BACKGROUND BRANCH TECHNICAL POSITION ETSB 11*5 Postulated Radioactive Releases Due to a Waste Gas System Leak or Failure During nornial operatiQn of a nuclear power plant, radioactive fission and activation gases and gases that are the result of radiolytic decomposition of water are generated in the reactor and are continuously removed from the reactor coolant. After separation, the gases may be*treated for volume reduc-tion of the nonradioactive species before the radioactive gases are stored for radioactive decay prior to release to the environment. The system to accomplish this separation, reduction, and decay process is called the waste gas system.
The waste gas system at BWRs may include steam air ejectors, vacuum pumps, decay pfpes, moisture separators, condensers, cryogenic distillation, tanks, ambient or chilled charcoal adsorbers, filters, process sampling, instrumenta-tion and radiation monitoring, and control features.
The waste gas system at PWRs may include volume control tank, letdown or shim bleed gas separation, gas stripping, cover gas collection, compressors, recolBbiners, surge and storage tanks, ambient or chilled charcoal adsorbers, moisture separators, condensers, filters, process sampling, instrumentation and radfatfon monitor-ing, and control features. In all cases, the waste gas system is a radioactive gaseous waste management system required by 10 CFR Part 50, Section 50.34a, with system operation in accordance with Section 50.36a.
The design accep-tance criteria for waste gas systems has been given in SRP Section 11.3.
The basic criterion for reactor accidents, including waste gas system failures, is that offsfte doses shall not exceed 25 rem to the whole body (10 CFR Part 100). However, that criterion is predicated on the assumption that the prob-ability of occurence is very small. At least since 1972, ft has been recognized that the probability of an accidental release from the waste gas system is relatively high and that lower dose criteria are appropriate.
Generally two kinds of waste gas system failures have been designated as warrenting evaluation. These are (1) gross system failures, such as rupture of a decay tank (Regulatory Guide 1.24, Rev. O, March 1972) or rupture of a line (Regulatory Gufde l.98, For Comment, March 1976) and (2) malfunctfons, such as operator errors, valve misalignments, malfunction of attendent equip-ment and active component failures. Both the probablities and the consequences of a waste gas system leak or failure depend on the kind of accident considered and the characteristics of the system (Regulatory Guide 1.70 Section 15.7.1, Rev. 3, November 1978).
Waste gas systems characteristics differ between plants, particularly between BWRs and PWRs, but for present purposes the most important difference is between those systems designed to withstand the effects of a hydrogen explo-sion and earthquakes (Regulatory Guide 1.143) and those systems not so designed.
Gross failure of the system is considered much less likely ff the system is designed to withstand explosions 9nd earthquakes. Accordingly, higher dose 11.3-ll Rev. O - July 1981
criteria have been considered appropriate for evaluating gross failure of these fortified systems.* Initially, a 5-rem criterion was used, but more recently the value has been 2.5 rem.
For systems not designed to withstand explosions and earthquakes, the crfterion*has been 0.5 rem.
This dfchot~ had*l~d to a problem fn that system malfunctions appear to be the controlling failure mode and resistance to explosions anij earthquakes provide no protection against operator error and system malfunction.
No system-malfunction type failures have been designated as representative.
However, it appears that an event, such as valve mfsalfgnment or overpressure could g1ve a release approxfmatfng that from the rupture of*a tank or pipe.
Therefore, it was considered that for future safety evaluations the waste gas system failures analyzed could be 1i~fted to tank or pipe ruptures but that the dose criterion fn every case should be 0.5 rem at the exclusion boundary.
The purpose of this BTP fs to provide guidelines on postulated radfoactfve releases due to a radioactive waste gas system leak or failure. The goal is to mfnfmize potential radiation exposures to.workers and the pub1ic, and to provide reasonable assurance that the radiological consequences of a single failure of an active component in the waste gas system would not result in exceeding the guidelines of 10 CFR Part 20 for a unfque unplanned release and would, therefore, be substantially below the guidelines of 10 CFR Part 100 for a postulated event.
The criteria in Section B, below, provide adequate and acceptable design solutions for the concerns outlined above. Thfs position paper sets forth minimum branch requirements and 1s not intended to prohibit the implementation of more rigorous design codes, standards, or quality assurance measures than those indicated nor ieevaluate waste gas systems with limiting conditions for operation based on more conservative calculational assumptions.
- 8.
BRANCH TECHNICAL POSITION I.
Waste Gas System Leak or Faflure Analysis a)
Crfteria: The safety analysfs report (Section 15.7.1) should provide an analysis of the radfologfcal consequences of a single failure of an active component in the waste gas system.
