Summary of September 17, 2020, Meeting with Entergy to Discuss Proposed License Amendment Request for Arkansas Nuclear One, Units 1 and 2 Request to the Extend Allowable Outage Time for the Emergency Cooling Pond
ML20287A401
Person / Time
Site: Arkansas Nuclear  
Issue date: 10/26/2020
From: Thomas Wengert
Plant Licensing Branch IV
To:
Entergy Operations
Wengert T
Shared Package
ML20287A410 List:
References
EPID L 2020 LRM 0082
Download: ML20287A401 (4)


Text

October 26, 2020 LICENSEE:

Entergy Operations, Inc.

FACILITY:

Arkansas Nuclear One, Units 1 and 2

SUBJECT:

SUMMARY

OF SEPTEMBER 17, 2020, TELECONFERENCE MEETING WITH ENTERGY OPERATIONS, INC. TO DISCUSS PROPOSED LICENSE AMENDMENT REQUEST FOR ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 REGARDING REQUEST TO EXTEND ALLOWABLE OUTAGE TIME FOR THE EMERGENCY COOLING POND (EPID L-2020-LRM-0082)

On September 17, 2020, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Entergy Operations, Inc. (the licensee) via teleconference. The purpose of the meeting was to discuss a proposed license amendment request (LAR) to extend the allowable outage time (AOT) for the emergency cooling pond (ECP) for Arkansas Nuclear One (ANO), Units 1 and 2. The meeting notice and agenda dated September 1, 2020, are available in NRCs Agencywide Documents Access and Management System (ADAMS) under Accession No. ML20245E560. A list of attendees is provided in the enclosure.

The licensee presented information (ADAMS Accession No. ML20255A024) regarding its planned one-time LAR to extend the AOT for the ECP during the licensees planned future modification to install carbon fiber reinforced polymer (CFRP) piping for the ANO, Units 1 and 2, ECP supply piping. The licensee stated that the ANO, Units 1 and 2, technical specifications do not currently provide an AOT for the removal of the ECP from service for maintenance. The licensee further stated that it plans to propose a 65-day AOT per unit, based on the schedule milestones identified in the slide presentation. The licensee noted that the CFRP piping installations will occur prior to and adjacent to a spring refueling outage for the respective unit, and only one units ECP supply pipe will be removed from service at a time. The licensee also identified the contingencies that will be put in place for a potential loss of normal service water system supply during the installations.

The licensee stated that it plans to submit an application based on deterministic criteria, with risk insights provided. Following a discussion with the NRC staff on the topic of risk, the licensee stated that it may also consider a risk-informed application following the appropriate methodologies and acceptance criteria. The licensee stated that it expects to submit the ANO, Unit 2 LAR in the November/December 2020 timeframe, and would submit the ANO, Unit 1 LAR 1 year later.

The NRC staff did not make any regulatory decisions or commitments at the meeting. One member of the public participated in the meeting but did not have any questions or comments.

Public Meeting Feedback forms were not received.

Please direct any inquiries to me at 301-415-4037, or via e-mail at Thomas.Wengert@nrc.gov.

/RA/

Thomas J. Wengert, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-313 and 50-368

Enclosure:

List of Attendees cc: Listserv

ML20287A410 (Package)

ML20287A401 (Meeting summary)

ML20255A024 (Presentation)

  • by e-mail OFFICE NRR/DORL/LPL4/PM*

NRR/DORL/LPL4/LA*

NRR/DORL/LPL4/BC*

NRR/DORL/LPL4/PM*

NAME TWengert PBlechman JDixon-Herrity (SLee)

TWengert DATE 10/26/2020 10/26/2020 10/26/2020 10/26/2020

Enclosure LIST OF ATTENDEES SEPTEMBER 17, 2020, TELECONFERENCE MEETING WITH ENTERGY OPERATIONS, INC.

ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 PROPOSED LICENSE AMENDMENT REQUEST TO EXTEND THE ALLOWABLE OUTAGE TIME FOR THE EMERGENCY COOLING POND U.S. Nuclear Regulatory Commission J. Borromeo, Division of Risk Assessment (DRA)

S. Dinsmore, DRA C. Spore, DRA C. Moulton, DRA C. Tilton, Division of Safety Systems (DSS)

S. Peng, DSS C. Li, DSS A. Buford, Division of Engineering and External Hazards (DEX)

J. Huang, DEX C. Basavaraju, DEX Y. Li, DEX M. Breach, DEX S. Min, Division of New and Renewed Licenses (DNRL)

A. Rezai, DNRL T. Wengert, Division of Operating Reactor Licensing Entergy Operations, Inc.

R. Keele - Manager, Regulatory Assurance D. Bice - Regulatory Assurance G. Flynn - Director, Engineering V. Bond - Manager, Project Engineering S. Thessing - Manager, Operations Support D. Sojka - Lead Engineer B. Thweatt - Supervisor, Engineering R. Brumwell - Engineering M. Dossett - Manager, Major Projects M. Hedgecock - Engineering Support T. Freeman - Engineering Support J. Robinson - Senior Project Manager R. Ploof - Zachry Nuclear (contractor)

C. DeDeaux - Zachry Nuclear (contractor)

R. Summitt - Zachry Nuclear (contractor)

Public B. Bevill (State of Arkansas)