f NRC l'ORM 618 U.S. NUCLEAR RE!ULATORY COMMCSION U
ow CERTIFICATE OF COMPLIANCE Nl I'OR RADIOACTIVE MATERIALS l'ACKAGES 5l N
i
- 1. a CERTInCATE NUMBER
- b. REVISION NUMBER
- c. PACKAGE IDENTIMCATION NUMBLR d PAGE NUMBER g
e TOTAENUMBER PAG 13 gll N
9033 14 USA /9033/B(U) 1 3
g N
- 2. PREAMBLE N
- a. This certificate is issued to certify that the packaging and contents described in item 5 triow, meets the apphcable safety standards set forth in Title 10 N
N Code of Federal Regulations. Part 71," Packaging and Transportation of Radioactive Material."
!I i
- h. This certificate does not seheve the consignor from compliance with any requirernent of the regulations of the U.S. Department of Transportation or other N
applicable regulatory agencies,includsng the government of any country through or into which the package will be transported.
I ljl
- 3. THis CERTinCATE IS ISSUED ON TRE BASIS OF A EAIITY ANALYSIS REPORT OF Tl!E PACK AGE DESIGN OR APPLICATION
~
I a.15 SUED TO (Name and Address) b.11 TEE AND IDENTIRCATION OF REPORT OR APPLICATION.
k' B
W.
(l E
g AEA Technology /OSA, Inc.
Amersham Corporation application dated g
3 40 North Avenue September 24,1993, as supplemented.
g e
Burlington, MA 01803 c DOCKET NUMBER 71 9033 g
g
- 4. CONDmONS g
i This certificate is conditional upon fulfilhng the requirements of 10 CFR Part 71, as applicable. and the conditions specified below.
g 9
5.
(!
R d'
!{j (a)
Packaging N
f W
!j (1)
Model No.: 660,660E,660A,660AE,660B or 660BE I
l Q
a j
(2)
Description g
g E
l
- p A steel encased uranium shielded Gamma Ray Projector. Primary components y
- 3 consist of an outer steel shell, polyurethane potting material, uranium shield, "S" g
3 tube, and end plugs. The contents are securely positioned in the "S" tube by a g
3 source cable locking device and shipping plug. Tamper proof seals are provided g
3 on the packaging. The maximum total weight of the package is approximately 53 g
i pounds.
4 j
3 5
l 3
(3)
Drawings E
N 8
The packaging is constructed in accordance with the following Technical W
8 Operations, Inc. Drawings:
E i
3 E
l (i)
Model No. 660B - Drawing No. 66025, Sheets 1,2 and 3, Rev. F; i
a j
(ii)
Model No. 660 - Drawing No. 66025, Sheets 1, 2, 3, and 4, Rev. B; or g
3 Drawing No. 66030, Sheets 1, 2, 3 and 4, Rev. -;
g, 3
(I 3
(iii)
Model No. 660A - Drawing No. 66030, Sheets 1,2 and 3, Rev. A; or gl 3
Drawing No. 66030, Sheets 1,2, and 3, Rev. D.
gl 3
W j
!)
Model Nos, with an E suffix have an electrical circuit.
(
)
Y l
.3 El l
(b)
Contents j
- J
(!
1 j
i (1)
Type and form of material gi l
g h')
Iridium 192 sources which meet the requirements of special form radioactive material, N
l gll 9l 9806240305 980619 i
C PDR E
i Purn a m m m m m mm m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m l
1 w ____ - __________ - __
gwwwwawwwwwwwwwwwwwwwwwwwwwwwwwwmwwwwwwwwwwwwwwiu gf (NRC FORM 618A CONDmoNs (wn,mwds U.S. NUCLEAR CE*uLAToRY COMMISSloN f
3-96)
D Nj P:ge 2 - Certificate No. 9033 - Revision No.14 - Docket No. 71-9033 B
B p
5.
(b)
Contents (continued)
R p
(2)
Maximum quantity of material per package B
(i) 140 Curies for the Model No. 660B or 660BE package.
B B
(ii) 120 Curies for the Model No. 660,660E,660A or 660AE package.
B U
6.
The source shall be secured in the shielded position of the packaging by the source assembly.
