NAME ELenning DHarrison RLukes DMorey DATE 10/27/2020 11/19/2020 11/19/2020 11/19/2020 OFFICE NRR/DORL/LLPB/PM*

NAME ELenning DATE 11/19/2020