ML20290A784

From kanterella
Jump to navigation Jump to search
Electric Power Research Institute, BWRVIP-25, Revision 1-A: BWR Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines
Date released: 10/27/2020 Download: ML20290A784


3002018310NP, BWRVIP-25, Revision 1-A: BWR Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines.
ML20290A786
Person / Time
Site: 99902016
Issue date: 10/07/2020
From: Rozier Carter
Electric Power Research Institute
To:
Office of Nuclear Reactor Regulation
References
2020-085, BWRVIP-25NP, Rev 1-A
Download: ML20290A786 (277)
Electric Power Research Institute, BWRVIP-25, Revision 1-A: BWR Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines
ML20290A785
Person / Time
Site: 99902016
Issue date: 10/07/2020
From: Palm N
Electric Power Research Institute
To: Holonich J J
Document Control Desk, Office of Nuclear Reactor Regulation
References
2020-085, BWRVIP-25, Rev 1-A
Download: ML20290A785 (5)