The source assembly must be fabricated of materials capable of resisting a 1475 *F fire environment for one half hour and maintaining their posit oning function. The source assembly i
g must engage the locking device. The source assembly i..ust be of sufficient length and g
diameter to provide positive positioning of the source within the depleted uranium shield h
g assembly.
9 g
7.
The name plate must be fabricated of materials capable of resisting the fire test of 10 CFR Part p
71 and maintaining its legibility.
Bj9 8.
In addition to the requirements of Subpart G of 10 CFR Part 71:
B B
(a)
The package must meet the Acceptance Test and Maintenance Pregram of Chapter 8.0 5
of the application, as supplemented; and (b)
The package shall be prepared for shipment in accordance with the Operating Procedures in Chapter 7.0 of the application, Os supplemented.
g B
9.
For transportation in private carriage, the package must be either:
g D
l g
(a) properly secured within a box attached to the vehicle for the purpose of transporting or y
storing radiography devices. The package must be properly blocked, braced, and l
p supported to prevent shifting within the box during transport, or l
9 5
(b) properly secured within a steel box of welded construction or a steel drum. The i
B package must be properly blocked, braced, and supported to prevent shifting within the B
steel box or steel drum during transport. The steel box or drum must be blocked, B
braced, and secured against movement within the vehicle.
N l
h 10.
For transportation by common carrier, the package must be properly secured within a steel box l
of welded construction or a steel drum. The package must be properly blocked, braced, and g
supported to prevent shifting within the steel box or steel drum during transport. The steel g
box or steel drum must be blocked, braced and secured against movement within the vehicle.
g i
B p
11.
Packagings fabricated after November 17,1997, are not authorized for use.
l
'Ie B'
D l
b l
B-i amamamammaammmaammamasmammamamammammaammamamm
'NR FORM 618A CONumoNs (conia.eds U.S. NUCLEAR RE!uLATORY COMMISSION I
Page 3 - Certificate No. 9033 - Revision No.14 - Docket No. 71-9033 b
D d
D s
b i
B 12.
The package authorized by this certificate is hereby approved for use under general license g
B provisions of 10 CFR 571.12.
g B
N D,
13.
Expiration date: June 30,1999. This certificate is not renewable.
lE D
E D
RFFFRFNCFS l
B E
l Amersham Corporation application dated September 24,1993.
l Supplements dated: March 31,1994; June 28,1995; November 17,18 and 21,1997 and June 17, p
1998.
g b
d b
Nordion International Inc. supplement dated August 19,1996.
g b
q B
d b
FOR THE U.S. NUCLEAR REGULATORY COMMISSION q
B W
D E
l D
B Cass R. Chappell, Chief N
N Package Certification Section N
Spent Fuel Project Office g
Office of Nuclear Material Safety i
g g
and Safeguards -
g Date.
T D
D E
B E
b g
l D
E D
E D
E D
E I
B E
l D
n l
l D
e bl, b
E!
b W
D E,;
D Wl D
Ei i
b; E
bl t
D.
E!
El bl -u............,..........................
8 E
j
$ [Et 3C 1
UNITED STATES 0
=
- [
j NUCLEAR REGULATORY COMMISSION wAswiwarow, o.c. somewoos s
APPROVAL RECORD Model No. 660 Series Packages Certificate of Compliance No. 9033 Revision No.14 l
By application dated June 17,1998, AEA Technology /OSA, Inc. requested an amendment to Certificate of Compliance No. 9033, for the Model No. 660 series packages. AEA Technology /OSA, Inc. requested that the expiration date of the certificate be changed to June 30,1999, in order to allow a period for transition to the Model No. OPL-660 and OP-660 packages (Certificate of Compliance No. 9283). The Model No. OPL-660 and OP-660 packages are intended as replacement packages for the Model No. 660 Series packages. The applicant also requested that the name of the certificate holder be changed from Amersham Corporation to AEA Technology /QSA, Inc.
The Certificate of Compliance for the Model No. 660 Series packages has been revised to l
change the expiration date to June 30,1999, and to specify that the certificate is not l
renewable. This will allow sufficient time for user registration and orderly transition to the l-replacement package. The name of the' certificate holder has also been changed to AEA Technology /OSA, Inc.
The NRC staff agrees with the applicant's conclusion that these changes do not affect the j
ability of the package to meet the requirements of 10 CFR Part 71.
0 44 Cass R. Chappell, Chief Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards 7!98 Date i