The analysis should provide reasonable assurance that in the event of a unique unplanned release of radioactive gas from the waste gas system, the resulting total.body exposure to an individual at the nearest exclusion area bou~dary will not exceed 0.5 rem. This is consistent with the gufde1fnes of 10 CFR Part 20 and is substantially below the guidelines of b) 10 CFR Part 100.
The bases for the analysis should include the assumption that the waste gas system fails to meet its design intent as required by 10 CFR Part 50 1 Section 50.34a(c), and Appendix A, GOC 60.
Source Term: The safety analysis on the radiological conse-quences of a single failure of an active component in the waste gas system should use a system design basis source term for light-water-cooled nuclear power plants.
The NRC staff method of calculation for this analysis is based on a conservative 11.3-12 Rev. 0 - July 1981
c) assumption that the waste gas system maximum design capacity source term (sustained power operation) is 7 times greater than the source tem considered for normal operation, including anticipated operational occurrences, as given in SRP Section 11.1.
This assumption is in good agreement with previous design basis analysis which used:
- 1)
- 2)
For a PWR:
~ of the operating fission product inventory in the core being released to the primary coolant, or For a BWR:
A fission product release rate consistent with the noble gas release to the reactor coolant of 100 pCf/sec/
MWt (after 30 min. decay).
The analysis should assume principle parameters and conditions typical of the equipment designed to remove radioactive gases from the coolant and process and treat these gases during normal operation, including anticipated operational occurrences by the waste gas system. The NRC staff considers that there would be no major alteration in the use or performance of gas separation, reductfon, and decay equipment prfor to and imme-diately following this unique unplanned release affected by the waste gas system maximum design capacity source term.
Release: The safety analysts* on the radfologfcal consequences of a single failure of an active component in the waste gas system involves a release method having the condequence of being a unique-unplanned release. Such releases are less frequent than those considered by anticipated operational occurrences and cannot be included fn a meaningful annual average for routine releases applicable to plant effluents in 10 CFR Part so. Appendix I. At the same time, the radiological illlJ)act due to such a unique unplanned release has the charac-teristics of an accident and fs important to the health and safety of workers and the public. Waste gas systems designed to acceptance crfterfa of SRP Section 11.3 have low probability of passive failure, excluding events required by the guidelines of 10 CFR Part 100. All principal release points are to be monitored and controlled according to the requirements of 10 CFR Part 50, Appendix A, GDC 60 and 64, and SRP Section 11.5 provides the acceptance crfterfa for release pofnt instrumen-tation to assure that setpofnts are established on gaseous effluent lines prior to exceeding the limits of 10 CFR Part 20.
Therefore, the most credible unique unp.lanned. release would be a major leak or a single active failure of a waste gas system com-ponent releasing gas by a pathway not normally used for planned releases and requiring a reasonable time to detect and take remedial action to terminate the release. The NRC staff considers that the release of a compressed.gas storage tank of a batch-type waste gas system or the inadvertent bypass of the main decay portion of a continuous-type waste gas system (such as charcoal delay beds in a BWR augmented off-gas system) would.provide a conservative assump-tion for any unique unplanned release while the input to the waste 11.3-13 Rev. O - July 1981
gas system is at the system design basis source term. Only the radioactive noble gases (Xe, Kr, Ar} are to be considered since the assumed transit time 1s great enough to permit major radioactive decay of oxygen and nitrogen isotopes. Particulates and radio-iodines are assumed to be removed by pretreatment, gas separation, and intermediate radwaste treatment equipment. The release should be assumed to occur within the building structure housing the waste gas system storage tank or main decay position of the system, and be released to the envfrons without continuous effluent radiation monftorfng to automatically isolate and/or terminate the release.
Ground-level release without credit for a building wake factor should be assumed, and a conservative (5%) short-term diffusion estimate for the value (x?Q') determined by a method outlined in the acceptance criteria in SRP Section 2.3.4.
Ho deposftfon is assumed to occur during downwind transport.
II. Staff Method for Ana1ysfs a)
Pressurfzed Storage Tanks:
The safety analysis for the radio-logical consequences of a single failure of an active component fn a waste gas system with compressed gas storage (holdup or decay) tanks or cover gas tanks assumes that the tank being filled has a major leak to the environs.
The radioactive noble gas inventory in the tank, at 1001 capacity, should be deter-mined based on the system design capacity source term using the parameters and principal components considered for pretreatment and collection of waste gas to the waste gas system tanks during normal operation, including anticipated operational occurrences.
To determ1ne the pressurized storage tank noble gas inventory, the staff method of ca1culation alters the PWR-GALE Code (NUREG-0017) and requires manual calculations to determine the radiological impact.
- 2)
- 3)
- 4)
- 5)
Enter a value of zero for the 11Holdup Time, in days*, for Xe.u Enter a value of zero for the "Holdup Time, in days, for Kr."
Check the value entered for "Fill Time, in days." This should be the average volume for all storage or cover gas tanks. If this is a cover gas system, calculate the effective ffll time based on 201 of the liquid tank volumes.
(Charcoal delay systems are not applicable.) The PWR-GALE Code limits the m1nfmum ffll time to 0.01 days.
Rerun the computer program for this analysis only.
Multiply each noble gas printout given under 11Gas Stripping - Continuous" by 7 to account for the design capacity source term correction.
11.3-14 Rev. O - July 1981
b)
- 6)
Divide the values fn step 5 above by the number of tanks filled per year (equal to 365/value in step 3 above).
This gives to tank inventory A1 for each nuclide.
- 7)
Calculate the radiological impact by the following equation:
Dose (mrem) = I K1A1 (i7Q)(l012 pC1/Ci)/3.15xl07 sec/year
- where, A1 = The noble gas nuclide activity determined in step 6 above, in curies/event.
K1 = The total-body dose factor given as DFB1 in Table B*l of Regulatory Guide 1.109; in mrem-113/pCf/yr.
(i7Q'} = The relative concentration at the nearest exclu-sion boundary given in Figure l of Regulatory Guide 1.24 for ground~level releases, in sec/m3.
- 8)
The sum dose shall be less than 500 mrem.
Using the same parameters, the technical specfficatfons will set a curie limit on a tank, based on the maximum of 500 mrem at the nearest exclusion boundary and using the same noble gas mfxture.
Charcoal Delay Units: The safety analysis for the radiological consequences of a single fa11ure of an active component in a waste gas system with charcoal delay units assumes that the charcoal unft fs bypassed wfth a 1-hour release to the environs.
The staff considers that either a line bypass valve malfunction, control error, or bed bypass would require the remedial action by isolation, and that starting an alternate charcoal unit, ff available, or reducing reactor power could take up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
The radioactive noble gas concentration should be determined based on the system design capacity source term using the parameters and principal components considered for pretreatment and collection of waste gas to the waste gas system charcoal delay units during normal operation, including anticipated operational occurrences.
To determine the releases without the charcoal delay unit, the staff method of calculation uses the BWR-GALE Code (NUREG-0016) and requires manual calculations to determine the radiological impact. Alterations to the PWR-GALE Code (NUREG-0017) are also included.
- 1)
- 2)
Enter a value of 0.02 for the "Holdup Time, fn days, for Xe."
(BWR or PWR-GALE Code)
Enter a value of 0.02 for the "Holdup Time, in days, for Kr."
(BWR or PWR-GALE Code}
11.3-15 Rev. O - July 1981
(This time, about 30 minutes, is considered for gases to travel through the components in the waste gas system via the release*
point to the nearest exclusion boundary.)
- 3)
Rerun the computer progra111 for this analysis only.
- 4)
Multiply each noble gas printout given under "Air Ejector" by 7 to account for the design capacity source term correction.
- 5)
Add to each noble gas value detennfned fn step 4, above, the applicable value for the nuclide given in the source term for normal operation. This step will account for noble gases whfch have been delayed fn the charcoal unft being released during the event.
- 6)
Calculate the radiological impact by the following equation:
Dose (mrem) = I K1 q1 {x?Q) (1012 pCf/Cf) {7.25 x 10-12 yr2/event-sec)
- where,
- 7)
Qi= The noble gas nuclide release rate determined in steps 4 and 5, above, fn curies/yr rate for 2 hrs.
K1 = The total-body dose factor given as DFBi in.Table B-1 of Regulatory Guide 1.109, fn mrem-m3/pc1/yr.
{x7Q) = The relative concentration at the nearest exclusion boundary given in Figure 1 of Regulatory Guide 1.24 for ground-level releases, in sec/m3 The.sum dose shall be less than 500 mrem.
Using the same parameters, the technical specifications will set a maximum release rate to the waste gas system of 100 µCf/se~/MWt (after 30 min. decay) or use the value of Qi (in pCf/sec) determined above, whichever fs less, to assore that the BTP criteria of 500 mrem individual exposure for 2 hrs at the nearest exclusion boundary is met.
11.3-16 Rev. 0 - July 1981